• 제목/요약/키워드: active flap

검색결과 75건 처리시간 0.027초

제 2족지 근위지관절 유리피판술을 이용한 수지 근위지관절 재건 후 시행한 건박리술 (Tenolysis after the reconstruction of PIP joint of the finger using second toe PIP joint free flap)

  • 박형준;이동철;김진수;기세휘;노시영;양재원
    • Archives of Plastic Surgery
    • /
    • 제36권4호
    • /
    • pp.450-457
    • /
    • 2009
  • Purpose: The second toe PIP joint free flap is a method of reconstruction used for abnormalities of the PIP joint of the finger. We report the results of the additional tenolysis in patients with a difference between passive ROM and active ROM after second toe PIP joint free flap. Methods: From March 2001 to July 2008, tenolysis was performed in patients with a difference in their active and passive ROM after second toe PIP joint free transfer, performed on 14 fingers. We performed a retrospective analysis of the medical records, noting the clinical and radiological findings. In addition, we measured the preoperative and postoperative range of motion of the PIP joint. Results: The average active ROM was $22.5^{\circ}$ at the three months after the joint transfer surgery, and was $38^{\circ}$ after additional tenolysis between five months and twelve months after the joint transfer. Conclusions: Additional tenolysis, after the second toe PIP joint free flap, might be a good option for improved results in patients with difference in active and passive ROM of a transferred PIP joint.

SNUF뒷전 플랩 블레이드 메커니즘의 설계 개선 (Enhancement of SNUF Active Trailing-edge Flap Blade Mechanism Design)

  • ;은원종;신상준
    • 한국소음진동공학회논문집
    • /
    • 제23권7호
    • /
    • pp.645-653
    • /
    • 2013
  • SNUF(Seoul National University flap) 블레이드는 고주파 영역에서 진동 감쇠를 위하여, 압전작동기에 의해 움직이는 뒷전 플랩이 장착되어 있는 축소형 로터 블레이드이다. 이 블레이드를 설계하기 위하여 2차원 단면 해석과 1차원 기하학적 정밀 보 해석이 수행되었고, 사용할 재료의 특성을 확인하였다. 이전 연구자들의 실험을 참조하여, ${\pm}4^{\circ}$의 플랩 변위각을 진동감쇠를 위한 설계요건으로 선정하였다. 플랩의 연결 메커니즘을 설계하고, 설계된 메커니즘의 성능을 확인하기 위하여 정적 벤치 시험을 수행하였다. 개선된 버전의 플랩 장치를 설계하고 시험하였으며, 압전작동기로는 APA 200M을 선정하였다. 장비의 개선을 통하여, 최대 플랩변위가 ${\pm}3.7^{\circ}$에 도달하였다. 성능을 평가하기 위하여 고주파 실험을 수행하였으며, 플랩 장치의 전달 함수를 실험적으로 결정하였다. 정적 시험을 완료하여, 훨타워 시험을 위하여 필요한 로터의 요구마력을 계산하였고, 그 이외의 준비가 진행 중에 있다.

Aeroelastic-aerodynamic analysis and bio-inspired flow sensor design for boundary layer velocity profiles of wind turbine blades with active external flaps

  • Sun, Xiao;Tao, Junliang;Li, Jiale;Dai, Qingli;Yu, Xiong
    • Smart Structures and Systems
    • /
    • 제20권3호
    • /
    • pp.311-328
    • /
    • 2017
  • The characteristics of boundary layers have significant effects on the aerodynamic forces and vibration of the wind turbine blade. The incorporation of active trailing edge flaps (ATEF) into wind turbine blades has been proven as an effective control approach for alleviation of load and vibration. This paper is aimed at investigating the effects of external trailing edge flaps on the flow pattern and velocity distribution within a boundary layer of a NREL 5MW reference wind turbine, as well as designing a new type of velocity sensors for future validation measurements. An aeroelastic-aerodynamic simulation with FAST-AeroDyn code was conducted on the entire wind turbine structure and the modifications were made on turbine blade sections with ATEF. The results of aeroelastic-aerodynamic simulations were combined with the results of two-dimensional computational fluid dynamic simulations. From these, the velocity profile of the boundary layer as well as the thickness variation with time under the influence of a simplified load case was calculated for four different blade-flap combinations (without flap, with $-5^{\circ}$, $0^{\circ}$, and $+5^{\circ}$ flap). In conjunction with the computational modeling of the characteristics of boundary layers, a bio-inspired hair flow sensor was designed for sensing the boundary flow field surrounding the turbine blades, which ultimately aims to provide real time data to design the control scheme of the flap structure. The sensor element design and performance were analyzed using both theoretical model and finite element method. A prototype sensor element with desired bio-mimicry responses was fabricated and validated, which will be further refined for integration with the turbine blade structures.

