A STUDY ON THE EFFECTS OF THE TEMPERATURE AND HUMIDITY TO THE TENSILE BOND STRENGTH BETWEEN GLASS-IONOMER CEMENT AND COMPOSITE RESIN (온도 및 습도가 Glass-ionomer cement와 Composite resin의 접착강도에 미치는 변화에 관한 연구)

  • Chung, Inn-Gyo;Min, Byung-Soon
    • Restorative Dentistry and Endodontics
    • /
    • v.16 no.1
    • /
    • pp.60-73
    • /
    • 1991
  • The purpose of this study is to evaluate the effects of etching time, environmental temperature and humidity on the adhesion of composite resin to glass-ionomer cement. Two chemical cure composite resins (Clearfil F II and Microrest AP) and two glass-ionomer cements (Fuji ionomer Type I and KET AC-CEM) were used as the experimental materials. The experiment is performed in 3 stages: The first stage is to bond composite resins to glass-ionomer cements, and the surface was not etched, and etched for 20 seconds, 40 seconds, and 60 seconds. Then specimens are stored in distilled water at $37^{\circ}C$ for 24 hours to measure tensile strength. The second stage is to choose the one group that had the highest tensile strength from the first stage and prepare two experimental groups: One group with composite resin bonded to glass-ionomer cement without etching and bonding agent application and the other with composite resin bonded to glass-ionomer cement with etching but without any bonding agent application. The specimens are stored in distilled water at $37^{\circ}C$ for 24 hours and tensile strength is measured. The third stage is to choose group that had the highest tensile strength from the first stage experiment, and bond composite resin to glass-ionomer cement at $24^{\circ}C$ 44%, $30^{\circ}C$ 44%, $30^{\circ}C$ 80%, and $32^{\circ}C$ 92%. The storage time of specimens is to bond immediately after storage, then changed to 30 sec., 60 sec., and 120 sec.. Specimens are stored in distilled water at $37^{\circ}C$ for 24 hours and their tensile strength are measured again. The following results were obtained: 1. As the etching time increases, the tensile bond strength between glass-ionomer cement and composite resin increase, and the tensile bond strength is the highest when acid etched for 60 minutes (P < 0.05). 2. After acid etching for 60 minutes, the tensile strength of the group with bonding agent was stronger than that without bonding agent application (P < 0.05). 3. The tensile strength of Clearfil F II was stronger than that of Microrest AP. 4. It was observed that the tensile bond strength is not affected by different storage time with different temperature and humidity. 5. As the humidity was increased, the tensile bond strength between glass-ionomer cement and composite resin decreased (P < 0.05).

  • PDF

Pre-treatment condition and Curing method for Fabrication of Al 7075/CFRP Laminates (Al 7075/CFRP 적층 복합재료 제조를 위한 전처리 조건과 경화방법 연구)

  • 이제헌;김영환
    • Composites Research
    • /
    • v.13 no.4
    • /
    • pp.42-53
    • /
    • 2000
  • A study has been made to establish an optimum condition in the surface treatment and curing method that is important for the fabrication of Al 7075/CFRP laminates. PAA(Phosphoric Acid Anodizing) provided a good adhesive strength and FPL(Sulfuric / Sodium Dichromate Acid Etching) had a similar adhesive strength with PAA. On the other hand, the poor adhesive strength was shown on vapor degrease and CAA(Chromic Acid Anodizing). By using the atomic force microscope(AFM), it was found that the PAA oxide surface obviously had a greater degree of microroughness as compared to vapor degrease, CAA and FPL treated surfaces. These results support the concept of a mechanical interlocking of the adhesive with-in the oxide pores as the predominant adhesion mechanism. In curing methods, the adhesive strength of co-curing method was higher than that of secondary curing method. With respect to stability of specimen shape, the secondary curing method was better than co-curing method. DMA(Dynamic Mechanical Analysis) test revealed $T_g$ in curing times over 60 min is nearly same, so it is estimated they will have similar degree of curing and joint durability in using FM300M adhesive film.

