• Title/Summary/Keyword: abdominal muscles

Search Result 318, Processing Time 0.024 seconds

Effect of PNF Leg Pattern Application According to Posture on Muscle Activation of the Contralateral Gluteus and Transverse Abdominis: A Preliminary Study (자세변화에 따른 PNF 다리패턴 적용이 반대측 볼기근과 배가로근에 미치는 영향: 예비 연구)

  • Chae, Jung-Byung;Jung, Ju-Hyeon;Jung, Da-Eun
    • PNF and Movement
    • /
    • v.20 no.2
    • /
    • pp.285-293
    • /
    • 2022
  • Purpose: The purpose of this study was to confirm that the activation of the contralateral muscles changes according to posture after applying the proprioceptive neuromuscular facilitation leg pattern. Methods: Ten healthy adults (four males and six females) with no history of current musculoskeletal/neurological injuries were recruited for this study. Abdominal muscle (transverse abdominis) and hip joint muscle (gluteus maximus and gluteus medius) activation was assessed using surface electromyography (Ultium EMG, Noraxon Inc., USA). We evaluated muscle activation during the application of the PNF leg pattern. The data were analyzed using the SPSS version 21.0 program. Results: The results were found to be statistically significantly different in the 90/90 supine posture and sitting posture for the gluteus maximus (p < 0.05). The results were found to be not statistically significantly different for the transverse abdominis according to posture (p > 0.05). The results were found to be not statistically significantly different for the gluteus medius according to posture (p > 0.05). Conclusion: Application of the PNF leg pattern resulted in a significant change in the muscle activation of the contralateral segment according to posture, and the 90/90 supine posture induced high muscle activation of the gluteus maximus. In addition, the activation of the transverse abdominis was high in all three postures.

A study on Yang Shi Tai Chi Chuan in Bartenieff Fundamentals Perspectives (바티니에프 기본원리를 통해 본 양식 태극권에 관한 연구)

  • Wang, Zhiquan
    • Trans-
    • /
    • v.8
    • /
    • pp.95-127
    • /
    • 2020
  • This research is based on using Bartenieff Fundamentals to analyze the fundamentals of Tai Chi Chuan's movements in order to develop the methods of relaxation from Tai Chi Chuan's principle movement movements It also shows that the two techniques have commonalities in many ways. First of all, taking a philosophical approach on the body movements of Tai Chi Chuan and Bartenieff, for both methods the ultimate goal is the integration of mind and body. In other words, there is a thread of connection between the East's body and mind monism and the west's Body Awareness. Secondly, looking at it from a Breath Support standpoint as used in the Bartenieff method, the two methods both use the breathing to naturally move the body and relax the body. In Tai Chi Chuan the Breath is the basis of life and the strength of the Body. So the breathing of Tai Chi chuan is what makes body and mind communicate, harmonize and integrate. In other words, Breathing in Tai Chi is realized through mental fusion and affects the movements. This is the same as the Breath Support of Bartenieff. It is said that in every aspect the Breath Support of Bartenieff influences the movement and changes both the inner and outer form of the body. Thirdly, looking at the Core Support used in the Bartenieff method, both methods emphasize core. At the same time of moving and being conscious of one's core, the usage of muscles can be deeper rather than superficial and this enables strong and flexible movement. In Tai Chi Chuan abdominal muscles used when one coughs are consciously engaged through abdominal breathing and so strength is collected in the core. When one exercises like that the core becomes more stable and breathing becomes more smooth. Fourthly, analyzing the Rotary Factor used in the Bartenieff Fundamentals, they both use rotary movement to reach the goal of physical relaxation. The rotation factor of Bartenieff allows movement to be easier and more free because of the characteristic of joint exercise where the center axis moved in three dimensions, this is the same in Tai Chi chuan. According to Tai Chi chuan's circle and Spiral Movements, it can achieve the relaxation through switching into a seamless flow and access space as much as possible. Finally, when looking at Developmental Patterning through Bonnie Bainbridge Cohen's Body-Mind Centering Work theory, presented from Bartenieff developmental model are similar with the developmental process of Tai Chi chuan Breath, Core-Distal Connectivity/Navel Radiation, Head-Tail Connectivity/Spinal Movement, Upper-Lower Connectivity/Homologous, Body-Half Connectivity/Homo-Lateral Connectivity, Cross-Lateral Connectivity/Contra-Lateral Connectivity. They are all similar. In other words, in Tai Chi Chuan energy is gathered in the core through breathing, upper and lower body are connected through the spine, not only homo-laterally but also cross-laterally. Through this study the expression of the dance movements can be more natural. Additionally based on the Body Awareness balance usage of the central axis, joints and body can develop the relax technique.

