• 제목/요약/키워드: adhesive bond

검색결과 758건 처리시간 0.029초

상아질과 Gutta-Percha에 대한 근관충전용 Sealer의 결합강도의 측정 (MEASUREMENT OF ADHESION OF ROOT CANAL SEALER TO DENTINE AND GUTTA-PERCHA)

  • 허미자;유미경;이세준;이광원
    • Restorative Dentistry and Endodontics
    • /
    • 제28권1호
    • /
    • pp.89-99
    • /
    • 2003
  • The purpose of this study was to investigate the bonding of resin- based root canal sealer, AH26 when the sealer was applied as a thin layer between dentine and gutta-percha surface. In this study forty non-caries extracted human molars and resin-based root canal sealer(AH 26, DeTrey/Dentsply, Germany) were used. Disks of gutta-percha, 6mm in diameter.6mm thick (Diadent/Dentsply, Korea) for thermoplastic obturation were used and dentin surfaces were treated with 2% NaOCl(Group 1) or 2%NaOCl+17% EDTA(Group 3). Disks of gutta-Percha, 6mm in diameter.6mm thick (Diadent/Dentsply, Korea) for conventional obturation were used and dentin surface were treated with 2% NaOCl(Group 2) or 2%NaOCl+17% EDTA(Group 4). Enamel was removed by a horizontal section 1mm below the deepest portion of the central occlusal groove by using a watercooled low speed diamond saw. A second horizontal section was done around cementoenamel junction. Exposed dentin surface was cut to approximately $8{\times}8{\;}mm$ rectangular shape and was ground against 320, 400, 600 grade silicon carbide abrasive paper serially. After grinding, the dentine surface were soaked in a solution of 2% NaOCl for 30 minutes and twenty of specimens were treated with 17% EDTA solution for 1 minute. The treated specimens were washed and dried, Root canal sealer, AH26 was prepared according to the manufacture's instructions The Gutta-percha and dentin surface were coated with a thin layer of the freshly mixed seal or. The specimens were left overnight at room temperature. After their initial set, they were transferred to an incubator at $37$^{\circ}C$ for 72 h. After 72 hours, resin blocks were made. The resin block was serially sectioned vertically into stick of $1{\cdot}1mm$. Twenty sticks were prepared from each group. After that, tensile bond strength f3r each stick was measured with Microtensile Tester Failure patterns of the specimens at the interface between gutta-percha and dentin were observed under the SEM(x1000) and Stereomicroscope (LEICA M42O, Meyer Inst., TX U.S.A) at 1.25 x25 magnification. The results were statistically analysed by using a One-way ANOVA and Tukey's test. The results were as follows; 1. Tensile bond strengths($mean{\pm}SD$) were expressed with ascending order as follows: Group 1, $3.09{\pm}$ 1.05Mpa : Group 2, $6.23{\pm}1.16MPa$ : Group 3, $7.12{\pm}1.07MPa$ : Group 4, $10.32{\pm}2.06MPa$. 2. Tensile bond strengths of the group 2 and 4 used disks of gutta-percha for conventional obturation were significantly higher than that of the group 1 and 3 used fir thermoplastic obturation. (p < 0.05). 3. Tensile bond strengths of the group 3 and 4 treated with 2% NaOC1+17% EDTA were significantly higher than that of the group 1 and 2 treated with 2% NaOCl. (p < 0.05). 4. In analysis of failure patterns at the interface between sealer and gutta-percha, there were observed 49 (61%)cases of adhesive failure patterns and 31 (39%) cases of mixed failures patterns.

기계적 및 열적 피로가 교정용 접착제의 결합강도에 미치는 영향 (THE EFFECTS OF MECHANICAL AND THERMAL FATIGUE ON THE SHEAR BOND STRENGTH OF ORTHODONTIC ADHESIVES)

