• Title/Summary/Keyword: absorption effect

Search Result 3,113, Processing Time 0.034 seconds

The effect of diffusers on the measurement of sound absorption in a reverberation room (잔향실법 흡음률 측정에 미치는 확산체의 영향)

  • Han, Hee-Kab;Kim, Kyung-Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.1194-1197
    • /
    • 2006
  • Recently, international standard for measurement of sound absorption in a reverberation room has been amended. In the revised version, temperature, humidity and air pressure conditions are strictly restricted and also the concrete procedures are presented to reduce the differences in test results by adding inspection of diffusion, measurement uncertainty etc. In this paper, the systematic tests are conducted based on the inspection guide of diffusion defined by ISO 354 and the effects of diffusers on the measurement of sound absorption ratio are considered. As a result, we perceived that the averaged sound absorption ratio in mid and high frequency range is expected to measure around $0.05{\sim}0.1$ higher in high sound absorption material. Therefore, as for the reverberation room for measurement of sound absorption, we need to take into consideration not only the spatial standard deviation of sound pressure mandated by ISO 3741, but also, inspection regulation of diffusion showed by ISO 354.

  • PDF

Effect of Mixed Micelles on Jejunal and Nasal Absorption Enhancement of Piperacillin (피페라실린의 공장 및 비점막흡수 촉진에 대한 혼합미셀의 효과)

  • Park, Gee-Bae;Lee, Yong-Suk;Rho, Hyun-Goo;Lee, Kwang-Pyo
    • Journal of Pharmaceutical Investigation
    • /
    • v.23 no.2
    • /
    • pp.71-80
    • /
    • 1993
  • The purpose of this study was to compare the intrinsic absorptivity of piperacillin in the jejunum and the nasal cavity, to investigate the effect of bile salts, fatty acids and their mixed micelles on the intestinal and nasal absorption of piperacilIin, to examine the reversibiIity of bile salt-fatty acid mixed micelles absorption promoting action and to design an effective intranasal drug delivery system for antibiotics. And absorption promoters used were bile salts [sodium cholate (NaC), sodium glycocholate (NaGC)], unsaturated fatty acids [oleic acid (OA), linoleic acid (LA)] and their mixed micelles (NaC-LA). The present study employed the in situ nasal and intestinal perfusion technique in rats. The apparent permeabilities $(P_{app})$ of piperacillin were $0.40{\pm}0.04{\times}10^{-5}cm/sec(mean{\pm}S.E)$ in the jejunum and $1.32{\pm}0.08{\times}10^{-5}\;cm/sec$ in the nasal cavity, which indicated that intrinsic absorptivity of piperacillin was greater in the nasal cavity than in the jejunum. When absorption promoters were used in the rat nasal cavity, the decreasing order of apparent piperacillin permeability $(P_{app},\;10^{-5}\;cm/sec)$, corrected for surface area of absorption, was NaC-LA $(4.62{\pm}0.16)$> NaC $(4.36{\pm}0.32)$>LA$(2.24{\pm}0.26)$ NaGC $(2.17{\pm}0.21)$>OA $(1.53{\pm}0.16)$. The increase in permeability of piperacillin was 3.5-fold in the rat nasal cavity and 1.5-fold in the rat jejunum for formulations containing NaC-LA mixed micelles as compared to those without absorption enhancer. The effect of NaC-LA mixed micellar solutions was synergistic and was greater than that with single adjuvant. The reversibility of nasal mucosal permeability was observed within approximately 2 hr after removal of NaCLA mixed micelles from the nasal cavity. These results suggest that NaC-LA mixed micelles can be used as nasal mucosal absorption promoters of poorly absorbed drugs.

