Fault Detection and Isolation System for DC motor driven Centrifugal Pump-Pipe Systems: Parity Relation Approach (직류전동기 구동 원심펌프-파이프 계통의 고장검출진단시스템: 등가관계 접근법)

  • Park, Tae-Geon;Ryu, Ji-Su;Lee, Kee-Sang
    • Proceedings of the KIEE Conference
    • /
    • 1998.07b
    • /
    • pp.819-821
    • /
    • 1998
  • This paper deals with a method or a residual generation for fault isolation in a centrifugal pump with a water circulation system, driven by a speed controlled dc motor. It is based on parity relations derived from the moving-average model of the system and is used to identify sensor faults and two possible brush and impeller faults, where the former is dealt with additive faults, while the latter characterized as discrepancies between the nominal and actual plant parameters of the system is modelled by multiplicative faults. We will represent the propagation of this uncertainty to the model matrices by the approximate handling of partial derivatives of polynomials. With multiplicative faults, the transformation matrix implemented in the residual generator are calculated on-line. The simulation studies demonstrate that small changes of the system can be detected and diagnosed by using the method.

  • PDF

Experinces with Soft Clay Improvement in the Bangkok plain

  • O, P-R
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1997.06c
    • /
    • pp.1.1-16
    • /
    • 1997
  • This lecture summarizes the progress of the development of the different ground improvement techniques in Bangkok Plain and is reviewed in relation to the extensive deep wen pumping and the resulting piezometric drawdown at deeper depths. Case records of test embankments with sand drains, sand wicks and PVD are presented to inustrate the effectiveness of different types of vertical drains with surcharge. The use of prefsbicated drain seems more superior than the other types of sand drain. Construction of test embaxlkment, criteria for PVD selection and relevant laboratory testing techniques are discussed for formulating the specif'ication. Alternative teckuuque, such in, the use of deep chemical mixing is reviewed in terms of the efficiency of cement, lime and flyash as additive. Vacuum pre-loading with surcharge and elctro- osmotic consolidation are also explored as possible tectmiques to improve the engineering properties of soft Bangkok clay.

  • PDF

Multi-resolutional Representation of B-rep Model Using Feature Conversion (특징형상 변환을 이용한 B-rep모델의 다중해상도 구현)

  • 최동혁;김태완;이건우
    • Korean Journal of Computational Design and Engineering
    • /
    • v.7 no.2
    • /
    • pp.121-130
    • /
    • 2002
  • The concept of Level Of Detail (LOD) was introduced and has been used to enhance display performance and to carry out certain engineering analysis effectively. We would like to use an adequate complexity level for each geometric model depending on specific engineering needs and purposes. Solid modeling systems are widely used in industry, and are applied to advanced applications such as virtual assembly. In addition, as the demand to share these engineering tasks through networks is emerging, the problem of building a solid model of an appropriate resolution to a given application becomes a matter of great necessity. However, current researches are mostly focused on triangular mesh models and various operators to reduce the number of triangles. So we are working on the multi-resolution of the solid model itself, rather than that of the triangular mesh model. In this paper, we propose multi-resolution representation of B-rep model by reordering and converting design features into an enclosing volume and subtractive features.

Effects of pH, Alkalinity, Chloride Ion on the Copper Pipe Corrosion (동관에서 pH, 알칼리도, 염소이온이 부식에 미치는 영향)

  • Jo, Kwan-Hyung;Kim, Sun-Il;Woo, Dal-Sik
    • Journal of Environmental Health Sciences
    • /
    • v.33 no.1 s.94
    • /
    • pp.43-48
    • /
    • 2007
  • This study investigated the effects of pH, alkalinity, and chlorine ion which are important water quality impact factors to the corrosion in the simulated distribution system where the copper pipe is affixed. The result shows that pitting index was increased as the alkalinity and chloride ion increase in the distilled water, but there was no relation to pH. Actually the uniform corrosion rate was decreased as the pH increase with the laboratory tap water. In conclusion, it is necessary to control the pH which stands above minimum 7.5 to prevent pitting corrosion in the copper pipe. Consequently, comprehensive research about the effect of lime soda($Ca(OH)_2$) which was used as a coagulation additive in the water treatment plant to pipe corrosion must be accomplished additionally.