  • PDF

Wear Characteristics of Cylinder-Liner Materials for Diesel Engine at Elevated Temperature (디젤엔진용 실린더 라이너 소재의 고온 마모특성)

  • Kim, Jin-Yeol;Kim, Jae-Hoon;Oh, Kwang-Keun;Lee, Seung-Hak;Chang, Joon-Yong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.11
    • /
    • pp.1131-1136
    • /
    • 2015
  • In a diesel engine, the wear of the cylinder liner occurs because of the continuous reciprocating motion of the piston ring. This wear reduces the performance of the diesel engine and shortens its service life. This study evaluated the wear characteristics of GT metal and a conventional metal used for cylinder liners using a ship's diesel engine. Wear tests were performed at temperatures of $25^{\circ}C$, $175^{\circ}C$, and $325^{\circ}C$, and under loads of 10 N, 30 N, and 50 N. The amount of wear, specific wear rate, and friction coefficient were evaluated for each condition. To analyze the wear mechanism, observations were made on an SEM. In the case of both metals, abrasive and adhesion wear occurred on the wear surfaces at room temperature, and corrosion wear was observed at high temperatures. The amount of wear and the specific wear rate of the GT metal were lower than those of the conventional metal at all temperatures, and hence it can be concluded that the wear characteristics of the GT metal are much better.

The Study on the Development of Environmental-friendly Surface Material Using Condensed Tannin (축합형 탄닌을 이용한 친환경 건축마감재 개발에 관한 연구)

  • Jo, Jae-Min;Park, Moon-Soo;Chung, Kyung-Ho
    • Elastomers and Composites
    • /
    • v.45 no.3
    • /
    • pp.199-205
    • /
    • 2010
  • Medium-density fiberboard (MDF) is widely used as an indoor building materials. However, formaldehyde resins, commonly used to bind MDF together, emit formaldehyde and other volatile organic compounds that cause health risk at sufficient concentration. In this study, condensed tannin having formaldehyde absorption ability was used to solve the problem of formaldehyde emission generated from surface material. The synthesis of melamine-formaldehyde resin and reaction of melamine-formaldehyde and condensed tannin were analyzed by FT-IR spectrum. Also surface properties, such as shear force, impact strength, tape adhesion, pencil hardness and gloss retention were measured. Free formaldehyde analysis was performed to analyze remaining unreacted formaldehyde. According to the results, the optimum shear force and impact strength could be obtained by 10 wt.% usage of condensed tannin. In cases of pencil hardness and gloss retention, the optimum properties could be obtained at 20 wt.% of condensed tannin. The amounts of formaldehyde emission of surface material containing 20 wt.% of condensed tannin was 59 ${\mu}g/m^2{\cdot}h$. The amounts of formaldehyde emission could be reduced 3 times by using 20 wt.% of condensed tannin.

A STUDY ON OSTEOBLAST-LIKE CELL RESPONSES TO SURFACE-MODIFIED TITANIUM

  • Hong Min-Ah;Kim Yung-Soo;Kim Chang-Whe;Jang Kyung-Su;Lee Jae-Il
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.3
    • /
    • pp.300-318
    • /
    • 2003
  • Statement of problem: The success of implants depends on intimate and direct contact of implant material on bone tissue and on functional relationship with soft tissue contact. Creation and maintenance of osseointegration depend on the understanding of the tissue's healing, repairing, and remodeling capacity and these capacities rely on cellular behavior. Altering the surface properties can modify cellular responses such as cell adhesion, cell motility, bone deposition, Therefore, various implant surface treatment methods are being developed for the improved bone cell responses. Purpose: The purpose of this study was to evaluate the responses of osteoblast-like cells to surface-modified titanium. Materials and Methods: The experiment was composed of four groups. Group 1 represented the electropolished surface. Group 2 surfaces were machined surface. Group 3 and Group 4 were anodized surfaces. Group 3 had low roughness and Group 4 had high roughness. Physicochemical properties and microstructures of the discs were examined and the responses of osteoblast-like cells to the discs were investigated. The microtopography was observed by SEM. The roughness was measured by three-dimension roughness measuring system. The microstructure was analyzed by XRD, AES. To evaluate cell responses to modified titanium surfaces, osteoblasts isolated from calvaria of neonatal rat were cultured. Cell count, morphology, total protein measurement and alkaline phosphatase activities of the cultures were examined. Results and Conclusion: The results were as follows 1. The four groups showed specific microtopography respectively. Anodized group showed grain structure with micropores. 2. Surface roughness values were, from the lowest to the highest, electropolished group, machined group, low roughness anodized group, and high roughness anodized group. 3. Highly roughened anodized group was found to have increased surface oxide thickness and surface crystallinity. 4. The morphology of cells, flattened or spherical, were different from each other. In the electropolished group and machined group, the cells were almost flattened. In two anodized groups, some cells were spherical and other cells were flattened. And the 14 day culture cells of all of the groups were nearly flattened due to confluency. 5. The number of attached cells was highest in low roughness anodized group. And the machined group had significantly lower cell count than any other groups(P<.05). 6. Total protein contents showed no difference among groups. 7. The level of alkaline phosphatase activities was higher in the anodized groups than electropolished and machined groups(P<.05).