  • PDF

The Change of The Effect on The Subcutaneous Fat Area and Visceral Fat Area by The Functional Electrical Stimulation and Aerobic Exercise (기능적 전기 자극과 유산소 운동이 복부비만의 피하지방과 내장지방에 미치는 효과)

  • Oh Sung-tae;Lee Mun-hwan;Park Rae-Joon
    • The Journal of Korean Physical Therapy
    • /
    • v.16 no.1
    • /
    • pp.85-123
    • /
    • 2004
  • Back ground : Subcutaneous fat area is the main factor involved in replacement disease and arteriosclerosis. Simple weight control is the appropriate medical treatment. It's understood that weight reduction does not only reduce the fat concentrations in blood but also reduces blood pressure, improves glucose levels in diabetes patients and reduces incidents of heart disease. there are several methods for reducing fat in the abdominal region but their effectiveness is not folly understood. one method is electrical stimulation of the problem areas. Method : From May 1st 2002 to October 31st. The 15 subjects who received medical examination were aged between 25 and 53 and were of mixed gender. The subjects were divided into two groups one to received functional electrical stimulation and the other a control group. Using Broca's criterion for judging fat grades. I analysed the differences between the two groups before and after the treatment. Subjects received functional electrical stimulation on the abdominal muscle intensity 50Hz. They received this treatment 4 days a week for 40 minutes a day. In the case of aerobic exercise, at the Treadmill, we used it with the intensity of $75\%$ maximum heart rate (220-age). Result 1)After functional electrical stimulation in the case of male subjects, the weight was reduced 1.93kg, obesity $2.60\%$, fat mass 2.73kg, Percent body fat $4.40\%$, waist circumference 6.53cm, circumference of hips 5.53cm. On the other side, the quality of muscle was increased at the rate of 1.03kg, but it's not attentional level. The subcutaneous fat area was reduced by $26.63cm^2$, the visceral fat area was reduced by $43.00cm^2$, In the female subjects, we can see the reduction of fat grade by $26.63cm^2$, the quantity of body fat by 1.5kg, percent body fat by $1.77\%$, circumference of waist by 4.02cm, circumference of hips by 3.67cm, weight by 1.40kg but was increased 0.72kg at the quantity of muscles. We can see the reduction also in the subcutaneous fat area $24.03cm^2$, the visceral fat area by $25.36cm^2$. 2)After aerobic exercise, on the male subjects, we can see reduction of weight by 3.36kg, obesity by $4.00\%$, fat mass by 2.83kg and we can see increase at the soft lean mass by 2.96kg, but we can see reduction, the percent body fat by $3.03\%$, fat distribution by $0.023\%$, circumference of waist by 3.10cm, circumference of hips by 2.23cm. The female subjects show a reduction in the weight by 2.48kg, percent body fat by $2.20\%$, show an increase in the soft lean mass by 1.54kg. We can see a reduction in the quantity of fat mass by 2.32kg, the percent body fat by $2.80\%$, the circumference of waist by 2.16cm, the circumference of hips by 2.68cm, the fat distribution by $0.016\%$, the subcutaneous fat area by $15.25cm^2$ the visceral fat area by $11.52cm^2$. After aerobic exercise, we can't see the attentional change at the total cholesterol, triglyceride, high density lipoprotein cholesterol, low density lipoprotein cholesterol. 3)After the application of functional electrical stimulation and aerobic exercise, in result of measurement on the body ingredient, we could see the weight reduction and increase the quantity of muscle with the male group who exercised aerobic. We can see the attentional rate on the electrical stimulation about abdominal fat rate, circumference of waist, circumference of hips. The other hand, I couldn't see the attentional differences between the two groups in the rate of fatness and quantity of body fat and the rate of body fat. There isn't any attentional difference in the area of fat under skin, on the contrary, There is attentional difference in the fat in the internal organs area at the electrical stimulation site. We can't see the attentional change of total cholesterol, triglyceride, high density lipoprotein cholesterol, low density lipoprotein cholesterol between electrical stimulation and aerobic exercise. 4)After execution of functional electrical stimulation and aerobic exercise, in result of measurement on change of body ingredient among female objects, We could see weight reduction, increase at muscle quantity in the aerobic exercise group. We could see the attentional differences in the rate of fatness, the rate of abdominal region, the circumference which received electrical stimulation. But, we couldn't see the attentional differences between two groups in the quantity of body fatness, the circumference of hips. The subcutaneous fat area doesn't show the attentional differences. On the Contrary, we could see lots of differences in the visceral fat area of the electrical stimulation group. Conclusion The results show that functional electrical stimulation and aerobic exercise have insignificant differences when if comes to total cholesterol, triglyceride, high density lipoprotein cholesterol, low density lipoprotein cholesterol. Though there is affirmative change in body ingredient after both electrical stimulation and aerobic exercise. Functional electrical stimulation is more effective on the subcutaneous fat area and in changing visceral fat area. There fore. It is concluded that the physical therapy is more effective in the treatment of abdominal fatness.

