• Title/Summary/Keyword: active pressure

Search Result 954, Processing Time 0.024 seconds

Optimum Design of a Cooling Air Cooler Heat Exchanger by Using a Response Surface Method (반응표면법을 이용한 Cooling Air Cooler 열교환기의 최적 설계)

  • Kim, Seong-Soo;Jeong, Hyo-Min;Chung, Han-Shik
    • Journal of Power System Engineering
    • /
    • v.21 no.3
    • /
    • pp.85-92
    • /
    • 2017
  • Global air traffic is forecast to grow at an average annual rate of around 5% in the next 20 years. The continuous growth of air traffic and raised environmental awareness put increasing pressure on aero engine manufacturers to reduce fuel burn and emissions. NEWAC are a new integrated program of the European Union with focus on innovative core engine concepts to achieve this problem. In this paper, Within NEWAC, active core engine configurations will be investigated. the investigation is focused on the optimal design of the CAC heat exchanger for active core. For optimal design of he CAC heat exchanger, the HTFS of basic design of heat exchanger are analyzed so as to proceed an optimization routines based on Response Surface Method(RSM) and Design of Experiment(DOE). As a result, CAC heat exchanger optimized by 1.0314 lb/s mass flow rate and 3.9058 mm TP of tube layout and 206.8181 mm height of heat exchanger and 918 tube number for heat transfer and pressure drop. We confirm the design optimization using RSM and DOE is useful on complex structure of heat exchanger.

The Lateral Earth Pressure on Rigid Retaining Wall Due to the Various Modes of Wall Movement (벽체변위에 따른 기류벽에 작용하는 토압)

  • Chae, Yeong-Su;Im, Byeong-Ju;Baek, Yeong-Sik
    • Geotechnical Engineering
    • /
    • v.1 no.1
    • /
    • pp.21-30
    • /
    • 1985
  • The reasonable static and dynamic earth pressure equations were developed by applying the Dubrova's theory and Chang's method to the following cases of wall movements; (1) Active case rotating about the top (2) Active case rotating about the bottom (3) Passive case rotating about the top (4) Passive case rotating about the bottom The equations are presented in accordance with particular wall displacements for the sand and cohesive back-fill, respectively. The results computed by the proposed equations are compared with the conventional theoretical values.

  • PDF

A Study on the Inside Contact Characteristics Between Abrasive Belt and Pulley (연삭 벨트-풀리간의 내접촉 특성에 대한 연구)

  • 김현수
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.12 no.3
    • /
    • pp.457-465
    • /
    • 1988
  • The inside contact characteristics in abrasive belt drives were investigated analytically and experimentally for (1) driver pulley contact wheel and (2) driven pulley contact wheel. The concentrated contact forces in the grinding zone divided the entire belt-pulley contact are by three distinct areas and the tangential friction forces in the active areas caused the normal forces to change, which resulted in the different belt force distribution compared with those of the ordinary flat belt drives. The experimental results for the normal pressure (belt tension) distribution were in good agreement with the theoretical results.

Role of Charges of the Surface-grafted Polymer Chains for Aqueous Lubrication at a Nonpolar Interface

  • Ron, Troels;Madsen, Jan Busk;Nikorgeorgos, Nikolaos;Lee, Seunghwan
    • Tribology and Lubricants
    • /
    • v.30 no.5
    • /
    • pp.247-255
    • /
    • 2014
  • Charged polymer chains, i.e., polyelectrolytes, are known to show superior aqueous lubricating properties compared to those of neutral polymer chains, especially in brush conformation. This is primarily because of the incorporation of a large amount of counterions within the polymer layers and the consequently increased osmotic pressure. However, this effect is active only when the polymer chains remain immobilized even under tribostress, which is not realistic for high-contact pressure tribological applications, especially when they are irreversibly immobilized on tribopair surfaces. In contrast, with free polymers, which can be included as surface-active additives in the base lubricant (water), long-term lubricating performance based on "self-healing" properties is readily expected. In order to assess whether the superior aqueous lubricating properties of polyelectrolyte chains are valid for free polymers too, this study reviews recent studies on the tribological properties of many charged biopolymer and synthetic copolymers at a nonpolar, hydrophobic interface. In contrast to the irreversibly immobilized polyelectrolyte chains, free polyelectrolyte chains show inferior aqueous lubricating properties compared to their neutral counterparts owing to charge accumulation and the consequently impeded surface adsorption on the nonpolar surface. Nevertheless, bovine submaxillary mucin (BSM), a representative biopolymer, shows a sufficiently effective surface adsorption and aqueous lubricating capabilities even at neutral pH without losing the polyanionic characteristics.

Study of Characteristics of Corona Discharge Plasma in a Wire-Cylinder Type Reactor (Wire-Cylinder형 반응로에서의 코로나 방전 플라스마의 특성 연구)

  • 박승자;박인호;고욱희
    • Journal of the Korean Vacuum Society
    • /
    • v.13 no.3
    • /
    • pp.132-138
    • /
    • 2004
  • We used the self-consistent one-dimensional model applied to FCT algorithm and FEM method in a wire-cylinder type reactor to study the characteristics of corona discharge plasma in air at the atmospheric pressure. At the pulsed do voltage and do voltage, we studied the changes of the characteristic of plasma by computing electron density profile according to the changes of voltage and the size of reactor. The changes of active radius from this result are compared with the data of Peek's. The numerical simulation results for a corona discharge plasma explain the physical mechanism of the discharge process and could be used to obtain the optimized parameters for designing the plasma reactor for pollution abatement.

