• 제목/요약/키워드: acidic wastewater

검색결과 83건 처리시간 0.025초

산화 전처리가 고강도 질소폐수의 막증류 공정에 미치는 영향 (The Effect of Acidification on Membrane Distillation Process for Strong Nitrogenous Wastewater)

  • ;정다운;배효관
    • 한국물환경학회지
    • /
    • 제36권2호
    • /
    • pp.137-147
    • /
    • 2020
  • A direct contact membrane distillation (DCMD) was applied to treat strong nitrogenous wastewater of anaerobic digestion supernatant (ADS) and human urine (HU). The ammonia transfer was evaluated in terms of specific ammonia transfer (SAT) value, which is the ratio of total ammoniacal nitrogen divided by the amount of water transferred. The acidification resulted in low SAT values and high quality of produced water. The ammonia transfer control in the acidic condition was stronger for HU than ADS due to higher alkalinity (pH 8.8) and ammonia concentration (5700 mg-N/L) of HU. Acidified HU at pH 4 exhibited a SAT value of 1.64 × 10-5, which was significantly smaller than the SAT value of 3.00 × 10-3 for the original HU. The low pH enhanced the water flux for ADS, but HU showed a steep decrease in water flux due to enhanced fouling. It was considered that the fouling intensity in acidic conditions depends on the characteristics of the wastewater source. The major foulants on the MD membrane were NaCl, CaCO3 and CuSO4 as recognized by the SEM-EDS. Acidified ADS and HU at pH 4 showed relatively high N content of 8.18 % and 28.03 %, respectively, as organic fouling.

정수 및 폐수처리에서 오존 미세기포와 초미세기포 기술의 적용 : 리뷰 (Applications of Ozone Micro- and Nanobubble Technologies in Water and Wastewater Treatment: Review)

  • 테킬 안디넷;김일호;이재엽
    • 상하수도학회지
    • /
    • 제31권6호
    • /
    • pp.481-490
    • /
    • 2017
  • Water and wastewater treatment has always been a challenging task due to the continuous increase in amount and the change in characteristics of the poorly biodegradable and highly colored organic matters, as well as harmful micro-organisms. Advanced techniques are therefore required to successfully remove these pollutants from water before reuse or discharge to receiving water bodies. Application of ozone, which is a powerful oxidant and disinfectant, alone or as part of advanced oxidation process depends on the complex kinetic reactions and the mass transfer of ozone involved. Micro- and nano bubbling considerably improves gas dissolution compared to conventional bubbles and hence mass transfer. It can also intensify generation of hydroxyl radical due to collapse of the bubbles, which in turn facilitates oxidation reaction under both alkaline as well as acidic conditions. This review gives the overview of application of micro- and nano bubble ozonation for purification of water and wastewater. The drawbacks of previously considered techniques and the application of the hydrodynamic ozonation to synthetic aqueous solutions and various industrial wastewaters are systematically reviewed.

A Microbial Consortium for the Bioremediation of Sulfate-Rich Wastewater Originating from an Edible Oil Industry

  • Pascual, Javier;Rodriguez, Alejandro;Delgado, Clara Elena;Rizo-Patron, Alejandra;Porcar, Manuel;Vilanova, Cristina
    • 한국미생물·생명공학회지
    • /
    • 제50권1호
    • /
    • pp.110-121
    • /
    • 2022
  • The effluents from industries processing vegetable oils are extremely rich in sulfates, often exceeding the maximum concentration allowed to release them to the environment. Biological sulfate reduction is a promising alternative for the removal of sulfates in this type of wastewater, which has other particularities such as an acidic pH. The ability to reduce sulfates has been widely described for a particular bacterial group (SRB: sulfate-reducing bacteria), although the reports describing its application for the treatment of sulfate-rich industrial wastewaters are scarce. In this work, we describe the use of a natural SRB-based consortium able to remove above 30% of sulfates in the wastewater from one of the largest edible oil industries in Peru. Metataxonomic analysis was used to analyse the interdependencies established between SRB and the native microbiota present in the wastewater samples, and the performance of the consortium was quantified for different sulfate concentrations in laboratory-scale reactors. Our results pave the way towards the use of this consortium as a low-cost, sustainable alternative for the treatment of larger volumes of wastewater coming from this type of industries.