  • PDF

Comparative study on patterns and symptoms of disharmony(病機病症) between the internal organs(藏府) and external bodily form(身形) (藏府와 身形의 病機 및 病症에 대한 比較考察)

  • Baek, Sang-Ryong
    • Journal of Korean Medical classics
    • /
    • v.13 no.2 s.17
    • /
    • pp.21-21
    • /
    • 2000
  • All living things including human being consist of soul(spirit) and body. Soul is the root of a life and body frames it. I wrote this paper to tell how internal injury due to endogenous etiological factors and affection due to exegenous pathogenic factors, affect the internal organs and the external bodily from. This paper begins with description of the patterns of disharmony of the internal organs. General disorders of each Five-Jang(五藏) an be classified into two types of soul and body. The Liver and the Heart which lead changing to Yang(陽) of vital energy, have close relationship with spiritual symptoms because spirit is related to Yang. The Lung, Kidneys, the Spleen which lead changing to m(陰) of vital energy, mainly connected with physical disorders because body is relatively close to m. The Five-Jang are ruled by the Five-Phases(五行) system and cause troubles with Oche(五體) and the nine body orifice. Otherwise the main function of the Six-Bu(六府) is to receive food, absorb the usuable portions, and transmit and excrete waste. Therefore they can cause such problems as abdominal pain, distention, difficulty in urination, and constipation. The spleen is responsible for sending Grain-Ki)穀氣) 내 that is closely connected with the six-Bu. The Gall bladder takes care of control of giving out spirit. That's why it presents many symptoms related to the spirit that is ruled by the Five-Jang. Patterns of disharmony of external bodily form is influenced by the state of Maridians. Bodily forms get divided into many parts by the function of six-meridians(六經) to which they belong. Six-meridians have their own function related to excretion, related to excretion, retention, and balance(開闔樞). If local bodily froms get affected by pernicious influences, the Meridians to which they are attached will lose harmony and connot fulfil their own functions. Because the meridian symtem unifies all parts of the body, the whole body will be under the influence of the affection although local parts of the bodily forms get affected. Therefore the symptoms of disharmony should be considered in a synthetic view. There are however, also cases which should be focused on the very meridian channels affected. Disorder within a Meridian generates derangement in the pathway make it not to benefit the muscles and skin belong to it. Because the meridians connect the interior organs with the exterior bodily form, they are influenced by each other.

