• Title/Summary/Keyword: accident-free

Search Result 147, Processing Time 0.023 seconds

A Optimization of Fire Safety Design in Multiplex Cinema Theater (국내 복합상영관 시설의 방재대책에 관한 연구)

  • 허준호;윤명오
    • Fire Science and Engineering
    • /
    • v.16 no.2
    • /
    • pp.43-50
    • /
    • 2002
  • 21C, Multiplex Cinema Theater is made from movie industry developed and become a place where we can spend our free time and consuming. But, theater users, who are many and unspecified persons, are short of information on the Multiplex Cinema Theater, so that they may be injured or killed at the occurrence of fire accident. Particularly, Multiplex Cinema Theater is a place that underground space or top floor in highrise building had many people in theaters. However, this problem is difficult to solve that to protect human being and properties at the occurrence of fire accident in the Multiplex Cinema Theater, In order to overcome such problems, Multiplex Cinema Theater need fire protection solutions facilities concerning particulars to pay attention to the safety on a fire and evacuation. This study analysed Multiplex Cinema Theater concept and computer simulation for risk point.

A Study on the Performance and Exhaust Emissions Characteristics of LPG Engine using LPG Fuel with New Sulfur Free Odorant (새로운 비황분계 부취제 혼합 LPG 연료의 엔진성능과 배출가스 특성에 관한 연구)

  • Kim, Jae-Kon;Yim, Eui Soon;Min, Kyong-Il;Jung, Choong-Sub
    • Journal of Energy Engineering
    • /
    • v.23 no.3
    • /
    • pp.88-95
    • /
    • 2014
  • In general, odorants are added to fuel gases, such as LPG, LNG and city gas, to prevent gas poisoning, ignition, explosion, or other accident caused by fuel gases, and to enable immediate and easy detection of fuel-gas leakage by emitting an offensive smell. This study describes a study on the performance and exhaust emissions (CO, THC, $CO_2$, $NO_x$, $SO_2$) characteristics of liquefied petroleum gas (LPG) engine using LPG fuel with new sulfur free odorant (K-Petro S-Free). New sulfur free odorant (40 mg/kg) was added to 2 type LPG fuels for summer, and winter and it was used in performance and exhaust emissions, compare to LPG fuel with sulfur containing odorant (EM, ethyl mercaptan). Engine performance using LPG with sulfur free odorant was similar to LPG with sulfur-containing odorant. Exhaust emissions (CO, THC, $CO_2$, $NO_x$) of LPG with sulfur free odorant were also similar characteristics, compare with sulfur containing odorant. Especially, $SO_2$ emission using LPG with K-Petro S-Free odorant was more reduced 83 % than LPG with sulfur containing odorant(EM) at 2000 rpm.

Reconstruction of Greater Trochanteric defect using Lumbar Artery Perforator Free Flap - A Case Report - (요추부 천공지 유리피판을 이용한 대전자부 결손의 재건 - 증례보고 -)

  • Heo, Chan-Yeong;Baek, Rong-Min;Minn, Kyung-Won;Eun, Seok-Chan
    • Archives of Reconstructive Microsurgery
    • /
    • v.16 no.1
    • /
    • pp.48-51
    • /
    • 2007
  • There could be several methods for trochanteric reconstruction including local flap, pedicled perforator flaps, free flap, etc. We performed greater trochanteric reconstruction with lumbar artery perforator free flap in some aberrant method. So we report this experience with review of literatures. A 42-year-old man visited our hospital with a large soft tissue defect in his left greater trochanteric area by traffic accident. The patient had wide skin and soft tissue defect combined with open femur fracture. During one month period of admission, he underwent femur open reduction and wound debridement four times. After that we planned thoracodorsal perforator free flap reconstruction. The flap was outlined as large as $20{\times}15\;cm$ and elevated in a suprafascial plane from the lateral border. During intramuscular perforator dissection, we found that two 1.5 mm diametered perforator vessels coursed inferomedially toward second lumbar region. Finally the flap became lumbar artery perforator flap based on second lumbar artery perforator as a main pedicle. After flap transfer, the perforator vessels were connected with inferior gluteal artery and vein microsurgically. The operation was successful without uneventful course. We found no significant postoperative complication and donor site morbidity during six months follow up periods. Lumbar artery perforator flap could be an alternative procedure for thoracodorsal perforator flap in some patients with anatomic variant features.

