• Title/Summary/Keyword: acoustic information

Search Result 1,215, Processing Time 0.031 seconds

Acoustic images of the submarine fan system of the northern Kumano Basin obtained during the experimental dives of the Deep Sea AUV URASHIMA (심해 자율무인잠수정 우라시마의 잠항시험에서 취득된 북 구마노 분지 해저 선상지 시스템의 음향 영상)

  • Kasaya, Takafumi;Kanamatsu, Toshiya;Sawa, Takao;Kinosita, Masataka;Tukioka, Satoshi;Yamamoto, Fujio
    • Geophysics and Geophysical Exploration
    • /
    • v.14 no.1
    • /
    • pp.80-87
    • /
    • 2011
  • Autonomous underwater vehicles (AUVs) present the important advantage of being able to approach the seafloor more closely than surface vessel surveys can. To collect bathymetric data, bottom material information, and sub-surface images, multibeam echosounder, sidescan sonar (SSS) and subbottom profiler (SBP) equipment mounted on an AUV are powerful tools. The 3000m class AUV URASHIMA was developed by the Japan Agency for Marine-Earth Science and Technology (JAMSTEC). After finishing the engineering development and examination phase of a fuel-cell system used for the vehicle's power supply system, a renovated lithium-ion battery power system was installed in URASHIMA. The AUV was redeployed from its prior engineering tasks to scientific use. Various scientific instruments were loaded on the vehicle, and experimental dives for science-oriented missions conducted from 2006. During the experimental cruise of 2007, high-resolution acoustic images were obtained by SSS and SBP on the URASHIMA around the northern Kumano Basin off Japan's Kii Peninsula. The map of backscatter intensity data revealed many debris objects, and SBP images revealed the subsurface structure around the north-eastern end of our study area. These features suggest a structure related to the formation of the latest submarine fan. However, a strong reflection layer exists below ~20 ms below the seafloor in the south-western area, which we interpret as a denudation feature, now covered with younger surface sediments. We continue to improve the vehicle's performance, and expect that many fruitful results will be obtained using URASHIMA.

THE CURRENT STATUS OF BIOMEDICAL ENGINEERING IN THE USA

  • Webster, John G.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1992 no.05
    • /
    • pp.27-47
    • /
    • 1992
  • Engineers have developed new instruments that aid in diagnosis and therapy Ultrasonic imaging has provided a nondamaging method of imaging internal organs. A complex transducer emits ultrasonic waves at many angles and reconstructs a map of internal anatomy and also velocities of blood in vessels. Fast computed tomography permits reconstruction of the 3-dimensional anatomy and perfusion of the heart at 20-Hz rates. Positron emission tomography uses certain isotopes that produce positrons that react with electrons to simultaneously emit two gamma rays in opposite directions. It locates the region of origin by using a ring of discrete scintillation detectors, each in electronic coincidence with an opposing detector. In magnetic resonance imaging, the patient is placed in a very strong magnetic field. The precessing of the hydrogen atoms is perturbed by an interrogating field to yield two-dimensional images of soft tissue having exceptional clarity. As an alternative to radiology image processing, film archiving, and retrieval, picture archiving and communication systems (PACS) are being implemented. Images from computed radiography, magnetic resonance imaging (MRI), nuclear medicine, and ultrasound are digitized, transmitted, and stored in computers for retrieval at distributed work stations. In electrical impedance tomography, electrodes are placed around the thorax. 50-kHz current is injected between two electrodes and voltages are measured on all other electrodes. A computer processes the data to yield an image of the resistivity of a 2-dimensional slice of the thorax. During fetal monitoring, a corkscrew electrode is screwed into the fetal scalp to measure the fetal electrocardiogram. Correlations with uterine contractions yield information on the status of the fetus during delivery To measure cardiac output by thermodilution, cold saline is injected into the right atrium. A thermistor in the right pulmonary artery yields temperature measurements, from which we can calculate cardiac output. In impedance cardiography, we measure the changes in electrical impedance as the heart ejects blood into the arteries. Motion artifacts are large, so signal averaging is useful during monitoring. An intraarterial blood gas monitoring system permits monitoring in real time. Light is sent down optical fibers inserted into the radial artery, where it is absorbed by dyes, which reemit the light at a different wavelength. The emitted light travels up optical fibers where an external instrument determines O2, CO2, and pH. Therapeutic devices include the electrosurgical unit. A high-frequency electric arc is drawn between the knife and the tissue. The arc cuts and the heat coagulates, thus preventing blood loss. Hyperthermia has demonstrated antitumor effects in patients in whom all conventional modes of therapy have failed. Methods of raising tumor temperature include focused ultrasound, radio-frequency power through needles, or microwaves. When the heart stops pumping, we use the defibrillator to restore normal pumping. A brief, high-current pulse through the heart synchronizes all cardiac fibers to restore normal rhythm. When the cardiac rhythm is too slow, we implant the cardiac pacemaker. An electrode within the heart stimulates the cardiac muscle to contract at the normal rate. When the cardiac valves are narrowed or leak, we implant an artificial valve. Silicone rubber and Teflon are used for biocompatibility. Artificial hearts powered by pneumatic hoses have been implanted in humans. However, the quality of life gradually degrades, and death ensues. When kidney stones develop, lithotripsy is used. A spark creates a pressure wave, which is focused on the stone and fragments it. The pieces pass out normally. When kidneys fail, the blood is cleansed during hemodialysis. Urea passes through a porous membrane to a dialysate bath to lower its concentration in the blood. The blind are able to read by scanning the Optacon with their fingertips. A camera scans letters and converts them to an array of vibrating pins. The deaf are able to hear using a cochlear implant. A microphone detects sound and divides it into frequency bands. 22 electrodes within the cochlea stimulate the acoustic the acoustic nerve to provide sound patterns. For those who have lost muscle function in the limbs, researchers are implanting electrodes to stimulate the muscle. Sensors in the legs and arms feed back signals to a computer that coordinates the stimulators to provide limb motion. For those with high spinal cord injury, a puff and sip switch can control a computer and permit the disabled person operate the computer and communicate with the outside world.

