• Title/Summary/Keyword: acoustic methods

Search Result 918, Processing Time 0.032 seconds

Voice Quality in Patients with Asthma (천식환자에서의 음성의 질)

  • Han, Myung-Woul;Kim, Seong-Tae;Choi, Seung-Ho;Kim, Sang-Yoon;Nam, Soon-Yuhl
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.20 no.1
    • /
    • pp.63-67
    • /
    • 2009
  • Background and Objectives: In patients with asthma, increased obstruction and resistance of airway result in impairment in the generation of voice. Allergy and nasal polyposis, which are frequently observed in patients with asthma, are other factors that affect the vocal performance. Bronchodilators and steroids are commonly used in the treatment of asthma, and these agents also have been reported to be associated with voice changes. The aim of this study is to evaluate the voice quality in patients with mild to-moderate asthma by subjective and objective methods. Materials and Methods: A total of 36 patients with asthma established in the Department of Respiratory Medicine were included in this study. 23 were women and 13 were men, with a mean age of 51.7 years. The average duration of asthma was 77.0 months. All patients had mild-to moderate asthma. Acoustic and aerodynamic analyses were performed and the movements of the vocal cords were examined by videolaryngostroboscopy (VLS). Voice Handicap Index (VHI) and GRABS scales were used for subjective evaluations. Results: 50% of patients suffered from dysphonia and FO was 119.3${\pm}$23.7 Hz in male and 198.2${\pm}$18.4 Hz in female patients. There were no significant differences in average shimmer and NHR between females (4.90${\pm}$2.95% ; 0.1O${\pm}$0.04 dB) and males (4.64${\pm}$2.45% ; 0.20${\pm}$0.15 dB). However, the value of jitter was greater for females (2.60${\pm}$1.92%) than for males (1.21${\pm}$0.84%). The VHI score was above the normal limit in 35%, and VLS findings were shown diverse abnormality in 89% asthmatics from mucosal change to hyperfunction of supragottis and contact granuloma. But duration of illness and steroid dose did not correlate with these findings. Conclusion: Subjective and objective abnormality was shown in more than 50% of asthmatic patients. We suggest that persons who suffer from asthma should be examined for possible voice disorders by laryngologist. Additionally, appropriate medical care and voice therapy should be provided for those who have voice disorders associated with asthma.

  • PDF

The Effect of Triamcinolone Injection on the Vocal cord during Laryngeal Microsurgery in the Patient of the Vocal Polyp (성대용종환자에서 후두미세수술시에 수술부위에 Triamcinolone 국소주입이 음성에 미치는 영향에 대한 연구)

  • Yoo, Jun;Oh, Kyung Ho;Yoon, Hee Chul;Lee, Doh Young;Woo, Jeung soo;Baek, Seung Kuk;Jung, Kwang Yoon;Kwon, Soon Young
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.26 no.2
    • /
    • pp.122-126
    • /
    • 2015
  • Background and Objective : Laryngeal microscopic surgery (LMS) is popular method to treat for vocal polyp. There is not always the improvement of the voice after operation. Many methods have been developed for better outcome of the surgery. The purpose of this study is to investigate the effect of the triamcinolone injection at vocal cord during LMS. Materials and Methods : The medical records of 28 patients, received LMS under diagnosis of vocal polyp, were retrospectively reviewed. The patients were divided into two groups depending on whether triamcinolone injected or not (case group : Triamcinolone-injected group, control group : Triamcinolone-not injected group). The quality of voice was evaluated by GRBAS scale, fundamental frequency (Fo), jitter, shimmer and NHR (Noise to harmonic ratio) at previous operation, 4 weeks after operation, 8 weeks after operation. Each voice analysis factor was compared between case group and control group by Independent t-test. Results : The mean differences of each voice analysis factor. The mean difference of Jitter, Shimmer, NHR in case group were lower than in control group, and mean difference of GRBAS scale in case group were higher than in control group. These differences were not significant (p>0.05). Conclusion : Though there was a tendency of better voice outcome in patients of triamcinolone-injection, it may not be concluded that the triamcinolone injection is helpful for better voice outcome in surgery of vocal polyp due to statistical insignificance.

