• Title/Summary/Keyword: acoustic evaluation

Search Result 768, Processing Time 0.033 seconds

A Study on the Efficiency Evaluation of Ultrasound Therapy Using Varicose Vein Simulated Tissue Phantom and Tissue Equivalent Phantom (하지정맥류 모사 생체조직 팬텀과 조직등가 팬텀을 이용한 초음파 치료효과 평가에 관한 연구)

  • Kim, Ju-Young;Jung, Tae-Woong;Shin, Kyoung-Won;Noh, Si-Cheol;Choi, Heung-Ho
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.3
    • /
    • pp.427-433
    • /
    • 2018
  • Because of the expectation of the non-invasive treatment effect, Various studies on the treatment of varicose veins using focused ultrasound are reported. In this study, the bio-tissue phantom and tissue equivalent phantom that can be applied to estimation of ultrasonic varicose veins treatment effect. Each phantom was evaluated for its usefulness by evaluating the acoustic characteristics and the shrinkage rate according to the ultrasonic irradiation. A multi-layer structure phantom with three layers of skin, fat, and muscle was constructed considering the structure of the tissue where the varicose veins occurred. The materials constituting each layer were made to have characteristics similar to human body. In addition, the multi-layered phantoms with blood vessel mimic tube, with bovine blood vessel, and with animal tissue were fabricated. The degree of shrinkage of blood vessel mimic material and vascular tissue according to ultrasonic irradiation was evaluated using B-mode image. As the results of this study, it was thought that the proposed phantom could be used effectively in the evaluation of ultrasonic varicose veins treatment. In addition, it is thought that these phantoms could be applied to the development of varicose vein treatment device using the focused ultrasound and the verification of the therapeutic effect.

Integrity evaluation of rock bolt grouting using ultrasonic transmission technique (초음파 투과법을 이용한 록볼트 그라우팅의 건전도 평가)

  • Han, Shin-In;Lee, Jong-Sub;Lee, Yong-Jun;Nam, Seok-Woo;Lee, In-Mo
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.9 no.1
    • /
    • pp.75-82
    • /
    • 2007
  • As one of the main support systems, rock bolts play a crucial role in the reinforcement of tunnels. Numerical and experimental studies using a transmission method of ultrasonic guided waves are performed to evaluate the integrity of rock bolts encapsulated by grouting paste. Numerical simulations using "DISPERSE" are carried out for the selection of the optimal experimental setup, i.e. non-destructive testing (NDT) system of the rock bolt. Based on results of the numerical simulation, the calculated frequency range for NDT testing is between 20kHz and 70kHz with the first longitudinal L(1) mode. Laboratory transmission tests are performed by attaching the piezo electric sensor at the tip of the rock bolt before embedding. Both of analytical and experimental results show that the amplitude of signals as well as the wave velocity increases with increase in the defect ratio of grouting paste. The defect in grouting paste means that the space around the rock bolt is not fully filled with the grouting paste. Experimental results also show that the increase of the wave velocity is more sensitive to the defect ratio increase than that of the amplitude. This study demonstrates that the transmission technique of ultrasonic guided waves may be a valuable tool in the evaluation of the rock bolt integrity.

  • PDF

Differentiation of Adductor-Type Spasmodic Dysphonia from Muscle Tension Dysphonia Using Spectrogram (스펙트로그램을 이용한 내전형 연축성 발성 장애와 근긴장성 발성 장애의 감별)