  • 신완철;김종성;김정기
    • 대한치과교정학회지
    • /
    • 제26권2호
    • /
    • pp.175-186
    • /
    • 1996
  • 본 연구의 목적은 기계적 및 열적피로가 전단결합강도에 미치는 영향을 알아보기위한 것이다. 3종의 비반죽형 접착제(Ortho-one, $MonoLok^2,\;System\;1^+$)로 mesh형의 금속 브라켓(Ormesh)을 교정목적으로 발거된 소구치의 법랑질면을 평탄하게 한 후 부착하고 100만회의 반복비틀림과 1,000회의 thermocycling을 가하였다. 그 후 Instron을 이용하여 전단결합강도를 측정하여 다음과 같은 결과를 얻었다. 1. 접착제의 Knoop 경도치는 thermocycling 전에는 $Monolok^2$$64.03kg/mm^2$으로 가장 크고, $System\;1^+$$31.60kg/mm^2$으로 가장 작았으며, thermocycling 후에도 $Monolok^2$$38.08kg/mm^2$로 가장 크고 $System\;1^+$$20.87kg/mm^2$로 가장 작았다. thermocycling 전후 비교시 Ortho-one, $Monolok^2,\;System\;1^+$ 모두에서 유의한 감소를 보였다(P<0.01). 2. 정적 시험군의 전단결합강도는 세 군 간에 유의한 차를 보이지 않았다(P>0.01). 3. 1,000회의 thermocycling 후의 전단결합강도는 $Monolok^2$ 군이 19.34MPa로 가장크고 Ortho-one 군이 13.66MPa로 가장 작게 나타났으며, thermocycling 전과 비교시 Ortho-one 군(P<0.01), $System\;1^+$군(P<0.05) 에서 유의 한 감소를 보였다. 4. 100만회의 반복 비틀림을 가한 후의 전단결합강도는 세 군에서 유사하였으며, 피로시험전과 비교시 세 군 모두 유의한 감소를 보이지 않았다(P>0.01). 5. 접착계면의 파절양상은 모든 군에서 실험조건에 관계없이 주로 브라켓/레진 계면에서 나타났다.

  • PDF

세라믹 브라켓 부착 시 레이저를 이용한 포세린 표면처리 효과 (The effect of using laser for ceramic bracket bonding of porcelain surfaces)

  • 안경미;손동석
    • 대한치과교정학회지
    • /
    • 제38권4호
    • /
    • pp.275-282
    • /
    • 2008
  • 본 연구는 포세린 표면에 $CO_2$ 레이저를 조사하여 세라믹 브라켓을 부착 후 전단결합강도를 측정하고, 산부식처리 및 샌드블라스트 등의 일반적인 방법을 시행하여 그 결과를 비교 분석하여 레이저 표면처리의 효과를 연구하고자 시행되었다. 90개의 포세린($8\;{\times}\;8\;{\times}\;4\;mm$) 시편을 제작하여 각각 10개씩 9개군으로 나누었다. 대조군(C)으로 아무런 표면처리를 하지 않은 글레이즈 표면을 사용하였으며, 실험군은 인산 처리군(OFA), 인산과 silane 처리군(OFA + S), 샌드블라스팅 처리군(SB), 샌드블라스팅과 silane 처리군(SB + S), 레이저 처리군(L), 레이저와 silane 처리군(L + S), 불산 처리군(HFA), 불산과 silane 처리군(HFA + S)으로 분류하였다. 만능시험기를 이용하여 전단결합강도를 측정하고 그 파절양상을 비교 분석한 결과 불산과 silane을 동시에 처리한 군에서 가장 높은 값($13.92\;{\pm}\;1.92\;MPa$)을 보였으며, 측정값은 SB + S ($10.16\;{\pm}\;1.27\;MPa$), HFA (10.09\;{\pm}\;1.07\;MPa$), L + S ($8.25\;{\pm}\;1.24\;MPa$), L ($7.86\;{\pm}\;0.96\;MPa$), OFA + S ($7.22\;{\pm}\;1.09\;MPa$), SB ($3.41\;{\pm}\;0.37\;MPa$), OFA ($2.81\;{\pm}\;0.37\;MPa$), 대조군($2.46\;{\pm}\;1.36\;MPa$) 순이었다. 브라켓 부착 시 치과용 레이저를 이용한 포세린의 표면처리 결과 전단결합강도의 값은 임상적으로 받아들여질 만한 수치를 보였으며 레이저와 silane을 동시에 처리한 군과는 통계적으로 유의할 만한 차이를 보이지 않았다(p > 0.05). 이상의 연구결과는 포세린 표면에 세라믹 브라켓 부착 시 2-watt의 $CO_2$ 레이저를 사용하여 전처리를 하는 방법은 시간절약의 관점에서 임상적으로 표면 전처리의 적절한 치료 대안이 될 수 있음을 보여주었다.

