• 제목/요약/키워드: abdominal projection

Search Result 19, Processing Time 0.02 seconds

A new record of the subgenus Eusimulium Roubaud from Korea with an updated key to genera and subgenera of Korean black flies(Diptera: Simuliidae)

  • Kim, Sam-Kyu
    • Journal of Species Research
    • /
    • v.9 no.2
    • /
    • pp.174-179
    • /
    • 2020
  • Larvae and pupae of Simulium (Eusimulium) satsumense were collected and recorded from Korea for the first time. Detailed descriptions and photographs of both immatures are provided. Currently, 42 species are known from the subgenus Eusimulium, which is found globally, mainly in the Holarctic Region, but unknown from Korea. Members of the subgenus Eusimulium are morphologically homogeneous in male, female, and pupa, making them extremely difficult to distinguish from one another. S. (E.) satsumense can be distinguished from other Korean black flies by the following combination of the characteristics: Pupa: Gill of four slender filaments, dorsalmost filament strongly divergent from other filaments; cocoon slipper shaped without anterodorsal projection; Larva: Head spots distinctly positive; postgenal cleft short, apically rounded or squared; antenna with proximal segment brown; abdominal segments IX with prominent ventral tubercles; and rectal papillae of three simple lobes. In addition to descriptions for larvae and pupae of the species, a key to genera and subgenera of Simulium of Korean black flies are also provided.

A Study on the Architectural Planning of the Angiography Unit in General Hospital (종합병원 혈관조영촬영유니트의 건축계획에 관한 연구)

  • Yun, Woo-Yong;Chai, Choul-Gyun
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.12 no.2
    • /
    • pp.69-77
    • /
    • 2006
  • Angiography means that a check up to know an abnormal condition in all the blood vessels include from the heart, aortae, cerobrovascular and abdonominal artery to hands and feet. Main examples of this are cerebral angiography, abdominal, liver for urinary anomaly, renovascular angiography, and artery and vein in arms and legs. Angiography uses radial rays or angiography equipment for an image output during interventional procedure and compositive diagnosis. The acts which performed in a projection room have changed drastically. In general, it is performed by using equipment which is attached one or two C-arms and the method of inserting catheter in vein after anesthesia. For this reason, some rooms that consist of angiography room units should be planned not only for expensiveness equipment and facilities also to be germ-free. Nowadays, in the angiography unit case, it is placed independently as the central part of many hospitals. It does not belong to the imaging medical department any more as considering raising filming times and the relation between C.C.U.(coronary care unit) and operation unit. This means the acts performed are diversified and well-organized rooms in support of diagnosis are required. However, it is difficult to plan the angiography room unit due to domestic researches and data on this unit are not enough. Therefore, this study aims at bringing up basic issue for architectural planning of the angiography unit in general hospital.

  • PDF

A case of polypoid cystitis in a dog

  • Im, Eo-Jin;Kang, Sang-Chul;Jung, Ji-Youl;Jeon, Jae-Nam;Kim, Jae-Hoon
    • Korean Journal of Veterinary Research
    • /
    • v.49 no.2
    • /
    • pp.163-166
    • /
    • 2009
  • Among benign proliferation of the urinary bladder, polypoid cystitis is a rare disease in dogs. It is characterized by epithelial proliferation, chronic inflammation in lamina propria, and development of a polypoid mass or masses without evidence of neoplasia. This report describes histopathologic features of polypoid cystitis in dog. A 10-year-old spayed female shihtzu-dog was presented with two-month history of hematuria. Abdominal ultrasonography confirmed the thickened bladder wall and calculi in both kidneys. Surgical biopsy sample was taken from the thickened bladder mucosa for the histopathologic examination. The mass was covered with irregular hyperplastic transitional epithelium with the projection into the lumen in multifocal areas as well as many Brunn's nests in lamina propria. Many inflammatory cells such as lymphocyte, plasma cell, and macrophage and few neutrophils were occupied in lamina propria and submucosa. Proliferated fibrous tissues in lamina propria were clarified by using special staining methods. These collagens were stained blue with Masson's trichrome and red with van Gieson, but negative for alcian blue. Based on the clinical, gross, and histopathologic examinations, this case was diagnosed as polypoid cystitis in a dog. In our best knowledge, this is the first report of polypoid cystitis in dog in Korea.