Comparative study on patterns and symptoms of disharmony(病機病症) between the internal organs(藏府) and external bodily form(身形) (장부(藏府)와 신형(身形)의 병기(病機) 및 병증(病症)에 대한 비교고찰(比較考察))

  • Baek, Sang-Ryong
    • Journal of Korean Medical classics
    • /
    • v.13 no.2 s.17
    • /
    • pp.22-42
    • /
    • 2000
  • All living things including human being consist of soul(spirit) and body. Soul is the root of a life and body frames it. I wrote this paper to tell how internal injury due to endogenous etiological factors and affection due to exogenous pathogenic factors, affect the internal organs and the external bodily from. This paper begins with description of the patterns of disharmony of the internal organs. General disorders of each Five-Jang(五藏) an be classified into two types of soul and body. The Liver and the Heart which lead changing to Yang(陽) of vital energy, have close relationship with spiritual symptoms because spirit is related to Yang. The Lung, Kidneys, the Spleen which lead changing to m(陰) of vital energy, mainly connected with physical disorders because body is relatively close to m. The Five-Jang are ruled by the Five-Phases(五行) system and cause troubles with Oche(五體) and the nine body orifice. Otherwise the main function of the Six-Bu(六府) is to receive food, absorb the usable portions, and transmit and excrete waste. Therefore they can cause such problems as abdominal pain, distention, difficulty in urination, and constipation. The spleen is responsible for sending Grain-Ki(穀氣) so that is closely connected with the six-Bu. The Gall bladder takes care of control of giving out spirit. That's why it presents many symptoms related to the spirit that is ruled by the Five-Jang. Patterns of disharmony of external bodily form is influenced by the state of Meridians. Bodily forms get divided into many parts by the function of six-meridians(六經) to which they belong. Six-meridians have their own function related to excretion, related to excretion, retention, and balance(開闔樞). If local bodily forms get affected by pernicious influences, the Meridians to which they are attached will lose harmony and cannot fulfil their own functions. Because the meridian system unifies all parts of the body, the whole body will be under the influence of the affection although local parts of the bodily forms get affected. Therefore the symptoms of disharmony should be considered in a synthetic view. There are however, also cases which should be focused on the very meridian channels affected. Disorder within a Meridian generates derangement in the pathway make it not to benefit the muscles and skin belong to it. Because the meridians connect the interior organs with the exterior bodily form, they are influenced by each other.

  • PDF

Angular Differences between the Lower Extremity and the Ground that Express Maximum Core Muscle Activation According to Core-strengthening Exercises

  • Son, Nam Jeong;Jun, Hyun Jeong;Yi, Kyung Ock
    • Korean Journal of Applied Biomechanics
    • /
    • v.27 no.4
    • /
    • pp.247-255
    • /
    • 2017
  • Objective: The purpose of this study was to investigate the maximum core muscle activation angle according to core-strengthening exercises. Method: Twenty-six young female football players (age: $17.84{\pm}0.80years$, height: $163.08{\pm}5.25cm$, weight: $54.96{\pm}7.41kg$) registered in the Korea Football Association from D High School located in Seoul were the subjects of this research. An electromyogram (Noraxon, USA) was used for monitoring the maximum core muscle contraction activity. Results: The angle for the maximum core muscle strength per core exercise and muscle was the smallest for the upper rectus abdominis in the windshield wiper exercise. The angle of the vastus medialis was significantly the largest. The range of angles at which the maximum strength was observed for each core exercise were as follows: 1) abdominal flutter kicks ($11{\sim}40^{\circ}$), 2) leg raises ($21{\sim}34^{\circ}$), 3) scissors ($45{\sim}66^{\circ}$), 4) knee to elbow sit-ups ($42{\sim}64^{\circ}$), 5) reverse crunches ($9{\sim}40^{\circ}$), 6) butt-ups ($24{\sim}32^{\circ}$), 7) V sit-ups ($5{\sim}24^{\circ}$), 8) windshield wipers ($11{\sim}20^{\circ}$), 9) bird dog ($11{\sim}18^{\circ}$), and 10) raised leg plank ($38{\sim}50^{\circ}$). Conclusion: Four kinds of motion could be classified according to the range of angles at which the core muscles were maximally activated. The first group involves the range of motion that gives the maximum muscle strength when the lower extremity and ground angle was between $5^{\circ}$ and $24^{\circ}$, such as the V sit-ups, windshield wipers, and bird dog. The second group comprised the flutter kicks and reverse crunches at an angle between $9^{\circ}$ and $40^{\circ}$. The third group comprised the leg raise and butt-up exercises at an angle between $21^{\circ}$ and $34^{\circ}$. The fourth group included the scissors, knee to elbow sit-ups, and raised leg plank at an angle between $38^{\circ}$ and $66^{\circ}$. These results may be useful as basic data for core movement and core muscle training according to the purpose of exercise.