  • PDF

Effect of Acupuncture on Nasal Obstruction in Patients with Persistent Allergic Rhinitis: A Randomized Controlled Trial (지속성 알레르기비염의 비폐색에 대한 침치료의 효과: 무작위배정 대조군 연구)

  • Jo, Jeong-Hyo;Hong, Kweon-Eey;Kang, Wee-Chang;Choi, Sun-Mi;Park, Yang-Chun
    • Journal of Acupuncture Research
    • /
    • v.22 no.6
    • /
    • pp.229-239
    • /
    • 2005
  • Objectives : Allergic rhinitis is a prevalent disease. Nasal obstruction is one of the main symptom in allergic rhinitis. It induces sleep disturbances, depression, attention deficit, memory impairments. Acupuncture treatment for rhinitis was mentioned in literature, but there is not enough report that provide evidence by well designed clinical study. The purpose of this research is to examine the effect of acupuncture treatment for nasal obstruction of allergic rhinitis. Methods : In this randomized, single blind, placebo-controlled study, we compared active acupuncture with minimal acupuncture for the treatment of nasal obstruction owing to persistent allergic rhinitis. Acupoints used in active acupuncture group were I120($Y{\hat{o}}nghyang$), GV23($Sangs{\hat{o}}ng$), IL4(Hapkok). Volunteers who satisfied the requirements were enrolled in study. Total nasal volume(NV) and total nasal minimum cross-sectional area(MCA) were measured by acoustic rhinometry before and after treatments(0min, 7.5min, 15min). Results : 101 subjects finished study. There were not difference between two groups on age, sex, weight, height, blood pressure, pulse, respiratory rate, severity of persistent allergic rhinitis, number of positive antigen. After treatment(0min) total NV were significantly increased compared with before treatment in active acupuncture group(p=0.0007) and minimal acupuncture group(p=0.0175). After treatment(15min) total NV of minimal acupuncture group was decreased compared with before treatment(p=0.2560), but total NV of active acupuncture group was maintained increasing in degree of borderline significance(p=0.0871). After treatment(0min) total NV were significantly increased compared with before treatment in active acupuncture group(0.0007) and minimal acupuncture group(p=0.0175). After treatment(Omin) total MCA were significantly increased compared with before treatment in active acupuncture group(p<0.000l) and minimal acupuncture group(p=0.0005). After treatment(15min) total MCA of minimal acupuncture group was decreased compared with before treatment(p=0.6082), but total NV of active acupuncture group was maintained increasing in degree of borderline significance(p=0.0929). Conclusion : Acupuncture treatment reduced nasal obstruction in persistent allergic rhinitis. Further study in the form of long term is needed.

