• Title/Summary/Keyword: ac main line

Search Result 42, Processing Time 0.025 seconds

Thyristor전력변환기-전동기계의 무효전력의 처리에 관한 연구

  • 유철로
    • 전기의세계
    • /
    • v.31 no.1
    • /
    • pp.50-58
    • /
    • 1982
  • As a method for improving the power factor and the waveform of ac line current drawn by ac to dc converters, converters of pulse-width control type with forced commutation circuits have been developed in recent years. However, these converters have rather complex commutation circuits which contain auxiliary thyristors in addition to the main thyristors, and their performance is not satisfactory. This paper proposes a new pulse-width controlled ac to dc converter, and analyses its commutation mechanism and its input and output characteristics. The proposed converter circuit consists of a usual thyristor bridge circuit with series diodes to which reactors and diodes are added. This circuit dose not contain auxiliary thyristors, and in this sense it is simpler than the previous converter circuits of pulse-width control type. Since the main thyristors of the converter can be forcedly turned off several times in a half cycle of source voltage, a pulse-width modulation control is possible in order to improve the current waveform as well as the power factor on ac line side. As to dc output side it is shown that the adjustable range of output voltage is wide and the voltage regulation is good due to a rapid reversal of voltage across the commutating capacitors by LC resonance during commutation period. It is also shown that the regenerative operation of the converter is possible.

  • PDF

The Enhancement of Power System Security Using flexible AC Transmission Systems (FACTS) (FACTS 기기를 이용한 전력시스템의 안전도 향상)

  • 송성환;임정욱;문승일
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.3
    • /
    • pp.165-172
    • /
    • 2003
  • This paper presents an operation scheme to enhance the power system security by applying FACTS on Power systems. Three main generic types of FACTS devices are suggested an illustrated. Flow congestions over lines have been solved by controlling active power of series-compensated FACTS devices and low voltages at buses have been solved by controlling reactive power of shunt-compensated FACTS devices. Especially, Especially, UPFC has been applied in both line congestion and low voltages. Two kinds of indices which indicate the power system security level related to line flow and bus voltage are utilized in this paper. They have been minimized to enhance the power system security level through the iterative method and the sensitivity vector of security index is derived to determine the direction to minimum. The proposed algorithm has been tested on the IEEE 57-bus system with FACTS devices in a normal condition and a line-faulted contingency.

Electrical and Structural Design of Air-conditioning Fan Motor for Noise Reduction

  • Han Hyung-Suk;Mo Jin-Yong;Kim Chang-Hyun;Lee Jae-Kwon;Jeong Weui-Bong
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.10
    • /
    • pp.1653-1661
    • /
    • 2006
  • AC induction motors have been widely used for fan motor of the air conditioner indoor unit. Noise of these AC induction motors is usually caused by the coupling effects of structural and electrical systems. The rotating torque and the noise from AC induction motor were discussed in this paper,. First, the modification of motor was carried out in order to reduce the unbalance magneto motive force between main and sub winding. Second, structural modification based on normal mode analysis and modal testing was carried out so that the fan motor does not have the natural frequencies near the 2f-line frequency. Numerical modifications through these two processes were verified by experiments, which showed that the sound pressure level at 2f-line frequency of the modified system became about 25dB less than that of conventional one.

Power Factor with Single Power Stage AC/DC Converter Operated in Active-Clamp Mode (능동 클램프 모드로 동작하는 단일 전력 AC/DC 컨버터에 의한 역률개선)

  • Yoon, Shin-Yong;Baek, Hyun-Soo;Kim, Yong;Kim, Cherl-Jin;Eo, Chang-Jin
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.8
    • /
    • pp.392-401
    • /
    • 2001
  • This paper presents the single-stage high power factor AC to DC converter operated in active-clamp mode. The proposed converter is added active-clamping circuit to boost-flyback single-stage power factor corrected power supply. The active-clamping circuit limits voltage spikes, recycles the energy trapped in the leakage inductance, and provides a mechanism for achieving soft switching of the electronic switches to reduce the switching loss. The auxiliary switch of active-clamping circuit uses the same control and driver circuit as the main switch to reduce the additional cost and size. To verify the performance of the proposed converter, a 100W converter has been designed. The proposed converter gives good power factor correction, low line current harmonic distortions, and tight output voltage regulation, as used unity power factor.

  • PDF

Vibration Test Result and Consideration for AUTS(Advanced Urban Transit System (차세대전동차 진동시험 결과 및 고찰)

  • Hong, Jai-Sung;Kim, Gil-Dong;Lee, Chang-Mu;Won, Jong-Un;Lee, An-Ho;Sung, Chang-Won
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.2276-2279
    • /
    • 2011
  • The AUTS(Advanced Urban Transit System) are developed by government R&D business. This units are under main line performance test in Daebul test line. Both AC and DC could apply to the AUTS for pantagraph voltage. So main transformer and some high voltage filters are added to the under-frame. As a result the total weight of each car(Mc1-Tp1-M-T-Tp2-Mc2) is different. And axle load is different each other. The main characteristics of AUTS(Advanced Urban Transit System) are as follows. One inverter control one motor, DDM(Dircet Drive Motor), no driving gear, plug no end door, self-steering bogie etc. These matters could be appeared to strange vibration. So vibration test is important. The vibration test performed to Mc1 and Tp1. The results were checked to the up-down direction and left-right direction for acceleration.