Active load control for wind turbine blades using trailing edge flap

  • Lee, Jong-Won;Kim, Joong-Kwan;Han, Jae-Hung;Shin, Hyung-Kee
    • Wind and Structures
    • /
    • 제16권3호
    • /
    • pp.263-278
    • /
    • 2013
  • The fatigue load of a turbine blade has become more important because the size of commercial wind turbines has increased dramatically in the past 30 years. The reduction of the fatigue load can result in an increase in operational efficiency. This paper numerically investigates the load reduction of large wind turbine blades using active aerodynamic load control devices, namely trailing edge flaps. The PD and LQG controllers are used to determine the trailing edge flap angle; the difference between the root bending moment and its mean value during turbulent wind conditions is used as the error signal of the controllers. By numerically analyzing the effect of the trailing edge flaps on the wind turbines, a reduction of 30-50% in the standard deviation of the root bending moment was achieved. This result implies a reduction in the fatigue damage on the wind turbines, which allows the turbine blade lengths to be increased without exceeding the designed fatigue damage limit.

플랩이 있는 날개의 공탄성 응답 능동제어 (Active Aeroelastic Response Control of 3-D Airfoil System with Flap)

  • 정찬훈;나성수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 춘계학술대회논문집
    • /
    • pp.926-931
    • /
    • 2003
  • 본 연구는 비압축성 유동에 노출되어 있는 2-D wing-flap 시스템의 공탄성 응답의 능동제어를 다루고 있다. 본 연구 논문의 목표는 LQG 제어법칙을 수행함으로써 임계 비행속도하에서 플러터의 비안정성을 억제하고 돌풍이나 blast load에 의한 임계 공탄성 응답의 성능을 향상시키는 것과 동적응답을 감쇠하는 수행능력들을 증명하는데 있다.

  • PDF

수부기능의 재건을 위한 기능성 유리 박근 근피판 이식 (Functioning Gracilis Musculocutaneous Free Flap Transplantation for the Reconstruction of Hand Function)

  • 이광석;한승범;황인철;서동원
    • Archives of Reconstructive Microsurgery
    • /
    • 제9권2호
    • /
    • pp.103-109
    • /
    • 2000
  • Purpose : We performed this study in order to analyze the clinical results of functioning gracilis musculocutaneous free flap transplantation for reconstructon of hand function in cases of Volkmann's ischemic contracture and massive soft tissue injury of forearm. Materials and methods : 18 cases were reviewed with 5 yeas of mean follow up period. We evaluated total active motion of the finger joints and wrist, pinch and grip strength. Results : The flap were survived in 17 cases and 1 case was failed due to infection. The sum of active motion of finger joints(TAM) was improved from 0 to $173.8^{\circ}$. The average grip and pinch strength was improved from 0 kg to $2.7{\pm}2.1kg$ and from 0 kg to $2.4{\pm}1.6kg$. Conclusion : The results in most cases were acceptable in relatively long term follow-up. It may be an option for reconstruction of hand function in cases of Volkmann's ischemic contracture and traumatic upper extremity injury.

  • PDF

무지 첨부 절단 환자 재건에서 Moberg Flap과 2족지 수질부 유리피판술의 비교 (Comparison between Moberg Flap and Second Toe Pulp Free Flap for Coverage of Tip Amputation of Thumb)

  • 정강재;기세휘;김진수;이동철;노시영;양재원
    • Archives of Plastic Surgery
    • /
    • 제35권5호
    • /
    • pp.527-532
    • /
    • 2008
  • Purpose: Transverse type or volar oblique type of defect of thumb tip can be covered by Moberg flap or second toe pulp free flap. We compared these two methods in functional result, patients' satisfaction, and sensation, etc. to find a better way to cover the defect of the thumb tip. Methods: From 2003 to 2006, we chose the patients randomly with preoperative pictures. The patients had the defect of the thumb tip which is either transverse or volar oblique type. The 6 patients were treated with Moberg flap and other 6 patients were treated with second toe pulp free flap. We have analyzed the results by 2 point discrimination, side pinching power test, pulp to pulp pinching power test, pain scales (visual analogue scale), satisfaction scales of the patients (functional and aesthetic), the degree of the range of motion, etc. Results: All flaps survived without any complications. In the cases of Moberg flaps, the value of static 2 point discrimination test was 5.6 mm, and the value of moving 2 point discrimination test was 4.8 mm. In the cases of second toe pulp free flaps, the values were 9.6 mm and 9.3 mm. In the cases of Moberg flaps, the value of the Side pinch power test was 6.6 kg, 4.4 kg. In the case of second toe pulp free flaps, the values were 4.8 kg and 2.5 kg. The value of aesthetic satisfaction scale of the patients in Moberg flaps was 5.6, the value of functional satisfaction scale of the patients was 3.6. In cases of second toe pulp free flaps, the values were 5.6 and 3.6. The active range of motion of Interphalangeal joint in the cases of Moberg flaps was 46.6 degree, and the active range of motion of metacarpophalangeal joint was 55 degree, in the cases of second toe pulp free flaps, the values were 36.6 degree and 59 degree. Conclusion: As a result, when the defect of the thumb tip is transverse or volar oblique type, we suggest that the operators choose Moberg flap to cover the defect of the thumb tip.