  • PDF

Considerations of Environmental Factors Affecting the Detection of Underwater Acoustic Signals in the Continental Regions of the East Coast Sea of Korea

  • Na, Young-Nam;Kim, Young-Gyu;Kim, Young-Sun;Park, Joung-Soo;Kim, Eui-Hyung;Chae, Jin-Hyuk
    • The Journal of the Acoustical Society of Korea
    • /
    • v.20 no.2E
    • /
    • pp.30-45
    • /
    • 2001
  • This study considers the environmental factors affecting propagation loss and sonar performance in the continental regions of the East Coast Sea of Korea. Water mass distributions appear to change dramatically in a few weeks. Simple calculation with the case when the NKCW (North Korean Cold Water) develops shows that the difference in propagation loss may reach in the worst up to 10dB over range 5km. Another factor, an eddy, has typical dimensions of 100-200km in diameter and 150-200m in thickness. Employing a typical eddy and assuming frequency to be 100Hz, its effects on propagation loss appear to make lower the normal formation of convergence zones with which sonars are possible to detect long-range targets. The change of convergence zones may result in 10dB difference in received signals in a given depth. Thermal fronts also appear to be critical restrictions to operating sonars in shallow waters. Assuming frequency to be 200Hz, thermal fronts can make 10dB difference in propagation loss between with and without them over range 20km. An observation made in one site in the East Coast Sea of Korea reveals that internal waves may appear in near-inertial period and their spectra may exist in periods 2-17min. A simulation employing simple internal wave packets gives that they break convergence zones on the bottom, causing the performance degradation of FOM as much as 4dB in frequency 1kHz. An acoustic experiment, using fixed source and receiver at the same site, shows that the received signals fluctuate tremendously with time reaching up to 6.5dB in frequencies 1kHz or less. Ambient noises give negative effects directly on sonar performance. Measurements at some sites in the East Coast Sea of Korea suggest that the noise levels greatly fluctuate with time, for example noon and early morning, mainly due to ship traffics. The average difference in a day may reach 10dB in frequency 200Hz. Another experiment using an array of hydrophones gives that the spectrum levels of ambient noises are highly directional, their difference being as large as 10dB with vertical or horizontal angles. This fact strongly implies that we should obtain in-situ information of noise levels to estimate reasonable sonar performance. As one of non-stationary noise sources, an eel may give serious problems to sonar operation on or under the sea bottoms. Observed eel noises in a pier of water depth 14m appear to have duration time of about 0.4 seconds and frequency ranges of 0.2-2.8kHz. The 'song'of an eel increases ambient noise levels to average 2.16dB in the frequencies concerned, being large enough to degrade detection performance of the sonars on or below sediments. An experiment using hydrophones in water and sediment gives that sensitivity drops of 3-4dB are expected for the hydrophones laid in sediment at frequencies of 0.5-1.5kHz. The SNR difference between in water and in sediment, however, shows large fluctuations rather than stable patterns with the source-receiver ranges.

  • PDF

Gas Hydrate Exploration Using LWD/MWD in the Ulleung Basin, the East Sea of Korea (LWD/MWD를 이용한 동해 울릉분지 가스하이드레이트 탐사)