Characterization of Cement Mortar with Plastic Fine Aggregates (플라스틱 잔골재에 의한 시멘트 모르타르 기초 물성 평가)

  • Lee, Jun;Kim, Kyung-Min;Cho, Young-Keun;Kim, Ho-Kyu;Kim, Young-Uk
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.7 no.4
    • /
    • pp.383-388
    • /
    • 2019
  • The present study evaluated experimentally the effects of the type and content of plastic fine aggregates on cement mortar in order to utilize waste platics as raw materials of concrete. The two kinds of plastics, LLDPE and HDPE were used, and the mixing rate of plastic fine aggregates was increased 0, 25, 50, 75, 100%. The mortar of LLDPE fine aggregate and HDPE fine aggregate showed similar tendency in flow and material separation resistance, density and water absorption, compressive strength and flexural strength by age. The flowability of mortar mixed with plastic fine aggregates was increased up to 50% but decreased at 75% or more. The material separation resistance of mortar with plastic fine aggregates was also dramatically decreased. On the other hand, due to the low density of plastics, the density of mortar decreased with the mixing of plastic fine aggregates. Due to the low adhesion between plastic fine aggregates and cement, the compressive strength by age was decreased in proportion to the mixing ratio of plastic aggregate, but the flexural strength of each age decreased with maintaining a certain level at 50% or more of plastic fine aggregate content.

A theoretic study about western traditional wallpaper hanging (서양의 전통도배에 관한 이론적 고찰)

  • Lim, Sun-Yang
    • Archives of design research
    • /
    • v.19 no.2 s.64
    • /
    • pp.207-216
    • /
    • 2006
  • Even though the notion exists that wall paper has got a short durability for interior decoration in terms of paper's nature, it can be the most important element among the modern dosing wall papering because of the variation of the walls visual effect. Wall paper hasn't been preserved well according to the paper's character and official records haven't been done well. So, by studying a case in which a room is maintained well, seeing various commercial samples which were used for an advertisement and reading several booklets it is possible to study historical evidence. In regard to wall paper and Papering. data, the commercial historic nature of the traditional wall papering has been recognized again in order to study the root of the technical and commercial background. In theory, the historic background research of traditional wall paper in the past is said to have established its theoretical system and the development of modern wall papering in the middle of Britain in 18th century. Through the theoretical study of wall papering, the following things have been researched: handling don the method of the traditional wall papering and lining paper, stylization of pattern by using the method of continual linking, subdivision of commercial cost and specialization of wallpaper, handing down the past traditional adhesion method, the origin of string wallpaper, utility of traditional wallpaper and its various abilities, the change from the face to face linking to duplicated linking, the development of DIY products by women's wallpaper selections. Put against other materials, wallpaper remains the most popular and preferable product for managing a wall and provides a decorative, wall dosing technique. This study can estimate the source of wallpapering history in order to create a systemic approach towards the future's wallpaper industry. This is very important data in order to establish a theoretical system of traditional wallpapering according to its historical research about wallpapering skills and its commercial aspect.