MICROLEAKAGE AND WATER STABILITY OF RESIN CEMENTS

  • Choi Sun-Young;Lee Sun-Hyung;Yang Jae-Ho;Han Jung-Suk
    • 대한치과보철학회지
    • /
    • 제41권3호
    • /
    • pp.369-378
    • /
    • 2003
  • Statement of Problem: Recently, resin cements have become more widely used and have been accepted as prominent luting cements. Current resin cements exhibit less microleakage than conventional luting cements. However, the constant contact with water and exposure to occlusal forces increase microleakage even in resin cements inevitably. Most bonding resins have been modified to contain a hydrophilic resin such as 2-hydroxyethylmethacrylate (HEMA) to overcome some of the problems associated with the hydrophobic nature of bonding resins. By virtue of these modifications, bonding resins absorb a significant amount of water, and there may also be significant stresses at bonding interfaces, which may adversely affect the longevity of restorations. Therefore the reinforcement of water stability of resin cement is indispensable in future study. Purpose: This study was conducted to examine the influence of water retention on microleakage of two resin cements over the period of 6 months. Materials and Methods: 32 extracted human teeth were used to test the microleakage of a single full veneer crown. Two resin cements with different components and adhesive properties - Panavia F (Kuraray Co., Osaka, Japan) and Super-Bond C&B (Sun Medical Co., Kyoto, Japan)- were investigated. The storage medium was the physiological saline solution changed every week for 1 month, 3 months, and 6 months. One group was tested after storage for 1 day. At the end of the each storage period, all specimens were exposed to thermocycling from $5^{\circ}C$ to $55^{\circ}C$ of 500 cycles and chewing simulation of 50,000 cycles, and then stained with 50% silver nitrate solution. The linear penetration of microleakage was measured using a stereoscopic microscope at ${\times}40$ magnification and a digital traveling micrometer with an accuracy of ${\pm}3{\mu}m$. Values were analyzed using two-way ANOVA test, Duncan's multiple range tests (DMRT). Results : Statistically significant difference of microleakage was shown in the 3-month group compared with the1-day or 1-month group in both systems (p<0.05) and there were statistically significant differences in microleakage between the 3-month group and the 6-month group in both systems (p<0.05). The two systems showed different tendency in the course of increased microleakage during 3 months. In Panavia F, microleakage increased slowly throughout the periods. In Super-Bond C&B, there was no significant increase of microleakage for 1 month, but there was statistically significant increase of microleakage for the next 2 months. For the mean microleakage for each period, in the 3-month group, microleakage of Super-Bond C&B was significantly greater than that of Panavia F. On the other hand, in the 6-month group, microleakage of Panavia F was significantly greater than that of Super-Bond C&B (p<0.05). Conclusion: Within the limitation of this study, water retention of two different bonding systems influence microleakage of resin cements. Further studies with the longer observation periods in viro are required in order to investigate water stability and the bonding durability of the resin cement. CLINICAL IMPLICATIONS Microleakage at the Cement-tooth interfaces did not necessarily result in the failure of the crowns. But it is considered to be a major factor influening the longerity of restorations. Further clinical approaches for decreasing the amount of microleakage are required.

Sealing Ability of Three Different Materials Used as Retrograde Filling

  • Park, Ji-Hoon;Kang, Seung-Bok;Choi, Yong-Hoon;Bae, Ji-Hyun
    • Journal of Korean Dental Science
    • /
    • 제5권2호
    • /
    • pp.60-67
    • /
    • 2012
  • Purpose: To test the apical leakage prevention performance of three different materials through protein leakage procedures using bovine serum albumin (BSA) and Bradford protein reagent. Materials and Methods: A total of 60 human single-rooted teeth were divided into 4 groups, and conventional root canal filling was done. The root was cut 3 mm from the apex, and a cavity was formed. Proroot MTA (MTA), Fuji II LC (GI), Fuji II LC with XP bond (GIA), and Caviton (CA) were used as experimental materials to fill the cavity in a retrograde filling manner. The extent of BSA leakage was then measured with a ultraviolet visible spectrophotometer 24, 48, and 72 hours after filling. Result: After 24 hours, among the 15 teeth of each group, 2 in MTA, 4 in GI, 3 in GIA, and 7 in CA showed leakage. After 48 hours, 3 in MTA, 5 in GI, 5 in GIA, and 10 in CA had leakage and discoloration. After 72 hours, among the 15 teeth of each group, 3 in MTA, 6 in GI, 5 in GIA, and 10 in CA showed leakage. The leakage in the CA group was greater than that in the MTA group at 48 and 72 hours based on Fisher's exact test (P=0.025), and the difference was statistically significant. Similarly, the leakage in the CA group was greater than that in the MTA group over time based on the Kaplan-Meier survival estimate (P=0.011), and the difference was statistically significant. Conclusion: Glass ionomer, glass ionomer after adhesive application, and MTA all showed leakage. Caviton showed greater leakage compared to MTA 48 and 72 hours after filling, and the difference was statistically significant; thus suggesting that Caviton is not appropriate as retrograde filling material considering its sealing ability.