  • Kim, Gil-Young;Yoo, Dong-Geun;Kim, Won-Sik;Lee, Ho-Young;Park, Keun-Pil
    • Geophysics and Geophysical Exploration
    • /
    • v.11 no.3
    • /
    • pp.263-270
    • /
    • 2008
  • The Gas Hydrate Research and Development Organization (KGHDO) of Korea accomplished successfully geophysical logging (LWD: Logging While Drilling, MWD: Measurement While Drilling) for five sites in 2007, in order to investigate the presence of gas hydrate in the Ulleung Basin, the East Sea of Korea. The togging parameters acquired from LWD/MWD dre electrical resistivity, acoustic velocity, neutron density and porosity, and natural gamma. In addition, pressure, temperature, and diameter of borehole were measured. LWD/MWD data showed several evidences indicating the presence of gas hydrate. Based on LWD/MWD data, three coring sites were selected for sampling of gas hydrate. Subsequently, various gas hydrate samples were collected directly from three sites. Therefore. the presence of gas hydrates was verified by coring. LWD/MWD data will be significantly used to estimate the amount of gas hydrate. Also, they will provide important information to elucidate about sedimentologic characteristics of gas-hydrate bearing formation and sedimentary environment of the Ulleung Basin.

Seismic reflection imaging of a Warm Core Ring south of Hokkaido (훗카이도 남부 Warm Core Ring의 탄성파 반사법 영상화)

  • Yamashita, Mikiya;Yokota, Kanako;Fukao, Yoshio;Kodaira, Shuichi;Miura, Seiichi;Katsumata, Katsuro
    • Geophysics and Geophysical Exploration
    • /
    • v.14 no.1
    • /
    • pp.18-24
    • /
    • 2011
  • A multi-channel seismic reflection (MCS) survey was conducted in 2009 to explore the deep crustal structure of the Pacific Plate south of Hokkaido. The survey line happened to traverse a 250-km-wide Warm Core Ring (WCR), a current eddy that had been generated by the Kuroshio Extension. We attempted to use these MCS data to delineate the WCR fine structure. The survey line consists of two profiles: one with a shot interval of 200m and the other with a shot interval of 50 m. Records from the denser shot point line show much higher background noise than the records from the sparser shot point line. We identified the origin of this noise as acoustic reverberations between the sea surface, seafloor and subsurface discontinuities, from previous shots. Results showed that a prestack migration technique could enhance the signal buried in this background noise efficiently, if the sound speed information acquired from concurrent temperature measurements is available. The WCR is acoustically an assemblage of concave reflectors dipping inward, with steeper slopes (${\sim}2^{\circ}$) on th ocean side and gentler slopes (${\sim}1^{\circ}$) on the coastal side. Within the WCR, we recognised a 30-km-wide lens-shaped structure with reflectors on the perimeter.

In-situ Rock Stress Measurement at the Water Tunnel Sites in the OO Oil Storage Facility with Hydraulic Fracturing Method (수압파쇄법을 이용한 OO 원유비축시설 내 수벽 터널에서의 초기응력 측정)

  • Bae, Seong-Ho;Kim, Jae-Min;Kim, Jang-Soon;Lee, Young-Ho
    • Tunnel and Underground Space
    • /
    • v.18 no.1
    • /
    • pp.80-89
    • /
    • 2008
  • The influence of in-situ rock stress on the stability of an underground rock structure increases as the construction depth become deeper and the scale of a rock structure become larger. In general, hydraulic fracturing stress measurement has been performed in the surface boreholes of the target area at the design stage of an underground structure. However, for some areas where the high horizontal stresses were observed or where the overstressed conditions caused by topographical and geological factors are expected, it is desirable to conduct additional in-situ stress measurement in the underground construction site to obtain more detailed stress information for ensuring the stability of a rock structure and the propriety of current design. The study area was a construction site for the additional underground oil storage facility located in the south-east part of OO city, Jeollanam-do. Previous detailed site investigation prior to the design of underground structures revealed that the excessive horizontal stress field with the horizontal stress ratio(K) greater than 3.0 was observed in the construction area. In this study, a total of 13 hydraulic fracturing stress measurements was conducted in two boreholes drill from the two water tunnel sites in the study area. The investigation zone was from 180 m to 300 m in depth from the surface and all of the fracture tracing works were carried out by acoustic televiewer scanning. For some testing intervals at more than 200 m ind depth from surface, the high horizontal stress components the horizontal stress ratio(K) greater than 2.50 were observed. And the overall investigation results showed a good agreement with the previously performed test.

