• 제목/요약/키워드: acid corrosion

검색결과 498건 처리시간 0.022초

Surface Treatment Technology for Metal Corrosion Layer Focusing on Copper Alloy

  • Yang, Eun-Hee;Han, Won-Sik;Choi, Kwang-Sun;Lee, Young-Hoon;Ham, Chul-Hee;Hong, Tae-Kee
    • Journal of the Korean Applied Science and Technology
    • /
    • 제31권2호
    • /
    • pp.176-182
    • /
    • 2014
  • Using alkali treatment solution, neutrality treatment solution and acid treatment solution, the surface corrosion layer of copper plates and bronze plates that have been artificially corroded using HCl, $H_2SO_4$ and $HNO_3$ solutions were removed. In the case of alkali treatment solution, only air oxidation in the form of black tenorite and white cuproous chloride remained without being removed. In the case of using a neutrality treatment solution, a anhydrous type layer of reddish brown cupric chloride remained without being removed, together with this black and white corrosion substance. In the case of using an acid treatment solution, this red corrosion substance also remained, but all of the oxide was removed on the surface of the specimen that was treated by alternatively using alkali treatment solution and acid treatment solution. In the case of this treatment solution with the order of alkali-acid, oxidation no longer proceeded only through the distilled water cleaning process after treatment, thereby showing that oxidation from the cleaning solution no longer proceeded.

Monitoring of Degradation Process of Commercial ME Tapes under High Humidity Environment by AC Impedance Techniques

  • Take, Seisho;Shimanuki, Akiko;Itoi, Yasuhiko;Okuyama, Masaru
    • Corrosion Science and Technology
    • /
    • 제3권5호
    • /
    • pp.194-197
    • /
    • 2004
  • The corrosion resistance of several kind of ME (Metal Evaporated) tape has been investigated both in mild sulfuric acid solution and NaCl solution by electrochemical impedance spectroscopy. It was found that the degradation of ME tapes was accelerated with increasing the concentration of sulfuric acid. There was no significant change in corrosion resistance when the concentration of NaCl was under 3.5 wt%. However, the impedance value decreased when the concentration of NaCl was up to 10 wt%. The degradation of backside of ME tapes was also investigated by AC impedance measurements. The results showed that the impedance behavior of backside plastic film changed with the concentration of sulfuric acid even at the beginning of immersion, implying the changing of the permeability for the backside of ME tapes. It was also found that the corrosion resistance of DVC (Digital Video Cassette) ME tape was better that that of Hi-8mm ME tapes in sulfuric acid solutions. Also, the backside of DVC ME tape showed better water resistance than that of Hi8 ME tapes.

Analysis of dew point and corrosion resistance for power plant economizer tube with exhaust gas temperature and sulfuric acid concentration (발전소 절탄기 튜브의 배기가스 온도와 황산 농도에 따른 노점 및 내식성 분석)

  • Choi, Jae-Hoon;Lee, Seung-Jun
    • Journal of the Korean institute of surface engineering
    • /
    • 제55권6호
    • /
    • pp.433-440
    • /
    • 2022
  • Environmental pollution caused by power plant exhaust gas is highlighted and eco-friendly regulations are being strengthened. However, due to the abundant reserves and low prices of coal, still the most used for power generation in the world. Therefore, flexible operation of coal-fired power plants to reduce emissions has become an inevitable option. However, lowering the output increases the possibility of acid dew point corrosion as the exhaust gas temperature decreases. The dew point corrosion occurs when condensable gases such as SO3, HCl, NO2 and H2O cools below the saturation temperature. SO3 is already well known to cause severe low- temperature corrosion in coal-fired power plants. Therefore, this study aims to prevent damage that may occur during operation by analyzing the dew point and corrosion resistance with exhaust gas temperature and sulfuric acid concentration of the power plant economizer tube.

