• Title/Summary/Keyword: adhesive material

Search Result 750, Processing Time 0.026 seconds

A Study of material analysis and its experimentation of metamorphosis and its utilities in Copper Alloy plates for contemporary metal craft (현대금속공예용 동합금판의 재료분석과 형질변환 실험 및 응용에 관한 연구)

  • Lim, Ock-Soo
    • Archives of design research
    • /
    • v.17 no.4
    • /
    • pp.241-250
    • /
    • 2004
  • In this research, the copper alloy plates C2200, C5210, C7701, C8113 were selected to make datum and to identify further usage of metal craft experimentation. For its experimentation, the general welding and TIG welding methods were researched; for 2nd experimentation, the Reticulation and Electroforming skill's differences in color and temperature were researched. With these methods 3 different kinds of works are introduced for sample studies. For this research, Dr. Lee, Dong-Woo who works in Poongsan Metal Co, supported 4 kinds of copper alloy metals. Which are Commercial bronze (Cu-Zn), Deoxidiged Copper(Cu-Sn-P), Nickel Silver (Cu-Ni-Zn), and White Bronze (Cu-Ni); they were applied partly and wholly by the method of Laminatin, Reticulation, Fusing, and Electroforming skills. In case of C2200, the brass, the A. C. TIG welding method is better under 2mm slight plate; the D.C. TIG welding is better upper 2mm plate; and 250~300$^{\circ}C$ is recommended for remain heat treatment. In case of C5210, not having Hydrogen in high temperature return period, doesn't need Oxygen in high temperature and hardening in comparative high temperature neither, it is good for welding. It contains Sn 2-9% ad P 0.03-0.4% generally; and in accordance with the growth rate of Sn contain amount, the harden temperature boundary become broad. In case of cold moment after welding, they are recommended that higher speed TIG welding, smaller melting site and less than 200$^{\circ}C$ for pre-heating temperature. In case of C7701, the 10-20% Ni, 15-30% Zn are widely used.. If it is upper 30% Zn, it become (${\alpha}+{\beta}$) system and adhesive power rate become lower, and the productivity become lower in low temperature but the productivity become higher in high temperature. Nickel Silver's resistance of electricity is well; and the heatproof and incorrodibility is good, too. Lastly, in case of C8113, good at persistence in salty and grind; high in strength of high temperature. In case of white brass, contain 10-30% Nickel and hardened in high temperature and become single phrase. For these reason, the crystallization particles easily become large, if the resistance become higher small amount of Pb, P, S separation rate become higher.

  • PDF

Suitable Conditions of Producing the LVL from Pitch Pine and its Paint Film Durability (리기다소나무 단판적층재(單板積層材)의 제조조건(製造條件)에 따른 물리적성질(物理的性質) 및 도장성능(塗裝性能))

  • Park, Sang-Bum;Kong, Young-To;Jo, Jae-Myeong
    • Journal of the Korean Wood Science and Technology
    • /
    • v.17 no.1
    • /
    • pp.3-11
    • /
    • 1989
  • This study was carried out to investigate the physical and mechanical properties. durability of adhesive bond and paint film for the basic data which were required to determine the suitability as a raw material for furniture the laminated veneer lumber (LVL) with pitch pine (Pinus rigida Mill). The results obtained were as follows; 1) The proper pressing time for making the LVL was over 45 second per milimeter of LVL thickness. 2) The bending strength of the LVL was lower than that of the solid wood but the compressive strength of the LVL was similar to that of the solid wood. The strength increased with the decrease of veneer thickness. 3) The impact bending absorbed energy of the LVL was 0 to 0.3 kg.m/$cm^2$ in the direction of parallel to the grain. The energy of the LVL was lower than that of the solid wood (0.68 kg.m/$cm^2$). 4) In warm water soaking and cold-dry tests, delamination of adhered layers surface crack, swelling, and color change were not found when the hot pressing time was over 45 second per milimeter of LVL thickness. As a result of soak under vacuum test shrinkage in the direction of parallel to the grain was about -1.0 percent and. was about 3.0 percent in the direction of the perpendicular to the grain. 6) The film cacks on the LVL's surface after the wet and cold-dry test were not found at all. 7) In the use of the LVL for interior decoration it was considered that the surface of the LVL be overlaid crossly with fancy veneers of birch and paulownia, etc. This cross overlayirg methods have resulted in few cracks on the fancy veneer.