Line-edge Detection using 2-D Wavelet Function in Degraded Image by AWGN (AWGN에 훼손된 영상에서 2-D 웨이브렛 함수를 이용한 라인-에지 검출)

  • 배상범;김남호
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.8 no.3
    • /
    • pp.748-753
    • /
    • 2004
  • Edge includes variety of information about image's location and shape etc. So a lot of researches for detecting those edges have been continuing even now and at the early stage of the research, edge detection operators searched neighborhood pixels and used relation among pixels. However, these methods do not have excellent performance in the image which exists noise and can not detect edges selectively. For this reason, in this paper we detected image's line-edge element from degraded image by AWGN (additive white gaussian noise) with wavelet function which is independent of line's width.

A Time-Series Study of Ambient Air Pollution in Relation to Daily Death Count in Daejeon, 1998-2001 (대전 광역시 대기오염과 일별 사망자 수의 상관성에 관한 시계열적 연구(1998년~2001년))

  • Cho, Yong-Sung;Lee, Jong-Tae;Kim, Yoon-Shin
    • Journal of Environmental Impact Assessment
    • /
    • v.13 no.1
    • /
    • pp.9-19
    • /
    • 2004
  • This study is performed to examine the relationship between air pollution exposure and mortality in Daejeon for the years of 1998 - 2001. Daily counts of death were analyzed by general additive Poisson model, with adjustment for effects of seasonal trend, air temperature, humidity, and day of the week as confounders in a nonparametric approach. Daily death counts were associated with CO(4 day before), $O_3$(current day), $PM_10$(4 day before), $NO_2$(6 day before), $SO_2$(2 day before). Increase of $31.07{\mu}g/m^3$(interquartile range) in $PM_10$ was associated with 2.0 % (95% CI = 0.5 % - 3.5 %)) increase in the daily number of death. This effect was greater in children(less than 15 aged) and elderly(more than 65 aged). We concluded that Daejeon had 2 - 4 % increase in mortality in association with IQR in air pollutants. Daily variations in air pollution within the range currently occurring in Daejeon might have an adverse effect on daily mortality. These findings also support the hypothesis that air pollution at levels below the current ambient air quality standards of Korea except PM10, is harmful to sensitive subjects, such as children or elderly.

A Time-Series Study of Ambient Air Pollution in Relation to Daily Mortality in Incheon, 1998-2001 (인천시 대기오염과 일별 사망의 상관성에 관한 시계열적 연구 (1998년${\sim}$2001년))

  • Cho, Yong-Sung;Lee, Jong-Tae;Kim, Yoon-Shin;Hyun, Youn-Joo;Moon, Jeong-Suk
    • Journal of environmental and Sanitary engineering
    • /
    • v.18 no.3 s.49
    • /
    • pp.89-99
    • /
    • 2003
  • This study is peformed to examine the relationship between air pollution exposure and mortality in Incheon for the years of 1998 - 2001. Daily counts of death were analyzed by general additive Poisson model, with adjustment for effects of seasonal trend, air temperature, humidity, and day of the week as confounders in a nonparametric approach. Daily death counts were associated with CO(1 day before), O$_3$(2 day before), PM$_{10}$(1 day before), NO$_2$(1day before), SO$_2$(1 day before). Increase of 32.21 ${\mu}$g/m$^3$(interquartile range) in PM$_{10}$ was associated with 1.9 % (95% CI = 0.8 % - 2.9 %) increase in the daily number of death. This effect was greater in children(less than 15 aged) and elderly(more than 65 aged). We concluded that Incheon had 2 - 4 % increase in mortality in association with IQR in air pollutants. Daily variations in air pollution within the range currently occurring in Incheon might have an adverse effect on daily mortality. These findings also support the hypothesis that air pollution, at levels below the current ambient air quality standards of Korea, is harmful to sensitive subjects, such as children or elderly.