Modeling of nonlinear cyclic response of shear-deficient RC T-beams strengthened with side bonded CFRP fabric strips

  • Hawileh, Rami A.;Abdalla, Jamal A.;Tanarslan, Murat H.;Naser, Mohannad Z.
    • Computers and Concrete
    • /
    • 제8권2호
    • /
    • pp.193-206
    • /
    • 2011
  • The use of Carbon Fiber Reinforced Polymers (CFRP) to strengthen reinforced concrete beams under bending and shear has gained rapid growth in recent years. The performance of shear strengthened beams with externally bonded CFRP laminate or fabric strips is raising many concerns when the beam is loaded under cyclic loading. Such concerns warrant experimental, analytical and numerical investigation of such beams under cyclic loading. To date, limited investigations have been carried out to address this concern. This paper presents a numerical investigation by developing a nonlinear finite element (FE) model to study the response of a cantilever reinforced concrete T-beam strengthened in shear with side bonded CFRP fabric strips and subjected to cyclic loading. A detailed 3D nonlinear finite element model that takes into account the orthotropic nature of the polymer's fibers is developed. In order to simulate the bond between the CFRP sheets and concrete, a layer having the material properties of the adhesive epoxy resin is introduced in the model as an interface between the CFRP sheets and concrete surface. Appropriate numerical modeling strategies were used and the response envelope and the load-displacement hysteresis loops of the FE model were compared with the experimental response at all stages of the cyclic loading. It is observed that the responses of the FE beam model are in good agreement with those of the experimental test. A parametric study was conducted using the validated FE model to investigate the effect of spacing between CFRP sheets, number of CFRP layers, and fiber orientation on the overall performance of the T-beam. It is concluded that successful FE modeling provides a practical and economical tool to investigate the behavior of such strengthened beams when subjected to cyclic loading.

금합금과 Ni-Cr 합금의 납착부 인장강도 (TENSILE BOND STRENGTH OF SOLDER JOINT BETWEEN GOLD ALLOY AND NICKEL-CHROMIUM ALLOY)

  • 정준호;최현미;최정호;안승근;송광엽;박찬운
    • 대한치과보철학회지
    • /
    • 제34권1호
    • /
    • pp.143-150
    • /
    • 1996
  • The purpose of this study was to evaluate the tensile strength of solder joint between gold alloy and nickel-chromium alloy. The specimens were made with type III gold alloys and Ni-Cr-Be alloy and Degular Lot 2 solder. Eighteen paired specimens were made, and subdivided into three groups. Group I specimens were gold alloy-gold alloy combination, Group II specimens were gold alloy-Ni-Cr alloy combination, Group III specimens were Ni-Cr alloy-Ni-Cr alloy combination. Solder block were made with solder investment(Degussa A,G, Germany) and stored in room temperature for 24 hours. To reduce the formation of metallic oxide and increase wetting properties, flux was used before preheating and soldering procedure. The specimens were preheated at $650^{\circ}C$ and flux were applied again and gas-oxygen torch was used to solder the specimen. All soldered specimens were subjected to a tensile force in the Instron universal testing machine : the crosshead speed was 1 mm/mim. Tensile strength values of three soldered joint groups were 1. Gold alloy-Gold alloy solder joint : $$48.8kg/mm^2$$ 2. Gold alloy-Ni-Cr alloy solder joint : $$30.9kg/mm^2$$ 3. Ni-Cr alloy-Ni-Cr alloy solder joint : $$31.8kg/mm^2$$ The microscopic examination of fracture site showed cohesive and combination fracture modes in gold alloy specimens, but showed all adhesive fracture modes in Ni-Cr alloy containing specimens.

