• 제목/요약/키워드: ac 접지

검색결과 52건 처리시간 0.027초

대규모 그리드 접지전극의 과도접지임피던스의 측정 (The transient grounding impedance measurment of large grid grounding electrodes)

  • 전병욱;이수봉;이봉;이승주;정동철;이복희
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 추계학술대회 논문집
    • /
    • pp.69-72
    • /
    • 2008
  • This paper presents the transient and conventional grounding impedance behaviors of large grid grounding system associated with the injection point of impulse current The measurement methods consider two possible errors in the grounding-system impedances: (1) ground mutual resistance due to current flow through ground from the ground electrode to be measured to the current auxiliary, (2) ac mutual coupling between the current test lead and the potential test lead The test circuit was set to reduce the error factors. The transient grounding impedance depends on the rise time and injection point of impulse current It is effective that grounding conductor is connected to the center of the large grid grounding system.

  • PDF

직류회로의 단락전류 계산⑴

  • 이성우
    • 전기기술인
    • /
    • 제222권2호
    • /
    • pp.30-36
    • /
    • 2001
  • 전회에 걸쳐서 AC 전력계통의 3상 단락전류와 1선 지락전류 및 계통접지 방식에 대하여 살펴 보았다. 본 장에서는 실제로 현장에서 사용되고 있는 Batteries, Rectifiers, DC Generators 등으로 구성되는 DC System의 제반 특성과 고장전류 계산을 쉽게 이해하도록 해설하고자 한다.

  • PDF

정보통신설비용 뇌서지 보호장치의 효과적인 설치기법 (An Effective Installation Method of lightning Protective Devices for Information and Communication Facilities)

  • 이복희;이동문;강성만;엄주홍;이승칠
    • 조명전기설비학회논문지
    • /
    • 제16권5호
    • /
    • pp.90-96
    • /
    • 2002
  • 정보통신망 신호선로는 전원선과 더불어 가공선로로 구성되어 있어 뇌서지에 대한 노출이 심각하다. 전원선로의 접지와 통신선로 접지 상호간에 나타나는 전위차로 인하여 통신선에 접속된 전자장비는 뇌서지에 의해 쉽게 손상될 수도 있다. 본 연구에서는 뇌서지로부터 정보통신설비를 신뢰성 높게 보호하는 기법을 개발할 목적으로 실규모 회로에서 서지보호장치의 성능과 신뢰성에 대한 실증실험을 수행하였다. 전원선과 통신선을 통하여 입사한 뇌서지 에 대한 서지보호장치의 동작특성과 보호장치의 설치방법이 뇌서지 보호효과에 미치는 협조특성을 평가하였다. 그 결과 정보통신설비용 뇌서지 보호장치를 바이패스 어레스터를 이용한 공통접지법으로 설치하는 것이 매우 효과적임을 확인하였다.

IEC 60364의 접지방식에 기반한 안전성 평가 시험장치의 모델링 및 구현에 관한 연구 (Modeling and Implementation of Safety Test Device for Grounding System Based on IEC 60364)

  • 김순식;한병길;이후동;페레이라 마리토;노대석
    • 한국산학기술학회논문지
    • /
    • 제22권6호
    • /
    • pp.599-609
    • /
    • 2021
  • 국내 접지방식은 2021년부터 IEC 60364에서 제시하는 접지방식을 새롭게 채택하고 있다. 이 접지방식은 인체접촉사고 발생 시, 접촉전압과 통과전류에 대한 특성이 다양하게 나타날 수 있어, 인체에 대한 안전성 평가가 구체적으로 요구되고 있다. 또한, 한국전기안전공사나 대한전기협회에서 IEC 60364의 접지방식에 대한 안전기술 교육을 부분적으로 수행하고 있지만, 안전성을 평가할 수 있는 시험장치가 미흡하여, 전기안전관리자에 대한 교육이 어려운 실정이다. 따라서, 본 논문에서는 IEC 60364의 접지방식별 안전성 평가를 수행할 수 있는 시험장치를 모델링하고, 이를 바탕으로 시험장치를 구현한다. 즉, 전력계통 상용해석 프로그램인 PSCAD/EMTDC를 이용하여, 계통 전원부, 접지방식별 시험장치부, 보조장치부로 구성된 안전성 평가 시험장치의 모델링을 제시하고, 계통전원부, TT접지방식 시험장치부, TN-S접지방식 시험장치부, 모니터링부로 구성된 안전성 평가 시험장치를 구현한다. 상기의 모델링과 시험장치를 이용하여, TT접지방식과 TN-S접지방식의 인체 안전성 특성을 분석한 결과, TT접지방식의 경우 고장점 임피던스가 0[Ω], 10[Ω], 100[Ω]에서 인체 통과전류는 각각 104[mA], 87.4[mA], 35.5[mA]가 산정되었고, TN-S접지방식의 경우 54.9[mA], 4.1[mA], 0.4[mA]가 산정됨에 따라, TN-S접지방식이 TT접지방식에 비하여 감전에 대한 보호가 우수함을 알 수 있고, 저압수용가에서 사용 중인 TT 접지방식에서 TN-S 접지방식으로 전환하면 감전에 대한 보호성능을 향상시킬 수 있음을 알 수 있었다.