Examination of the Applications of Semen Persicae and Flos Carthami in the herbal Perscriptions Appeared in the book of ${\ulcorner}$Donguibogam${\lrcorner}$ according to Hyungsang Medicine (("동의보감"에서 도인 홍화 (桃仁 紅花)를 사용한 처방에 대한 형상의학적 고찰)

  • Kang, Kyung-Hwa;Lee, Yong-Tae
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.20 no.6
    • /
    • pp.1431-1441
    • /
    • 2006
  • Following conclusions were drawn from the examination of the usage of semen persicae and fols carthami from the view of Hyungsang Medicine. Semen persicae is used to vitalize the blood flow and eliminate the blood stagnation of the whole body in ${\ulcorner}$Donguibogam${\lrcorner}$, and therefor it is used for the blood flow of the heptal meridian and sometimes the intestinal meridian. Flos carthami is applied to vitalize the blood flow, remove obstructions in meridians, eliminate the blood stagnations, and stop the pain in ${\ulcorner}$Donguibogam${\lrcorner}$, therefore used in such symptoms of blood flow of the heptal meridian as amenorrhea, spasm of muscles, and coldness of the genitals. Also is applied in those cases of exhaustion, perspiration, and in digestive remedies which belong to the symptoms of cardiac blood flow. And it is used for dryness of the skin in which case the blood should be developed and malaria for the elimination of the blood stagnation and production of new blood. The combination of semen persicae and flos carthami is applied to eliminate the blood stagnation and stimulate menstrual discharge in uterus, as well as in the cases of lumbago and stomachache due to blood stagnation, blood stasis, mass in the abdomen, and abdominal distention. This combination is also used for the eyes, ears, numbness, and paralysis of hands and feet for the purpose of making the flow of the meridian smooth, and for diabetes, dryness of the skin, malaria, anal itching and pain for the purpose of eliminating the mass and renewing the tissues. The combination is diversly used in the book of ${\ulcorner}$Special lectures on clinical cases${\lrcorner}$ for the aftereffects of traffic accident, constipation, diabetes, dryness of the skin, paralysis of hands and feet, numbness of finger of hand and foot, and especially used frequently with prescription of Yijintang and Samultang combined in the cases of numbness. The prescription is used in Hyungsang medicine when the uterus, the external appearance(axis), hands and feet, heart, and the stomach is not good for the vitalization of the flow of the 12 meridians. It was though difficult to find extinguishing differences between the two herbs in the clinical cases applied in the book of ${\ulcorner}$Special lectures on clinical cases${\lrcorner}$.

Effects of Transcutaneous Electrical Stimulation on Physiological Symptoms and Psychological Satisfaction in Women With Stress Urinary Incontinence: A Preliminary Study