  • PDF

Influence of SNR difference on the Korean speech intelligibility in classrooms (교실에서 신호대잡음비 변이가 한국어 음성명료도에 미치는 영향)

  • Park, Chan-Jae;Jo, Sung-Min;Haan, Chan-Hoon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.38 no.6
    • /
    • pp.651-660
    • /
    • 2019
  • The present study aims to find out the necessary speech sound level which can satisfy with the speech intelligibility in a noisy classroom environments. For this, auralized materials were made to undertake listening tests with 27 people. Speech intelligibility tests were carried out using both Consonant-Vowel-Consonant (CVC) and Phonetically Balanced Words (PBW) methods. Signal to noise ratio was changed by 5 dB for each test. As a result, it was found that speech intelligibilities are increasing with larger Signal to Noise Ratio (SNR). It was also found that there is a lot of difference of speech intelligibilities by SNR for syllables (CVC) with the Reverberation Time (RT) of 1.5 s. However, any significant difference was not found for words (PBW) in the case with RTs of below 0.8 s. Also, it was revealed through the 2-way analysis of variance (ANOVA) test that SNR is the only attentive factor which can affect the Korean speech intelligibilities for both PBW and CVC methods. Therefore, RTs below 0.8 s could be the acoustic criteria for classroom which can minimize the effects of noise. In the case with RTs larger than 0.8 s, much larger SNR is needed to give sufficient speech intelligibility.

Research trends in seabird and marine fish migration: Focusing on tracking methods and previous studies (바닷새 및 해양어류의 이동 연구 동향: 위치추적 기법과 연구 사례를 중심으로)

  • Jin-Hwan Choi;Seongho Yun;Mi-Jin Hong;Ki-Ho Kang;Who-Seung Lee
    • Korean Journal of Environmental Biology
    • /
    • v.40 no.1
    • /
    • pp.25-53
    • /
    • 2022
  • In this study, trends in research methods and topics of seabird and marine fish migration were examined. Based on the framework of existing animal migration studies, future research directions were proposed in relation to the migration of seabirds and fish. In terms of research methodology, with the development of science and technology, tracking techniques using radio telemetry, acoustic telemetry, RFID (radio-frequency identification), satellite tracking, and geolocators are widely used to study seabird and fish migration. Research is also conducted indirectly through a population survey and the analysis of substances in the body. Research contents are largely classified into extrinsic factors that affect migration(such as environmental variables and interspecific competition), intrinsic factors such as hormones, anthropogenic activities including fishery and offshore wind farm, and the effect of global climate change. In future studies, physiological factors that influence or cause migration and dispersal should be identified concerning intrinsic factors. For the analysis of migration ability, it is necessary to study effects of changes in the magnetic field on the migration ability of seabirds and fish, interspecific differences in spatiotemporal migration ability, and factors that influence the migration success rate. Regarding extrinsic factors, research studies on effects of anthropogenic disturbances such as fishery and offshore wind farm and global climate change on the migration and dispersal patterns of marine animals are needed. Finally, integrated studies on the migration of seabirds and fish directly or indirectly affecting each other in various ecological aspects are required.

A Meshless Method Using the Local Partition of Unity for Modeling of Cohesive Cracks (점성균열 모델을 위한 국부단위분할이 적용된 무요소법)

  • Zi, Goangseup;Jung, Jin-kyu;Kim, Byeong Min
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.5A
    • /
    • pp.861-872
    • /
    • 2006
  • The element free Galerkin method is extended by the local partition of unity method to model the cohesive cracks in two dimensional continuum. The shape function of a particle whose domain of influence is completely cut by a crack is enriched by the step enrichment function. If the domain of influence contains a crack tip inside, it is enriched by a branch enrichment function which does not have the LEFM stress singularity. The discrete equations are obtained directly from the standard Galerkin method since the enrichment is only for the displacement field, which satisfies the local partition of unity. Because only particles whose domains of influence are influenced by a crack are enriched, the system matrix is still sparse so that the increase of the computational cost is minimized. The condition for crack growth in dynamic problems is obtained from the material instability; when the acoustic tensor loses the positive definiteness, a cohesive crack is inserted to the point so as to change the continuum to a discontiuum. The crack speed is naturally obtained from the criterion. It is found that this method is more accurate and converges faster than the classical meshless methods which are based on the visibility concept. In this paper, several well-known static and dynamic problems were solved to verify the method.