배전계통의 순간전압 상승에 따른 SPD 고압 TOV 시험설비 구축 (Temporary Over Voltage Test System for Surge Protective Device in Low Distribution system)

  • 김용성;김언석;안건현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1391_1392
    • /
    • 2009
  • 본 논문에서는 저압 서지보호기의 안전성평가를 위한 고압 계통 고장에 의한 순간 과전압시험 설비를 IEC 61643-1의 따라 구축 하였고, 구축된 시험설비의 성능을 분석하였다. 고압 계통의 순간 과전압시험 기준은 가장 일반적인 미국전력 계통의 기준인 3상 4선식이 반영이 되었으며 전압의 크기는 AC 1200V이다. 본 논문에서는 순간과전압이 상과 접지사이의 개방전압 AC 1200V을 약 200ms 동안 인가되는지를 측정하였고, 단락전류가 AC 300A이상을 측정하였다.

  • PDF

전위강하법에 의한 접지임피던스 측정 시 오차요인 분석 (Analysis of error factors of the Fall-of-potential test method in measurements of grounding impedance)

  • 전병욱;이수봉;정동철;이복희;안창환
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 춘계학술대회 논문집
    • /
    • pp.313-316
    • /
    • 2008
  • This paper presents the error factors of Fall-of-potential test method used in measurements of the grounding-system impedance. This test methods inherently can introduce two possible errors in the measurements of grounding-system impedance: (1) ground mutual resistance due to current flow through ground from the ground electrode to the current probe, (2) ac mutual coupling between the current test lead and the potential test lead. The errors of ground mutual resistances and ac mutual coupling are expressed by the equation in calculating grounding impedance. These equations were calculated by Matlab that is commercial tool using mathematical calculation. The results of calculation were applied to correct grounding impedance.

  • PDF

배전용 변압기를 통하여 저압 전원선으로 전파되는 뇌서지 (Lightning Surges Transferred to Low-voltage AC Power Lines through Distribution Transformers)

  • 이복희;이동문;이수봉
    • 조명전기설비학회논문지
    • /
    • 제17권4호
    • /
    • pp.94-99
    • /
    • 2003
  • 정밀하고 소형화된 전자기기 사용의 증가로 인한 전원공급의 질적 향상에 대한 필요성이 강하게 증가하고 있다. 저압전원 배전계통에서의 과도 과전압은 직격 또는 유도뢰에 의해 유도되어지고, 가정, 사무실, 공장 등의 자동화시스템이나 병원설비와 같은 중요한 시스템의 손상이나 고장의 원인이 되고 있다. 본 논문에서는 임펄스 발생기를 이용하여 배전용 변압기를 거쳐 저압 전원시스템으로 이행되는 뇌과전압의 양상에 대하여 실험적으로 조사하였다. 배전용 변압기의 1차측에 설치한 피뢰기와 수용가측 추가접지는 저압 전원시스템으로 이행되는 뇌서지전압의 제한에는 크게 기여하지 않았다.

