• Title/Summary/Keyword: acoustic characteristic

Search Result 433, Processing Time 0.03 seconds

Acoustic characteristics of speech-language pathologists related to their subjective vocal fatigue (언어재활사의 주관적 음성피로도와 관련된 음향적 특성)

  • Jeon, Hyewon;Kim, Jiyoun;Seong, Cheoljae
    • Phonetics and Speech Sciences
    • /
    • v.14 no.3
    • /
    • pp.87-101
    • /
    • 2022
  • In addition to administering a questionnaire (J-survey), which questions individuals on subjective vocal fatigue, voice samples were collected before and after speech-language pathology sessions from 50 female speech-language pathologists in their 20s and 30s in the Daejeon and Chungnam areas. We identified significant differences in Korean Vocal Fatigue Index scores between the fatigue and non-fatigue groups, with the most prominent differences in sections one and two. Regarding acoustic phonetic characteristics, both groups showed a pattern in which low-frequency band energy was relatively low, and high-frequency band energy was increased after the treatment sessions. This trend was well reflected in the low-to-high ratio of vowels, slope LTAS, energy in the third formant, and energy in the 4,000-8,000 Hz range. A difference between the groups was observed only in the vowel energy of the low-frequency band (0-4,000 Hz) before treatment, with the non-fatigue group having a higher value than the fatigue group. This characteristic could be interpreted as a result of voice abuse and higher muscle tonus caused by long-term voice work. The perturbation parameter and shimmer local was lowered in the non-fatigue group after treatment, and the noise-to-harmonics ratio (NHR) was lowered in both groups following treatment. The decrease in NHR and the fall of shimmer local could be attributed to vocal cord hypertension, but it could be concluded that the effective voice use of speech-language pathologists also contributed to this effect, especially in the non-fatigue group. In the case of the non-fatigue group, the rhamonics-to-noise ratio increased significantly after treatment, indicating that the harmonic structure was more stable after treatment.

Hydrography and Circulation in the Youngsan River Estuary in Summer, 2000 (2000년 여름 영산강 하구의 해수 특성과 순환)

  • Cho, Yang-Ki;Cho, Cheol;Sun, Youn-Jong;Park, Kyung-Yang;Park, Lae-Hwan
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.6 no.4
    • /
    • pp.218-224
    • /
    • 2001
  • Water movement in the Young San River Estuary where a sea dyke was constructed, was observed using anacoustic doppler profiler (ADP) and two TGPS buoys for 25 hours on 27-28 July 2000. Hydrographic observations were simultaneously taken using CTD to understand the characteristic of the spacial structure of temperature and salinity. A large quantity of fresh water was discharged from the sea dyke on 26 July 2000. The observation period fell on neap tide. The amplitude of the tidal elevation and the maximum velocity of the tidal current were about 4 m and 12 cm/sec respectively. The water movement at the surface layer is mainly controlled by wind, and those at the other layers are controlled by semidiurnal tide. The low salinity water less than 22 psu was observed along the northern part during the early observation period while southerly wind prevails. The less saline water moves westward and finally leaves the estuary by easterly wind early on the second day. We can divide the vertical structure into four layers by hydrography and current structure. Mean velocity structure shows that relatively less saline waters at the surface and the middle layer move seaward, and the waters at the upper and the bottom layers move landward. It is thought that the intermittent discharge of river water from the sea dyke makes vertical structure of four layers.

  • PDF

Hydroacoustic Observations on the Diel Distribution and Activity Patterns of Fishes in the East China Sea II -Activity Patterns during the Evening and Morning Transition Periods - (동중국해에 있어서 어족생물의 일주기적 유영행동특성에 관한 연구-I-획야 전이시간대의 유영행동특성-)

