• 제목/요약/키워드: actual size test

검색결과 256건 처리시간 0.027초

중년여성의 신체부위 인지유형에 따른 신체만족도와 착의 의복 스타일 (Body Cathexis and Actual Clothing Styles of Middle-aged Women According to Perception of Their Body)

  • 위은하;박우미
    • 한국의류학회지
    • /
    • 제27권9_10호
    • /
    • pp.1112-1123
    • /
    • 2003
  • This study is designed for improving wearing styles for middle-aged women who are in unsatisfactory body types and also providing the basic information about the suitable clothing designs for them. This study focuses on what kinds of body types they perceive, what the differences are between the perception of their body types and the real ones, and how the actual clothing styles can be affected by those perceived body types. This study is based on the survey of the perception of body types, the clothing styles, and the satisfaction level of body cathexis, while measuring body size of each person responded. The data were analyzed by Mean, ANOVA, Duncan-test of SPSS Win. (ver 10.1)program. The results are as follows: 1. The perception of their body types can be categorized into three clusters, the obesity, the arm & leg obesity, the slender. 2. By and large, Middle-aged women perceive their body types exactly what they we. However, they show a relatively subjective view on the upper arm girth, ankle girth, and arm length 3. The abdomen is at the lowest satisfactory part in body cathexis for the entire groups responded, and there are some differences among the perception of their body types in whole body silhouette and trunk. 4. Middle-aged women who perceive themselves as a bit slender show a tendency of having tight and revealing clothing styles, while the obese who perceived themselves wouldn't take them as appropriate dresses.

컴퓨터단층 혈관조영술에서 스텐트 사이즈의 정확한 측정을 위한 상대적 측정법의 기초연구 (Fundamental Study of Relative Measurement for Accurate Measurement of Stent Size in Computed Tomography Angiography)

  • 이승영;홍주완;강수미;김수빈;전상훈;허영철
    • 한국방사선학회논문지
    • /
    • 제13권5호
    • /
    • pp.713-720
    • /
    • 2019
  • 본 연구의 목적은 컴퓨터단층 혈관조영술에서 혈관 직경을 정확하게 측정할 수 있는 새로운 측정 방법인 상대적 측정법의 기초연구 자료를 제공하고자 한다. 비이온성 요오드 조영제를 자체 제작한 관류 팬텀에 일정한 속도로 흐르게 한 후 컴퓨터단층 혈관조영술 검사를 시행하였다. 원시 데이터를 얻은 후 다중평면재구성 및 최대강도투사법으로 영상을 재구성하였고 장비 사에서 제공하는 거리측정 장치를 사용하여 팬텀의 직경을 측정하였다. 측정법은 고식적 측정법과 본 연구에서 제안하는 상대적 측정법을 사용하였다. 관류팬텀의 평균 직경은 다중평면재구성기법과 최대강도투사법 모두에서 상대적 측정법이 기존 측정법 보다 실측에 더 가깝게 나타났다(34% VS 24%, p<0.05). 하지만 두 가지 측정법 모두 실측보다 여전히 확대된 결과를 나타내고 있음을 확인하였다. 따라서 상대적 측정 방법에 대한 추가 연구가 필요한 실정이며, 이에 본 연구가 기초 자료를 제공할 수 있을 것이라 사료된다.

Household Over-indebtedness and Financial Vulnerability in Korea: Evidence from Credit Bureau Data

  • KIM, YOUNG IL;KIM, HYOUNG CHAN;YOO, JOO HEE
    • KDI Journal of Economic Policy
    • /
    • 제38권3호
    • /
    • pp.53-77
    • /
    • 2016
  • Financial soundness in the household sector matters for financial stability and for the real economy. The level of household debt in Korea raises concern about the financial soundness of the household sector due to its size, growth rate and quality. Against this backdrop, we assess the financial vulnerability of borrowers based on an analysis of credit bureau (CB) data, in which the actual credit activities of most individuals are recorded at a high frequency in Korea. We construct over-indebtedness indicators from the CB data and then assess the predictability of forthcoming defaults. Based on the over-indebtedness indicators, we show how borrowers are distributed in terms of over-indebtedness and how the over-indebted differ from average borrowers in terms of their characteristics. Furthermore, we show how the aggregate credit risk in the household sector would change under macroeconomic distress by analyzing how each borrower's credit quality would be affected by adverse shocks. The findings of this paper may contribute to assessing household debt vulnerability and to enhancing regulatory and supervisory practices for financial stability.

  • PDF

초음파검사시 ASME와 RCC-M CODE에 따른 결함 크기측정 및 허용기준 비교평가 (The Comparison of Acceptance Criteria and Flaw Size Measurement between ASME and RCC-M Code in Ultrasonic Examination)

  • 김병철;임형택;이종포;주영상
    • 비파괴검사학회지
    • /
    • 제8권1호
    • /
    • pp.6-11
    • /
    • 1988
  • The comparison and analysis of flaw detectability, flaw sizing methods and allowable criteria in accordance with the applicable codes, ASME and RCC-M Code, in ultrasonic examination of pressure vessel in nuclear power plants were studied. Accordding to the codes, calibration blocks were made. The artificial flaws such as disc and band types in test specimens were machined. They were detected and evaluated with etch code requirements and measured values were compared with the actual flaws.