저농도(低濃度) 페놀의 활성탄(活性炭)에 대한 흡착특성(吸着特性)에 관(關)한 연구(硏究) (A Study on the Adsorption Characteristic of Low Concentration Phenol by Activated Carbon)

  • 권대영;박중현
    • 상하수도학회지
    • /
    • 제8권1호
    • /
    • pp.34-43
    • /
    • 1994
  • It is well known that the adsorption character of activated carbon is dependent on the specific surface area and pore volume, but the relationship between the surface-chemical structure and the adsorption character has not been studied very often. The purpose of this study is to investigate the effect of the acidic surface functional groups of activated carbon and the adsorption characteristics of low concentration phenol. So three types of activated carbons and four different treatments were introduced to this isotherm experiment. These treatments were nontreatment, 1N $HNO_3$ treatment, 6N $HNO_3$ treatment, $H_2O_2$ treatment. The conclusions of this study are as followings. If the initial concentration of phenol is high as 5mg/l, the adsorption is dependent on the specific surface area. If the initial concentration of phenol is low as $100{\mu}g/l$, the adsorption is dependent on the average pore volume. The acidic surface functional groups prevent the adsorption of phenol molecules to activated carbon. And the adsorbed amount decreases more for $HNO_3$ treatment than for $H_2O_2$ treatment and more for concentrated $HNO_3$ treatment than for dilute $HNO_3$ treatment.

  • PDF

PAC 전처리 시 수소이온 농도에 따라 발생 가능한 알루미늄 종에 의한 나노여과막 성능 연구 (Effects of polymeric Al and hydrolysis products of PAC at different pH on performance of nanofiltration with PAC coagulation pretreatment)

  • 최양훈;권지향
    • 상하수도학회지
    • /
    • 제24권1호
    • /
    • pp.15-24
    • /
    • 2010
  • Coagulation can be used for pretreatment of NF membrane filtration. Foulants such as organic matter and particulate can be removed effectively with the process while high flux recovery is maintained. Recently various types of polyaluminium coagulants including polyaluminium chloride(PAC) are commercially available for water treatment. This study examines effects of polymeric Al and hydrolysis products of PAC on nanofiltration membrane performance. Dominant hydrolysis products were polymeric Al, $Al(OH)_3$, and ${Al(OH)_4}^{-1}$ at acidic, neutral, and alkaline pH conditions, respectively. Under acidic pH condition, flux decline was increased with increasing PAC concentrations, possibly due to polymeric Al adsorption on membrane pore and/or surfaces. For neutral and alkaline pH conditions, little flux decline was observed with increasing PAC concentrations except the highest ${Al(OH)_4}^{-1}$ concentration, with which rapid flux decline was shown. Removal of ionic matters was also varied with pH conditions in this study. Especially, conductivity removal was substantially low and $Ca^{2+}$ concentration in the permeate was quite high at neutral pH condition.

효소에 의한 초지용 펠트의 세척효과 (Cleaning Effect of Papermaking Felt with Enzymes)

  • 윤병태;김성보;엄태진;최명재
    • 펄프종이기술
    • /
    • 제37권3호
    • /
    • pp.17-22
    • /
    • 2005
  • The cleaning efficiency of papermaking felt which is contaminated with fiber fines and various micro-materials was investigated and compared between the application of enzyme and commercial detergent. It was found that the cleaning efficiency by the treatment of acidic-based detergent was more efficient than that of alkaline-based one in the conventional commercial detergent. it was also observed that the treatment design of first acidic-based detergent treatment to second alkaline-based detergent procedure was better in the cleaning efficiency, compared to alkaline based-to-acidic based one. The cleaning property of felt with enzyme was resulted in good cleaning efficiency, without any addition of surfactant. Especially, the enzyme treatment under alkaline condition (pH 10) showed a better cleaning result than that under acidic condition(pH 5). The addition of nonionic surfactant to the enzyme increased the cleaning efficiency of felt and decreased the cationic demand of wastewater. These results showed more favour than the application of conventional commercial detergent.

굴껍질을 이용한 도금폐수의 중화 및 중금속 이온 제거 (Neutralization and removal of heavy metal ions in Plating wastewater utilizing Oyster Shells)

  • 성낙창;김은호;김정권;김형석
    • 한국환경보건학회지
    • /
    • 제22권3호
    • /
    • pp.81-87
    • /
    • 1996
  • The purpose of this research is to examine the utilization of oyster shells for neutralization and removal of heavy metal ions in plating wastewater, because oyster shells have been known to be very porous, to have high specific surface area and to have alkaline minerals such as calcium and magnesium. The results obtianed from this research showed that oyster shells had a buffer capacity to neutralize an acidic.alkali system in plating wastewater. Generally, it could be showed that the removal efficiencies of heavy metal ions were very influenced by reaction times and oyster shell dosages. In point of ocean waste, if oyster shells substituted for a valuable adsorbent such as actviated carbon, they could look forward to an expected economical effect.