전이형 외측 상완 피판술을 이용한 주관절 연부조직 결손의 피복 (Transposition Lateral Arm Flap for Coverage of the Elbow Defects)

  • 송주현;이윤민;이주엽
    • Archives of Reconstructive Microsurgery
    • /
    • 제17권2호
    • /
    • pp.82-86
    • /
    • 2008
  • Purpose: Soft tissue defect can occur on the posterior aspect of the elbow after trauma or fracture fixation. To cover the defect and maintain elbow functions, various flap surgeries including latissimus dorsi muscle flap, lateral arm flap and radial forearm flap can be performed. We present the clinical results of transposition lateral arm flap for coverage of the elbow defect and discuss the cause of posterior soft tissue necrosis after fracture fixation. Materials and Methods: Two patients who had posterior soft tissue defect of the elbow after open reduction of the fractures around the elbow were treated with transposition lateral arm flap. The mean size of skin defect was 20 $cm^2$. The flap was elevated with posterior radial collateral artery pedicle and transposed to the defect area. Donor defect was covered with split thickness skin graft. The elbow was immobilized for 1 week in extended position and active range of motion was permitted. Results: All two cases of transposition lateral arm flap survived without marginal necrosis. The average range of motion of the elbow was 10~115 degrees. Mayo elbow performance score was 72 and Korean DASH score was 23. Conclusion: When elbow fractures are fixed with three simultaneous plates and screws, skin necrosis can occur on the posterior aspect of the elbow around olecranon area. If the size of skin defect is relatively small, transposition lateral arm flap is very useful option for orthopaedic surgeons without microsurgical technique.

  • PDF

Review of Active Rotor Control Research in Canada

  • Feszty, Daniel;Nitzsche, Fred
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제12권2호
    • /
    • pp.93-114
    • /
    • 2011
  • The current status of Canadian research on rotor-based actively controlled technologies for helicopters is reviewed in this paper. First, worldwide research in this field is overviewed to put Canadian research into context. Then, the unique hybrid control concept of Carleton University is described, along with its key element, the "stiffness control" concept. Next, the smart hybrid active rotor control system (SHARCS) projected's history and organization is presented, which aims to demonstrate the hybrid control concept in a wind tunnel test campaign. To support the activities of SHARCS, unique computational tools, novel experimental facilities and new know-how had to be developed in Canada, among them the state-of-the-art Carleton Whirl Tower facility or the ability to design and manufacture aeroelastically scaled helicopter rotors for wind tunnel testing. In the second half of the paper, details are provided on the current status of development on the three subsystems of SHARCS, i.e. that of the actively controlled tip, the actively controlled flap and the unique stiffness-control device, the active pitch link.

지연처치후 동맥화된 족배 정맥 건피판을 이용한 수부의 재건 (Dorsalis Pedis Tendocutaneous Delayed Arterialized Venous Flap in Hand Reconstruction)

  • 조병채;이동훈
    • Archives of Reconstructive Microsurgery
    • /
    • 제8권1호
    • /
    • pp.56-63
    • /
    • 1999
  • 저자들은 1994년부터 1997년까지 수부에 급성 연부조직 손실과 신근건 결손을 가진 2명의 환자에 대해 지연처치후 동맥화된 족배 정맥 건피판술을 시행하였다. 피판의 생존 표면적은 2명 모두 100%였다. 피판 크기는 각각 $10{\times}10cm,\;6{\times}6cm$였다. 술후 2주째 능동적 굴곡운동과 수동적 신전 운동을 시작하였고 점진적인 저항운동을 5주간 실시하였다. 피판은 수부의 정상 피부와 비슷한 색깔과 피부상태를 보였다. 지연처치후 동맥화된 정맥 건피판은 순수 정맥피판이나 동맥화된 정맥피판보다 큰 피판을 만들 수 있으며 동맥화후 정맥피판의 생존율을 높여 복합 피판이 가능하게 하며 공여부의 주 동맥을 보존할 수 있고 얇은 조직을 얻을 수 있으며 피판을 심부 박리 없이 쉽게 거상할 수 있는 장점을 가진다. 단점으로는 두 단계의 수술이 필요하고 공여부 반흔과 족지의 신전이 약해질 수 있다.

  • PDF