  • PDF

A Study on the Model of Light Interception and Absorption in Plant Canopies (植物의 樹冠에 있어서 光의 遮斷과 吸收 Model 에 關한 硏究)

  • Chang, Nam-Kee;Kyung-Oh Kwon
    • The Korean Journal of Ecology
    • /
    • v.8 no.2
    • /
    • pp.61-68
    • /
    • 1985
  • The modeling of interception and absorption of light was studied in plant canopies at Mt. Kwanak. Followering results were obtained. Light intensity passing through the stacked leaves is attenuated exponentially. This phenomenon seems to be more clearly applied to the plant canopies, if they have large cumulative leaf area and are matured densely. Light interception and absorption are influenced by leaf thickness, shape pigments, and leaf area, and they have great effect on the maturation of canopies. It was confirmed that the light penetrating through the stratified canopies is decreased exponentially in dual pattern. The cumulative leaf area of a definite space in a certain plant canopy is the same as the growth of leaf area of the canopy at that time. A hypothetical model for calculating the light absorption in plant canopies, was established on the bases of phenomena that incident light is captured at the maximum level and light inerception effect is minimized by leaves.

  • PDF

A Study on Acoustical Characteristics in Microcellular Foaming Plastics (초미세 발포 플라스틱의 음향특성 연구)

  • Cha, Sung-Woon;Kim, Hak-Bin;Lee, Byoung-Hee;Kang, Yon-Jun
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.9
    • /
    • pp.71-77
    • /
    • 2008
  • Microcellular foaming plastics create a sensation at polymer industrial for lowering product costs and overcoming a lowering of mechanical intensity. Among many advantages, microcellular foaming plastics is well known to have a good acoustical properties. This research based on the experiment of sound absorption and transmission characteristics inquire into acoustical properties of microcellular foaming plastics. Difference of transmission loss of microcellular foaming plastics and solid materials was defined as cell effect. Also, cell effect is expressed by sound reflection and sound absorption. This study is expected to fundamental research to present economical, functional alternative plan for products using sound absorption and transmission materials.

Combined Effect of Fluorouracil with Metoclopramide or Propantheline Bromide in Rats and Rabbits (Fluorouracil과 Metoclopramide 및 Propantheline.Bromide와의 병용시(倂用時) 항암효과(抗癌効果)에 관한 연구(硏究))

  • Choi, Jun-Shik;Lee, Jin-Hwan;Baik, Chai-Sun
    • Journal of Pharmaceutical Investigation
    • /
    • v.14 no.1
    • /
    • pp.11-18
    • /
    • 1984
  • This paper was attempted to study on the effect of metoclopramide or propantheline on the absorption rate and bioavailability and pharmacokinetic parameter of fluorouracil in rats and rabbits. The result are as follows; Metoclopramide increased the absorption rate of fluorouracil but propantheline decreased in situ experiment with rat small intestine. Metoclopramide increased the blood level and relative bioavailability and absorption rate constant of fluorouracil in rabbits. Prolonged the peak blood level (tmax) and decreased the absorption rate constant (Ka) but did not affect the blood level and relative bioavailability of fluorouracil in rabbits. As a matter of fact, it is considerd that the coadministration of metoclopramide or propantheline is more desirable than the single administration of fluorouracil for available dosage regimen.

  • PDF

Computer Simulation on the Performance of Air-Cooled Condenser for an Absorption Heat Pump (흡수식 열펌프용 공냉식 응축기의 성능특성에 관한 시뮬레이션)

  • 박윤철;민만기
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.8
    • /
    • pp.1999-2011
    • /
    • 1995
  • Computer simulation was conducted to study performance characteristics of air-cooled condenser of a double effect absorption heat pump with variations of saturation pressures and mass flow rates of the refrigerant ; volume flow rates, relative humidities and temperatures of the air The vertically installed condenser had the staggered tube array with continuous plate fins of wavy type. When the saturation pressure of the condenser was decreased from 760 torr to 20 torr, heat transfer rates and condensing rates of refrigerant were decreased. If excess refrigerant flows in the condenser, the pressure and saturation temperature of the condenser were increased which makes the refrigerating capacity of an absorption heat pump reduced.