Effect of Acid Fog on Rust Formation and Fatigue Strength of Weathering Steel (산성안개가 내후성강재의 녹형성 및 피로강도에 미치는 영향)

  • Kim, Min-Gun;Ku, Eun-hoi
    • Journal of Industrial Technology
    • /
    • 제22권B호
    • /
    • pp.13-20
    • /
    • 2002
  • The purpose of this study is to investigate the effect of acid fog on the rust formation behavior of weathering steel (SMA50) which is used in uncoated bridges. Weathering steel didn't form the passive film under the environment of acid fog(pH5,6), whereas the environment of distilled water formed the protective oxide film. Therefore, the construction of weathering steel under the environment extremely exposed to SOx and NOx which are the main compositions of acid fog is not adequate. Fatigue limits of weathering steel under acid fog environment are remarkably decreased as compared with environment of distilled water. The corrosive constituents in acid fog has piled up the corrosion products on specimen surface and generated the corrosion pits. Because of the high stress concentration arising at this corrosion pit, relatively low fatigue limits were obtained for acid fog specimens.

  • PDF

Effect of Acid Fog on Rust Formation and Fatigue Behavior of Weathering Steel Used in Un-Coated Bridge (무도장 교량에 사용되는 내후성강재의 부식 및 피로거동에 미치는 산성안개의 영향)

  • Kim, Min-Gun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • 제32권1호
    • /
    • pp.13-20
    • /
    • 2008
  • The purpose of this study is to investigate the effect of acid fog on the rust formation behavior of weathering steel (SMA50) which is used in un-coated bridges. Weathering steel didn't form the passive film under the environment of acid fog(pH5,6), whereas the environment of distilled water formed the protective oxide film. Therefore, the construction of weathering steel under the environment extremely exposed to SOx and NOx which are the main compositions of acid fog is not adequate. Fatigue limits of weathering steel under acid fog environment are remarkably decreased as compared with environment of distilled water. The corrosive constituents in acid fog has piled up the corrosion products on specimen surface and generated the corrosion pits. Because of the high stress concentration arising at this corrosion pit, relatively low fatigue limits were obtained for acid fog specimens.

The Effect of Imidazole and 2-Methyl Imidazole on the Corrosion of Mild Steel in Phosphoric Acid Solution

  • Chandrasekara, V.;Kannan, K.;Natesan, M.
    • Corrosion Science and Technology
    • /
    • 제4권5호
    • /
    • pp.191-200
    • /
    • 2005
  • Two azole compounds viz., Imidazole (IM) and 2-Methylimidazole (2-MIM) were studied to investigate their inhibiting action on corrosion of mild steel in phosphoric acid ($H_3PO_4$) solution by mass loss and polarization techniques at 302K-333K. It has been found that the inhibition efficiency of the all inhibitors increased with increase in inhibitor concentration and decreases with increasing temperature and also with increase in acid concentrations. The inhibition efficiency of these compounds showed very good inhibition efficiency. At 0.5% of IM and 2-MIM in 1N and 5N phosphoric acid solution at 302K to 333K for 5 hours immersion period, the inhibition efficiency of 2-Methylimidazole found to be higher than Imidazole. The adsorption of these compounds on the mild steel surface from the acids has been found to obey Tempkin's adsorption isotherm. The values of activation energy ($E{\alpha}$) and free energy of adsorption (${\Delta}G{\alpha}ds$) were also calculated. The plots of log $W_f$ against time (days) at 302K give straight line which suggested that it obeys first order kinetics and also calculate the rate constant k and half life time $t_{1/2}$. Surface was analyzed by SEM and FITR spectroscopy.