  • PDF

제지공정의 WET-END 분석을 위한 새로운 감압 탈수 초지설비(RDA)의 활용(제1보) - RDA를 활용한 종이 균일성 예측 - (Application of the Novel Test Machine, Retention Drainage Analyzer(RDA), for Wet-End Analysis of Papermaking Process (I))

  • 우이균;류정용;김용환;송봉근;조남석
    • 펄프종이기술
    • /
    • 제34권4호
    • /
    • pp.1-6
    • /
    • 2002
  • In order to simulate the actual wet-end process in papermachine, RDA, a novel handsheet former, was used and following results were obtained. While the addition of polyelectrolytes gives significant effect on fiber flocculation, increase of stock consistency influenced on the formation of RDA sheets greatly. In particular, the consistency increase from 0.3 % to 0.4% abruptly increased floe size of RDA sheet and it results in severe deterioration of paper strength. Stock consistency, therefore, should be regarded as the most important factor in the formation simulation with RDA and should be controlled as the first sequence of tuning the operating conditions of RDA to simulate correctly the target machine paper's formation.

고강도 철근콘크리트 띠철근 기둥의 구속모델 (Confined Model of High-Strength Reinforced Concrete Tied Columns)

  • 이희수;한범석;신성우;반병렬;이광수
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.923-928
    • /
    • 2002
  • Experimental and analytical study were conducted to develop the confined model of reinforced high strength concrete tied columns subjected to monotonically increasing concentric axial compression. Twenty-one large-scale columns(260$\times$260$\times$1200mm) used high strength concrete of 50 and 85MPa were fabricated to simulate an actual structural members size. Test results indicated that gains of strength and ductility of high strength concrete columns could be increased, if efficient arrangements and volumetric ratios of transverse reinforcements were provided. The proposed model satisfactorily predicted the experimental stress-strain curves for high strength concrete up to 100MPa.

  • PDF

Confining Effect of Mortar-filled Steel Pipe Splice

  • Kim, Hyong-Kee
    • Architectural research
    • /
    • 제10권2호
    • /
    • pp.27-35
    • /
    • 2008
  • Because of several advantages of mortar-filled sleeve splice in reinforced concrete buildings, this method is being applied increasingly at construction sites and various methods of the splice have been developed in Korea and other countries. In order to apply this system in the field, studies on mortar-filled sleeve splice have been mainly experimental research focused on overall structural performance. However, for understanding the structural characteristics of this splice more accurately, we need to study the confining effect of sleeve, which is known to affect bond strength between filling mortar and reinforcing bar, the most important structural elements of the bar splice. Thus, in order to examine the confinement effect of mortar-filled steel pipe sleeve splice, the present study prepared actual-size specimens of steel pipe sleeve splice, and conducted a loading. Using the test results, we analyzed how the confining effect of steel pipe sleeve affects the bond strength of this splice and obtained data for developing more reasonable methods of designing the splice of reinforcement.

케이블 포설장력 특성에 대한 실험적 고찰 (The experimental investigation on the characteristics of the cabling tension)

  • 김동훈;한진우
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 한국정보통신설비학회 2009년도 정보통신설비 학술대회
    • /
    • pp.49-53
    • /
    • 2009
  • If you are installing communications cables in the pipeline based on the kind of cable installation tension within the allowed range of the tension must be maintained. The tension of the installation affected by the cable types, cable jacketed status, cross-sectional shape of the pipeline, the substance present in the pipeline, pipeline linear, the direction of the cable is installed. Depending on the size of the cable installation tension fatal influence on the quality of communication, or, at worst, the cable can be cut. In this paper, test bed for building a pipeline and using optical cable and such cable tension was measured. Freedom of access to the pipeline used in the experiment, and installed in conjunction with the cable tension was measured. It possible for the cable installation to determine whether a duplicate, and have compared the actual measured tension value and the theoretical expression.

  • PDF

The optimum simulation and real test of double prismatic Light-guide plate for a high brightness LCD backlight unit

  • Yoon, D.K.;Park, D.S.;Oh, Y.S.;Bae, K.W.;Kim, K.H.;Lim, Y.J.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2005년도 International Meeting on Information Displayvol.II
    • /
    • pp.1503-1506
    • /
    • 2005
  • This dissertation represents method concerning high performance prism LGP design in 17 inch TFT-LCD. By means of developing LGP with total size of 8mm that has prism on both upper side and bottom side, it is superior to previous printing way in gaining high brightness. It can realize actual material simulation on prism LGP production using 17inch injection process and about 20% luminance enhancement is achieved based on such method.

  • PDF

BEM에 의한 고속전철용 방음벽의 설치 효과 예측 (The Prediction of the Efficiency of High-Speed Railway Noise Barriers by BEM)

  • 이우섭;정성수;나희승;양신추
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 춘계학술대회논문집
    • /
    • pp.1355-1359
    • /
    • 2000
  • In this study, the insertion losses of various track-side railway noise barriers are analyzed by using a two-dimensional numerical boundary element method(BEM). The BEM is implemented using two out-of-phase monopole sources for each track to represent dipole source. All model for this study is based on actual size built in Test Line of KTX. And the results suggest that vertical absorptive barrier provide as effective screening as rigid barrier which is more 0.4 m than the height of those.

  • PDF