International Journal of Aeronautical and Space Sciences
/
제18권1호
/
pp.138-143
/
2017
A performance analysis for a pulsed plasma thruster(PPT) has been conducted to predict the thrust and current change. Two models were implemented - a one-dimensional lumped circuit analysis model and the Teflon ablation model provided by Michael Keidar. The circuit model incorporating resistance and inductance models was adapted to predict the magnitude of the discharge current. Numerical simulations like current discharge rates with different voltages were reasonably well compared with experimental data. The effects of Teflon ablation on thruster characteristics were investigated.
In this research, authors tried to measure the shape of the nozzle throat of KL-3 engines, which is the main engine of KSR-III rocket, to find the increase of nozzle area caused by the thermal ablation. For the purpose, we invented an image-based method instead of the 3D pointer, which is actually inaccessible to such large scale engines. As a result, our equipment showed satisfactory accuracy and performance. Analysing the results of experiments, we find that the pattern of ablation is determined by the spray pattern and that the process of thermal ablation phenomena can be categorized in three regimes - the first regime that the shape of nozzle throat is maintained and ablation is negligible, the second regime that saw-tooth form is developed and ablation is accelerated, and the third regime that the saw-tooth form is already established and the growth of ablation rate is reduced. Also, we find that the ratio of area increase after 60 seconds combustion is +5.82% and conclude that this figure is acceptable and satisfactory.
In this paper, a pulsed picosecond laser dressing method for bronze-bonded diamond wheel is studied systematically and comprehensively. The picosecond laser pulse ablation experiment is carried out, and the ablation thresholds of bronze-bonded and diamond abrasive particle are measured respectively. The results indicate that the single-pulse ablation thresholds of bronze-bonded are 0.89J/cm2, 0.24J/cm2 during strong/weak ablation stages. And the multi-pulse ablation thresholds of diamond abrasive particle are 1.69J/cm2, 0.49J/cm2 during strong/weak ablation stages. Obviously, diamond grains have less thermal damage during the process of gentle ablation. The diamond grains of the grinding wheel surface are graphitized during laser dressing. The bronze-bonded is relatively smooth and organizational stability, and the diamond grits have suitable prominent height, which are beneficial to maintain the good grinding performance of dressed bronze-bonded diamond grinding wheels.
Sae-Jin Park;Jae Hyun Kim;Jeong Hee Yoon;Jeong Min Lee
Korean Journal of Radiology
/
제24권2호
/
pp.86-94
/
2023
Objective: To compare Octopus multipurpose (MP) electrodes, which are capable of saline instillation and direct tissue temperature measurement, and conventional electrodes for radiofrequency ablation (RFA) in porcine livers in vivo. Materials and Methods: Sixteen pigs were used in this study. In the first experiment, RFA was performed in the liver for 6 minutes using Octopus MP electrodes (n = 15 ablation zones) and conventional electrodes (n = 12 ablation zones) to investigate the effect of saline instillation. The ablation energy, electrical impedance, and ablation volume of the two electrodes were compared. In the second experiment, RFA was performed near the gallbladder (GB) and colon using Octopus MP electrodes (n = 12 ablation zones for each) with direct tissue temperature monitoring and conventional electrodes (n = 11 ablation zones for each). RFA was discontinued when the temperature increased to > 60℃ in the Octopus MP electrode group, whereas RFA was performed for a total of 6 minutes in the conventional electrode group. Thermal injury was assessed and compared between the two groups by pathological examination. Results: In the first experiment, the ablation volume and total energy delivered in the Octopus MP electrode group were significantly larger than those in the conventional electrode group (15.7 ± 4.26 cm3 vs. 12.5 ± 2.14 cm3, p = 0.027; 5.48 ± 0.49 Kcal vs. 5.04 ± 0.49 Kcal, p = 0.029). In the second experiment, thermal injury to the GB and colon was less frequently noted in the Octopus MP electrode group than that in the conventional electrode group (16.7% [2/12] vs. 90.9% [10/11] for GB and 8.3% [1/12] vs. 90.9% [10/11] for colon, p < 0.001 for all). The total energy delivered around the GB (2.65 ± 1.07 Kcal vs. 5.04 ± 0.66 Kcal) and colon (2.58 ± 0.57 Kcal vs. 5.17 ± 0.90 Kcal) were significantly lower in the Octopus MP electrode group than that in the conventional electrode group (p < 0.001 for all). Conclusion: RFA using the Octopus MP electrodes induced a larger ablation volume and resulted in less thermal injury to the adjacent organs compared with conventional electrodes.
Background: To explored the value of 3D C-arm CT (CACT) guidance system in performing radiofrequency ablation (RFA) following transarterial chemoembolizationon (TACE) for hepatocellular carcinomas. Materials and Methods: RFA of hepatocellular carcinomas (HCC) were performed on 15 patients (21 lesions) with the assistance of CACT guidance system. Technical success, procedure time, complications and patient radiation exposure were investigated. The puncture performance level was evaluated on a five-point scale (5-1: excellent-poor). Complete ablation rate was evaluated after two months follow-up using enhanced CT scans. Results: The technical success rate of RFA procedure under CACT navigation system was 100 %. Mean total procedure time was $24.24{\pm}6.53min$, resulting in a mean effective exposure dose of $15.4{\pm}5.1mSv$. The mean puncture performance level rated for CACT guided RFA procedure was $4.87{\pm}0.35$. Complete ablation (CA) was achieved in 20 (95.2%) of the treated 21 tumors after the first RFA session. None of patients developed intra-procedural complications. Conclusions: 3D CACT guidance system enables reliable and efficient needle positioning by providing real-time intraoperative guidance for performing RFA on HCCs.