The Effect of Temperature on Corrosion of Absorption Refrigeration Systems Using $LiBr-H_2O$ Working Fluids ($LiBr-H_2O$계 흡수식냉동기의 부식에 미치는 온도의 영향)

  • 임우조;정기철
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.26 no.1
    • /
    • pp.125-131
    • /
    • 2002
  • This paper was studied on the effect of temperature on corrosion of absorption refrigeration systems using $LiBr-H_2O$ working fluids. In the fresh water and 62 % lithium bromide solution at $70^{\circ}C$, polarization test of SS 400, Cu(C1220T-OL) and Al-Ni bronze was carried out. And polarization behavior, polarization resistance characteristics, corrosion rate(mmpy) and corrosion sensitivity of materials forming absorption refrigeration systems was considered. The main results are as following: (1) As the experimental temperature increase, the change of corrosion rate of Al-Ni bronze become duller than SS 400 and Cu in 62% lithium bromide solution. (2) According as corrosion environment is changed from fresh water to 62% lithium bromide solution, potential change of Cu and Al-Ni bronze become less noble than SS 400. (3) The corrosion sensitivity of Al-Ni bronze was duller than that of Cu and SS 400 in 62% LiBr solution.

Effect of the welding residual stress redistribution on impact absorption energy (재분포된 용접잔류응력이 충격흡수에너지에 미치는 영향)

  • Yang, Zhaorui;Lee, Youngseog
    • Journal of Welding and Joining
    • /
    • v.33 no.1
    • /
    • pp.72-79
    • /
    • 2015
  • Evaluation of fracture toughness of welded structures has a significant influence on the structural design. However the residual stresses is redistributed while the welded structures is cut for preparing specimens. This study investigated an effect of the welding residual stress redistribution on the impact absorption energy of Charpy specimen. SA516Gr70 steel plate by at the flux cored arc welding (FCAW) and gas tungsten arc welding(GTAW) was cutting. Specimens for Charpy impact testing were taken from the welded plate. Two material removal mechanisms (wire cutting and water jet) were used to make the specimens. Welding residual stress and redistribution residual stress were measured using the XRD (X-Ray Diffraction) method. The amount of redistribution of residual stress depends on the different material removal mechanism. Redistribution of residual stress of reduced the impact absorption energy by 15%.

Dynamic Analysis of Single-Effect/Double-Lift Libr-Water Absorption System using Low-Temperature Hot Water (저온수를 이용하는 일중효용/이단승온 리튬브로마이드-물 흡수식 시스템의 동적 해석)

  • Kim, Byong-Joo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.12
    • /
    • pp.695-702
    • /
    • 2009
  • Dynamic behavior of Libr-water absorption system using low-temperature hot water was investigated numerically. Thermal-hydraulic model of single-effect/double-lift 100 RT chiller was developed by applying transient conservation equations of total mass, Libr mass, energy and momentum to each component. Transient variations of system properties and transport variables were analysed during start-up operation. Numerical analysis were performed to quantify the effects of bulk concentration and part-load operation on the system performance in terms of cooling capacity, coefficient of performance, and time constant of system. For an absorption chiller considered in the present study, optimum bulk concentration was found to exist, which resulted in the minimum time constant with stable cooling capacity. COP and time constant increased as the load decreased down to 40%, below which the time constant increased abruptly and COP decreased as the load decreased further.

The Effect of Shape of Core Cell on Shock Absorption Characteristics of Biomimetically Inspired Honeycomb Structures

  • Kim, Tae-Min;Kim, Jung-Soo
    • International Journal of Railway
    • /
    • v.4 no.4
    • /
    • pp.103-108
    • /
    • 2011
  • The effect of the core cell shape on shock absorption characteristics of biomimetically inspired honeycomb structures has been numerically investigated. The finite element models of honeycomb test specimen composed of five core cells of identical mass have been constructed, and numerical simulations have been run on PAMCRASH. The dimensions of the sides of core cells as well as the angle between the sides have been shown to influence the shock absorption characteristics of the honeycomb structure. The specimen with regular hexagonal core cell shape is found to show the best shock absorbing capacity, and specimen with rectangle-like core cell are found to provide good shock absorbing characteristics.

  • PDF