  • PDF

Patch Graft of the Canine Esophagus (식도이식에 관한 실험적 연구)

  • Ha, Gye-Sik
    • Journal of Chest Surgery
    • /
    • v.2 no.2
    • /
    • pp.167-167
    • /
    • 1969
  • Two groups of esophagus graft were done in canine esophagus in 34 adult mongrel dogs. For the first group segmental replacement graft was done with fresh autologous pericardium tube, and for the second, patch graft was done utilizing fresh autologous pericardium, fresh homologous pericardium,and dacron piece. All eight dogs in the first segmental replacement graft group died 2 to 5 days after operation with severe empyema caused by anastomosis disruption. Among 26 patch graft dogs 2 died during operation and 7 died 13 to 18 days after operation. For the 17 long-term patch grafted survivors esophagography and postoperative weight check were done. Postoperative stool was collected and examined for dacron patch excretion. One, two, three, and four months postoperative long-term survivors were sacrificed to obtain specimens in each group respectively and the following observations were made.I. Survival; Autologous pericardium patch group showed no mortality but in homologous pericardium and dacron patch group only two thirds were long-term survivors. II. Postoperative swallowing; There was no case which demonstrated postoperative dysphagia. About half of the cases showed postoperative weight increase and in only 3 cases weight decrease followed operation. III. Dacron patch was excreted in the stool 8 to 23 days after operation. Animals which excreted dacron patch up to 9 days after operation all died of empyema due to anastomosis disruption.IV. Postoperative esophagogram; All esophagograms in each group showed no leakage of barium, no passage disturbances and no remarkable stenotic signs.V. Morphological findings; [A] Macroscopical findings; In one month group specimens of each group dense adhesion with surrounding structures was noted and luminal surface was smooth with contraction of the patched area. In two month groups anastomosis sutures were still exposed but patched area showed lesser abnormality. In three to four months groups sutures were covered completely and patched area showed only very slight signs of contraction. [B] Microscopic findings; In one month group luminal surface of the replaced tissue [transplanted tissue] showed almost complete epithelial covering that is composed of several layers of squamous cells with no evidence of keratinization. Basement membrane was also well distinct throughout. Slight to minimal inflammatory cells comprising of large mononuclears, lymphocytes and plasma cells were observed in the subepithelial fibrous stroma consisted entirely of loose fibrous tissue containing many newly formed capillaries and fibroblastic proliferation. Scattered suture granulomas were found, few of which became acutely inflamed. In two months group repairing process progressed with lesser degree of inflammatory cell infiltration and young capillary proliferation. Fibrous tissue was more matured showing even focal collagenization.Suture granuloma persisted but with lesser reactive changes. Epithelial covering was that of a mature non-keratinizing stratified squamous epithelium. In three and four months groups the replaced area showed essentially similar histological findings. However, subepithelial stroma still consisted entirely of connective tissue without evidence of smooth muscle regeneration. In this group, inflammatory cell infiltration was minimal or negligible. Among these patch materials autologous pericardium group showed the most satisfactory repairing process.The above mentioned results may signify the feasibility of autogenous pericardium patch graft in clinical esophageal surgery.

Patch Graft of the Canine Esophagus (식도이식에 관한 실험적 연구)