Image Processing Algorithms for DI-method Multi Touch Screen Controllers (DI 방식의 대형 멀티터치스크린을 위한 영상처리 알고리즘 설계)

  • Kang, Min-Gu;Jeong, Yong-Jin
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.48 no.3
    • /
    • pp.1-12
    • /
    • 2011
  • Large-sized multi-touch screen is usually made using infrared rays. That is because it has technical constraints or cost problems to make the screen with the other ways using such as existing resistive overlays, capacitive overlay, or acoustic wave. Using infrared rays to make multi-touch screen is easy, but is likely to have technical limits to be implemented. To make up for these technical problems, two other methods were suggested through Surface project, which is a next generation user-interface concept of Microsoft. One is Frustrated Total Internal Reflection (FTIR) which uses infrared cameras, the other is Diffuse Illumination (DI). FTIR and DI are easy to be implemented in large screens and are not influenced by the number of touch points. Although FTIR method has an advantage in detecting touch-points, it also has lots of disadvantages such as screen size limit, quality of the materials, the module for infrared LED arrays, and high consuming power. On the other hand, DI method has difficulty in detecting touch-points because of it's structural problems but makes it possible to solve the problem of FTIR. In this thesis, we study the algorithms for effectively correcting the distort phenomenon of optical lens, and image processing algorithms in order to solve the touch detecting problem of the original DI method. Moreover, we suggest calibration algorithms for improving the accuracy of multi-touch, and a new tracking technique for accurate movement and gesture of the touch device. To verify our approaches, we implemented a table-based multi touch screen.

Korea Offshore Seismic Data Processing for Gas Detection (천연 가스 탐지를 위한 국내 대륙붕 탄성파자료 처리)

  • Jang, Seong-Hyung;Sunwoo, Don;Yang, Dong-Woo;Suh, Sang-Young;Chung, Bu-Heung
    • Geophysics and Geophysical Exploration
    • /
    • v.4 no.4
    • /
    • pp.115-123
    • /
    • 2001
  • The bright spot is an indicator for natural gas on seismic stack sections, but it is also shown on layers where the acoustic impedance contrast is large. In order to distinguish sharply between gas and impedance contrast we need additional detailed data processing such as velocity analysis, AVO analysis and seismic complex analysis including measures of seismic amplitude, frequency, and phase. In this study, we performed detailed velocity analysis, complex analysis and DHI (Direct Hydrocarbon Indicator) analysis which is the result of amplitude variation according to the incident angles. The seismic complex analysis gives us the geological information which depends on geophysical properties at the interest layer. For the complex analysis, we computed several seismic attributes such as the instantaneous amplitude, the first and the second derivatives of the instantaneous amplitude, the instantaneous phase, the instantaneous frequency and weighted average instantaneous frequency. Then we applied these analysis techniques to a seismic data of Korea offshore which had been logged. From the result of this data analysis, it could be said that high possibility area for gas layer detection has amplitude anomalies in the instantaneous amplitude, the instantaneous frequency and the DHI section resulting from the AVO analysis. If there are not any other anomalies in detailed data processing, it will have low possibility for gas layer detection.

  • PDF

Aerodynamic Study in Normal Korean and Patients with Vocal Polyp (정상인과 성대용종 환자에서의 공기역학적 검사)

  • 서장수;송시연;정유선;김정수;지덕환;이무경
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.10 no.1
    • /
    • pp.5-11
    • /
    • 1999
  • Background and Objectives : Recently, many people suffering from voice change visit otolaryngologist. So, it is important to study vocal function in patients with glottic or laryngeal disease. Aerodynamic investigation is valuable information about the efficiency of the larynx in translating air pressure to acoustic signal. The purpose of this study was to investigate the aerodynamic data in patients with vocal polyp, compare this data with that of the normal Korean. Materials and Methods : In aerodynamic study, maximum phonation time, mean air flow rate, phonatory flow volume and subglottal pressure were tested by using Aerophone II voice function analyzer in 157 normal korean and 143 patients with vocal polyp, aged from 20 to 69 years randomly selected. Results and Conclusion : In vocal polyp, maximum phonation time was significantly decreased and mean air How rate was increased. Phonatory flow volume was significantly decreased and subglottic pressure was increased only in female with vocal polyp. These data will be served as basic data of evaluation after treatment and postoperative assessment of the patients with vocal polyp.

  • PDF