  • Noh, Seung Ho;Kim, So Yean;Cho, Jae Kyung;Lee, Sang Hyuk;Jin, Sung Min
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.28 no.2
    • /
    • pp.100-105
    • /
    • 2017
  • Background and Objectives : Adductor type spasmodic dysphonia (ADSD) is neurogenic disorder and focal laryngeal dystonia, while muscle tension dysphonia (MTD) is caused by functional voice disorder. Both ADSD and MTD may be associated with excessive supraglottic contraction and compensation, resulting in a strained voice quality with spastic voice breaks. The aim of this study was to determine the utility of spectrogram analysis in the differentiation of ADSD from MTD. Materials and Methods : From 2015 through 2017, 17 patients of ADSD and 20 of MTD, underwent acoustic recording and phonatory function studies, were enrolled. Jitter (frequency perturbation), Shimmer (amplitude perturbation) were obtained using MDVP (Multi-dimensional Voice Program) and GRBAS scale was used for perceptual evaluation. The two speech therapist evaluated a wide band (11,250 Hz) spectrogram by blind test using 4 scales (0-3 point) for four spectral findings, abrupt voice breaks, irregular wide spaced vertical striations, well defined formants and high frequency spectral noise. Results : Jitter, Shimmer and GRBAS were not found different between two groups with no significant correlation (p>0.05). Abrupt voice breaks and irregular wide spaced vertical striations of ADSD were significantly higher than those of MTD with strong correlation (p<0.01). High frequency spectral noise of MTD were higher than those of ADSD with strong correlation (p<0.01). Well defined formants were not found different between two groups. Conclusion : The wide band spectrograms provided visual perceptual information can differentiate ADSD from MTD. Spectrogram analysis is a useful diagnostic tool for differentiating ADSD from MTD where perceptual analysis and clinical evaluation alone are insufficient.

  • PDF

A Study on the Performance of Companding Algorithms for Digital Hearing Aid Users (디지털 보청기 사용자를 위한 압신 알고리즘의 성능 연구)

  • Hwang, Y.S.;Han, J.H.;Ji, Y.S.;Hong, S.H.;Lee, S.M.;Kim, D.W.;Kim, In-Young;Kim, Sun-I.
    • Journal of Biomedical Engineering Research
    • /
    • v.32 no.3
    • /
    • pp.218-229
    • /
    • 2011
  • Companding algorithms have been used to enhance speech recognition in noise for cochlea implant users. The efficiency of using companding for digital hearing aid users is not yet validated. The purpose of this study is to evaluate the performance of the companding for digital hearing aid users in the various hearing loss cases. Using HeLPS, a hearing loss simulator, two different sensorinerual hearing loss conditions were simulated; mild gently sloping hearing loss(HL1) and moderate to steeply sloping hearing loss(HL2). In addition, a non-linear compression was simulated to compensate for hearing loss using national acoustic laboratories-non-linear version 1(NAL-NL1) in HeLPS. In companding, the following four different companding strategies were used changing Q values(q1, q2) of pre-filter(F filter) and post filter(G filter). Firstly, five IEEE sentences which were presented with speech-shaped noise at different SNRs(0, 5, 10, 15 dB) were processed by the companding. Secondly, the processed signals were applied to HeLPS. For comparison, signals which were not processed by companding were also applied to HeLPS. For the processed signals, log-likelihood ratio(LLR) and cepstral distance(CEP) were measured for evaluation of speech quality. Also, fourteen normal hearing listeners performed speech reception threshold(SRT) test for evaluation of speech intelligibility. As a result of this study, the processed signals with the companding and NAL-NL1 have performed better than that with only NAL-NL1 in the sensorineural hearing loss conditions. Moreover, the higher ratio of Q values showed better scores in LLR and CEP. In the SRT test, the processed signals with companding(SRT = -13.33 dB SPL) showed significantly better speech perception in noise than those processed using only NAL-NL1(SRT = -11.56 dB SPL).

A Study on the Efficiency of Hand-Knee Position in GB Stone Ultrasonography (담낭결석 초음파검사에서 Hand-Knee position의 효율성에 관한 연구)