  • 이대재
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.30 no.4
    • /
    • pp.239-250
    • /
    • 1994
  • The vertical distribution and activity patterns of fishes during the evening and morning transitions between day and night were studied acoustically and by bottom trawling in November 1990-1992 in thermally stratified waters of the East China Sea. The acoustic data were collected from six stations with a scientific echo-sounder operating at two frequencies of 25 and 100kHz, and the echograms were used to determine the vertical distributions of fish. Biological sampling was accomplished by bottom trawling to identify fish species recorded on the echograms, and the species and length compositions were determined. At each station, vertical profiles of water temperature, salinity and dissolved oxygen were taken with a CTD system and were related to the diel movements and the depth distributions of fish. During the day most fish were within several meters above bottom, but began to migrate upwards just before sunset, and during the night they were dispersed in midwater. Prior to sunrise with a thermocline present, one group of the fish aggregation occurred in dense schools slightly above the thermocline, while the other group occurred with the numerous single fish-traces bellow it. These groups of aggregations rapidly began to migrate toward the bottom across the thermocline from about 40 min before sunrise. Trawl hauls in the bottom strata below the thermocline with the characteristic single fish traces yieled invariably catches dominated by snailfish and fishing frog with minor quantities of other species in all stations. Hence, the results indicate that snailfish and fishing frog were the dominated scatterers in the depth strata below the thermocline, and the single-fish recordings were mainly snailfish. The fish species such as anchovy and juvenile mackerel in bottom trawl catches is poorly represented in relation to the mesh selectivity of the trawl net, but their occurrence suggest that the fish-school recording above the thermocline were due to these species which migrated vertically across the thermocline, with a temperature gradient of about 8$^{\circ}C$, from the water layers near the bottom at night. Accordingly, we conclude that the vertical distribution and activity patterns of snailfish were strongly temperature dependent and in the termally stratified waters, the upper limit to diel activity was closely linked to the position of the thermocline.

  • PDF

A Study on the Multi-Carrier System for Throughput Enhancement in Underwater Channel Environments (수중 채널 환경에서 전송량 증대를 위한 다중반송파 시스템에 관한 연구)

  • Kim, Min-sang;Cho, Dae-young;Ko, Hak-lim;Hong, Dae-Ki;Kim, Seung-geun;Im, Tae-ho
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.40 no.6
    • /
    • pp.1193-1199
    • /
    • 2015
  • Studies applying multiple carrier method such as OFDM(Orthogonal Frequency Division Multiplexing) or FMT(Filtered Multi-Tone) to Underwater acoustic communication(UAC) system are actively under way as UAC is utilized in the various fields and the demand of high speed data transmission increases. In the existing OFDM method, the use of virtual carrier, which is inserted not to affect the adjacent channel in the frequency domain, and the cyclic prefix, which is used to reduce the impact of Inter Symbol Interference and Inter Channel Interference, decrease the throughput. In particular, the length of cyclic prefix to be used becomes longer under water since underwater has a rapidly changing channel characteristic, and the data throughput diminishes because it has to allocate more subcarrier on virtual carrier. This study therefore suggests FMT-OFDM system, a combination of OFDM and FMT, for the purpose of enhanced throughput in the underwater channel environment. Besides, in this study, channel is modeled based on data measured in real sea and the performance is analyzed after setting system parameters.

Characteristics of respiration and phonation depending on smoking or non smoking by practical musicology students and general male students (실용음악전공학생과 일반남학생의 흡연여부에 따른 호흡과 발성 특성 비교)

  • Kim, Eunhye;Choi, Hong-Shik;Lim, Seong-Eun;Choi, Yaelin
    • Phonetics and Speech Sciences
    • /
    • v.6 no.3
    • /
    • pp.49-56
    • /
    • 2014
  • This research compared the features of respiration and phonation between practical musicology students and general male students, according to their smoking status. Participants of this research are 15 practical musicology male students attending ${\bigcirc}{\bigcirc}$ university and 16 general ${\bigcirc}{\bigcirc}{\bigcirc}$ university students. The participants, both non-smokers and smokers with 5-years of smoking history have no history of voice disease in any case and have normal cognitive functions. The results indicated that, first, there is not a notable difference in the respiratory activity status(FVC, FEV1, FEV1/FVC), regardless of major and smoking status. In MPT, even though there is no significant difference in accordance with their majors, considering smoking status, the smoker group was shorter than non-smoker group significant difference statistically (p<.01). Second, the divisions of participants' major did not show significant difference in Fo, jitter, shimmer, and NHR in the vowel prolongation task. However, the smoker group showed a significantly higher degree of jitter and shimmer than the non-smoker group (p<.05) as Fo and NHR shows no difference. In the case of VRP, maximum frequency and frequency range of the practical group are significantly higher than normal group statistically (p<.001). Moreover, although the difference of the minimum frequency shown at the statistic is not significant, practical group showed a higher tendency of frequency than normal group (p=.051). In conclusion, even though there is no difference in respiratory activity between the smoker group and non-smoker group, the MPT of the smoker group is shorter than that of non-smoker group. In addition, the smoker group showed a higher degree of jitter and shimmer than the non-smoker group. MPT is related to the valve action of vocal fold that passes through the glottis. Thus, it is interpreted that the smoker group has a lower quality of voice and valve action of the vocal fold. Also, the practical group has a higher degree of maximum frequency and frequency range than the normal group. This research can function as basic data for vocal characteristics for the majors in relation to the voice-specializing.