원통형 바늘 구조의 플라즈마 제트 방출 특성 (Characteristics of Plasma Plume with a Cylindrical Syringe Plasma Jet Device)

  • 임현교;김동준;김정현;한상호;조광섭
    • 한국진공학회지
    • /
    • 제20권1호
    • /
    • pp.14-21
    • /
    • 2011
  • 유리관에 삽입된 주사기 바늘을 이용한 플라즈마 제트 장치의 특성을 조사하였다. 원통형 주사기 바늘 전극에 교류 고전압을 인가하고, 유리관 끝에 설치된 접지전극의 형태에 따른 플라즈마의 방출 특성을 조사하였다. 접지전극이 없는 경우 방전 개시 전압이 약 3 kV이며, 플라즈마 방사 길이는 약 10 mm이다. 또한 높은 방전 개시 전압으로 인하여 플라즈마 방사 길이 및 전류 최소량의 제어가 어렵다. 내부접지 전극의 경우는 방전 개시 전압이 약 1 kV로 낮다. 그러나 플라즈마 전류가 내부에 위치한 접지 전극으로 흐르기 때문에 유리관 끝으로부터 플라즈마가 방출되지 않는다. 외부접지 전극의 경우는 인가전압 1~2 kV에서, 방전 전류 1~4 mA이며 플라즈마 방사 길이를 0~10 mm의 범위에서 용이하게 제어된다.

구-구갭의 섬락 특성에 미치는 연소화염의 영향 (Influence of the Combustion Flames on the Flashover Characteristics of the Sphere-Sphere Air Gap)

  • 김인식;이상우
    • 조명전기설비학회논문지
    • /
    • 제19권1호
    • /
    • pp.44-51
    • /
    • 2005
  • 본 연구에서는 구-구갭을 수평 배치하였을 때, 연소화염에 의한 교류 및 직류 플래시오버전압 특성을 조사하였다. 화염에 의한 플래시오버 극성을 조사하기 위해 전압 및 전류파형을 측정하였으며, 플래시오버가 발생되기 전에 쿨롱력에 의한 화염의 형상 변화를 관찰하였다. 또한 플래시오버 전압의 저하 요인으로서 상대공기밀도의 저하 및 연소화염의 열전리 영향에 대해 고찰하였다. 실험 결과, 구-구갭에서 접지측 전극과 갭길이의 비를 k라고 할 때, 화염위치 k:0(접지측), k=0.5(중앙부) 및 k=1.0(전원측)인 경우 화염에 의한 교류 섬락전압의 평균값은 화염이 없을 때에 비해 각각 79.9, 82.9 및 $87.5[\%]$ 저하되었으며, 또한 화염의 높이 h=0, h=5 및 h=9[cm]일 때 교류 플래시오버 전압의 평균값은 화염이 없는 경우를 기준으로 하였을 때 각각 85.0, 40.8 및 $28.2[\%]$ 저하되었다. 소규모 연소화염에서의 열전리 영향은 크지 않는 것으로 나타났다.

AC PDP에서 휘도효율을 향상시키기 위하여 자기소거 방전을 발생시키는 새로운 구동방법 (A New Driving Method Generating Self-Erasing Discharge to Improve Luminous Efficiency in AC PDP)

  • 조병권
    • 전자공학회논문지
    • /
    • 제51권2호
    • /
    • pp.168-172
    • /
    • 2014
  • 교류형 플라즈마 디스플레이에서 유지기간 중에 자기소거 방전을 발생시켜서 휘도효율을 향상시키기 위한 새로운 유지 구동방법이 제안된다. 일반적인 AC PDP에서 하나의 서브필드 시간은 초기화, 기입, 유지기간으로 나누어져 있다. 그 중 유지기간 동안에 2개의 상판 전극인 X와 Y 전극에 교대로 사각 유지파형이 인가되어 화상을 표시하기 위한 유지기간 중의 플라즈마 방전이 연속적으로 발생된다. 그러나 일반적인 구동방법에 있어서 하판의 A전극에는 기입기간에서 종래의 구동방법에서는 셀을 선택할 때만 기입파형이 구동되고 유지기간 중에는 접지 상태로 놓여있으므로 유지 방전에 관여하지 않는다. 본 실험에서는 유지기간 중에 자기소거 방전을 발생시켜 휘도효율을 상승시키기 위하여 유지펄스의 뒷부분에서 음의 펄스를 A전극에 인가하였다. A전극의 음의 펄스는 주 유지방전이 발생된 후 셀 내부의 공간전하들을 벽전하로 전환시켜서 3전극의 전위가 접지 상태가 될 때 재 축적된 벽전하로 인하여 방전을 한번 더 유도시켰다. 그 결과, 유지기간 중 A 전극의 전압 높이에 따른 휘도 효율을 측정하였고 최적의 구동전압을 적용했을 때 휘도효율을 측정한 결과 종래와 비교해서 약 40 % 향상되었다.