• Title/Summary/Keyword: acoustic

Search Result 8,248, Processing Time 0.038 seconds

Realization a Text Independent Speaker Identification System with Frame Level Likelihood Normalization (프레임레벨유사도정규화를 적용한 문맥독립화자식별시스템의 구현)

  • 김민정;석수영;김광수;정현열
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.3 no.1
    • /
    • pp.8-14
    • /
    • 2002
  • In this paper, we realized a real-time text-independent speaker recognition system using gaussian mixture model, and applied frame level likelihood normalization method which shows its effects in verification system. The system has three parts as front-end, training, recognition. In front-end part, cepstral mean normalization and silence removal method were applied to consider speaker's speaking variations. In training, gaussian mixture model was used for speaker's acoustic feature modeling, and maximum likelihood estimation was used for GMM parameter optimization. In recognition, likelihood score was calculated with speaker models and test data at frame level. As test sentences, we used text-independent sentences. ETRI 445 and KLE 452 database were used for training and test, and cepstrum coefficient and regressive coefficient were used as feature parameters. The experiment results show that the frame-level likelihood method's recognition result is higher than conventional method's, independently the number of registered speakers.

  • PDF

Holocene sea-level rise and paleoenvironmental changes in Korea Strait shelf (대한해협 대륙붕 해역의 홀로세 해수면 상승과 고환경변화)

  • 남승일;장정해;공기수;김성필;유동근
    • The Korean Journal of Quaternary Research
    • /
    • v.17 no.1
    • /
    • pp.7-16
    • /
    • 2003
  • A 31m-long sediment core (SSDP-102) was taken from the inner shelf (about 40m water-depth) off the northwestern coast of the Korea Strait. Detailed lithofacies and organic-geochemical analyses were performed to establish a high-resolution stratigraphy in the Korea Strait shelf and to reconstruct the paleoenvironmental changes associated with the Holocene marine transgression. The stratigraphic framework of the core was primarily established using 6 AMS $^{14}C$ ages. The sedimentary record of the core SSDP-102 allows for the reconstruction of the paleoenvironmental changes during the last 12.1 ka BP. According to the high-resolution seismic reflection profiles, lithofacies and organic-geochemical data, the core SSDP-102 can be divided into three units (III to I in ascending order) above the acoustic basement. The three units reflect distinct changes of depositional environments resulted from the post-glacial marine transgression. Therefore, it is suggested that three phases of sea-level change have occurred within the inner shelf of the Korea Strait following the Holocene marine transgression. (1) estuarine environments from ca. 12.1 to 6.2 ka BP; (2) near-shore environments with a period of decreased rising of sea level between 6.2 and 5.1 ka BP; (3) near-shore to modem marine environments after 5.1 ka BP. In particular, the present marine conditions influenced by the warm Tsushima Current have been gradually established after ca. 5.1 ka BP.

  • PDF

A study on the reliability enhancement of Ultrasonic water treatment system to boiler (보일러 초음파 수처리장치의 신뢰성향상에 관한 연구)

  • Kim, Dae-Ryong;Lee, Keun-Oh
    • Journal of Energy Engineering
    • /
    • v.22 no.3
    • /
    • pp.287-293
    • /
    • 2013
  • This study was carried out to diminish the formation of scale in boilers which is one of the defect elements when they are operating. The defect relating to scale can cause a fatal impact on the explosion of boilers due to the overheating of their tubes, or it can affect the flow of water inside boilers with its bad circulation and result in a disparity of water inside the equipment. Heat transfer in the scale is low comparing to the boiler material, so it can lead to energy losses and has also impact on the global warming. In 2005, the Korean government introduced a system which requires boiler users to install the equipment which can prevent or eliminate the formation of scale to improve the management of water quality in boilers. The study on the techniques for preventing or eliminating the formation of scale started in 1821 and since then subsequently there have been lots of similar studies. The first one was about the scale reduction using potato starch. Since an ultrasonic scale preventer developed by a scientist from a Russian acoustic institute was introduced in1993, a variety of equipment of this kind have been disseminated in Korea. There has been a need to demonstrate the condition for the best performances of such equipment. Boilers are mostly composed of the main body and 288 the tube with a circular curved surface. I carried out a demonstration study on a circular tube which affects the scale defect the most among the boiler components. As a result of it, I found out the fact that the ultrasonic wave needs to reach a certain level of sound pressure and frequency to affect the formation of scale.