  • Park, Soung-Ock;Do, Yun-Su
    • Journal of radiological science and technology
    • /
    • v.29 no.4
    • /
    • pp.267-274
    • /
    • 2006
  • The evaluation of GB stones with ultrasound has proved to be useful procedure in patient with symptoms of cholelithiasis. GB is evaluated for size, wall thickness, presence of internal reflections within the lumen and posterior acoustic shadowing or enhancement in Ultrsonography. The patient position should be shifted during procedure to demonstrate further the presence of stone within the GB. Patient scanned at the Rt. subcostal region in supine, right lateral, Lt. down decubitus, and upright sitting position. So GB stone should shift to dependent area of GB. Often, GB is not markedly distended in the presence of cholethiasis, and so the diagnosis becomes more difficult. One of the more difficult areas for detection of a GB stones are embeded in the cystic duct region. And since the GB is adjacent to the duodenum and hepatic flexure, its may be difficult to visualizing a GB stone. When patient study position changes frome supine to other position, stones displaced the site. But if its are polyps, not changes the site whatever patient positions. It is very important to what make different GB stones or polyps. We have studied about mobility of GB stones according to the patients position(supine, Lt. down decubitus, $30^{\circ} LAO. sitting and hand-knee). So we have a result, stones wherever localized within the GB, changed 100% its position in the hand-knee position and the others appeared at least 90%. In this study, when a large stones are located through fundus-body and body-neck, does not changing the stones position in spite of varied patient's positions. But hand-knee positions can identified GB stones, because its make changed the position of stons from posterior wall to anterior wall within the GB. We recommend the hand-knee position for differentiation GB stones from polyps.

  • PDF

Integrity evaluation of grouting in umbrella arch methods by using guided ultrasonic waves (유도초음파를 이용한 강관보강다단 그라우팅의 건전도 평가)

  • Hong, Young-Ho;Yu, Jung-Doung;Byun, Yong-Hoon;Jang, Hyun-Ick;You, Byung-Chul;Lee, Jong-Sub
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.15 no.3
    • /
    • pp.187-199
    • /
    • 2013
  • Umbrella arch method (UAM) used for improving the stability of the tunnel ground condition has been widely applied in the tunnel construction projects due to the advantage of obtaining both reinforcement and waterproof. The purpose of this study is to develop the evaluation technique of the integrity of bore-hole in UAM by using a non-destructive test and to evaluate the possibility of being applied to the field. In order to investigate the variations of frequency depending on grouted length, the specimens with different grouted ratios are made in the two constraint conditions (free boundary condition and embedded condition). The hammer impact reflection method in which excitation and reception occur simultaneously at the head of pipe was used. The guided waves generated by hitting a pipe with a hammer were reflected at the tip and returned to the head, and the signals were received by an acoustic emission (AE) sensor installed at the head. For the laboratory experiments, the specimens were prepared with different grouted ratios (25 %, 50 %, 75 %, 100 %). In addition, field tests were performed for the application of the evaluation technique. Fast Fourier transform and wavelet transform were applied to analyze the measured waves. The experimental studies show that grouted ratio has little effects on the velocities of guided waves. Main frequencies of reflected waves tend to decrease with an increase in the grouted length in the time-frequency domain. This study suggests that the non-destructive tests using guided ultrasonic waves be effective to evaluate the bore-hole integrity of the UAM in the field.

Evaluation of Mechanical and Interfacial Properties between Glass Fiber and Epoxy Resin after NaCl Solution and Aging Treatments (염수 노화처리 일수에 따른 유리섬유 에폭시간의 기계적 및 계면 물성 변화 평가)

  • Shin, Pyeong-Su;Wang, Zuo-Jia;Kwon, Dong-Jun;Choi, Jin-Yeong;Lee, Sang-Il;Park, Joung-Man
    • Composites Research
    • /
    • v.28 no.1
    • /
    • pp.22-27
    • /
    • 2015
  • Although it is important to have high strength of each of fiber and matrix, interface between fiber and matrix is most important. If NaCl water penetrates the interface, that area will be weak. So experiment about increasing interfacial strength is in process. In this study, the change of properties by mechanical, interfacial and micromechanical tests was observed after NaCl and aging treatment. The changes in mechanical properties of glass fiber were investigated using single-fiber tensile test. Interfacial properties between glass fiber and epoxy resin were evaluated using nondestructive acoustic emission (AE) and micromechanical test applied to fatigue test. Through change of fatigue properties, relative interfacial properties were evaluate. In conclusion, glass fiber diameter decreased and the reduction of mechanical and interfacial was observed with NaCl solution and aging treatment.