본 논문에서는 전립선 비대증 환자 치료 시 조직 제거에 사용되는 두 파장들을 비교 연구하였다. 가시광선 영역인 532 nm는 혈액 속의 헤모글로빈에 의한 흡수율이 높은 반면, 근적외선 영역인 980 nm는 물에 의한 빛의 흡수율이 높다. 동물의 간 조직을 각각의 레이저를 이용하여 40 W 출력에서 제거하였으며, 조직 제거율을 제거 횟수, 제거 부피, 열손상 정도를 통해 검사하였다. 532 nm의 경우 높은 레이저 흡수율로 인해 조직 제거율이 980 nm 보다 4배까지 증가하였으며, 열손상은 상대적으로 약 30%까지 낮게 나타났다. 파장에 관계없이 제거 횟수가 높을수록 단위 횟수당 제거율이 낮아졌으며, 이는 레이저 빛이 거리에 따라 발산함과 동시에 제거된 조직의 입자들이 먼지 방해 현상을 일으킴으로써 효율의 저하를 일으켰음을 짐작할 수 있었다. 보다 효율적인 열적 제한 상태와 높은 흡수율로 인해 가시광선 영역의 532 nm가 근적외선 980 nm 보다 전립선 치료에 있어서 더욱 효율적인 파장임을 알 수 있었으며, 이러한 발견을 전임상 및 임상을 통해 확인할 계획이다.
Carbon-based materials have been known as ablative material and have been used for thermal protection systems. Ablation is an erosive phenomenon that results in thermochemical and thermomechanical changes on materials. Ablation resistance is one of the key properties that determines performance and life-time of the thermal protection material under ablative conditions. In this study, ablation properties of graphite, 3-dimensional (C/C) composites (needle-punched type and rod type) were investigated byusing a plasma wind tunnel which produce a supersonic plasma flow from a segmented arc heater with the power level of 0.4 MW. The mass losses and surface roughness changes which contain main result of the ablation are measured. A morphological analysis ofthe carbon-based materials, before and after the ablation test, are performed through field emission scanning electron microscopy (FE-SEM) and non-contact 3D surface measuring system. Electronic balance and a portable surface roughness tester were used for evaluation of the recession and mass loss of the test samples.
소량의 CNT 나노입자를 함유한 CNT-페놀 복합재료를 제조하여 삭마 효과를 확인하였다. CNT 함량을 0.1 wt%에서 0.3 wt%까지 증가시킴에 따른 인장, 압축 강도를 평가하고 삭마 저항성에 대한 차이를 분석하였다. 산소와 등유를 혼합하여 화염 발생시켜 재료의 삭마 효과를 평가하였다. FE-SEM을 이용하여 삭마 실험 이후 발생된 시편의 미세 구조 변화를 확인하였다. CNT 함유 정도에 따른 TGA 열분석을 시도하여 열적 안정성을 평가하였다. 0.3wt% CNT-페놀 복합재료가 일반 페놀 수지 및 0.1 wt% CNT-페놀 복합재료보다 삭마율이 낮았다. 삭마에 따른 재료 변화 메커니즘을 규명하기 위해 TGA 분석 결과와 FE-SEM을 이용한 미세 구조 결과를 분석하였다. 고열의 화염을 이용한 삭마 실험을 통해 시편 내부의 CNT 입자가 존재하는 미세구조를 확인할 수 있었다. 수지 내부에 균일하게 분산된 CNT 입자의 역할이 내삭마성을 증가시키는 결과를 확인하였다.
Malignant hilar biliary obstruction (MHO), an aggressive perihilar biliary obstruction caused by cholangiocarcinoma, gallbladder cancer, or other metastatic malignancies, has a poor prognosis. Surgical resection is the only curative treatment for biliary malignancies. However, the majority of patients with MHO cannot undergo surgery on presentation because of an advanced inoperable state or a poor performance state due to old age or comorbid diseases. Therefore, palliative biliary drainage is mandatory to improve symptomatic jaundice and the quality of life. Among the drainage methods, endoscopic biliary drainage is the current standard for palliation of unresectable advanced MHO. In addition, combined with endoscopic drainage, additional local ablation therapies, such as photodynamic therapy or radiofrequency ablation (RFA), have been introduced to prolong stent patency and survival. Currently, RFA is commonly used as palliative therapy, even for advanced MHO. This literature review summarizes recent studies on RFA for advanced MHO.
방사선차폐 laser ablation 시스템을 레이저, 미세영역의 영상 확인을 위한 이미지 시스템, XYZ 이동장치와 조절기, ablation chamber, manipulator 및 여러 가지 광학부품들로 구성하였다. Ablation용 레이저는 UOB 및 tircaloy 시편으로부터 효율적으로 시료를 채취할 수 있도록 266 nm(6 mJ)까지 파장 변환이 가능한 Nd:YAG 레이저를 선정하였으며, 이미지 시스템은 직경 50 $\mu$m 크기의 crater를 판별할 수 있는 200 배율 이상의 규격을 갖춘 CCD 카메라로 선정하였다. 시편 미세이동장치는 XYZ방향으로 시편이동이 가능하고 최대 이동거리가 50 mm까지 , 그리고 최소 1$\mu$m 씩 정확하게 움직일 수 있는 장치로 선정하였다. 구성된 각 단위기기들에 대하여 광학 정렬을 수행한 후, 시료채취 부위를 50 $\mu$m씩 정확하게 이동하면서 레이저로 조사시킨 시료 표면을 CCD 카메라를 통하여 관찰한 결과, 표면에 생성된 crater는 원형임을 확인함으로써 단위기기별 성능을 확인할 수 있었다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.