• Title/Summary/Keyword: activated sludge system

Search Result 237, Processing Time 0.026 seconds

Application of MBBR Process in the Activated Sludge Process (기존 활성슬러지 공정의 MBBR 공정 적용가능성 평가)

  • Park, Woon-Ji;Lee, Hae-Seung;Lee, Chan-Ki;Kim, Sung-Gun
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.5
    • /
    • pp.457-465
    • /
    • 2004
  • The objective of this study is to evaluate the possibility to apply the Moving Bed Biofilm Reactor(MBBR) in the activated sludge treatment process with existing aerobic HRT. Optimal operation conditions were assumed according to the analysis of organic matter and nutrients removal efficiencies depending on loading variations. The process was operated under different conditions: RUN I(HRT=7.14hr, $I{\cdot}R=100%$), RUN II(HRT=6.22hr, $I{\cdot}R=100%$), RUN III(HRT=6.22 hr, $I{\cdot}R=150%$), RUN IV(HRT=6.22hr, $I{\cdot}R=200%$), the TBOD removal efficien cies are 88%, 88.5%, 94.6%, 97.6%, respectively. Overall TSS removal efficiency is 90%, and it is increasing in RUN IV. In the case of Nitrogen, the highest removal efficiency of 90% was observed in RUN III and RUN IV, Nitrification and Denitrification rates are 0.013-0.016kg $NH_3-N/kg$ Mv-d and 0.009-0.019kg $NO_3/kg$ Mv-d, respectively. Phosphorus removal efficiencies are 89.6% in RUN I, 91.5% in RUN II, 84.3% in RUN III, and 76.4% in RUN IV. The process under shorter SRT yields better performance in terms of phosphorus removal. It was noticed that to achieve the effluent phosphorus concentration ofless than 1mg/L and removal efficiency higher than 80%, SRT should not be longer than 10 days. Experimental result shows that HRT of 6.22 hours is suitable for this treatment process, and, as a result, the aerobic reactor including moving media and DO depletion tank have a sufficient effect to the process performance.

Metabolic Responses of Activated Sludge to Pentachlorophenol in SBR Systems

  • ;Larry D. Benefield
    • Journal of Environmental Science International
    • /
    • v.3 no.3
    • /
    • pp.273-284
    • /
    • 1994
  • The primary objective of this study was to examine the toxic effects of PCP on activated sludge and to analyze its metabolic responses while treating wastewater containing pentachlorophenol (PCP) in a sequencing batch reactor (SBR) system operating under different control strategies. This study was conducted in two phases 1 and 2 (8-hr and 12-hr cycles). Each phase was operated with two control strategies I and II. Strategy I (reactor 1) involved rapid addition (5 minutes to complete) of substrate to the reactor with continuous mixing but no aeration for 2 hours. Strategy ll (reactor 2) involved adding the feed continuously during the first 2 hours of the cycle when the system was mixed but not aerated. During both phases each reactor was operated at a sludge age of 15 days. The synthetic wastewater was used as a feed. The COD of the feed solution was about 380 mg/l. After the reference response for both reactors was established, the steady state response of each system was established for PCP feed concentrations of 0.1 mg/l, 1.0 mg/l, and 5.0 mg/l in SBR systems operating on both 8-hr and 12-hr cycles. Soluble COD removal was not inhibited at any feed PCP concentrations used. At 5.0 mg/l fined PCP concentration and in SBR systems operating on phase 2, the concentrations of MLVSS were decreased; selective pressure on the mixed biomass might be increased, narrowing the range of possible ecological responses; the settleability of activated sludge was poor; the SOURS were increased, showing that the systems were shocked. Nitrification was made to some extent at all concentrations of feed PCP in SBR systems operating on phase 2 whereas in SBR systems operating on phase 1 little nitrification was observed. Then, nitrification will be delayed as much as soluble COD removal is retarded due to PCP inhibition effects. Enhanced biological phosphorus removal occurring in the system operating with control strategy I during phase 1 of this work and in the presence of low concentrations of PCP was unreliable and might cease at anytime, whereas enhanced biological phosphorus removal occurring in the system operating with either control strategy I or II during phase 2 of this work and in the Presence of feed PCP concentrations up to 1.0 mg/l was reliable. When, however, such processes were exposed to 5.0 mg/l PCP dose, enhanced phosphorus removal ceased and never returned.

  • PDF

The Optimal Model of Fuzzy-Neural Network Structure using Genetic Algorithm and Its Application to Nonlinear Process System (유전자 알고리즘을 사용한 퍼지-뉴럴네트워크 구조의 최적모델과 비선형공정시스템으로의 응용)

  • 최재호;오성권;안태천;황형수
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 1996.10a
    • /
    • pp.302-305
    • /
    • 1996
  • In this paper, an optimal identification method using fuzzy-neural networks is proposed for modeling of nonlinear complex systems. The proposed fuzzy-neural modeling implements system structure and parameter identification using the intelligent schemes together with optimization theory, linguistic fuzzy implication rules, and neural networks(NNs) from input and output data of processes. Inference type for this fuzzy-neural modeling is presented as simplified inference. To obtain optimal model, the learning rates and momentum coefficients of fuzz-neural networks(FNNs) and parameters of membership function are tuned using genetic algorithm(GAs). For the purpose of its application to nonlinear processes, data for route choice of traffic problems and those for activated sludge process of sewage treatment system are used for the purpose of evaluating the performance of the proposed fuzzy-neural network modeling. The show that the proposed method can produce the intelligence model w th higher accuracy than other works achieved previously.

