• Title/Summary/Keyword: active grid

Search Result 451, Processing Time 0.027 seconds

Adaptive DC-link Voltage Control for Shunt Active Power Filter

  • Wang, Yu;Xie, Yun-Xiang
    • Journal of Power Electronics
    • /
    • v.14 no.4
    • /
    • pp.764-777
    • /
    • 2014
  • This study analyzes the mathematical relationship between DC-link voltage and system parameters for shunt active power filters (APFs). Analysis and mathematical deduction are used to determine the required minimum DC-link voltage for APF. A novel adaptive DC-link voltage controller for the three-phase four-wire shunt APF is then proposed. In this controller, the DC-link voltage reference value will be maintained at the required minimum voltage level. Therefore, power consumption and switching loss will effectively decrease. The DC-link voltage can also adaptively yield different DC-link voltage levels based on different harmonic currents and grid voltage levels and thus avoid the effects of harmonic current and grid voltage fluctuation on compensation performance. Finally, representative simulation and experimental results in a three-phase four-wire center-split shunt APF are presented to verify the validity and effectiveness of the minimum DC-link voltage design and the proposed adaptive DC-link voltage controller.

Design of Three-port Flyback Inverter for Active Power Decoupling (능동 전력 디커플링을 위한 3권선 방식의 플라이백 인버터 설계)

  • Kim, Kyu-Dong;Kim, Jun-Gu;Lee, Tae-Won;Jung, Yong-Chae;Won, Chung-Yuen
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.486-487
    • /
    • 2012
  • In this paper, novel three-port active power decoupling (APD) method for applying 250[W] micro-inverter. This type using third port for active power decoupling stores the surplus energy and supplies sufficient energy to grid. Conventional decoupling circuit is applied in single phase grid connected micro-inverter especially single-stage configuration like flyback-type DC-AC inverter. In this passive power decoupling method, electrolytic capacitor with large capacitance is needed for decoupling from constant DC power and instantaneous AC power. However the decoupling capacitor is replaced with film capacitor by using APD, thus the overall system can achieve smaller size and long lifespan. Proposed three-port flyback inverter is verified by design and simulation.

  • PDF

Research and Stability Analysis of Active-Disturbance-Rejection-Control-Based Microgrid Controllers

  • Xu, Xiaoning;Zhou, Xuesong;Ma, Youjie;Liu, Yiqi
    • Journal of Power Electronics
    • /
    • v.17 no.6
    • /
    • pp.1611-1624
    • /
    • 2017
  • With the rapid development of microgrid technology, microgrid projects are no longer limited to laboratory demonstrations and pilot platforms. It shows greater value in practical applications. Hence, the smooth interaction between a microgrid and the main grid plays a critical role. In this paper, a control method based on active disturbance rejection control (ADRC) is proposed in order to realize seamless transitions between grid-connected and islanding operation modes and stable operation with variable loads. It is verified by simulations that the proposed ADRC-based method features better performance when compared to conventional proportional-integral-differential (PID) control. Meanwhile, the stability of the third-order extended state observer (ESO) in second-order ADRC is validated by using Lyapunov stability criteria.

Droop Control Scheme of a Three-phase Inverter for Grid Voltage Unbalance Compensation

  • Liu, Hongpeng;Zhou, Jiajie;Wang, Wei;Xu, Dianguo
    • Journal of Power Electronics
    • /
    • v.18 no.4
    • /
    • pp.1245-1254
    • /
    • 2018
  • The stability of a grid-connected system (GCS) has become a critical issue with the increasing utilization of renewable energy sources. Under grid faults, however, a grid-connected inverter cannot work efficiently by using only the traditional droop control. In addition, the unbalance factor of voltage/current at the common coupling point (PCC) may increase significantly. To ensure the stable operation of a GCS under grid faults, the capability to compensate for grid imbalance should be integrated. To solve the aforementioned problem, an improved voltage-type grid-connected control strategy is proposed in this study. A negative sequence conductance compensation loop based on a positive sequence power droop control is added to maintain PCC voltage balance and reduce grid current imbalance, thereby meeting PCC power quality requirements. Moreover, a stable analysis is presented based on the small signal model. Simulation and experimental results verify the aforementioned expectations, and consequently, the effectiveness of the proposed control scheme.

Power Control Strategies for Single-Phase Voltage-Controlled Inverters with an Enhanced PLL

  • Gao, Jiayuan;Zhao, Jinbin;He, Chaojie;Zhang, Shuaitao;Li, Fen
    • Journal of Power Electronics
    • /
    • v.18 no.1
    • /
    • pp.212-224
    • /
    • 2018
  • For maintaining a reliable and secure power system, this paper describes the design and implement of a single-phase grid-connected inverter with an enhanced phase-locked loop (PLL) and excellent power control performance. For designing the enhanced PLL and power regulator, a full-bridge voltage-controlled inverter (VCI) is investigated. When the grid frequency deviates from its reference values, the output frequency of the VCI is unstable with an oscillation of 2 doubling harmonics. The reason for this oscillation is analyzed mathematically. This oscillation leads to an injection of harmonics into the grid and even causes an output active power oscillation of the VCI. For eliminating the oscillation caused by a PLL, an oscillation compensation method is proposed. With the proposed method, the VCI maintains the original PLL control characteristics and improves the PLL robustness under grid frequency deviations. On the basis of the above analysis, a power regulator with the primary frequency and voltage modulation characteristics is analyzed and designed. Meanwhile, a small-signal model of the power loops is established to determine the control parameters. The VCI can accurately output target power and has primary frequency and voltage modulation characteristics that can provide active and reactive power compensation to the grid. Finally, simulation and experimental results are given to verify the idea.