Carcinoid tumor of gallbladder in a dog (개의 담낭에서 발생한 carcinoid tumor 증례 보고)

  • Woo, Sang-Ho;Go, Du-Min;Cheon, Doosung;Kim, Jae-Hoon;Choi, Gabchol;Oh, Ye-In;Kim, Dae-Yong
    • Korean Journal of Veterinary Research
    • /
    • v.60 no.2
    • /
    • pp.101-104
    • /
    • 2020
  • A 7-year-old female mixed-breed dog was presented to a veterinary clinic for pyometra. During abdominal ultrasonography, an abnormal finding was noted in the gallbladder. A cholecystectomy was performed. Grossly, the gallbladder wall was thickened with a polypoid nodular projection into the lumen. Microscopically, the polyp consisted of a solid sheet of round to polygonal-shaped cells that formed small packets with fibrovascular septa. The neoplastic cells contained abundant cytoplasmic eosinophilic granules. Immunohistochemically, the neoplastic cells were positive to chromogranin A and neuron-specific enolase, whereas they were negative to vimentin and cytokeratin. This case was diagnosed as a primary gallbladder carcinoid tumor.

Paraovarian Serous Borderline Tumor: A Case Report (난소위체에서 발생한 장액성 경계성 종양: 증례 보고)

  • Hwang, Eun Taeg;Kim, See Hyung;Kim, Mi Jeong;Kang, Yu Na
    • Journal of the Korean Society of Radiology
    • /
    • v.79 no.6
    • /
    • pp.337-339
    • /
    • 2018
  • Parovarian cyst is usually simple cyst, and accounts for 10%-20% of adnexal masses. Borderline or malignant parovarian tumor is rare, and it contains papillary projection at the smooth inner wall. We report the ultrasonography, CT and MRI findings of a parovarian serous borderline tumor in 19-year-old female presenting left lower quadrant abdominal discomfort for 2 days.

BUCCAL FAT PAD TRANSFER AS A PEDICLED FLAP FOR FACIAL AUGMENTATION (외상성 안면 함몰부에 협지방대 유경 피판을 사용한 재건술)

  • Chung, Sang-Chul;Ann, Heui-Yong;Choi, Hong-Sik;Um, In-Woong;Kim, Chang-Soo
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.13 no.2
    • /
    • pp.153-159
    • /
    • 1991
  • The use of the autogenous free fat is a well-known procedure to fill in superficial depressions resulting from the traumatic or congenital defects. The major donor site for this procedure was the abdominal subcutaneous fat or buttocks. In 1977, Egyedi was the first to report the use of the buccal fat pad as a pedicled graft. The buccal fat pad is a structure usually considered to be a nuisance when encountered in intraoral procedures such as facial bone osteotomies, elevation of buccal falp, or procedures on Stensen's duct. In these operations, appearance of the buccal fat pad complicates surgical exposure. The buccal fat pad is a lobulated convex mass of fatty tissue covered by a very delicate membrane, and is described as having a body from which four processes extend. These projection serve as a filling material between the various muscular structures in the area. Recently malar depression was augmented with the pedicled buccal fat pad in 3 cases, and it was used for the reconstruction of the nasolabial fold in one case.

  • PDF

A Study on the Slacks pattern for Pregnant Women - focused on slacks pattern for mid or second half period of puegency - (임산부용 슬랙스 패턴설계에 관한 연구 - 임신중기.말기의 기본 슬랙스 패턴설계를 중심으로 -)

  • Na, Mi-Hyang;Kim, Youen-Hee;Kim, Mi-Sun
    • Korean Journal of Human Ecology
    • /
    • v.9 no.4
    • /
    • pp.471-482
    • /
    • 2000
  • The purpose of this study is to produce slacks pattern for pregnant women in the mid or second half period of their pregnancy according to the development figure of the body shell from a follow-up measurement. We here would like to produce slacks pattern for pregnant women constructed to fit better with their individual property in their figure and to help maintain the shape and beauty of the lower half of body and would compare it with two manufactured slacks pattern. The results of the study were as follows; 1. As the pregnancy proceeds, the height of natural-waist line went up spontaneously due to the projection of abdominal region, therefore, it was given darts at the front zipper part so that they could maintain a nice figure and to avoid possibility of feeling oppressed. To acquire a slimmer outfit, we made of the slacks-bottom narrower than the width at the knee line, and it worked out. 2. Sensory evaluation for appearance: According to the statistical of the result of 19items on the questionaire, all items showed significant difference(a$\leq$0.01) between the new and A(bunka) B(Kim's pattern) method slacks pattern, with the new pattern having higher scores. The new drafting method proved to be better fitted, to fit the shape of bodies properly and to get a visual effect to look slim.