  • 하계식
    • Journal of Chest Surgery
    • /
    • v.2 no.2
    • /
    • pp.168-186
    • /
    • 1969
  • Two groups of esophagus graft were done in canine esophagus in 34 adult mongrel dogs. For the first group segmental replacement graft was done with fresh autologous pericardium tube, and for the second, patch graft was done utilizing fresh autologous pericardium, fresh homologous pericardium,and dacron piece. All eight dogs in the first segmental replacement graft group died 2 to 5 days after operation with severe empyema caused by anastomosis disruption. Among 26 patch graft dogs 2 died during operation and 7 died 13 to 18 days after operation. For the 17 long-term patch grafted survivors esophagography and postoperative weight check were done. Postoperative stool was collected and examined for dacron patch excretion. One, two, three, and four months postoperative long-term survivors were sacrificed to obtain specimens in each group respectively and the following observations were made. I. Survival; Autologous pericardium patch group showed no mortality but in homologous pericardium and dacron patch group only two thirds were long-term survivors. II. Postoperative swallowing; There was no case which demonstrated postoperative dysphagia. About half of the cases showed postoperative weight increase and in only 3 cases weight decrease followed operation. III. Dacron patch was excreted in the stool 8 to 23 days after operation. Animals which excreted dacron patch up to 9 days after operation all died of empyema due to anastomosis disruption. IV. Postoperative esophagogram; All esophagograms in each group showed no leakage of barium, no passage disturbances and no remarkable stenotic signs. V. Morphological findings; [A] Macroscopical findings; In one month group specimens of each group dense adhesion with surrounding structures was noted and luminal surface was smooth with contraction of the patched area. In two month groups anastomosis sutures were still exposed but patched area showed lesser abnormality. In three to four months groups sutures were covered completely and patched area showed only very slight signs of contraction. [B] Microscopic findings; In one month group luminal surface of the replaced tissue [transplanted tissue] showed almost complete epithelial covering that is composed of several layers of squamous cells with no evidence of keratinization. Basement membrane was also well distinct throughout. Slight to minimal inflammatory cells comprising of large mononuclears, lymphocytes and plasma cells were observed in the subepithelial fibrous stroma consisted entirely of loose fibrous tissue containing many newly formed capillaries and fibroblastic proliferation. Scattered suture granulomas were found, few of which became acutely inflamed. In two months group repairing process progressed with lesser degree of inflammatory cell infiltration and young capillary proliferation. Fibrous tissue was more matured showing even focal collagenization. Suture granuloma persisted but with lesser reactive changes. Epithelial covering was that of a mature non-keratinizing stratified squamous epithelium. In three and four months groups the replaced area showed essentially similar histological findings. However, subepithelial stroma still consisted entirely of connective tissue without evidence of smooth muscle regeneration. In this group, inflammatory cell infiltration was minimal or negligible. Among these patch materials autologous pericardium group showed the most satisfactory repairing process. The above mentioned results may signify the feasibility of autogenous pericardium patch graft in clinical esophageal surgery.

  • PDF

Characteristic of Ru Thin Film Deposited by ALD

  • Park, Jingyu;Jeon, Heeyoung;Kim, Hyunjung;Kim, Jinho;Jeon, Hyeongtag
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.78-78
    • /
    • 2013
  • Recently, many platinoid metals like platinum and ruthenium have been used as an electrode of microelectronic devices because of their low resistivity and high work-function. However the material cost of Ru is very expensive and it usually takes long initial nucleation time on SiO2 during chemical deposition. Therefore many researchers have focused on how to enhance the initial growth rate on SiO2 surface. There are two methods to deposit Ru film with atomic layer deposition (ALD); the one is thermal ALD using dilute oxygen gas as a reactant, and the other is plasma enhanced ALD (PEALD) using NH3 plasma as a reactant. Generally, the film roughness of Ru film deposited by PEALD is smoother than that deposited by thermal ALD. However, the plasma is not favorable in the application of high aspect ratio structure. In this study, we used a bis(ethylcyclopentadienyl)ruthenium [Ru(EtCp)2] as a metal organic precursor for both thermal and plasma enhanced ALDs. In order to reduce initial nucleation time, we use several methods such as Ar plasma pre-treatment for PEALD and usage of sacrificial RuO2 under layer for thermal ALD. In case of PEALD, some of surface hydroxyls were removed from SiO2 substrate during the Ar plasma treatment. And relatively high surface nitrogen concentration after first NH3 plasma exposure step in ALD process was observed with in-situ Auger electron spectroscopy (AES). This means that surface amine filled the hydroxyl removed sites by the NH3 plasma. Surface amine played a role as a reduction site but not a nucleation site. Therefore, the precursor reduction was enhanced but the adhesion property was degraded. In case of thermal ALD, a Ru film was deposited from Ru precursors on the surface of RuO2 and the RuO2 film was reduced from RuO2/SiO2 interface to Ru during the deposition. The reduction process was controlled by oxygen partial pressure in ambient. Under high oxygen partial pressure, RuO2 was deposited on RuO2/SiO2, and under medium oxygen partial pressure, RuO2 was partially reduced and oxygen concentration in RuO2 film was decreased. Under low oxygen partial pressure, finally RuO2 was disappeared and about 3% of oxygen was remained. Usually rough surface was observed with longer initial nucleation time. However, the Ru deposited with reduction of RuO2 exhibits smooth surface and was deposited quickly because the sacrificial RuO2 has no initial nucleation time on SiO2 and played a role as a buffer layer between Ru and SiO2.

  • PDF