Implementation of an LTCC RF Front-End Module Considering Parasitic Elements for Wi-Fi and WiMAX Applications (기생 성분을 고려한 Wi-Fi와 WiMAX용 LTCC 무선 전단부 모듈의 구현)

  • Kim, Dong-Ho;Baek, Gyung-Hoon;Kim, Dong-Su;Ryu, Jong-In;Kim, Jun-Chul;Park, Jong-Chul;Park, Chong-Dae
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.4
    • /
    • pp.362-370
    • /
    • 2010
  • In this paper, a compact RF Front-end module for Wireless Fidelity(Wi-Fi) and Worldwide Interoperability for Microwave Access(WiMAX) applications is realized by low temperature co-fired ceramic(LTCC) technology. The RF Front-end module is composed of three LTCC band-pass filters, a Film Bulk Acoustic Resonator(FBAR) filter, fully embedded matching circuits, an SPDT switch for mode selection, an SPDT switch for Tx/Rx selection, and an SP4T switch for band selection. The parasitic elements of 0.2~0.3 pF are generated by the structure of stacking in the top pad pattern for DC block capacitor of SPDT switch for mode selection. These kinds of parasitic elements break the matching characteristic, and thus, the overall electrical performance of the module is degraded. In order to compensate it, we insert a parallel lumped-element inductor on capacitor pad pattern for DC block, so that we obtain the optimized performance of the RF Front-end module. The fabricated RF front-end module has 12 layers including three inner grounds and it occupies less than $6.0mm{\times}6.0mm{\times}0.728mm$.

Measurement and Analysis for the Upper Side Flow Boundary Layer of a High Speed Train Using Wind Tunnel Experiments with a Scaled Model (축소모형 풍동시험을 이용한 고속열차의 유동 상부경계층 측정 및 분석)

  • Oh, Hyuck Keun;Kwon, Hyeok-bin;Kwak, Minho;Kim, Seogwon;Park, Choonsoo
    • Journal of the Korean Society for Railway
    • /
    • v.19 no.1
    • /
    • pp.11-19
    • /
    • 2016
  • The flows around a high speed train are very important because they could affect the aerodynamic characteristics such as drag and acoustic noise. Especially the boundary layer of flows could represent the characteristic of flows around the high speed train. Most previous studies have focused on the boundary layer region along the train length direction for the side of the train and underbody. The measurement and analysis of the boundary layer for the roof side is also very important because it could determine the flow inlet condition for the pantograph. In this study, the roof boundary layer was measured with a 1/20 scaled model of the next generation high speed train, and the results were compared with full-scaled computational fluid dynamics results to confirm their validity. As a result, it was confirmed that the flow inlet condition for the pantograph is about 85% of the train speed. Additionally, the characteristics of the boundary layer, which increases along the train direction, was also analyzed.

Study on frequency response of implantable microphone and vibrating transducer for the gain compensation of implantable middle ear hearing aid (이식형 마이크로폰과 진동체를 갖는 인공중이의 이득 보상을 위한 주파수 특성 고찰)