  • PDF

Comparison of Radiation Dose and Image Quality between the 2nd Generation and 3rd Generation DualSource Single-Energy and Dual-Source Dual-Energy CT of the Abdomen (2세대와 3세대 이중 소스 단일 에너지와 이중 소스 이중 에너지를 이용한 복부 컴퓨터단층촬영의 방사선량 및 영상 품질 비교)

  • Chang Gun Kim;See Hyung Kim;Seung Hyun Cho;Hun kyu Ryeom;Won Hwa Kim;Hye Jung Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.6
    • /
    • pp.1342-1353
    • /
    • 2022
  • Purpose We compared the radiation dose and image quality between the 2nd generation and the 3rd generation dual-source single-energy (DSSE) and dual-source dual-energy (DSDE) CT of the abdomen. Materials and Methods We included patients undergoing follow-up abdominal CT after partial or radical nephrectomy in the first 10 months of 2019 (2nd generation DS CT) and the first 10 months of 2020 (3rd generation DS CT). We divided the 320 patients into 4 groups (A, 2nd generation DSSE CT; B, 2nd generation DSDE CT; C, 3rd generation DSSE CT; and D, 3rd generation DSDE CT) (n = 80 each) matched by sex and body mass index. Radiation dose and image quality (objective and subjective qualities) were compared between the groups. Results The mean size-specific dose estimation of 3rd generation DSDE CT group was significantly lower than that of the 2nd generation DSSE CT (42.5%, p = 0.013) and 2nd generation DSDE CT (46.9%, p = 0.015) groups. Interobserver agreement was excellent for the overall image quality (intraclass correlation coefficient [ICC]: 0.8867) and image artifacts (ICC: 0.9423). Conclusion Our results showed a considerable reduction in the radiation dose while maintaining high image quality with 3rd generation DSDE CT as compared to the 2nd generation DSDE CT and 2nd generation DSSE CT.

Comparison of True and Virtual Non-Contrast Images of Liver Obtained with Single-Source Twin Beam and Dual-Source Dual-Energy CT (간의 단일선원 Twin Beam과 이중선원 이중에너지 전산화단층촬영의 비조영증강 영상과 가상 비조영증강 영상의 비교 연구)

  • Jeong Sub Lee;Guk Myung Choi;Bong Soo Kim;Su Yeon Ko;Kyung Ryeol Lee;Jeong Jae Kim;Doo Ri Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.1
    • /
    • pp.170-184
    • /
    • 2023
  • Purpose To assess the magnitude of differences between attenuation values of the true non-contrast image (TNC) and virtual non-contrast image (VNC) derived from twin-beam dual-energy CT (tbDECT) and dual-source DECT (dsDECT). Materials and Methods This retrospective study included 62 patients who underwent liver dynamic DECT with tbDECT (n = 32) or dsDECT (n = 30). Arterial VNC (AVNC), portal VNC (PVNC), and delayed VNC (DVNC) were reconstructed using multiphasic DECT. Attenuation values of multiple intra-abdominal organs (n = 11) on TNCs were subsequently compared to those on multiphasic VNCs. Further, we investigated the percentage of cases with an absolute difference between TNC and VNC of ≤ 10 Hounsfield units (HU). Results For the mean attenuation values of TNC and VNC, 33 items for each DECT were compared according to the multiphasic VNCs and organs. More than half of the comparison items for each DECT showed significant differences (tbDECT 17/33; dsDECT 19/33; Bonferroni correction p < 0.0167). The percentage of cases with an absolute difference ≤ 10 HU was 56.7%, 69.2%, and 78.6% in AVNC, PVNC, and DVNC in tbDECT, respectively, and 70.5%, 78%, and 78% in dsDECT, respectively. Conclusion VNCs derived from the two DECTs were insufficient to replace TNCs because of the considerable difference in attenuation values.