• Title/Summary/Keyword: abtuse angle

Search Result 3, Processing Time 0.014 seconds

The Effect of the Diameter and Anastomotic Angle on the Compliance and the Stress Distribution of the End-to-side Anastomosis. (직경 및 문합각도가 단측 문합의 컴플라이언스 및 응력분포에 미치는 영향)

  • 한근조;김영호
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.2
    • /
    • pp.183-188
    • /
    • 1998
  • Von Mises stress and compliance distribution was evaluated using a finite element analysis on the end-to-side anastomosis of an artery with length of 20-24mm, inner diameter of 4mm, thickness of 0.5mm and a PTFE graft with length of 10mm, inner diameter of 2mm, thickness of 0.2mm when the anastomotic angle was taken from 30$^{\circ}$~90$^{\circ}$ in every 10$^{\circ}$ and the diameter ratio from 0.1-1 in every 0.1. The inner pressure of 1330 dyne/$\textrm{mm}^2$ was applied inside the 2 conduits. It was found that the compliance whose magnitude is larger on the acute angle anastomotic side than on the abtuse angle side became larger as the anastomotic angle became smaller and the diameter ratio larger and that the equivalent stress on the acute angle anastomotic side was larger than that on the abtuse angle side and became larger as the anastomotic angle and the diameter ratio became larger.

  • PDF

The Effect of the diameter and anastomotic angles on the compliance and the stress distribution of the end-to-side anastomosis (직경 및 문합각도가 단측 문합의 컴플라이언스 및 응력분포에 미치는 영향)

  • Han, G.J.;Kim, Y.H.;Kim, H.S.;Ann, S.C.;Jang, W.S.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.05
    • /
    • pp.334-337
    • /
    • 1997
  • Von Mises stress and compliance distribution was evaluated using a finite element analysis on the end-to-side anastomosis of an artery with length of $20\sim24mm$, inner diameter of 4mm, thickness of 0.5mm and a PTFE graft with length of 10mm, inner diameter of 2mm, thickness of 0.2mm when the anastomotic angle was taken from $30^{\circ}\sim90^{\circ}$ in every $10^{\circ}$ and the diameter ratio from $0.1\sim1$ in every 0.1. The inner pressure of $1330dyne/mm^2$ was applied inside the 2 conduits. It was found that the compliance whose magnitude is larger on the acute angle anastomotic side than on the acute angle side became larger as the anastomotic angle became smaller and the diameter ratio larger and that the equivalent stress on the acute angle anastomotic side was larger than that on the abtuse angle side and became larger as the anastomotic angle and the diameter ratio became larger.

  • PDF

A Study on the Simulation and DSF Molding of V-groove Type Light Guide for a Backlight Unit (백라이트 유닛용 V-그루브 도광판의 전산모사 및 DSF성형에 관한 비교연구)

  • Cho K. H.;Yoon K. H.
    • Transactions of Materials Processing
    • /
    • v.14 no.3 s.75
    • /
    • pp.282-290
    • /
    • 2005
  • Nowadays, TFT-LCD is widely used as display unit of many digital devices. And, the backlight unit(BLU) is used as a light source of TFT-LCD module. In the backlight unit, the most important component is a light guide, which guides the input light to the TFT-LCD module uniformly. Recently, many researchers have focused on improving the efficiency of BLU by changing the design and structure of a light guide. In the present paper, a series of simulation was performed to find the optimal luminance distribution of emanated light from the given geometry as the first step. From the results of simulations for the light guide with given V-groove pattern, the emanated light from it is mostly affected by the groove angle. In the case of acute angle, about 74 degrees was found as optimal angle to satisfy the restrictions of angular luminance distribution, FWHM, the maximum luminance, etc. However, as far as the average luminance value was concerned, the case of 120 degrees(abtuse angle) was found to be the best while prism films were added to the BLU. As a next step the light guide samples of 74 and 120 degrees were manufactured by DSF method, which was recently proposed by the authors. Of course, most of design parameters were chosen by the aid of simulation results. Finally, the results of average luminance values were compared between the simulation and DSF molded samples.