• Title/Summary/Keyword: acoustic emission count

Search Result 70, Processing Time 0.024 seconds

Study of Fracture Toughness Measurement and Fracture Stability Evaluation by Acoustic Emission Method (음향 방출법에 의한 파괴 인성치 측정 및 파괴 안정성 평가를 위한 연구)

  • 이강용;백충헌
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.13 no.1
    • /
    • pp.96-104
    • /
    • 1989
  • The behaviors of acoustic emission emitted in the tests of the fracture toughness and fracture stability are observed by using the specimens of aluminum 2024-T351 and 7039-T6 alloys. The empirical eqution of J-R curve is derived. It is demonstrated from the comparison of the fracture toughness obtained from J-R curve with that from ASTM standard E813-81 that the latter is larger than the former. The discontinuous point in the log-log graph of J-integral vs. total acoustic emission count is observed in between the two offset lines referred from ASTM standard E813-81, but it's physical meaning is uncretain. An empirical material tearing modulus is derived in terms of the total acoustic emission count and proved to be valid in fracture instability test.

Study of Acoustic Emission Parameters Involved in Burst Test for CNG-Vehicle Fuel Tank (자동차용 CNG 연료탱크의 파열시험시 발생하는 음향방출변수 분석)

  • Jee, Hyun-Sup;Lee, Jong-O;Ju, No-Hoe;Lee, Jong-Kyu
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.9
    • /
    • pp.1131-1136
    • /
    • 2011
  • This study is performed on the acoustic emission parameters involved in a burst test for a CNG-vehicle fuel tank. A resonant AE sensor with a central frequency of 150 kHz was attached on the composite materials in the center of the fuel tank. The analysis of AE parameters such as hit, amplitude, count, duration, risetime, and signal strength during load holding was performed. The total count and total signal strength are effective tools for the damage evaluation of a CNG fuel tank.

A Study on Comparison of Acoustic Emission, Ultrasonic Testing and Crack Gauge Method in 3-point Bending Testing (3점 굽힘시험에 있어서 AE, 초음파, 크랙게이지법의 비교연구)

  • Han, E.K.;Kim, K.S.;Park, J.S.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.10 no.1
    • /
    • pp.65-72
    • /
    • 1990
  • Comparison of acoustic emission, ultrasonic testing and crack gauge in 3-point bending testing have been studied. As the results, COD is indirectly assumed by strain gauge rate and grid pitch width when crack gauge grid is out. Acoustic emission is qualitatively able to measure crack growth by total count but ultrasonic testing has a difficulty in measuring it because of echo height fluctuation according to the change and pressure of UT. probe.

  • PDF

Acoustic Emission Characteristics of Ceramic Coated Steel by Plasma Spraying (플래즈머용사에 의한 세라믹 코팅 강재의 음향방출 특성)

  • Kim, G.S.
    • Journal of Power System Engineering
    • /
    • v.2 no.3
    • /
    • pp.49-54
    • /
    • 1998
  • This paper is investigated of hardness and adhesiveness of plasma sprayed coating steels by AE(Acoustic Emission) testing when loading a tensile. AE Parameters used are Event, Count, Energy and Amplitude. Test specimens are carbon steel(S45C) with sprayed coating layers of Ni-4.5wt.%Al(bond coating) and $TiO_2$(top coating), and carry out heat treatment at $800^{\circ}C\;and\;1000^{\circ}C$, respectively. The micro-hardness of the heat treatment specimen have been improved more than that of non-heat treatment. On the tensile test, the process and occurence of the exfoliation of the sprayed coating layer can be estimated by AE Characteristics of AE parameters, such as event, count, amplitude and energy, on the layer exfoliation are shown the similar aspects. The exfoliation of bond coating occure at about 20% of strain and top coating is about 5% of strain.

  • PDF

Evaluation and monitoring of degradation mechanism of Li-ion battery for portable electronic device (휴대전자기기용 저용량 리튬이온 배터리의 충방전 열화 기구 분석 및 모니터링)

  • Byeon, Jai Won
    • Journal of Applied Reliability
    • /
    • v.13 no.2
    • /
    • pp.129-140
    • /
    • 2013
  • As a fundamental experimental study for reliability improvement of lithium ion secondary battery, degradation mechanism was investigated by microscopic observation and acoustic emission monitoring. Microstructural observation of the decomposed battery after cycle test revealed mechanical and chemical damages such as interface delamination, microcrack of the electrodes, and solid electrolyte interphase (SEI). Acoustic emission (AE) signal was detected during charge and discharge of lithium ion battery to investigate relationships among cumulative count, discharge capacity, and microdamages. With increasing number of cycle, discharge capacity was decreased and AE cumulative count was observed to increase. Observed damages were attributed to sources of the detected AE signals.