  • PDF

Estimation of Dominant Bacterial Species in a Bench-Scale Shipboard Sewage Treatment Plant

  • Mansoor, Sana;Ji, Hyeon-Jo;Shin, Dae-Yeol;Jung, Byung-Gil;Choi, Young-Ik
    • Journal of Environmental Science International
    • /
    • v.28 no.10
    • /
    • pp.899-905
    • /
    • 2019
  • Recently, an innovative method for wastewater treatment and nutrient removal was developed by combining the sequence batch reactor and membrane bioreactor to overcome pollution caused by shipboard sewage. This system is a modified form of the activated sludge process and involves repeated cycles of mixing and aeration. In the present study, the bacterial diversity and dominant microbial community in this wastewater treatment system were studied using the MACROGEN next generation sequencing technique. A high diversity of bacteria was observed in anaerobic and aerobic bioreactors, with approximately 486 species. Microbial diversity and the presence of beneficial species are crucial for an effective biological shipboard wastewater treatment system. The Arcobacter genus was dominant in the anaerobic tank, which mainly contained Arcobacter lanthieri (8.24%), followed by Acinetobacter jahnsonii (5.81%). However, the dominant bacterial species in the aerobic bioreactor were Terrimonas lutea (7.24%) and Rubrivivax gelatinosus (4.95%).

Reuse of the sewage from sea area using the Submerged Moving Media Complete Mixing Activated Sludge (SMMCMAS) (회전매체를 가진 완전혼합활성슬러지 공법을 이용한 온천지구 하수의 재이용)

  • 김홍태;김학석
    • Journal of Environmental Science International
    • /
    • v.11 no.1
    • /
    • pp.69-74
    • /
    • 2002
  • This study was performed to evaluate an applicability of the SMMCMAS system for reuse of the sewage from spa area and was operated to HLR(Hydraulic loading rate) of 211.3 to 126.8 $\ell$/㎥/d. The operating HRT(Hydraulic retention time) ranges were 2.5 to 1.5 hours. Conclusions are as follows; At the optimum HLR of 158.5 $\ell/\m^2$/d (HRT of 2.0 hours), the maximum BOD removal efficiency was 94% and the effluent BOD concentration was 1.1mg/$\ell$ in result. As the HLR was increased to 211.3 $\ell/\m^2$/d, BOD removal efficiency was decreased to 75% and BOD removal efficiency was also reduced to 74% at lower HLR of 126.8 $\ell/\m^2$/d. It shows that the maximum BOD removal efficiency occurs at an optimum HLR value and that the removal efficiency decreases when the HLR is either higher or lower than the optimum value. Sludge production rates were ranged 0.01 to 0.24gVSS/gBODrem/d and accomplished to 0.01gVSS/gBODrem/d at the optimum HLR of 158.5 $\ell/\m^2$/d.

Determination of Microbial Growth by Protein Assay in an Air-Cathode Single Chamber Microbial Fuel Cell

  • Li, Na;Kakarla, Ramesh;Moon, Jung Mi;Min, Booki
    • Journal of Microbiology and Biotechnology
    • /
    • v.25 no.7
    • /
    • pp.1114-1118
    • /
    • 2015
  • Microbial fuel cells (MFCs) have gathered attention as a novel bioenergy technology to simultaneously treat wastewater with less sludge production than the conventional activated sludge system. In two different operations of the MFC and aerobic process, microbial growth was determined by the protein assay method and their biomass yields using real wastewater were compared. The biomass yield on the anode electrode of the MFC was 0.02 g-COD-cell/gCOD-substrate and the anolyte planktonic biomass was 0.14 g-COD-cell/g-COD-substrate. An MFC without anode electrode resulted in the biomass yield of 0.07 ± 0.03 g-COD-cell/g-CODsubstrate, suggesting that oxygen diffusion from the cathode possibly supported the microbial growth. In a comparative test, the biomass yield under aerobic environment was 0.46 ± 0.07 g-COD-cell/g-COD-substrate, which was about 3 times higher than the total biomass value in the MFC operation.

A Study on the Operation Aid Expert System for Activated Sludge Process (활성슬러지 공정에서의 조업지원용 전문가 시스템에 관한 연구)

  • Cho, Wook-Sang;Lee, Jin-Woo;Park, Sang-Jin;Won, Jong-Sik;Kim, Sang-Wook
    • Applied Chemistry for Engineering
    • /
    • v.7 no.2
    • /
    • pp.371-378
    • /
    • 1996
  • A prototype of expert system which can support the operation for the municipal waste water treatment plant located at Kyoung-Ki Do, Kwang-ju Kun was developed and tested. This system provides (i) tracking the cause of the problem, (ii) analysis, and (iii) solution Knowledge-base consists of about 100 production-rules for the biological wastewater process, such as bio-reactor and final clarifier. Rules were obtained from the analysis of the problems such as sludge bulking. The system provides stable process control and management and effectively helps inexperienced operators with advanced and standard technologies. Future works will focus to develop a statistical process control model and associate with expert system. The control model can process the operation data statistically; analyze the relationship between affecting factors and control variables; and provide optimum operation parameters.