  • PDF

A Study on the Stability of a Low Freeboard Coastwise Tanker Capsized in Turning (1) (선회중 전복한 저건현 내항 탱커의 복원성에 관한 연구 (1))

  • Kong, Gil-Young;Kim, Chol-Seong;Sadakane, Hiroyuki
    • Journal of Navigation and Port Research
    • /
    • v.26 no.1
    • /
    • pp.1-7
    • /
    • 2002
  • A coastwise chemical tanker sailing at full speed has capsized in calm water and while turing. We investigate reasons of the accident and demonstrate that a proper correction for the free surface effect of the liquid cargo has not been practiced in the initial design stage and that the bow-sinkage induced in sailing has weakened the form stability of the ship. It is also shown that the liquid cargo shift occurring in turning generated a significant outward heel moment.

Fingernail electron paramagnetic resonance dosimetry protocol for localized hand exposure accident

  • Jae Seok Kim;Byeong Ryong Park;Minsu Cho;Won Il Jang;Yong Kyun Kim
    • Nuclear Engineering and Technology
    • /
    • v.55 no.1
    • /
    • pp.270-277
    • /
    • 2023
  • Exposure to ionizing radiation induces free radicals in human nails. These free radicals generate a radiation-induced signal (RIS) in electron paramagnetic resonance (EPR) spectroscopy. Compared with the RIS of tooth enamel samples, that in human nails is more affected by moisture and heat, but has the advantages of being sensitive to radiation and easy to collect. The fingernail as a biological sample is applicable in retrospective dosimetry in cases of localized hand exposure accidents. In this study, the dosimetric characteristics of fingernails were analyzed in fingernail clippings collected from Korean donors. The dose response, fading of radiation-induced and mechanically induced signals, treatment method for evaluation of background signal, minimum detectable dose, and minimum detectable mass were investigated to propose a fingernail-EPR dosimetry protocol. In addition, to validate the practicality of the protocol, blind and field experiments were performed in the laboratory and a non-destructive testing facility. The relative biases in the dose assessment result of the blind and field experiments were 8.43% and 21.68% on average between the reference and reconstructed doses. The results of this study suggest that fingernail-EPR dosimetry can be a useful method for the application of retrospective dosimetry in cases of radiological accidents.

Young Children's Free Choice Activities and a Play Rule Restricting the Number of Players (유아의 자유선택활동과 놀이 인원수 제한규칙)

  • Lee, Eu Jung;Won, Kye Son
    • Korean Journal of Childcare and Education
    • /
    • v.12 no.1
    • /
    • pp.57-81
    • /
    • 2016
  • The purpose of this study was to find out the feature of children's play according to a player number restriction rule in the free choice activities. And it is expected that the result of this study will contribute to improving the management of free choice activities. The participants of this study were a homeroom teacher, professor as a co-researcher and 25 4-year-old children of a private kindergarten. The data were collected by observation, children interview and reflective journal of the teacher from July to October in 2014. The results indicated that the children were stressed out with using name cards for presenting center selection, showed overcompetitive behaviors, and frequently violated the rules. The researchers found that the restriction rule had some dysfunctions, which were interferences of moral development, social-emotional development, self-regulation development, preventing safety-accident and free choice behavior. The researcher as a teacher abandoned the player number restriction rule, and observed the children's play. As a result, children's self-regulation abilities on physical space, play and conflicts improved and the teacher changed her strategy when managing free choice activities. Based on the results, the needs of various restriction rules and appropriate methods for applying the rules in free choice activities were further discussed.