  • Jung, Eui-Sung;Seong, Ki-Woong;Lim, Hyung-Gyu;Lee, Jang-Woo;Kim, Dong-Wook;Lee, Jyung-Hyun;Kim, Myoung-Nam;Cho, Jin-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.19 no.5
    • /
    • pp.361-368
    • /
    • 2010
  • ACROSS device, which is composed of an implantable microphone, a signal processor, and a vibrating transducer, is a fullyimplantable middle ear hearing device(F-IMEHD) for the recovery of patients with hearing loss. And since a microphone is implanted under skin and tissue at the temporal bones, the amplitude of the sound wave is attenuated by absorption and scattering. And the vibrating transducer attached to the ossicular chain caused also the different displacement from characteristic of the stapes. For the gain control of auditory signals, most of implantable hearing devices with the digital audio signal processor still apply to fitting rules of conventional hearing aid without regard to the effect of the implanted microphone and the vibrating transducer. So it should be taken into account the effect of the implantable microphone and the vibrating transducer to use the conventional audio fitting rule. The aim of this study was to measure gain characteristics caused by the implanted microphone and the vibrating transducer attached to the ossicle chains for the gain compensation of ACROSS device. Differential floating mass transducers (DFMT) of ACROSS device were clipped on four cadaver temporal bones. And after placing the DFMT on them, displacements of the ossicle chain with the DFMT operated by 1 $mA_{peak}$ current was measured using laser Doppler vibrometer. And the sensitivity of microphones under the sampled pig skin and the skin of 3 rat back were measured by stimulus of pure tones in frequency from 0.1 to 8.9 kHz. And we confirmed that the microphone implanted under skin showed poorer frequency response in the acoustic high-frequency band than it in the low- to mid- frequency band, and the resonant frequency of the stapes vibration was changed by attaching the DFMT on the incus, the displacement of the DFMT driven with 1 $mA_{rms}$ was higher by the amount of about 20 dB than that of cadaver's stapes driven by the sound presssure of 94 dB SPL in resonance frequency range.

A study on the Frequency Analysis Function of the Auricle Using A Notch Filter

  • Park, Dong-Cheol
    • International journal of advanced smart convergence
    • /
    • v.10 no.4
    • /
    • pp.241-255
    • /
    • 2021
  • The human auricle is the first part to receive sound from the outside. In this part, the frequency range of human recognizable form is divided and organized. In this study, we propose modeling by applying a single sound source to the surface of the human auricle. This means that when the sound pressure of a low frequency (low frequency) sound enters the pinna, the impedance felt at the tip of a part of the non-linear surface of the pinna is mainly due to the tensile force at the end of the part of the non-linear surface of the pinna. By expressing the situation of moving at a very small speed, the characteristic impedance of the pinna was confirmed to be negative infinity, and it was also confirmed that the speed at the tip of a part of the non-linear surface of the pinna was 0 in the anti-resonance state. It was found that the wave propagation phenomenon that determines the characteristics of the filter is determined by how large the wavelength, kL, is compared to the length of the tip of a part of the non-straight surface of the pinna. Humans first receive sounds from outside through their ears. The auricle is non-linear and has a curved shape, and it is known that it analyzes frequencies while receiving external sounds. The human ear has an audible frequency range of 20Hz - 20,000Hz. Through the study, we applied the characteristics of the notch filter to hypothesize that the human audible frequency range is separated from the auricle, and applied filter theory to analyze it, and as a result, meaningful results were obtained. The curved part and the inner part of the auricle function as a trumpet, collecting sounds, and at the same time amplifying the weak sound of a specific band. The point was found and the shape of the envelope detected in the auricle was found. Selectivity for selecting sounds coming from the outside is the formula of the pinna that implements the function of Q. The function of distinguishing human-recognizable sound from the pinna from low to high through frequency analysis is performed in the pinna, and the 2-3kHz area, where human hearing threshold is the most sensitive, is also the acoustic impedance of the most recessed area of the pinna. It can be seen that starting from.

Notes on Descriptions of the Prosodic System in French Grammars in the Age of Enlightenment & the Departure of the International Phonetic Alphabet (계몽주의 시대 프랑스 문법서에서 기술한 운율 현상과 국제음성기호의 출발에 대한 고찰)

  • Park, Moon-Kyou
    • The Journal of the Korea Contents Association
    • /
    • v.21 no.4
    • /
    • pp.658-667
    • /
    • 2021
  • Our study aimed to analyze and reinterpret, by an acoustic approach, the descriptions of the 18th century prosody and introduce the figurative pronunciation system, which is the International Phonetic Alphabet pioneer. Our methodology compares and analyzes grammars and documents on the transcription system and restructures the prosodic structure. It is certain that the 18th century grammarians widely accepted the prosody theories made by Arnauld & Lancelot of the seventeenth century. In particular, grammar scholars accepted the dichotomous classification of the accent structures as prosodic and oratorical accents. The prosodic accent has a relation to intonation, and the oratorical accent has as its key elements intonation and intensity. Regarding the temporal structure, the lengthening of the final syllable was observed systematically by grammarians of the 18th century. This time structure is similar to that of today. Therefore, we can conclude that the final elongation, an essential characteristic of the modern French accent, has already played an imbued role in 18th century prosody. Despite this, the 18th century grammarians did not assign it the status of accent, as it was a stereotype that matches accent with intonation.