• Title/Summary/Keyword: acceleration criteria

Search Result 200, Processing Time 0.024 seconds

Investigation for the Characters of Human Perception Level according to Acceleration Value Parameters (가속도 크기 변수에 따른 수직진동에 대한 인지수준 고찰)

  • Lee, MinJung;Han, SangWhan
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.24 no.9
    • /
    • pp.731-740
    • /
    • 2014
  • Occupants induced floor vertical vibrations may cause other occupant's annoyance and lead to social loss. To help control such floor vibrations, several criteria have been developed mostly based on human perception tests and floor vibration tests. Floor vibration is evaluated by comparison with criteria and vibration parameters of subject floor, such as frequency, damping ratio, acceleration value, vibration duration time and occurrence frequency. Three acceleration value parameters are used in criteria; peak acceleration, rms acceleration and VDV, when a floor vibration serviceability is evaluated. Meanwhile rms acceleration and peak acceleration are adopted as vibration limit value in criteria and researches of human perception for vibration. Occupants induced floor vibration is transient rather than steady state. However, rms acceleration is not reliable parameter for evaluating transient vibration. The objective of this study is to investigate the characters of human perception level according to acceleration value parameters for vibration induced by heel impacts and walking activities.

Review on Human Comfort Criteria in Tall Buildings (초고층건축물의 수평진동사용성 평가 기준의 재고)

  • Cho, Kang-Pyo;Jeong, Seung-Hwan;Cho, Gi-Sung;Km, Mu-Hwan
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2008.04a
    • /
    • pp.410-415
    • /
    • 2008
  • This paper presents review on human comfort criteria in major codes and standards for tall buildings. In general, human comfort criteria of tall buildings have been used by magnitude of wind-induced acceleration response. Two different indexes in determination of the magnitude have been used: the peak value which occurs during a period of time and the rms value averaged over this same period. These distinctive acceleration indexes are discussed in detail and each criterion is reviewed and compared. The distinctions arisen because of the different wave forms, or acceleration signatures are addressed. It is described that which index of acceleration should be adopted in establishment of Korean human comfort criteria. In addition, some arguments from a technical standpoint that favor the use of each index are presented.

  • PDF

Occupant comfort evaluation and wind-induced serviceability design optimization of tall buildings

  • Huang, M.F.;Chan, C.M.;Kwok, Kenny C.S.
    • Wind and Structures
    • /
    • v.14 no.6
    • /
    • pp.559-582
    • /
    • 2011
  • This paper presents an integrated wind-induced dynamic analysis and computer-based design optimization technique for minimizing the structural cost of general tall buildings subject to static and dynamic serviceability design criteria. Once the wind-induced dynamic response of a tall building structure is accurately determined and the optimal serviceability design problem is explicitly formulated, a rigorously derived Optimality Criteria (OC) method is to be developed to achieve the optimal distribution of element stiffness of the structural system satisfying the wind-induced drift and acceleration design constraints. The effectiveness and practicality of the optimal design technique are illustrated by a full-scale 60-story building with complex 3D mode shapes. Both peak resultant acceleration criteria and frequency dependent modal acceleration criteria are considered and their influences on the optimization results are highlighted. Results have shown that the use of various acceleration criteria has different implications in the habitability evaluations and subsequently different optimal design solutions. The computer based optimization technique provides a powerful tool for the lateral drift and occupant comfort design of tall building structures.

Human Comfort Criterium for Horizontal Vibration of High-Rise Buildings (초고층 건축물의 수평진동 사용성 평가기준)

  • Cho, Kang-Pyo;Hong, Sung-Il;Jeong, Seung-Hwan;Jo, Su-Yeon
    • 유체기계공업학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.105-108
    • /
    • 2006
  • should be in This paper presents review on human comfort criteria in major codes and standards for tall buildings. In general, human comfort criteria of tall buildings have been used by magnitude of wind-induced acceleration response. Two different indexes in determination of the magnitude have been used: the peak value which occurs during a period of time and the rms value averaged over this same period. These distinctive acceleration indexes are discussed in detail and each criterium was reviewed and compared. The distinctions arisen because of the different wave forms, or acceleration signatures were addressed. It is described that which index of acceleration should be adopted in establishment of Korean human comfort criteria. In addition, some arguments from a technical standpoint that favor the use of each index are presented.