  • PDF

Morphology of Larvae, Egg Development and Spawning Behavior of the Blenniid Fish, Pictiblennius yatabei (Jordan et Snyder) (청베도라치, Pictiblennius yatabei의 산란습성(産卵習性), 난발생과정(卵發生過程)및 부화자어(孵化仔魚)의 형태(形態))

  • Kim, Yong-Uk;Myoung, Jung-Goo;Han, Kyeong-Ho;Kang, Chung-Bae
    • Korean Journal of Ichthyology
    • /
    • v.4 no.2
    • /
    • pp.44-54
    • /
    • 1992
  • The blenniid fish, Pictiblennius yatabei(Jordan et Snyder) is ditributed in the central and southern Japan and southern Korea. The fish grows to a maximum size of 9cm in total length, and it seems to be matured in two years. Sex dimorphisms of the fish appear in the crest and the anal fin. Five egg masses of the fish were collected in Tongyoung Bay near Kyeong Nam on June 16 and 20, 1991. The eggs were laid on inner surface of empty shells of the oyster, Crassotrea gigas and blue mussel, Mytilus edulis. Each egg mass was guarded by the male parent. Numbers of eggs in each of masses were as about 450~1000.The eggs were spherical but somewhat oval in shape and ranged from 0.72 to 0.80mm in longer axis and from 0.55 to 0.65mm in shorter axis. Each egg was provided with an adhesive pedestal. Hatching took place in 105 hours after formation of embyo at the water temperature varying from 20.0 to $21.4^{\circ}C$. Melanophores appearing on the yolk remarkably changed in form during the embryonic development.The newly hatched larvae, having 32~34 somites, were from 2.71 to 3.35mm in total length. The larvae absorbed the yolk material and oil globule completely in 7 days after hatching and became postlarvae. Nine days after hatching, the larvae averaged 5.35mm in TL and the caudal notochord flex at $45^{\circ}$ Total lengths of the larvae reached 6.00 and 6.58mm in 11 and 13 days after the hatching, respectively.

  • PDF

The influence of occlusal loads on stress distribution of cervical composite resin restorations: A three-dimensional finite element study (교합력이 치경부 복합레진 수복물의 응력분포에 미치는 영향에 관한 3차원 유한요소법적 연구)

  • Park, Chan-Seok;Hur, Bock;Kim, Hyeon-Cheol;Kim, Kwang-Hoon;Son, Kwon;Park, Jeong-Kil
    • Proceedings of the KACD Conference
    • /
    • 2008.05a
    • /
    • pp.246-257
    • /
    • 2008
  • The purpose of this study was to investigate the influence of various occlusal loading sites and directions on the stress distribution of the cervical composite resin restorations of maxillary second premolar, using 3 dimensional (3D) finite element (FE) analysis. Extracted maxillary second premolar was scanned serially with Micro-CT (SkyScan1072; SkyScan, Aartselaar, Belgium). The 3D images were processed by 3D-DOCTOR (Able Software Co., Lexington, MA, USA). HyperMesh (Altair Engineering. Inc., Troy, USA) and ANSYS (Swanson Analysis Systems. Inc., Houston, USA) was used to mesh and analyze 3D FE model. Notch shaped cavity was filled with hybrid (Z100, 3M Dental Products, St. Paul, MN, USA) or flowable resin (Tetric Flow, Viva dent Ets., FL-9494-Schaan, Liechtenstein) and each restoration was simulated with adhesive layer thickness ($40{\mu}m$). A static load of 200 N was applied on the three points of the buccal incline of the palatal cusp and oriented in $20^{\circ}$ increments, from vertical (long axis of the tooth) to oblique $40^{\circ}$ direction towards the buccal. The maximum principal stresses in the occlusal and cervical cavosurface margin and vertical section of buccal surfaces of notch-shaped class V cavity were analyzed using ANSYS. As the angle of loading direction increased, tensile stress increased. Loading site had little effect on it. Under same loading condition. Tetric Flow showed relatively lower stress than Z100 overall, except both point angles. Loading direction and the elastic modulus of restorative material seem to be important factor on the cervical restoration.