Internal Defection Evaluation of Spot Weld Part and Carbon Composite using the Non-contact Air-coupled Ultrasonic Transducer Method (비접촉 초음파 탐상기법을 이용한 스폿용접부 및 탄소복합체의 내부 결함평가)

  • Kwak, Nam-Su;Lee, Seung-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.11
    • /
    • pp.6432-6439
    • /
    • 2014
  • The NAUT (Non-contact Air coupled Ultrasonic Testing) technique is one of the ultrasonic testing methods that enables non-contact ultrasonic testing by compensating for the energy loss caused by the difference in acoustic impedance of air with an ultrasonic pulser receiver, PRE-AMP and high-sensitivity transducer. As the NAUT is performed in a state of steady ultrasonic transmission and reception, testing can be performed on materials of high or low temperatures or specimens with a rough surface or narrow part, which could not have been tested using the conventional contact-type testing technique. For this study, the internal defects of spot weld, which are often applied to auto parts, and CFRP parts, were tested to determine if it is practical to make the NAUT technique commercial. As the spot welded part had a high ultrasonic transmissivity, the result was shown as red. On the other hand, the part with an internal defect had a layer of air and low transmissivity, which was shown as blue. In addition, depending on the PRF (Pulse Repetition Frequency), an important factor that determines the measurement speed, the color sharpness showed differences. With the images obtained from CFRP specimens or an imaging device, it was possible to identify the shape, size and position of the internal defect within a short period of time. In this paper, it was confirmed in the above-described experiment that both internal defect detection and image processing of the defect could be possible using the NAUT technique. Moreover, it was possible to apply NAUT to the detection of internal defects in the spot welded parts or in CFRP parts, and commercialize its practical application to various fields.

Aerodynamic Study in Normal Korean and Patients with Vocal Polyp (정상인과 성대용종 환자에서의 공기역학적 검사)

  • 서장수;송시연;정유선;김정수;지덕환;이무경
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.10 no.1
    • /
    • pp.5-11
    • /
    • 1999
  • Background and Objectives : Recently, many people suffering from voice change visit otolaryngologist. So, it is important to study vocal function in patients with glottic or laryngeal disease. Aerodynamic investigation is valuable information about the efficiency of the larynx in translating air pressure to acoustic signal. The purpose of this study was to investigate the aerodynamic data in patients with vocal polyp, compare this data with that of the normal Korean. Materials and Methods : In aerodynamic study, maximum phonation time, mean air flow rate, phonatory flow volume and subglottal pressure were tested by using Aerophone II voice function analyzer in 157 normal korean and 143 patients with vocal polyp, aged from 20 to 69 years randomly selected. Results and Conclusion : In vocal polyp, maximum phonation time was significantly decreased and mean air How rate was increased. Phonatory flow volume was significantly decreased and subglottic pressure was increased only in female with vocal polyp. These data will be served as basic data of evaluation after treatment and postoperative assessment of the patients with vocal polyp.

  • PDF

Exploration of Optimal Multi-Core Processor Architecture for Physical Modeling of Plucked-String Instruments (현악기의 물리적 모델링을 위한 최적의 멀티코어 프로세서 아키텍처 탐색)

  • Kang, Myeong-Su;Choi, Ji-Won;Kim, Yong-Min;Kim, Jong-Myon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.30 no.5
    • /
    • pp.281-294
    • /
    • 2011
  • Physics-based sound synthesis usually requires high computational costs and this results in a restriction of its use in real-time applications. This motivates us to implement the sound synthesis algorithm of plucked-string instruments using multi-core processor architectures and determine the optimal processing element (PE) configuration for the target instruments. To determine the optimal PE configuration, we evaluate the impacts of a sample-per-processing element (SPE) ratio that is defined as the amount of sample data directly mapped to each PE on system performance and both area and energy efficiencies using architectural and workload simulations. For the acoustic guitar, the highest area and energy efficiencies are achieved at a SPE ratio of 5,513 and 2,756, respectively, for the synthesis of musical sounds sampled at 44.1 kHz. In the case of the classical guitar, the maximum area and energy efficiencies are achieved at a SPE ratio of 22,050 and 5,513, respectively. In addition, the synthetic sounds were very similar to original sounds in their spectra. Furthermore, we conducted MUSHRA subjective listening test with ten subjects including nine graduate students and one professor from the University of Ulsan, and the evaluation of the synthetic sounds was excellent.