Analysis of Curve Squeal Noise for Busan Metro Line 3 (부산 도시철도 3호선 차량 곡선부 스퀼소음 특성)

  • Hong, Do-Kwan;Ahn, Chan-Woo;Han, Geun-Jo;Gang, Hyeon-Uk
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.28 no.4
    • /
    • pp.427-435
    • /
    • 2011
  • This paper deals with the measurement and analysis of the squeal noise according to the curvature of rail. The squeal noise is generated by the friction between the railway with curve and the wheel. The squeal noise is a big problem in Busan Metro Line 3. If the developing panel type ANC(Active Noise Control) system which is attached to the floor can reduce 5 dB in below 500 Hz, the sound pressure level of the whole band pass can be reduced about 4-4.8 dB in squeal noise above the curvature of R400. Curve squeal noise is the intense high frequency tonal that can occur when a railway vehicle transverses a curve. The frequency range is from around 500 to almost 20,000 Hz, with noise levels up to about 15 dB in curve.

The immediate effects of 830-nm low-level laser therapy on the myofascial trigger point of the upper trapezius muscle in visual display terminal workers: A randomized, double-blind, clinical trial

  • Lee, Jung-Hoon;Lee, Sun-Min
    • International Journal of Contents
    • /
    • v.7 no.2
    • /
    • pp.59-63
    • /
    • 2011
  • The aim of our study was to evaluate the immediate effects of an 830-nm Aluminium gallium arsenide (GaAlAs) laser, by examining the changes, in pressure-pain threshold (PPT) and tenderness at 3 kg of the myofascial trigger point (MTrP) of the upper trapezius muscle in visual display terminal (VDT) workers in comparison with placebo treatment. Thirty VDT workers (13 males, 17 females) with complaints of upper trapezius muscle were recruited. All participants were given either active GaAlAs laser (830 nm wavelength, 450 mW, 9 J at point) or placebo GaAlAs laser, according to the double-blinded and placebo-controlled trial. Both active and placebo low-level laser therapy (LLLT) treatments showed no significant effect on PPT and tenderness at 3 kg. These results suggest that a higher dosage may be necessary to produce immediate effects when applying LLLT to the MTrP of relatively large muscles such as the upper trapezius muscle.

The effects of active release technique on the gluteus medius for pain relief in persons with chronic low back pain

  • Tak, Sajin;Lee, Yongwoo;Choi, Wonjae;Lee, Gyuchang
    • Physical Therapy Rehabilitation Science
    • /
    • v.2 no.1
    • /
    • pp.27-30
    • /
    • 2013
  • Objective: Low back pain is a primary of source of dysfunction and economic costs. Gluteus medius muscle co-activation and activity pattern change caused the low back pain. Active release technique (ART) is a patented, non-invasive, soft tissue treatment process that both locates and breaks down the scar tissue and adhesions. The purpose of this study was to assess the effects on chronic low back pain using ART on gluteus medius so that suggest usable treatment method for treating chronic low back pain. Design: One group pretest-posttest design. Methods: Twelve patients with chronic low back pain were participated in this study. Subjects in ART group were received 2 times a week for 3 weeks treatments with either ART on gluteus medius muscle trigger points. Outcome measures were conducted by pain intensity with a pain visual analogue scale and pressure pain threshold on gluteus medius. Results: Completion of the intervention, the visual analogue scale was decreased in ART group (p<0.05). Also pressure pain threshold was decreased in ART group (p<0.05). Conclusions: Our results suggest that the response to ART may be usable to treat low back pain. ART was presented to reduce pain level of low back in people with chronic low back pain. Further study is required to management for low back pain due to gluteus medius and more ART study.

  • PDF

Experimental Investigation of Supersonic Jet Noise Reduction Using Microjet Injection

  • Mamada, Ayumi;Watanabe, Toshinori;Uzawa, Seiji;Himeno, Takehiro;Oishi, Tsutomu
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.03a
    • /
    • pp.622-627
    • /
    • 2008
  • Experiment of active noise control on supersonic jet noise was conducted by use of microjet injection. The microjets were injected to the shear layer of the main jet through 22 small holes at the lip of a rectangular nozzle. Based on the measurement of farfield sound pressure, it was found that the jet noise was effectively reduced by several dB(in some cases up to 10 dB). The power levels of all measurement points were also reduced by use of microjet injection. The microjet affected not only the broadband noise but also the screech tone noise. The sound pressure level, the frequency of the screech tone, and the structure of the jet could be changed by the microjet. Flow visualization with schlieren technique was also made to observe the effect of microjet on the flow field.

  • PDF

The Active Noise Control in Harmonic Enclosed Sound Fields (I) Computer Simulation (조화가진된 밀폐계 음장에서의 능동소음제어 (I) 컴퓨터 시물레이션)

  • Oh, Jae-Eung;Lee, Tae-Yeon;Kim, Heung-Seob;Shin, Joon
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.5
    • /
    • pp.1054-1065
    • /
    • 1993
  • A computer simulation is performed on the effectiveness of the active minimization of harmonically excited enclosed sound fields for producing global reduction in the amplitude of the pressure fluctuations. In this study for the appreciable reductions in total time averaged acoustic potential energy, $E_{pp}$, the transducer location strategies for three dimensional active noise control is presented based on a state space modal which approximates the closed acoustic field.In this study, the above theoretical basis is used to investigate the application of active control to sound fields of low modal density. By the used of room-like 3-dimensional rectangular enclosure it is demonstrated that the reductions in $E_{pp}$ can be achieved by using a single secondary source, provided that the source is placed within the half a wavelength from the primary source and placed away from nodal line of the sound field. Concerning the reductions in $E_{pp}$ by minimzing the pressure in sound fields by the use of 3-dimensional rectangular enclosure, the effects of the number of sensors and the locations of these sensors are investigated. When a few modes dominate the response it is found that if only a limited number of sensors are located away from nodal line and located at the pressure maxima of the sound field such as at each corner of a rectangular enclosure.