  • PDF

MICROLEAKAGE AND SHEAR BOND STRENGTH OF FLOWABLE COMPOSITE RESIN (Flowable Composite Resin의 미세변연누출 및 전단결합강도)

  • 박성준;오명환;김오영;이광원;엄정문;권혁춘;손호현
    • Restorative Dentistry and Endodontics
    • /
    • v.26 no.4
    • /
    • pp.332-340
    • /
    • 2001
  • Flowable composite resin has lower filler content, increased flow, and lower modules of elasticity. It is suggested that flowable composite resin can be bonded to the tooth structure intimately and absorb or dissipate the stress. Therefore, it may be advantageous to use flowable composite resin for the base material of class II restoration and for the class V restoraton. The purpose of this study was to evaluate the microleakage and shear bond strength of four flowable composite resins (Aeliteflo, Flow-It, Revolution, Ultraseal XT Plus) compared to Z100 using Scotchbond Multi Purpose dentin bonding system. To evaluate the microleakage, notch-shaped class V cavities were prepared on buccal and lingual surfaces of 80 extracted human premolars and molars on cementum margin. The teeth were randomly divided into non-thermocycling group (group 1) and thermocycling group (group 2) of 40 teeth each. The experimental teeth of each group were randomly divided onto five subgroups of eight samples (sixteen surfaces). The Scotchbond Multi-Purpose and composite resin were applied for each group following the manufacturer's instructions. the teeth of group 2 were thermocycled five hundred times between 5$^{\circ}C$ and 55$^{\circ}C$. The teeth of group 2 were placed in 2% methylene blue dye for 24 hours, then rinsed with tab water. The specimens were embedded in clear resin, and sectioned longitudinally with a diamond saw. The dye penetration on each of the specimen were observed with a stereomicioscope at $\times$20 magnification. To evaluate the shear bond strength, 60 teeth were divided into five groups of twelve teeth each. The experimental teeth were ground horizontally below the dentinoenamel junction, so that no enamel remained. After applying Scotchbond Multi-Purpose on the dentin surface, composite resin was applied in the shape of cylinder. The cylinder was 4mm in diameter and 2mm in thickness. Shear bond strength was measured using Instron with a cross-head speed of 0.5mm/min. After shear bond strength measurement, mode of failure was evaluated with a stereomicroscope at $\times$30 magnification. All data were statistically analyzed by One Way ANOVA and Student-Newman-Keuls method. The correlation between microleakage and shear bond strength was analyzed by linear regression. The results of this study were as follows ; 1. In non-thermocycling group, the leakage value of Z100 was significantly lower than those of flowable composite resins at the enamel and dentin margin, margin, except that Revolution showed the lower leakage value than that of Z100 at the dentin margin (p<0.05). 2. In thermocycling group, the leakage values of Z100 and Ultraseal XT Plus were lower than those of other subgroup at the enamel and dentin margin, except that Flow-It showed the lower leakage value than that of Ultraseal XT Plus at the dentin margin (p<0.05). 3. The leakage value of Z100 and Ultraseal XT Plus in thermocycling group were not higher than that in non-thermocycling group at the enamel margin. The leakage value of Z100 in thermocycling group was not higher than that in non-thermocycling group at the dentin margin (p<0.05). 4. As for the shear bond strength measurement, there were no statistically significant differences among groups (p<0.05). The shear bond strengths given in descending order were as follows: Z100(16.81$\pm$2.98 MPa), Flow-It(14.8$\pm$4.43 MPa), Aeliteflo(14.34$\pm$3.69 MPa), Revolution(13.46$\pm$4.23 MPa), Ultraseal XT Plus(12.83$\pm$3.16 MPa). 5. Failure modes of all specimens were adhesive failures. 6. There was no correlation between microleakage and shear bond strength.

  • PDF

The influence of occlusal loads on stress distribution of cervical composite resin restorations: A three-dimensional finite element study (교합력이 치경부 복합레진 수복물의 응력분포에 미치는 영향에 관한 3차원 유한요소법적 연구)

  • Park, Chan-Seok;Hur, Bock;Kim, Hyeon-Cheol;Kim, Kwang-Hoon;Son, Kwon;Park, Jeong-Kil
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.3
    • /
    • pp.246-257
    • /
    • 2008
  • The purpose of this study was to investigate the influence of various occlusal loading sites and directions on the stress distribution of the cervical composite resin restorations of maxillary second premolar, using 3 dimensional (3D) finite element (FE) analysis. Extracted maxillary second premolar was scanned serially with Micro-CT (SkyScan1072; SkyScan, Aartselaar, Belgium). The 3D images were processed by 3D-DOCTOR (Able Software Co., Lexington, MA, USA). HyperMesh (Altair Engineering, Inc., Troy, USA) and ANSYS (Swanson Analysis Systems, Inc., Houston, USA) was used to mesh and analyze 3D FE model. Notch shaped cavity was filled with hybrid (Z100, 3M Dental Products, St. Paul, MN, USA) or flowable resin (Tetric Flow, Vivadent Ets., FL-9494-Schaan, Liechtenstein) and each restoration was simulated with adhesive layer thickness ($40{\mu}m$). A static load of 200 N was applied on the three points of the buccal incline of the palatal cusp and oriented in $20^{\circ}$ increments, from vertical (long axis of the tooth) to oblique $40^{\circ}$ direction towards the buccal. The maximum principal stresses in the occlusal and cervical cavosurface margin and vertical section of buccal surfaces of notch-shaped class V cavity were analyzed using ANSYS. As the angle of loading direction increased, tensile stress increased. Loading site had little effect on it. Under same loading condition, Tetric Flow showed relatively lower stress than Z100 overall, except both point angles. Loading direction and the elastic modulus of restorative material seem to be important factor on the cervical restoration.