A study on the characteristics of acoustic emission signal in dynamic cutting process (동적 절삭과정에서 AE 신호의 특성에 관한 연구)

  • Kim, Jeong-Suk;Kang, Myeong-Chang;Kim, Duk-Whan
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.11 no.4
    • /
    • pp.69-76
    • /
    • 1994
  • AE(Acoustic Emission) signal is correlated to workpiece material, cutting conditions and tool geometry during metal cutting. The relationship between AE signal and cutting parameters can be obtained by theoretical model and experiments. The value of CR(Count Rate) is nearly constant in stable cutting, but when the chatter vibration occours, the value of CR is rapidly increased due to the vibration deformation zone. By experimental signal processing of AE, it is more effective than by RMS(Root Mean Square) measurement to detect the threshold of chatter vibration by CR measurement.

  • PDF

A Study on the Characteristics of Electronic Magnetic Interference(EMI) in Acoustic Emission Testing for Corrosion Detection of Ground Tank (지상탱크의 부식감지를 위한 음향방출시험에서 발생한 전자기간섭신호의 특성 연구)

  • Kim, Sung-Dai;Jung, Woo-Gwang
    • Korean Journal of Materials Research
    • /
    • v.17 no.5
    • /
    • pp.239-243
    • /
    • 2007
  • The evaluation and comparison have been made for the EMI noise which was included in the signal from the sensors in the acoustic emission testing for the bottom plate of ground tank at full. The EMI signal has been classified into two types. One is the signal with very short AE count, and this signal possibly can be filtered by front end filter setting of the channel count with low level of 4 and high level of $10^8$. The other EMI signal occurred from CH 1, CH 3 and CH 10, and had high and constant duration with high energy and count (maximun duration > $10^5\;{\mu}s$), and has characteristic gradient of accumulation amplitude distribution. This signal should be removed in the AE signal evaluation by filtering, because this may affect to the total gradient.

Pattern Classification of Acoustic Emission Signals During Wood Drying by Artificial Neural Network (인공신경망을 이용한 목재건조 중 발생하는 음향방출 신호 패턴분류)

  • 김기복;강호양;윤동진;최만용
    • Journal of Biosystems Engineering
    • /
    • v.29 no.3
    • /
    • pp.261-266
    • /
    • 2004
  • This study was Performed to classify the acoustic emission(AE) signal due to surface cracking and moisture movement in the flat-sawn boards of oak(Quercus Variablilis) during drying using the principal component analysis(PCA) and artificial neural network(ANN). To reduce the multicollinearity among AE parameters such as peak amplitude, ring-down count event duration, ring-down count divided by event duration, energy, rise time, and peak amplitude divided by rise time and to extract the significant AE parameters, correlation analysis was performed. Over 96 of the variance of AE parameters could be accounted for by the first and second principal components. An ANN analysis was successfully used to classify the Af signals into two patterns. The ANN classifier based on PCA appeared to be a promising tool to classify the AE signals from wood drying.

Acoustic emission characteristics under the influence of different stages of damage in granite specimens

  • Jong-Won Lee;Tae-Min Oh;Hyunwoo Kim;Min-Jun Kim;Ki-Il Song
    • Geomechanics and Engineering
    • /
    • v.37 no.2
    • /
    • pp.149-166
    • /
    • 2024
  • The acoustic emission (AE) technique is utilized to estimate the rock failure status in underground spaces. Understanding the AE characteristics under loading conditions is essential to ensure the reliability of AE monitoring. The AE characteristics depend on the material properties (p-wave velocity, density, UCS, and Young's modulus) and damage stages (stress ratio) of the target rock mass. In this study, two groups of granite specimens (based on the p-wave velocity regime) were prepared to explore the effect of material properties on AE characteristics. Uniaxial compressive loading tests with an AE measurement system were performed to investigate the effect of the rock properties using AE indices (count index, energy index, and amplitude index). The test results were analyzed according to three damage stages classified by the stress ratio of the specimens. Count index was determined to be the most suitable AE index for evaluating rock mass stability.

A Study on the Correlation of Orthogonal Cutting all sorts Parameter and Acoustic Emission Signal (2차원 절삭시의 각종 파라메터와 음향 방출 신호와의 상호 관계에 관한 연구)

  • Kim, Jae-Yeol;Sim, Jae-Gi;Park, Hwan-Gyu;O, Hwan-Gyo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.8 no.1
    • /
    • pp.74-83
    • /
    • 1991
  • A study on the Correlation of Orthogonal Cutting Parameter (Cutting speed, Depth of cut, Feed Rate) and Acoustic Emission Signal. It is well known that acoustic emission (AE) is the emission of elastic wave resulting from the deformation and fracture of materials. This study estabished correlation of orthogonal cutting parameter and AE signal, and researched into in-process monitoring of tool wear and failure. The results are as follow; 1. AE RMS was under the influence of cutting speed but hardly influenced by depth of cut and feed rate. 2. AE RMS was under the influence of flank wear. 3. AE count rate increased by increased cutting speed. 4. AE RMS value was rapidly increased in 130 m flank wear.

  • PDF