Selection of Scale Model Materials for Acoustical Evaluation of 1:50 Multipurpose Halls (1:50 다목적홀의 음향평가를 위한 축소모형재료의 선정)

  • Jeon, Jin-Yong;Kim, Jeong-Jun;Kim, Yong-Hee
    • The Journal of the Acoustical Society of Korea
    • /
    • v.28 no.8
    • /
    • pp.781-789
    • /
    • 2009
  • The absorption coefficients of the materials used in a 1:50 scale model multipurpose hall were measured based on ISO 354 and related laws. The shape and materials for the scale model were evaluated based on reflective surfaces, variable acoustic elements and sound-absorbing quality (125Hz-1kHz average) of seats. The measured average absorption coefficients of audience seats, audience and orchestra were 0.64, 0.74 and 0,45, respectively, which were simulated with the combination of wood, absorption materials and foam board. Various mounting methods for absorption curtain and banner were considered according to the installation methods. The average absorption coefficient was measured as 0.42, 0.47 and 0.45 in the conditions of Type A mounting, E mounting with 0.9 m backing air cavity, and Type G mounting which is suspended at the ceiling, respectively. It was confirmed that the absorption coefficient was increased at low frequency by backing air gap. The finishing material of stage house was an absorption material covered with thin fabric, which aimed average absorption coefficient of 0.68 by using fiber glass board. Each part of the real materials was compared with those of 1:50 scale model and it was found that the absorption characteristics of both cases were similar.

Ceftriaxone Associated Biliary Pseudolithiasis (Ceftriaxone 사용후 발생된 Pseudolithiasis)

  • Kim, Jae-Young;Ko, Jae-Sung;Lee, Hwan-Jong;Ko, Young-Ryul;Seo, Jeong-Kee
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.1 no.1
    • /
    • pp.100-106
    • /
    • 1998
  • Purpose: Ceftriaxone, a potent parenteral third-generation semisynthetic cephalosporin is widely used for the treatment of a variety of bacterial infections in both children and adult. Review of recent data indicates that ceftriaxone treatment has been associated with the development of reversible biliary pseudolithiasis and that is thought by many to be a benign process. Despite, several reports describe patients with ceftriaxone pseudolithiasis who required cholecystectomy for presumed acute cholecystitis. In this study we evaluated the incidence, risk factors, and prognosis of gallbladder pseudolithiasis after ceftriaxone treatment. Methods: Between march, 1997 and January, 1998, any child admitted to the Children's hospital of National University of Seoul and prescribed ceftriaxone for probable or definite bacterial infection were eligible for the study. 21 of them had ultrasound examination on the 2~12 days later after the start of ceftriaxone treatment, 8 of whom documented gallbladder precipitates or pseudolithiasis during treatment by serial abdominal ultrasound. Repeat abdominal ultrasound was performed 10~80 days later after the end of ceftriaxone treatment. The children with underlying liver disease or decreased renal function were excluded in this study. Results: 1) 21 children had ultrasound examinations of gallbladder during ceftriaxone treatment and 8 (38%) of them acquired pseudolithiasis. 2) The patients who developed gallbladder pseudolithiasis were significantly older ($6.3{\pm}2.9$ yr. vs $2.2{\pm}3.1$ yr.)(p<0.05), and older than 24 months were probably the significant risk associated with this phenomenon (p<0.05). However, no significant differences in sex, type of infection, fasting, and ceftriaxone treatment regimen (dose, duration of therapy). 3) The abnormality found on gallbladder ultrasonography was a strikingly hyperechogenic material with post-acoustic shadowing in 5 patients without post-acoustic shadowing in 3 patients 4) Follow up of gallbladder ultrasound was performed in 6 patients after cessation of ceftriaxone treatment. Sonographic abnormalities completely resolved within 14 days post cessation of therapy in 2 patients; 30 days, 1 patient; 80 days, 3 patients. Conclusions: We suggest that routine abdominal ultrasound should be considered in all children who received high dose ceftriaxone in more than 24 months of age and developed hepatobiliary symptoms during or just after ceftriaxone treatment.