Film Formation in $CO_2$ Corrosion with the Presence of Acetic: An Initial Study

  • Ismail, Mokhtar Che;Mohd, Muhammad Azmi;Turgoose, Stephen
    • Corrosion Science and Technology
    • /
    • 제7권1호
    • /
    • pp.22-26
    • /
    • 2008
  • Formation of protective iron carbonate films in $CO_2$ corrosion can reduce corrosion rate substantially and the effects have been incorporated in various prediction models. The $CO_2$ corrosion with the presence of free acetic acid is known to increase corrosion rate below scaling temperature. The possible interaction between the formation of iron acetate and iron carbonate films can affect the protectiveness of the film. The study is done using 3% NaCl solution under stagnant $CO_2$ -saturated condition at the scaling temperatures at various pH values and HAC concentrations. The result show that the presence of HAc does not affect the formation of protective iron carbonate film but delays the attainment of protective iron carbonate due to a possibility of solubilising of ferrous ions and thinning of the films.

The Aqueous Corrosion Characteristics of Catenary Materials of Electric Railway System (전차선로 가선재의 수용액 부식 특성)

  • 김용기;장세기;조성일;이재봉
    • Journal of the Korean Society for Railway
    • /
    • 제4권2호
    • /
    • pp.62-70
    • /
    • 2001
  • Pure copper, Cu-1.1wt%Cd and ACSR(Aluminum Conductor Steel Reinforced) have been used as catenary materials of the electric railway system. Since these materials may be exposed to the corrosive environments like polluted air, acid rain and sea water, it is important to investigate the corrosion rates in various corrosive environments. The aqueous corrosion characteristics of catenary materials in aerated acid, neutral and alkali solutions were studied by using immersion corrosion tests, electrochemical measurements and analytical techniques. In order to examine corrosion characteristics according to the dissolved oxygen content, pH, chloride ion concentration ion, and the addition of Cd to Cu, a series of tests such as potentiodynamic polarization, a.c impedance spectroscopy and galvanic corrosion tests were carried out with these materials. Results showed that the addition of Cd to Cu and chloride ion in the solution have an adverse effects on the resistance to corrosion. Additionally, Galvanic currents between Al and steel wires of ACSR were confirmed by using ZRA(zero resistance ammeter) method.

  • PDF

Application of corrosion inhibitors to water distribution systems

  • Park, Yong-Il;Woo, Dal-Sik;Cho, Young-Tai;Jo, Kwan-Hyung;Nam, Sang-Ho
    • Journal of Environmental Science International
    • /
    • 제11권5호
    • /
    • pp.411-418
    • /
    • 2002
  • The current study evaluated the disinfection efficiency of free chlorine and chloramine for microorganisms on various pipe materials, such as copper, galvanized steel, carbon steel, and stainless steel. In addition, the effect of internal pipe corrosion and corrosion inhibitors on the bactericidal efficiency was evaluated using a simulated loop. For disinfection with a phosphate corrosion inhibitor, chloramination was found to be more effective than chlorination due to its persistence. Free chlorine disinfection was optimized with a high phosphoric acid concentration, while chloramine disinfection was optimized with a high phosphoric acid or low polyphosphate concentration. In simulated copper and galvanized steel loop tests, chloramination with phosphoric acid was demonstrated to be more effective.

Corrosion Characterestic of Rolling Stock Structural Steel by Environmental Degradation (환경열화에 의한 철도차량 구조용강의 부식 특성)

  • Kim Yong-Ki;Chang Se-Ky;Oh Chang-Rok;Goo Byeong-Chun
    • Proceedings of the KSR Conference
    • /
    • 한국철도학회 2004년도 추계학술대회 논문집
    • /
    • pp.680-685
    • /
    • 2004
  • The effects of acid rain and salt content on corrosion behavior were investigated with rolling stock structural steels be caused by environmental. Since these materials are exposed to the corrosive environments like polluted air, acid rain and sea water, it is important to investigate corrosion behaviour in various corrosive environments. The aqueous corrosion of the characteristic materials in aerated acid rain and neutral solution were studied by using immersion tests, electrochemical measurements and analytical techniques. In order to examine corrosion characteristic, structural steels were electrochemically evaluated with respect to the dissolved oxygen content, pH, chloride ion concentration.

  • PDF