The Effect of Three Surface Sealants on Microleakage of Class V Composite Resin Restorations (복합레진으로 수복한 5급 와동의 미세누출에 대한 3종의 레진 표면 전색제의 효과)

  • Lee, Won-Cheol;Ryu, Jae-Jun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.2
    • /
    • pp.182-190
    • /
    • 2009
  • Statement of problem: Microleakage at the occlusal and gingival margin of Class V cavities restored with composite resin has traditionally been considered an obstacle to successful restoration. Purpose: The aim of this study was to assess the effectiveness of three different surface sealants(Fortify, Permaseal and Biscover LV) on the marginal sealing of Class V light-activated composite resin restorations(Z250). Material and methods: Forty noncarious human premolars and molars extracted within a three-month period were selected. Class V cavities with the occlusal margin in enamel and gingival margin in cementum were prepared in both buccal and lingual surfaces. The teeth, randomly assigned in four groups with twenty cavities in each group, were restored with composite resin after applying an adhesive system(Clearfil SE bond). After the finishing and polishing procedures, the restorations were covered with a specific surface sealants, except for the control samples, which were not sealed. After placing restorations, the specimens were thermocycled, and immersed in a 2% methylene blue solution for twenty four hours and sectioned longitudinally. The marginal microleakage was evaluated at the occlusal and gingival interfaces using a microscope and compared among the four groups using ANOVA test and Wilcoxon Rank-Sum test($\alpha$=0.05). Results: Statistical analysis showed that there was significantly less leakage when the surface sealants were used than there was in control group(P<.05). There were no significant differences of microleakage at occlusal and gingival margins among groups. There were no significant differences between microleakage of occlusal and gingival margins in each group. Fortify was not statistically different from control group at the gingival margin(P>.05). Conclusion: Application of surface sealants was an effective method of surface coating in reducing microleakage at occlusal and gingival margins of Class V composite resin restorations. However, it is certain that some microleakage still occurred despite the application of surface sealants, especially gingival margins.

A STUDY ON THE RELATIVE SHEAR BOND STRENGTH OF COMPOSITE RESIN TO COMPOMERS (컴포머에 대한 복합레진의 전단결합강도에 관한 연구)

  • Jeong, Song-Ran;Choi, Nam-Ki;Yang, Kyu-Ho;Kim, Seon-Mi;Song, Ho-Jun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.32 no.3
    • /
    • pp.509-516
    • /
    • 2005
  • For the purpose of comparing the bond strengths of compomers to composite resin, composite Z250, and two polyacid modified composite resin, Dyract AP and F2000, were selected and investigated using universal testing machine for measuring the shear bond strengths. Additionally, the failure modes were examined by observing the fractured surfaces of each specimen. The following results were obtained. 1. The shear bond strength of Dyract AP to Z250 were higher than those of F2000, but there was no statistically significant difference between group 1 and group 3(p>0.05), and groups using fresh compomers showed higher bond strength than those using aged compomers(p<0.05). 2. After measuring the shear bond strength of each group, it was highest in group 5 and was lowest in group 9(p<0.05). 3. Although there was no statistically significant difference, groups treated with thermocycling showed lower bond strengths than those of non-thermocycling groups. 4. Overall compomer/composite resin failures were adhesive. Cohesive failures occurred mainly in groups using bonding agent. Based on these results, the application of a bonding agent on fresh polyacid-modified resin composite increases the bond strength between polyacid-modified resin composite and composite resin. Additionally, the surface of aged polyacid-modified resin composite has to be roughened mechanically and a bonding agent has to be used in combination with composite resin.