  • PDF

프리프레그 제작용 에폭시 수지.경화제.경화촉진제 혼합비 변화에 따른 FRMLs의 피로거동 특성 (The Mixture Ratio Effect of Epoxy Resin, Curing Agent and Accelerator on the Fatigue Behavior of FRMLs)

  • 송삼홍;김철웅
    • 대한기계학회논문집A
    • /
    • 제25권4호
    • /
    • pp.592-601
    • /
    • 2001
  • Fiber reinforced metal laminates(FRMLs) are new types of hybrid materials. FRMLs consists of high strength metal(Al 5052-H34) and laminated fiber with structural adhesive bond. The mixture ratio effect of epoxy resin$.$curing agent$.$accelerator on the fatigue behavior of FRMLs was investigated in this study. The epoxy, diglycidylether of bisphenol A(DGEBA), was cured by methylene dianiline(MDA) with or without an accelerator(K-54). Eight different kinds of resin mixture ratios were selected for the test ; five kinds of FRMLs(1) and three others of FRMLs(2). The relationship between da/dN and ΔK with variation of resin mixture ratio was studied. FRMLs(1) and FRMLs(2) indicated approximately 2 times and 2.2 times more improved maximum bending strengths in comparison with those of Al 5052-H34. The resin mixture ratio <1:1> in case of FRMLs(1) indicated the maximum fatigue life, while the resin mixture ratio <1:1:0.2> in case of FRMLs(2) indicated the maximum fatigue life. As results, FRMLs(2) turned out to have more effective characteristics on the fatigue properties and the bending strength than those of FRMLs(1).

Die spacer의 두께에 따른 복합레진 inlay의 치은 변연부 미세누출 및 접착양태에 관한 연구 (GINGIVAL MARGIAL LEAKAGE AND BONDING PATTERN OF THE COMPOSITE RESIN INLAY ACCORDING TO VARIOUS THICKNESS OF DIE SPACER)

  • 박태일;신동훈;홍찬의
    • Restorative Dentistry and Endodontics
    • /
    • 제20권1호
    • /
    • pp.152-163
    • /
    • 1995
  • This experiment was performed to observe the adhesion pattern and microleakage in the gingival margin according to variation in the resin cement thickness which results from thickness of Die spacer. which is considered to effect the adaptability of the composite resin inlays. Clearfil CR inlays were fabricated on stone models with CR Sep applicated once and Nice fit twice, 4 times, and 6 times each. After 2nd curing within the CRC-100 oven, CR inlays were cemented with CR inlay cement. Dye(2% methylene blue) penetration and adhesion pattern were evaluated after sectioning of gingival margin into :3 pieces. The results were as follows ; 1. The thickness of resin cement showed unevenchanging pattern with that of die spacer, namely, it was increased until 4 times' application of Nice-Fit but was decreased with 6 times' application of that. 2. The degree of dye penetration wasn't affected by cement thickness within a limited value. 3. Most of dye penetration was shown through the interface between cement and enamel rather than the interface between cement and CR inlay. This shows that the affinity of resin cement for CR inlay was superior to the adhesive strength with tooth structure. 4. No gap was found at the interface between enamel and cement but some showed separation between dentin and cement. It is concidered that the contraction force of cement was less than the bond strength with the enamel. 5. Lots of voids were found in the CR inlay and resin cement. There was a pooling tendency of bonding agent and cement in the axiogingival line angle portion. 6. In some specimens, cracks were shown in enamel margin. From this it could be considered that cavity preparation and surface treatment weakened the tooth structure.

  • PDF

다이아몬드 마이크로블레이드의 내구성과 절삭성능에 미치는 흑연과 MoS2의 첨가효과 (The Effect of Graphite and MoS2 on Endurance and Cutting Performance of Diamond Micro Blades)

  • 문종철;김송희
    • 한국표면공학회지
    • /
    • 제41권6호
    • /
    • pp.335-340
    • /
    • 2008
  • Cutting performance and wear behavior were studied with the diamond micro-blade of Cu/Sn bond materials containing various amount of lubricant materials such as graphite and $MoS_2$. Measurement of instantaneous electric power consumption for cutting glass workpiece at the constant velocity was conducted and proposed as a method to assess cutting efficiency. The energy consumption of micro-blade for glass cutting decreased with the content of graphite and $MoS_2$ while wear amount of blade in volume increased with the amount of lubricant addition during the dicing test. It is because that hardness, flexural strength, and fracture toughness ($K_{IC}$) reduced with the amount of lubricant addition. Blades with $MoS_2$ additive showed higher mechanical properties than those with graphite additives when the same amount of the lubricant additive in wt.% was added. Due to the lower density of graphite than $MoS_2$, higher volume fraction of graphite could result in stronger effect on lowering electric power consumption by reducing the friction between blade and work piece however increasing wear rate due to the reduction in strength and fracture toughness. Adhesive wearing mode of micro blade could be remarkably improved by the addition of graphite as well as $MoS_2$.