Experiment on measures of heat collection for passive solar water wall systems that provide heat storage and natural lighting control (축열과 채광조절을 겸한 자연형 태양열 수벽시스템의 집열방식별 성능실험)

  • Oh, Young-hoon;Choi, Ji-eun;Lee, Chul-sung;Yoon, Jong-ho
    • KIEAE Journal
    • /
    • v.16 no.4
    • /
    • pp.63-69
    • /
    • 2016
  • Purpose: This preliminary study investigated a potential of the water wall systems that provide heat storage and natural lighting control simultaneously. Method: In order for transparency of the water wall to be controlled, the study first proposed two measures: to adjust transparency of the water wall; to control transparency of water wall surface. The performance of two measures then was verified and compared by experiments. In addition, a trade-off between heat collect and heat storage resulting from using additive for adjusting transparency was investigated. Result: The experiment showed that the two measures are similar in performance. The investigation of trade-off relation showed the additive should have the same heat storage as the water to prevent decrease in thermal performance of the water wall. As an economical measure to control transparency of the water wall, this study suggested a measure of secondary heat transfer systems using shading device that first absorbs solar radiation and then transfers heat to the water wall. The experiment show that performance of the proposed measure is similar to controlling transparency of water wall surface. In conclusion, it is expected that the performance of the water wall can be economically maximized by using the proposed mean in terms of heating, cooling and lighting energy saving.

The Relationship of Contained Water and Coloring Rate of Thiamine Monosalts in Preparations as an Additive of Food and Formula Feed (식품 및 배합사료의 첨가제로서 치아민 모노염류의 함수량과 착색도)

  • Park, Hong-Koo
    • Applied Biological Chemistry
    • /
    • v.40 no.5
    • /
    • pp.409-415
    • /
    • 1997
  • In order to find out the relationship between contained water and coloring rate of thiamine monosalts in preparations, three kinds of thiamine monorhodanate, -monoiodide, -monobromide were manufactured and investigated as powders, granules and compressed tablets, respectively. Apparent coloring rate constants and solubility in accordance with temperature changes were measured. Nature of contained water and coloration of thiamine monosalts in preparations was examined in detail. It was thereby found that if water attached in a free state, coloration occured whose degree was approximately proportional to the quantity of such water, and a linear relation was found to hold between the logarithm of the apparent coloring rate constants and the reciprocal of the absolute temperature in granules and compressed tablets.

  • PDF

The Verification Of Green Soil Material Characteristics For Slope Protection (사면 보호를 위한 녹생토 재료 특성 검증)

  • Lee, Byung-Jae;Heo, Hyung-Seok;Noh, Jae-Ho;Jang, Young-Il
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.7 no.6
    • /
    • pp.681-692
    • /
    • 2017
  • In recent years, large-scale construction projects such as road pavement construction and new city construction have been carried out nationwide with by the expansion of social overhead facilities and base on the economic development planning, resulting in a rapid increase in artificial slope damage. The existing vegetation-based re-installation method of the slope surface greening method reveals various problems such as lack of bonding force, drying, and lack of organic matter. In this study, research was carried out using vegetation-based material and environmentally friendly soil additives, were are used in combination with natural humus, Bark compost, coco peat, and vermiculite. Uniaxial compressive strength was measured according to the mixing ratio of soil additives and the strength was analyzed. Experiments were carried out on the characteristics of the soil material to gauge the slope protection properties by using the soil compaction test method wherein the soil and the soil additive materials are mixed in relation to the soil height, the number of compaction, the compaction method (layer) and the curing condition. As a result of the experiment, excellent strength performance was demonstrated in soil additives using gypsum cement, and it satisfied vegetation growth standards by using performance enhancer and pH regulator. It was confirmed that the strength increases with the mixing of soil and soil additive, and the stability of slope protection can be improved.