  • PDF

Floor Vibration Analysis of Economic Steel (ES) Beam Using Field Measured Acceleration Responses (진동특성을 고려한 ES-빔 공법의 사용성능 평가)

  • Woo, Jong-Yeol;Park, Soo-Yong;Kim, Min-Jin;Hong, Seong-Wook;Doh, Sun-Boong;Choi, Tae-Ho
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.11a
    • /
    • pp.83-84
    • /
    • 2011
  • This study provides floor vibration analysis for a factory constructed by ES-beam using field measured acceleration data. The natural frequencies of the first two modes of floor are extracted from measured data. With this information, a system identification has been performed to produce a numerical model representing existing floor. The peak magnitudes of acceleration for one man walking heel drop load from experiment and numerical model are analyzed using ISO vibration criteria and AIJ vibration performance criteria. The results show that there is no problem in use of ES-beam.

  • PDF

Performance Evaluation of Vertical Vibration of Precast Concrete Slabs (프리캐스트 콘크리트 바닥판의 수직진동 허용치 평가)

  • Heo, Seok-Jae;Lee, Sang-Hyun;Cho, Seung-Ho;Chung, Lan;Kim, Sung-Bae;Park, Sung-Soon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.04a
    • /
    • pp.662-667
    • /
    • 2009
  • In this study, the serviceability of Waffle shaped(WAS) and Double-Tee(DT) precast concrete slabs was evaluated and compared based on the vertical acceleration magnitude induced by walking and heel drop loads. Tests were conducted for practical building structures (a shopping mall in Hanam) of which floor systems used WAS and DT slabs. Natural frequencies of the slabs were similar to those obtained by using analytical models. The measured acceleration level was evaluated by vertical floor acceleration criteria presented by ISO-2631, AIJ(1991, Japan), and a previous study regarding floor vibration limit. Test results showed that both WAS and DT slabs satisfied all the criteria and the maximum acceleration level of WAS slabs was lower than that of DT slabs.

  • PDF

External Noise Analysis Algorithm based on FCM Clustering for Nonlinear Maneuvering Target (FCM 클러스터링 기반 비선형 기동표적의 외란분석 알고리즘)

  • Son, Hyun-Seung;Park, Jin-Bae;Joo, Young-Hoon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.12
    • /
    • pp.2346-2351
    • /
    • 2011
  • This paper presents the intelligent external noise analysis method for nonlinear maneuvering target. After recognizing maneuvering pattern of the target by the proposed method, we track the state of the target. The external noise can be divided into mere noise and acceleration using only the measurement. divided noise passes through the filtering step and acceleration is punched into dynamic model to compensate expected states. The acceleration is the most deterministic factor to the maneuvering. By dividing, approximating, and compensating the acceleration, we can reduce the tracking error effectively. We use the fuzzy c-means (FCM) clustering as the method to divide external noise. FCM can separate the acceleration from the noise without criteria. It makes the criteria with the data made by measurement at every sampling time. So it can show the adaptive tracking result. The proposed method proceeds the tracking target simultaneously with the learning process. Thus it can apply to the online system. The proposed method shows the remarkable tracking result on the linear and nonlinear maneuvering. Finally, some examples are provided to show the feasibility of the proposed algorithm.