Study on frequency response of implantable microphone and vibrating transducer for the gain compensation of implantable middle ear hearing aid (이식형 마이크로폰과 진동체를 갖는 인공중이의 이득 보상을 위한 주파수 특성 고찰)

  • Jung, Eui-Sung;Seong, Ki-Woong;Lim, Hyung-Gyu;Lee, Jang-Woo;Kim, Dong-Wook;Lee, Jyung-Hyun;Kim, Myoung-Nam;Cho, Jin-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.19 no.5
    • /
    • pp.361-368
    • /
    • 2010
  • ACROSS device, which is composed of an implantable microphone, a signal processor, and a vibrating transducer, is a fullyimplantable middle ear hearing device(F-IMEHD) for the recovery of patients with hearing loss. And since a microphone is implanted under skin and tissue at the temporal bones, the amplitude of the sound wave is attenuated by absorption and scattering. And the vibrating transducer attached to the ossicular chain caused also the different displacement from characteristic of the stapes. For the gain control of auditory signals, most of implantable hearing devices with the digital audio signal processor still apply to fitting rules of conventional hearing aid without regard to the effect of the implanted microphone and the vibrating transducer. So it should be taken into account the effect of the implantable microphone and the vibrating transducer to use the conventional audio fitting rule. The aim of this study was to measure gain characteristics caused by the implanted microphone and the vibrating transducer attached to the ossicle chains for the gain compensation of ACROSS device. Differential floating mass transducers (DFMT) of ACROSS device were clipped on four cadaver temporal bones. And after placing the DFMT on them, displacements of the ossicle chain with the DFMT operated by 1 $mA_{peak}$ current was measured using laser Doppler vibrometer. And the sensitivity of microphones under the sampled pig skin and the skin of 3 rat back were measured by stimulus of pure tones in frequency from 0.1 to 8.9 kHz. And we confirmed that the microphone implanted under skin showed poorer frequency response in the acoustic high-frequency band than it in the low- to mid- frequency band, and the resonant frequency of the stapes vibration was changed by attaching the DFMT on the incus, the displacement of the DFMT driven with 1 $mA_{rms}$ was higher by the amount of about 20 dB than that of cadaver's stapes driven by the sound presssure of 94 dB SPL in resonance frequency range.

Characteristics of the Horizontal Stress and the Possibility of Stress Induced Brittle Failure in Chuncheon-Yanggu Mountainous Region by the In-situ Stress Measurements (현장 측정에 의한 춘천-양구 산악지역 내 수평응력 분포와 취성파괴 가능성에 관한 연구)

  • Bae Seongho;Jeon Seokwon
    • Tunnel and Underground Space
    • /
    • v.15 no.2 s.55
    • /
    • pp.157-167
    • /
    • 2005
  • Current initial rock stress state is one of the key factors required to evaluate the stability and failure around an excavated opening and its importance increases as the construction depth become deeper and the scale of the rock structure become larger. In this paper, the study was performed to evaluate the characteristics of the regional stress state at Chuncheon-Yanggu mountainous region, the East-North part of Kyeonggi Massif. Forty nine field stress measurements in 9 boreholes were conducted at the depth from 20 m to 290 m by hydraulic fracturing method. The fracturing tracing works were carried out by acoustic televiewer scanning. The study results revealed that the different intial rock stress states presented at different formation rock type and the excessive horizontal stress state with stress ratio(K) close to 3.0 was measured at the depth of 200 m and deeper in the intrusive unite body of the study area. The results from the investigation of excessive horizontal stress and its effect on failure mode showed that there exist several points where the localized excessive horizontal stresses are big enough to potentially induce brittle failures around the future openings greater than 100 m in depth within the granite body of the study area.

True Triaxial Physical Model Experiment on Brittle Failure Grade and Failure Initiation Stress (취성파괴수준과 파괴개시시점에 관한 진삼축 모형실험연구)

  • Cheon, Dae-Sung;Park, Chan;Park, Chul-Whan;Jeon, Seok-Won
    • Tunnel and Underground Space
    • /
    • v.17 no.2 s.67
    • /
    • pp.128-138
    • /
    • 2007
  • At low in-situ stress, the continuity and distribution of natural fractures in rock mass predominantly control the failure processes. However at high in-situ stress, the failure process are affected and eventually dominated by stress-induced fractures preferentially growing parallel to the excavation boundary. This fracturing is often observed in brittle type of failure such as slabbing or spatting. Recent studies on the stress- or excavation-induced damage of rock revealed its importance especially in a highly stressed regime. In order to evaluate the brittle failure around a deep underground opening, physical model experiments were carried out. For the experiments a new tue triaxial testing system was made. According to visual observation and acoustic emission detection, brittle failure grades were classified under three categories. The test results indicate that where higher horizontal stress, acting perpendicular $(S_{H2})$ and parallel $(S_{H1})$ to the axis of the tunnel respectively, were applied, the failure grade at a constant vertical stress level (Sy) was lowered. The failure initiation stress was also increased with the increasing $S_{H1}\;and\;S_{H2}$. From the multi-variable regression on failure initiation stress and true triaxial stress conditions, $f(S_v,\;S_{H1},\;S_{H2})$ was proposed.