A Study on the Application of Sulfur-Free Odorant for LPG Fuel (LPG 연료용 비황분계 부취제의 적용성 연구)

  • Kim, Jae-Kon;Yim, Eui Soon;Jung, Choong-Sub
    • Journal of the Korean Institute of Gas
    • /
    • v.18 no.5
    • /
    • pp.52-59
    • /
    • 2014
  • In general, sulfur containing odorants are added to fuel gases, such as LPG, and city gas, to prevent gas poisoning, ignition, explosion, or other accident caused by fuel gases, and to enable immediate and easy detection of fuel-gas leakage by emitting an offensive smell. In this study, sulfur free odorant for low sulfur fuel and prevention of metal corrosion were developed to replace current sulfur containing odorant for gas fuel. They were selected from 12 odorant containing non-sulfur organic compounds and evaluated by odor olfactory method (odor quality, odor intensity). Finally, selected mixture odorants were methyl isovalerate, methyl acrylate, 2-ethyl-3-methyl pyrazine with blending ratio of 50% : 40% : 10%. Final Sulfur free odorant was added 40 wt ppm in LPG fuels and evaluated fuel quality characteristics, metal corrosion test and long term stability of LPG fuel. It were limit in current LPG fuel standard in fuel quality characteristics. Final Sulfur free odorant also had no influence on metal corrosion and long term stability test with 60 days by adding in LPG fuels. Finally, they were shown to be warning agent candidates to reduce sulfur content and metal corrosion for LPG fuel.

The Effect of Eccentric Isokinetic Exercise in Dislocation of the Tarsometatarsal (Lisfranc's) Joint: A Case Study (족근중족관절이 탈구된 환자에서 원심성 등속성운동의 효과: 사례연구)

  • Won, Jong-Im
    • Physical Therapy Korea
    • /
    • v.12 no.3
    • /
    • pp.94-100
    • /
    • 2005
  • Eccentric muscle contraction is more effective than concentric and iosmetric muscle contraction in increasing muscle strength. Also, eccentric or concentric-eccentric training has greater effective in neural activation and muscle hypertrophy than concentric training. In some study, eccentric exercises have been shown to reduce pain and improve function on Achilles tendinopathy. The purpose of this study was to evaluate the effect of eccentric isokinetic exercise in a patient with dislocation of the tarsometatarsal joint by traffic accident. After eccentric isokinetic training, peak torque, average work, and average power were increased. Also, the patient was fully weightbearing with a pain free normal gait thus making good recovery.

  • PDF

The Effects of Using Common Oversized Cookware for Portable Butane Gas Range (상용 과대 불판 사용이 이동식 부탄 연소기에 미치는 영향)

  • Kim, Sooik;Keum, Kuk Bin;Yu, Byeonghun;Lee, Seungro;Kim, Young-gu;Lee, Chang Eon
    • 한국연소학회:학술대회논문집
    • /
    • 2014.11a
    • /
    • pp.107-109
    • /
    • 2014
  • Through the economic development, people enjoying the camping and demand of camping goods are increasing since they have free time. So they use portable butane gas range outdoor. In addition to that, many restaurants that offer hotpot or meat in Korea use portable butane gas ranges for their convenience. But 19% of gas accidents are using portable butane gas range, 13.7% of them are using oversized cookware. Despite the high accident rate, there is no safety standards about portable butane gas range using oversized cookware. Therefore we conducted to measure temperature and pressure of portable butane gas ranges for reforming safety standards. As a result. we confirmed relation between bottom temperature of the portable butane gas barrel and pressure of the butane gas. Also we confirmed that portable butane gas ranges operate safely when bottom temperature of the portable butane gas barrel is bellow $50^{\circ}C$.

  • PDF

Dynamical Mechanism Analysis of An Industrial Two-step Folding Automatic Door (2단 접이식 산업용 자동문의 동역학적 메카니즘 해석)

  • Yun, Seong-Ho
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.28 no.7
    • /
    • pp.821-826
    • /
    • 2011
  • This paper deals with an analysis of dynamic mechanism for the industrial two-step folding automatic door. A nonlinear equation of motion was derived in terms of folding angle to estimate driving forces. Based on this dynamic behavior, time taken during the door's opening well as their velocities were controlled so that the operating conditions can be obtained for the purpose of design. The stiffness of twisting spring was also investigated when the automatic door closed, because a dangerous accident takes place from the door's free falling. The current research will be a very useful tool in the near future for the dynamic analysis for the multi-step folding automatic door.