  • PDF

Evaluation of dynamic behavior of coagulation-flocculation using hydrous ferric oxide for removal of radioactive nuclides in wastewater

  • Kim, Kwang-Wook;Shon, Woo-Jung;Oh, Maeng-Kyo;Yang, Dasom;Foster, Richard I.;Lee, Keun-Young
    • Nuclear Engineering and Technology
    • /
    • 제51권3호
    • /
    • pp.738-745
    • /
    • 2019
  • Coprecipitation using hydrous ferric oxide (HFO) has been effectively used for the removal of radionuclides from radioactive wastewater. This work studied the dynamic behavior of HFO floc formation during the neutralization of acidic ferric iron in the presence of several radionuclides by using a photometric dispersion analyzer (PDA). Then the coagulation-flocculation system using HFO-anionic poly acrylamide (PAM) composite floc system was evaluated and compared in seawater and distilled water to find the effective condition to remove the target nuclides (Co-60, Mn-54, Sb-125, and Ru-106) present in wastewater generated in the severe accident of nuclear power plant like Fukushima Daiichi case. A ferric iron dosage of 10 ppm for the formation of HFO was suitable in terms of fast formation of HFO flocs without induction time, and maximum total removal yield of radioactivity from the wastewater. The settling time of HFO flocs was reduced by changing them to HFO-PAM composite floc. The optimal dosage of anionic PAM for HFO-anionic PAM floc system was approximately 1-10 ppm. The total removal yield of Mn-54, Co-60, Sb-125, Ru-106 radionuclides by the HFO-anionic PAM coagulation-flocculation system was higher in distilled water than in seawater and was more than 99%.

포화컬럼실험에서 산화공정을 적용한 내분비계 장애물질의 제거 및 은나노물질의 거동 연구 (Mobility of silver nanoparticles (AgNPs) and oxidative degradation of endocrine disrupting chemicals by saturated column experiments)

  • 김예진;허지용
    • 상하수도학회지
    • /
    • 제32권6호
    • /
    • pp.499-505
    • /
    • 2018
  • We applied column experiments to investigate the environmental fate and transport of silver nanoparticles(AgNPs) in fully saturated conditions of porous media. These column experiments were performed to emphasize oxidation method with $H_2O_2$ concentration and acidic conditions. The mobility of AgNPs was decreased with the increasing ionic strength that the surface charge of AgNPs(zeta potential) was neutralized with the presence of positive ions of $Na^+$. Additionally, it was also affected due to that not only more increased aggregated size of AgNPs and surface charge of quartz sand. The decreased breakthrough curves(BTCs) of bisphenol-A(BPA) and $17{\alpha}$-ethynylestradiol(EE2) were removed approximately 35.3 and 40%. This is due to that endocrine disrupting chemicals(EDCs) were removed with the release of $OH{\cdot}$ radicals by the fenton-like mechanisms from acidic and fenton-like reagent presenting. This results considered that higher input AgNPs with acidic conditions is proved to realistic in-situ oxidation method. Overall, it should be emphasized that a set of column experiments employed with adjusting pH and $H_2O_2$ concentration in proved to be effective method having potential ability of in-situ degradation for removing organic contaminants such as BPA and EE2.

도금폐수처리를 위한 입상활성탄 유동 메디아 적용 유동상 멤브레인 여과기술의 적용가능성 평가에 관한 연구 (Study on Feasibility of Fluidized Bed Membrane Reactor with Granular Activated Carbon Particles as Fluidized Media to Treat Metal-plating Wastewater)

  • 장수민;권대은;김정환
    • 멤브레인
    • /
    • 제28권4호
    • /
    • pp.252-259
    • /
    • 2018
  • 실 산성 도금폐수를 입상활성탄(GAC)이 유동메디아로 첨가된 유동상 멤브레인 반응기를 이용하여 처리하였다. GAC 유동조건에서 적용 투과플럭스에 대해 시간에 따른 흡입압의 증가는 관찰되지 않았다. 폐수의 중성 pH에서 파울링 속도는 산성 조건에 비해 GAC 유동조건에서 크게 감소하였다. 해당 폐수의 용액 pH 증가는 입자크기의 증가를 가져왔고 이는 멤브레인 표면에서 상대적으로 성긴 구조의 케이크층 형성을 야기시켰다. 유동상 멤브레인 반응기에서 GAC 유동 하에 95%이상의 COD 제거율이 관찰되었으며 총부유물질은 거의 완벽하게 제거되었다. 실 도금폐수의 pH에서, 유동상 멤브레인 반응기의 구리 및 크롬의 제거는 거의 관찰 되지 않았다. 그러나 pH를 중성으로 증가 시켰을 시 구리와 크롬의 제거율은 각각 99%와 94%까지 증가를 하였다. 적용해 준 pH에 상관 없이, 시안의 경우 95% 이상의 제거율을 달성하였다. 이는 유기물과 시안 착물 형성으로 인해 유동상 멤브레인 반응기 내 GAC의 강한 흡착으로 제거된 것으로 사료된다.