  • PDF

A Study on the Ground Fault Diagnosis System of Power Station DC Power line (발전소 직류전선로의 지락안전진단 시스템에 관한 연구)

  • 안영주;김남호;이형기
    • Journal of the Korean Society of Safety
    • /
    • v.12 no.1
    • /
    • pp.37-43
    • /
    • 1997
  • There are two kinds of ground fault diagonosis system(GFD), which are for AC and DC power line. The ground fault current of a DC power line Is, first, analyzed for a description of a GFD system for DC power line and then the construction method of the GFD system, which could be processed and analyzed a ground fault current, are explained. Main functions of the system are that the detected ground fault current could be converted to the line insulation resistance by a program and saved in the system memory continuously. Finally a DC power line insulation safety could be decide by a change of the saved Insulation resistance for a given time. This system can detect the ground fault resistance to 100㏀.

  • PDF

A review of Safety standards for insulating materials in overhead contact line (전차선로 절연물의 안전성 평가기준 검토)

  • Lee, Bong-Jae;Jung, Ho-Sung;Lee, Ki-Won;Kwon, Sam-Young;Lee, Ki-Seung;Cho, Ho-Ryung
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.269-274
    • /
    • 2008
  • The Seoul subway is acting the center of public transportation after the opening of the first line on August 15, 1974. and the subway line of the DC traction system is running and building to the ninth line. However, the main insulation parts used in overhead contact line are now imported from overseas products. Therefore, this paper considers domestic manufacture technology, supply easiness and economic effectiveness of insulation products and reviews the safety of support insulator used in rigid conductor line, stem insulator used in movable bracket and AC/DC different phase section insulator that localization development is necessary.

  • PDF

Two Vector Based Direct Power Control of AC/DC Grid Connected Converters Using a Constant Switching Frequency

  • Mehdi, Adel;Reama, Abdellatif;Benalla, Hocine
    • Journal of Power Electronics
    • /
    • v.17 no.5
    • /
    • pp.1363-1371
    • /
    • 2017
  • In this paper, an improved Direct Power Control (DPC) algorithm is presented for grid connected three phase PWM rectifiers. The new DPC approach is based on two main tasks. First the optimization of the look-up table, which is well-known in conventional DPC, is outlined for selecting the optimum converter output voltage vectors. Secondly a very simple and effective method is used to directly calculate their duty cycles from the power errors. Therefore, the measured active and reactive powers are made to track their references using hysteresis controllers. Then two vectors are selected and applied during one control cycle to minimize both the active and reactive power ripples. The main advantages of this method are that there is no need of linear current controllers, coordinates transformations or modulators. In addition, the control strategy is able to operate at constant switching frequencies to ease the design of the power converter and the AC harmonic filter. The control exhibits a good steady state performance and improves the dynamic response without any overshoot in the line current. Theoretical principles of the proposed method are discussed. Both simulation and experimental results are presented to verify the performance and effectiveness of this control scheme.

A Study on the High-Efficiency. High-Power-Factor AC/DC Boost Converter Using Energy Recovery (에너지 회생 스너버를 적용한 고효률, 고역률 AC/DC Boost 컨버터에 관한 연구)

  • Ryu, Chang-Gyu;Kim, Yong;Bae, Jin-Yong;Baek, Soo-Hyun;Choi, Geun-Soo;Gye, Sang-Bum
    • Proceedings of the KIEE Conference
    • /
    • 2004.10a
    • /
    • pp.160-163
    • /
    • 2004
  • A passive lossless turn-on/turn-off snubber network is proposed for the boost PWM converter. Previous AC/DC PFC Boost Converter perceives feed forward signal of output for average current-mode control. Previous Boost Convertor, the Quantity of input current will be decreased by the decrease of output current in light load, and also Power factor comes to be decreased. Also the efficiency of converter will be decreased by the decrease of power factor. The proposed converter presents the good PFC, low line current harmonic distortions and tight output voltage regulations using energy recovery circuit. All of the semiconductor devices in the converter are turned on under exact or near zero voltage switching(ZVS). No additional voltage and current stresses on the main switch and main diode occur. To show the superiority of this converter is verified through the experiment with a 640W, 100kHz prototype converter.

  • PDF

New Single Stage Power Factor Correction AC/DC Converter based on Zero Voltage Switching Full Bridge Topology (영전압 스위칭 풀 브릿지 토폴로지를 기반으로 한 새로운 단일 전력 단 역률개선 AC/DC 컨버터)

  • Kim T.S;Koo G.B;Moon G.W.;Youn M.J
    • Proceedings of the KIPE Conference
    • /
    • 2003.07a
    • /
    • pp.352-357
    • /
    • 2003
  • A new single stage power factor correction(PFC) AC/DC converter based on zero voltage switching(ZVS) full bridge topology is proposed. Since the series-connected two transformers act as both output inductor and main transformer by turns, the proposed converter has a wide ZVS range without additional devices for ZVS. Furthermore, since there is no need to use an output inductor, the proposed converter features high power density. The proposed converter gives the good power factor correction and low line current harmonics distortion. A mode analysis and experiment results are presented to verify the validity of the proposed converter.

  • PDF