  • PDF

Salt Acclimation Behavior of the Nitrifier Consortium for the Nitrification of Saline Wastewater

  • Seo, Jae-Koan;Kim, Sung-Koo
    • 한국생물공학회:학술대회논문집
    • /
    • 2001.11a
    • /
    • pp.590-593
    • /
    • 2001
  • The effect of salinity on the nitrification efficiency of the nitrifier consortium was evaluated for the nitrification of saline wastewater. The nitrifier consortium, which was the activated sludge acclimated with ammonium as the only energy source, was used as the nitrifier for the salt acclimation. Airlift reactors for the nitrification of ammonia with increasing concentration in saline synthetic wastewater (35 g/I NaCD, and synthetic wastewater without salt as a control, were continuously operated with the nitrifier consortium for 43 days. The ammonia removal rate was about 23g ammonia-N/$m^3$/day in both the absence and presence of the salt. An accumulation of nitrite was observed in the saline nitrification reactor at an early period. However, the nitrite decreased to less than 1 mg/l after 39 days of operation. The salinity increased the acclimation time of the nitrifier consortium to obtain a stable marine nitrification system. However, the salt acclimated system showed the efficient removal of ammonia which was same as that without salt.

  • PDF

The Treatment Characteristics of Intermittent Aeration and Conventional Activated Sludge Processes According to the Changes of Temperature and pH (온도 및 pH 변화에 따른 연속 및 간헐 포기식 활성슬러지법의 처리 특성)

  • Lee, Jeoung-Su;Lee, Tae-Kyoo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.6
    • /
    • pp.1001-1009
    • /
    • 2000
  • This study is to find the utilization of intermittent aeration system, around S-COD, T-COD, SS, timewise changes of treatment performance, sludge conversion yield, changes of temperature and pH, etc. In consequence of this study, factors of temperature correction showed 1.052 on continuous aeration, and 1.056 on intermittent aeration which is more sensitive to temperature through a minute degree. Meanwhile, sludge conversion yield on intermittent aeration showed lower and more economical than that on continuous aeration. In case of changing pH, treatment water of both reactors worsened slightly in acid but improved in alkali. In general. considering the quality of effluent water, variation pH of effluent water, etc. the case of intermittent aeration was more favorable than that of continuous aeration.

  • PDF

The Effect of the Attached Growth in Aerobic Reactor on Nitrogen Removal in A2/O processes (포기조에 충진된 고정상 담체가 A2/O공정에서 질소제거에 미치는 영향)

  • Whang, Gye-Dae;Bae, Sung-Hyun
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.6
    • /
    • pp.1022-1030
    • /
    • 2006
  • Activated sludge reactors maintaining an MLSS of 3,000 mg/L and packed Bio Contact Media (BCM fixed beds) was studied in lab-scale to determine the optimal packing ratio and an HRT of aerobic reactor in terms of organic removal, nitrification, denitrification efficiencies. At all HRTs of 3 hr, 5 hr, 7 hr respectively, reactors without BCM, control reactors, had the lowest TCODcr removal efficiency about 74.6%, and reactors with the BCM packing ratios of 10%, 15%, 20% had a greater TCODcr removal efficiency above 81.4%. As HRT decreased, the TCODcr removal efficiency decreased also in all reactors. However, a better utilization of TCODcr even at a higher organic loading was observed in reactors with BCM. The nitrification efficiency at all reactors was greater than 94%, and reactor with 20% packing of BCM had the highest nitrification efficiency at 97.9% while the TKN loading increased at $0.085mgTKN/m^3{\ast}day$ as HRT decreased, In terms of denitrification efficiency, the reactor without BCM ranged from 11.6% to 13.7%, and the reactors with BCM ranged from 28.3% to 63.4% which suggests that the more BCM is packed in the reactors, the higher the denitrification efficiency is achieved. Two parallel $A^2/O$ systems maintaining an MLSS of 3,000 mg/L were operated to investigate the effect of BCM packing ratio of 20% on organic removal, nitrification, denitrification efficiencies. Packing with BCM in system of aerobic reactor affected the SCODcr removal efficiency that increased from 73% to 78%. The nitrification efficiency for both systems with or without BCM was greater than 95%. The denitrification efficiency of systems with BCM and without BCM was 85.8% and 81.8%, respectively which appears that the denitrification efficiency was increased slightly by packing BCM. Compared denitrification efficiency in $A^2/O$ system to previous experimental study with activated sludge reactors operates with the same HRT $A^2/O$ system showed only 29% greater denitrification efficiency. It suggests that $A^2/O$ system with BCM can achieve a similar level of denitrification efficiency when the HRT of anoxic reactor is decreased to some extent.