  • PDF

A Study on the Characteristic and Manufacture Technique for the Gold wire of Phoenix-Shaped Glass Ewer by National Treasure No. 193 (국보 제193호 봉수형유리병 금사의 특성과 제작기법 연구)

  • Hwang, Hyun Sung;Yun, Eun Young
    • Journal of Conservation Science
    • /
    • v.31 no.1
    • /
    • pp.21-27
    • /
    • 2015
  • The Phoenix-shaped Glass Ewer, which is No. 193 National Treasure, was seriously damaged by a unique form of green glass pieces when excavated among a number of burial accessories of Hwangnamdaechong known to have been formed in the 5th century. While it has long been exhibited at the National Museum of Korea since its treatment for conservation treatment at conservation science laboratory in 1984, the existing adhesive materials seriously deteriorated for the 30 years, and the condition was quite unstable. The epoxy resin used as a restorative materials turned yellowing due to the light and heat so much that it was no longer able to exhibit it in a stable and effective manner. As a result, a re-treatment for conservation was conducted lately. This study focuses on the three pieces of Gold wires used to carefully wrap up the handle of the Phoenix-shaped Glass Ewer broken into three pieces, which has not been studied so far. As for the analysis method for Gold wires, SEM-EDS and Stereo Microscope were used for nondestructive analysis. First of all, the result of the SEM-EDS analysis shows that the composition was Au 91.9 wt.%-Au 92.8 w.t% and Ag 5.9 wt.%-Ag 6.5 wt.%, which indicates that it was an alloy made of Au and Ag. The production technique of Gold wires was also observed by means of optical microscopes. In general, Gold wires were manufactured by a drawing process in which a lump of gold was beaten or pulled out of a hole or by a process of twisting a gold plate. However, Gold wires separated from the handle of the Phoenix-shaped Glass Ewer did not involve any trace of twisting on the surface. Rather, fine vertical stripes were observed with the sections filled up. Hence, it is thought that this Ewer went through a drawing process and then was mended. As a result, no certain relation with the golden mending material used for the Phoenix-shaped Glass Ewer was verified. The findings above indicate that most of the existing researches on Gold wires recognized them, not as separate remains, but merely as a component of other golden remains. Thus, there has been little systematic study on the manufacturing techniques of Gold wires. The future study on Gold wires may verify the correlation between the Gold wires used to fix the handle of the Phoenix-shaped Glass Ewer, which is examined in this study, with that of golden remains in the Silla era.

Efficacy of 2 mm Videothoracoscopic Examination and Application of Fibrin Glue in Bullectomy of Primary Spontaneous Pneumothorax (원발성 자연기흉 환자에서 2mm 흉강경 검사와 기포절제술 후 Fibrin Glue 도포의 효용성)

  • 이덕헌;금동윤;박창권
    • Journal of Chest Surgery
    • /
    • v.37 no.5
    • /
    • pp.438-443
    • /
    • 2004
  • Background : The treatment strategy for urinary spontaneous pneumothorax has progressively changed with the introduction of video-assisted thoracic surgery (VATS). Recently, we modified the strategy of primary spontaneous pneumothorax. If the patient had mild dyspnea and the lung was minimally collapsed, 2 mm thoracoscopic examination was performed. If no blob or bullae was inspected, the intrathoracic air was evacuated through the 2 mm thoracoscopic troca without closed thoracostomy, and if the blob and bullae was noted, the 10 mm thoracoscopic bullecotomy was carried out immediately and also application of fibrin glue was substituted for pleural abrasion. We compared the clinical outcomes of modified treatment strategy with conventional strategy in primary spontaneous pneumothorax. Material and Method: Patients were divided into four groups. Group I (n=21) underwent 2 mm thoracoscopic examination. Group II (n=68) underwent closed thoracostomy. Group III (n=56) underwent VATS and application of fibrin glue. Group IV (n=87) underwent VATS and pleural abrasion. The duration of chest tube drainage, the duration of hospitalization and the recurrence rate were compared between group I and group II and between group III and group IV. Result: Mean age, sex, location of pneumothorax were not different in all groups. In group I, the blob or bullae were existed in 12 patients, In remaining 9 patients, the bleb or bullae was not inspected. The mean duration of hospitalization in 9 patients were 2.4 $\pm$1.0 day and in group II were 3.9$\pm$2.1 day (p=0.014). There was 1 case of recurrence among the 9 patients in group I and 26 recurrences in group II (p=0.149). The mean duration of chest tube drainage were not difference in group III and IV (group III: 2.8$\pm$1.8 day, group IV: 3.0$\pm$2.5 day). The mean duration of hospitalization was shorter in group III than group IV (group III: 5,6$\pm$2.7 day, group IV: 1.3$\pm$3.3 day)(p=0.002). There was no recurrence in group III and 7 recurrences in group IV (p=0.043). Conclusion: Our modified treatment strategy of primary spontaneous peumothorax was effective in short hospital course and low recurrence rate.