  • PDF

THE CURRENT STATUS OF BIOMEDICAL ENGINEERING IN THE USA

  • Webster, John G.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1992 no.05
    • /
    • pp.27-47
    • /
    • 1992
  • Engineers have developed new instruments that aid in diagnosis and therapy Ultrasonic imaging has provided a nondamaging method of imaging internal organs. A complex transducer emits ultrasonic waves at many angles and reconstructs a map of internal anatomy and also velocities of blood in vessels. Fast computed tomography permits reconstruction of the 3-dimensional anatomy and perfusion of the heart at 20-Hz rates. Positron emission tomography uses certain isotopes that produce positrons that react with electrons to simultaneously emit two gamma rays in opposite directions. It locates the region of origin by using a ring of discrete scintillation detectors, each in electronic coincidence with an opposing detector. In magnetic resonance imaging, the patient is placed in a very strong magnetic field. The precessing of the hydrogen atoms is perturbed by an interrogating field to yield two-dimensional images of soft tissue having exceptional clarity. As an alternative to radiology image processing, film archiving, and retrieval, picture archiving and communication systems (PACS) are being implemented. Images from computed radiography, magnetic resonance imaging (MRI), nuclear medicine, and ultrasound are digitized, transmitted, and stored in computers for retrieval at distributed work stations. In electrical impedance tomography, electrodes are placed around the thorax. 50-kHz current is injected between two electrodes and voltages are measured on all other electrodes. A computer processes the data to yield an image of the resistivity of a 2-dimensional slice of the thorax. During fetal monitoring, a corkscrew electrode is screwed into the fetal scalp to measure the fetal electrocardiogram. Correlations with uterine contractions yield information on the status of the fetus during delivery To measure cardiac output by thermodilution, cold saline is injected into the right atrium. A thermistor in the right pulmonary artery yields temperature measurements, from which we can calculate cardiac output. In impedance cardiography, we measure the changes in electrical impedance as the heart ejects blood into the arteries. Motion artifacts are large, so signal averaging is useful during monitoring. An intraarterial blood gas monitoring system permits monitoring in real time. Light is sent down optical fibers inserted into the radial artery, where it is absorbed by dyes, which reemit the light at a different wavelength. The emitted light travels up optical fibers where an external instrument determines O2, CO2, and pH. Therapeutic devices include the electrosurgical unit. A high-frequency electric arc is drawn between the knife and the tissue. The arc cuts and the heat coagulates, thus preventing blood loss. Hyperthermia has demonstrated antitumor effects in patients in whom all conventional modes of therapy have failed. Methods of raising tumor temperature include focused ultrasound, radio-frequency power through needles, or microwaves. When the heart stops pumping, we use the defibrillator to restore normal pumping. A brief, high-current pulse through the heart synchronizes all cardiac fibers to restore normal rhythm. When the cardiac rhythm is too slow, we implant the cardiac pacemaker. An electrode within the heart stimulates the cardiac muscle to contract at the normal rate. When the cardiac valves are narrowed or leak, we implant an artificial valve. Silicone rubber and Teflon are used for biocompatibility. Artificial hearts powered by pneumatic hoses have been implanted in humans. However, the quality of life gradually degrades, and death ensues. When kidney stones develop, lithotripsy is used. A spark creates a pressure wave, which is focused on the stone and fragments it. The pieces pass out normally. When kidneys fail, the blood is cleansed during hemodialysis. Urea passes through a porous membrane to a dialysate bath to lower its concentration in the blood. The blind are able to read by scanning the Optacon with their fingertips. A camera scans letters and converts them to an array of vibrating pins. The deaf are able to hear using a cochlear implant. A microphone detects sound and divides it into frequency bands. 22 electrodes within the cochlea stimulate the acoustic the acoustic nerve to provide sound patterns. For those who have lost muscle function in the limbs, researchers are implanting electrodes to stimulate the muscle. Sensors in the legs and arms feed back signals to a computer that coordinates the stimulators to provide limb motion. For those with high spinal cord injury, a puff and sip switch can control a computer and permit the disabled person operate the computer and communicate with the outside world.