Study on the Emergency Assessment about Seismic Safety of Cable-supported Bridges using the Comparison of Displacement due to Earthquake with Disaster Management Criteria (변위 비교를 통한 케이블지지교량의 긴급 지진 안전성 평가 방법의 고찰)

  • Park, Sung-Woo;Lee, Seung Han
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.6
    • /
    • pp.114-122
    • /
    • 2018
  • This study presents the emergency assessment method about seismic safety of cable-supported bridges using seismic acceleration sensors installed on the primary structural elements of them. The structural models of bridges are updated iteratively to make their dynamic characteristics to be similar to those of real bridges based on the comparison of their natural frequencies with those of real bridges estimated from acceleration data measured at ordinary times by the seismic acceleration sensor. The displacement at the location of each seismic acceleration sensor is derived by seismic analysis using design earthquake, and the peak value of them is determined as the disaster management criteria in advance. The displacement time history is calculated by the double integration of the acceleration time history which is recorded at each seismic acceleration sensor and filtered by high cut(low pass) and low cut(high pass) filters. Finally, the seismic safety is evaluated by the comparison of the peak value in calculated displacement time history with the disaster management criteria determined in advance. The applicability of proposed methodology is verified by performing the seismic safety assessment of 12 cable-supported bridges using the acceleration data recorded during Gyeongju earthquake.

Selecting and scaling ground motion time histories according to Eurocode 8 and ASCE 7-05

  • Ergun, Mustafa;Ates, Sevket
    • Earthquakes and Structures
    • /
    • v.5 no.2
    • /
    • pp.129-142
    • /
    • 2013
  • Linear and nonlinear time history analyses have been becoming more common in seismic analysis and design of structures with advances in computer technology and earthquake engineering. One of the most important issues for such analyses is the selection of appropriate acceleration time histories and matching these histories to a code design acceleration spectrum. In literature, there are three sources of acceleration time histories: artificial records, synthetic records obtained from seismological models and accelerograms recorded in real earthquakes. Because of the increase of the number of strong ground motion database, using and scaling real earthquake records for seismic analysis has been becoming one of the most popular research issues in earthquake engineering. In general, two methods are used for scaling actual earthquake records: scaling in time domain and frequency domain. The objective of this study is twofold: the first is to discuss and summarize basic methodologies and criteria for selecting and scaling ground motion time histories. The second is to analyze scaling results of time domain method according to ASCE 7-05 and Eurocode 8 (1998-1:2004) criteria. Differences between time domain method and frequency domain method are mentioned briefly. The time domain scaling procedure is utilized to scale the available real records obtained from near fault motions and far fault motions to match the proposed elastic design acceleration spectrum given in the Eurocode 8. Why the time domain method is preferred in this study is stated. The best fitted ground motion time histories are selected and these histories are analyzed according to Eurocode 8 (1998-1:2004) and ASCE 7-05 criteria. Also, characteristics of both near fault ground motions and far fault ground motions are presented by the help of figures. Hence, we can compare the effects of near fault ground motions on structures with far fault ground motions' effects.

Dynamic Responses Characteristics of Steel Box Railway Bridges Subjected to Train Loading (열차주행에 따른 강박스 철도교의 동적응답특성)

  • Park, Sun-Joon;Kang, Sung-Hoo;Jo, Eun-Pyung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.10a
    • /
    • pp.772-778
    • /
    • 2009
  • By rising the interests of the railroad, It has been required the research about railroad structure. And since 2000, the study about railway bridges caused by steel box railway bridges has been only 0.2%. So I was hard to find out about steel box railway bridges. In this study, I evaluate and analyze 4 types(KTX, Saemaeul, Mugunghwa, Freight) of dynamic caused by train loading, natural frequency and damping ratio, verticality deflection and verticality acceleration, end slope deflection, impact factor for dynamic characteristics analysis. natural frequency was measured 2.45Hz~3.34Hz and damping ratio revealed for 1.26~2.84%. Maximum verticality deflection(4.86mm) was sufficiently satisfied the design criteria(30.1mm), but in the case of verticality acceleration's respond, design criteria BRDM(Bridge Design Manual) & CTRL presentation derive rail limit value 0.35g be more than value 6 time recorded, maximum was measured 0.49g in 3 kinds of train(KTX, Saemaeul, Mugunghwa), except for Freight. Survey impact factor of Experiment bridge was 0.20 which is measured when the KTX(15:04) was driving. impact factor is enough contended with design criteria 0.29 which is presented in domestic railway design criteria and thoroughly guarantee the dynamic stability.

  • PDF