Intra-abdominal Retained Surgical Gauze in Two Dogs (개의 복강내 잔존 수술용 거즈 2예)

  • Choi, Ho-Jung;Lee, Ki-Ja;O, I-Se;Lee, Jae-Yeon;Jee, Hyun-Chul;Park, Seong-Jun;Jeong, Seong-Mok;Lee, Young-Won
    • Journal of Veterinary Clinics
    • /
    • v.24 no.2
    • /
    • pp.238-243
    • /
    • 2007
  • This report describes the retained surgical gauze in two dogs that had ovariohysterectomy previously. The elapsed time between surgery and diagnosis of retained surgical gauze in two dogs was 30 and 16 months, respectively. Radiographic signs included localized abdominal mass (case 1, 2) and soft tissue swelling (case 2). Retained surgical gauze was imaged by survey radiography, ultrasonography and computed tomography (CT). Ultrasonography revealed a hypoechoic mass with irregular hyperechoic center in case 1, and hypoechoic mass with oval hyperechoic center and acoustic shadowing in case 2. In CT examination of case 2, hyperdense mass with a thick peripheral rim enhancing in contrast study was shown. Cytologic examination of both cases revealed abscess and granuloma respectively. The lesions were surgically removed. The possibility of retained surgical gauze should be considered in animals with a history of previous surgery with abnormal mass.

Surgical Management of Urethral Plugs in a Male Shih-Tzu Dog (수컷 시츄견에서 발생한 유레쓰랄 플러그의 수술적 관리)

  • Hong, Su-Bin;Kim, Min-Kyung;Kim, Tae-Hwan;Kim, Keun-Yung;Kim, Hyo-Yeon;Lee, Jae-Hoon
    • Journal of Veterinary Clinics
    • /
    • v.32 no.6
    • /
    • pp.519-522
    • /
    • 2015
  • A 6-year-old castrated male Shih-Tzu was admitted to the Gyeongsang Animal Medical Center with hematuria and vomiting. Serum chemistry indicated increases in blood urea nitrogen and creatinine values. Radiography showed radiopaque materials attached to the ventralis of the inner bladder wall. Penile urethra also was filled with radiopaque materials. Ultrasonography revealed bilateral perineal effusion in the kidney, thinned bladder wall, and materials with acoustic shadowing at the caudal extremity of the os penis. Because urination was not identified by urinary obstruction, cystocentesis was performed. Hematuria was diagnosed by urinalysis, but clear crystals were not identified. Owing to failure of securing patency to the bladder using retrohydropropulsion, cystotomy and urethrotomy with retrohydropropulsion were performed. In this report, we describe the clinical and radiographic findings of urethral plugs in a male Shih-Tzu dog, wherein the urethral plugs were treated successfully with hydropropulsion, cystotomy, and urethrotomy. It provides an option for the treatment of urethral plugs in a dog.

Analysis on Correlation between AE Parameters and Stress Intensity Factor using Principal Component Regression and Artificial Neural Network (주성분 회귀분석 및 인공신경망을 이용한 AE변수와 응력확대계수와의 상관관계 해석)

  • Kim, Ki-Bok;Yoon, Dong-Jin;Jeong, Jung-Chae;Park, Phi-Iip;Lee, Seung-Seok
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.21 no.1
    • /
    • pp.80-90
    • /
    • 2001
  • The aim of this study is to develop the methodology which enables to identify the mechanical properties of element such as stress intensity factor by using the AE parameters. Considering the multivariate and nonlinear properties of AE parameters such as ringdown count, rise time, energy, event duration and peak amplitude from fatigue cracks of machine element the principal component regression(PCR) and artificial neural network(ANN) models for the estimation of stress intensity factor were developed and validated. The AE parameters were found to be very significant to estimate the stress intensity factor. Since the statistical values including correlation coefficients, standard mr of calibration, standard error of prediction and bias were stable, the PCR and ANN models for stress intensity factor were very robust. The performance of ANN model for unknown data of stress intensity factor was better than that of PCR model.

  • PDF

Development of an EMAT System for Detecting flaws in Pipeline (배관결함 검출을 위한 EMAT 시스템 개발)

  • Ahn, Bong-Young;Kim, Young-Joo;Kim, Young-Gil;Lee, Seung-Seok
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.1
    • /
    • pp.15-21
    • /
    • 2004
  • It is possible to detect flaws in pipelines without interruption using all EMAT transducer because it is a non-contact transducer which can transmit ultrasonic waves into specimens without couplant. And it ran easily generate guided waves desired in each specific problem by altering the design of coil and magnet. In the present work, EMAT systems have been fabricated to generate surface waves, and selectively the plate wave of $A_1\;or\;S_1$ mode. The surface wave of 1.5MHz showed a good signal-to-noise ratio without distortion in its propagation along a pipeline, while the $S_1$ mode of 800kHz and the $A_1$ mode of 940kHz were distorted according to their dispersive properties. The wider the excitation pulse becomes, the better the mode selectivity of the plate waves becomes. A pipe of 256mm inner diameter and 5.5m thickness with 5 flaws was used for comparing the flaw detectability among the modes under consideration.