  • PDF

Effect of Acupuncture on Nasal Obstruction in Patients with Persistent Allergic Rhinitis: A Randomized Controlled Trial (지속성 알레르기비염의 비폐색에 대한 침치료의 효과: 무작위배정 대조군 연구)

  • Jo, Jeong-Hyo;Hong, Kweon-Eey;Kang, Wee-Chang;Choi, Sun-Mi;Park, Yang-Chun
    • Journal of Acupuncture Research
    • /
    • v.22 no.6
    • /
    • pp.229-239
    • /
    • 2005
  • Objectives : Allergic rhinitis is a prevalent disease. Nasal obstruction is one of the main symptom in allergic rhinitis. It induces sleep disturbances, depression, attention deficit, memory impairments. Acupuncture treatment for rhinitis was mentioned in literature, but there is not enough report that provide evidence by well designed clinical study. The purpose of this research is to examine the effect of acupuncture treatment for nasal obstruction of allergic rhinitis. Methods : In this randomized, single blind, placebo-controlled study, we compared active acupuncture with minimal acupuncture for the treatment of nasal obstruction owing to persistent allergic rhinitis. Acupoints used in active acupuncture group were I120($Y{\hat{o}}nghyang$), GV23($Sangs{\hat{o}}ng$), IL4(Hapkok). Volunteers who satisfied the requirements were enrolled in study. Total nasal volume(NV) and total nasal minimum cross-sectional area(MCA) were measured by acoustic rhinometry before and after treatments(0min, 7.5min, 15min). Results : 101 subjects finished study. There were not difference between two groups on age, sex, weight, height, blood pressure, pulse, respiratory rate, severity of persistent allergic rhinitis, number of positive antigen. After treatment(0min) total NV were significantly increased compared with before treatment in active acupuncture group(p=0.0007) and minimal acupuncture group(p=0.0175). After treatment(15min) total NV of minimal acupuncture group was decreased compared with before treatment(p=0.2560), but total NV of active acupuncture group was maintained increasing in degree of borderline significance(p=0.0871). After treatment(0min) total NV were significantly increased compared with before treatment in active acupuncture group(0.0007) and minimal acupuncture group(p=0.0175). After treatment(Omin) total MCA were significantly increased compared with before treatment in active acupuncture group(p<0.000l) and minimal acupuncture group(p=0.0005). After treatment(15min) total MCA of minimal acupuncture group was decreased compared with before treatment(p=0.6082), but total NV of active acupuncture group was maintained increasing in degree of borderline significance(p=0.0929). Conclusion : Acupuncture treatment reduced nasal obstruction in persistent allergic rhinitis. Further study in the form of long term is needed.

  • PDF

Estimation of the Freshwater Advection Speed by Improvement of ADCP Post-Processing Method Near the Surface at the Yeongsan Estuary (ADCP 표층유속 자료처리방법 개선을 통한 영산강 하구 표층 방류수 이류속도 산정)

  • Shin, Hyun-Jung;Kang, Kiryong;Lee, Guan-Hong
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.19 no.3
    • /
    • pp.180-190
    • /
    • 2014
  • It has been customary to exclude top 10-20% of velocity profiles in the Acoustic Doppler Current Profiler (ADCP) measurement due to side lobe effects at the boundary. To better understand the mixing in the Yeongsan estuary, the freshwater advection speed (FAS) was recovered from highly contaminated ADCP data near the surface. The velocity profiles were measured by using ADCP at two stations in the Yeongsan estuary during August 2011: one was located in front of the Yeongsan estuarine dam and the other was deployed near Goha Island. The FAS was recovered from the ADCP data set by applying rigorous post-processing methods and compared with the sediment advection speed (SAS). The SAS was determined by the peak time difference of suspended sediment concentration between two stations in the channel, divided by the distance of two stations. The FAS and the SAS showed very similar value when the freshwater discharge was greater than $2.0{\times}10^7$ ton and the SAS was a bit greater when the freshwater discharge was smaller. Since the FAS was on average about 0.8 m/s greater than the velocity at 0.8 of water depth from the bottom, the net discharge, estimated with recovered FAS and integrated over water depth and tidal cycle, was directed seaward during the high discharge contrary to the onshore direction of the net discharge estimated with 0.8 of water depth from the bottom. Moreover, the velocity shear and Richardson number changed when the FAS was used. Thus, the importance of the true FAS is appreciated in the investigation of the surface layer stability. If currents, temperature and salinity were observed for longer time in the future, it could be possible to more accurately understand the formation and decay of stratification as well as the suspended sediment transport processes.