A Fast and Robust Grid Synchronization Algorithm of a Three-phase Converters under Unbalanced and Distorted Utility Voltages

  • Kim, Kwang-Seob;Hyun, Dong-Seok;Kim, Rae-Yong
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.3
    • /
    • pp.1101-1107
    • /
    • 2017
  • In this paper, a robust and fast grid synchronization method of a three-phase power converter is proposed. The amplitude and phase information of grid voltages are essential for power converters to be properly connected into the utility. The phase-lock-loop in synchronous reference frame has been widely adopted for the three-phase converter system since it shows a satisfactory performance under balanced grid voltages. However, power converters often operate under abnormal grid conditions, i.e. unbalanced by grid faults and frequency variations, and thus a proper active and reactive power control cannot be guaranteed. The proposed method adopts a second order generalized integrator in synchronous reference frame to detect positive sequence components under unbalanced grid voltages. The proposed method has a fast and robust performance due to its higher gain and frequency adaptive capability. Simulation and experimental results show the verification of the proposed synchronization algorithm and the effectiveness to detect positive sequence voltage.

A Study on Active and Reactive Power Control for Efficient Operations of Wind Farm (유.무효 전력 제어를 통한 풍력발전단지의 효율적인 운전)

  • Jang, Sung-Il;Kim, Ji-Won;Kim, Kwang-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.1351-1354
    • /
    • 2002
  • Wind farm which are composed with wind turbine generators can be a good alternatives to solve environmental problem and solutions to cope with energy crisis for using wind energy. Until now, these wind turbine generators have been being studied on the viewpoint of only active power control for reducing the burden of main grid. In this control scheme, we might demand a reactive power compensator in order to make reparation for the reactive power produced from wind turbine generator itself. Therefore, if the reactive power as well as active power of wind turbine generator were controlled according to the demand of reactive power, the installation of a additional reactive power compensator could be reduced. This paper presents the control method of a active and reactive power for wind turbine generators by means of SVPWM(Space Vector Pulse Width Modulation) inverting method and describes a operational coordination of wind turbine generators. The proposed power control algorithm can simply produce the output power of wind turbine generator needed in wind farm, which can reduce the power of main grid more and exclude a supplementary reactive power compensator. We assumed that wind farm are composed with two kinds of wind turbine generators, AC/DC/AC and induction generator types.

  • PDF

Proposal of the Grid-connected Single Phase PCS including the Function of Active Filter (엑티브 필터 기능을 갖는 계통연계형 단상 태양광 발전시스템의 제안)

  • Jang, Seong-Jae;Seo, Hyo-Ryong;Kim, Gyeong-Hun;Park, Sang-Soo;Park, Minwon;Yu, In-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1077-1078
    • /
    • 2008
  • The growing number of nonlinear loads such as static power converters has posed a problem on the quality of electric power supply. The active filters (AF) have been rapidly expanding with the advancement of power electronics technology. The purpose of the active filters is to compensate current harmonics and/or current imbalance. The authors have studied and introduced the PV-AF system; the PV power system, which is used widely as a dispersed source, including the function of active filter to compensate the harmonics caused by nonlinear loads. The PV-AF system has merits not only to compensate harmonics caused by nonlinear loads but also to increase the utilization of PCS. This paper describes the grid-connected single phase PV-AF system and the PSCAD/EMTDC simulation results.

  • PDF

A New Islanding Detection Method Based on Feature Recognition Technology

  • Zheng, Xinxin;Xiao, Lan;Qin, Wenwen;Zhang, Qing
    • Journal of Power Electronics
    • /
    • v.16 no.2
    • /
    • pp.760-768
    • /
    • 2016
  • Three-phase grid-connected inverters are widely applied in the fields of new energy power generation, electric vehicles and so on. Islanding detection is necessary to ensure the stability and safety of such systems. In this paper, feature recognition technology is applied and a novel islanding detection method is proposed. It can identify the features of inverter systems. The theoretical values of these features are defined as codebooks. The difference between the actual value of a feature and the codebook is defined as the quantizing distortion. When islanding happens, the sum of the quantizing distortions exceeds the threshold value. Thus, islanding can be detected. The non-detection zone can be avoided by choosing reasonable features. To accelerate the speed of detection and to avoid miscalculation, an active islanding detection method based on feature recognition technology is given. Compared to the active frequency or phase drift methods, the proposed active method can reduce the distortion of grid-current when the inverter works normally. The principles of the islanding detection method based on the feature recognition technology and the improved active method are both analyzed in detail. An 18 kVA DSP-based three-phase inverter with the SVPWM control strategy has been established and tested. Simulation and experimental results verify the theoretical analysis.