  • Kim, Ji-hyun;Kwon, Oh-yun;Jeon, Hye-seon;Hwang, Ui-jae;Gwak, Kyeong-tae;Yoon, Hyeo-bin;Park, Eun-young
    • Physical Therapy Korea
    • /
    • v.26 no.3
    • /
    • pp.67-75
    • /
    • 2019
  • Background: Stress urinary incontinence (SUI) is an involuntary leakage of urine from the urethra when intra-abdominal pressure increases, such as from sneezing, coughing, or physical exertion. It is caused by insufficient strength of the pelvic floor and sphincter muscles, resulting from vaginal delivery, obesity, hard physical work, or aging. The pelvic floor electrical stimulator is a conservative treatment generally used to relieve the symptoms of urinary incontinence. it recommended to applied before surgery is performed. Objects: The purpose of this study was to determine if the transcutaneous electrical stimulation (TCES) would be effective for the physiological symptoms and psychological satisfaction of women with SUI for an 8-weeks intervention. Methods: Easy-K is a specially designed user-friendly TCES. Five female who were diagnosed with SUI by a gynecologist but who did not require surgical intervention were included in this study. Intervention was implemented over an 8-week period. Outcome measures included vaginal ultrasonography, Levator ani muscle (LAM) contraction strength, incontinence quality of life (I-QOL), and female sexual function index (FSFI) questionnaires. Results: The bladder neck position significantly decreased across assessment time. Funneling index and urethral width significantly decreased after 8 weeks of intervention (p<.05). The bladder necksymphyseal distance and posterior rhabdosphincter thickness statistically increased and the anterior rhabdosphincter thickness showed a tendency to increase. All participants demonstrated a significant increase in the LAM contraction score across three assessment times (p<.05). Although the total score of the I-QOL did not show significant improvement, it steadily increased and among I-QOL subscales, only the "avoidance" subscale showed statistical improvements (p<.05). The total score of the FSFI statistically improved and the "desire" score significantly changed (p<.05). Conclusion: The TCES is recommended for women who want to apply conservative treatments before surgery and who have suffered from SUI in aspects of sexual function and quality of life.

Association of waist circumference with muscle and fat mass in adults with a normal body mass index

  • Lee, Gyeongsil;Choi, Seulggie;Park, Sang Min
    • Nutrition Research and Practice
    • /
    • v.15 no.5
    • /
    • pp.604-612
    • /
    • 2021
  • BACKGROUND/OBJECTIVES: We aimed to investigate the association of waist circumference (WC) with body composition among individuals with a normal body mass index (BMI) to distinguish muscle and fat mass, as both affect health differently. SUBJECTS/METHODS: We analyzed dual-energy X-ray absorptiometry data (derived from the Korean National Health and Nutrition Survey, which includes information on fat and lean mass) of 7,493 adults with a normal BMI. Subjects were categorized into four groups of increasing WC. The fourth group was defined as being centrally obese. Each number of subjects are as follows: 1,870, 695, 231, and 39 among men and 3,054, 1,100, 406, and 98 among women. We conducted a sex-stratified linear regression analysis of body composition according to WC group after adjustments for covariates. RESULTS: We observed a positive association of body fat with increasing WC in both men and women (all P for trend: < 0.001). The adjusted mean values for percent body fat with 95% confidence intervals (CIs) according to the four WC groups in ascending order were 17.8 (17.5-18.3), 21.0 (20.6-21.5), 22.1 (21.5-22.8), and 25.1 (24.2-26.1) in men and 29.7 (29.4-30.0), 32.0 (31.6-32.3), 32.9 (32.4-33.4), and 34.7 (33.2-36.1) in women. However, there was an inverted J-shaped association between muscle mass and WC. The fourth group had a higher percent body fat and lower muscle mass than other groups. The adjusted mean values for appendicular skeletal muscle mass index (kg/m2) with 95% CIs according to the four WC groups in ascending order were 7.55 (7.51-7.59), 7.62 (7.56-7.68), 7.65 (7.56-7.74), and 7.22 (7.04-7.41) in men and 5.83 (5.80-5.85), 5.96 (5.92-6.00), 6.03 (5.96-6.10), and 5.88 (5.73-6.03). CONCLUSIONS: There was a positive association between body fat and WC among individuals with normal BMI; conversely there was an inverted J-shaped association between lean body mass and WC. Our findings support the WC measurement should be included in obesity evaluations for adults with a normal BMI.

The Effect of Applying Various Tools to the Stiffness and Muscle Tone of Hamstring Muscles (다양한 도구의 적용이 뒤넙다리근의 뻣뻣함과 근 긴장도에 미치는 영향)

  • Hwang, Sunghyun;Kim, Taeho
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.8 no.4
    • /
    • pp.223-230
    • /
    • 2020
  • Purpose : The purpose of this study was to examine the effects of tools (i., extracorporeal shock wave therapy, massage gun, and foam roller) on range of motion, muscle tone and pain threshold among patients with hamstring stiffness. Methods : Fourteen participants with hamstrings stiffness were recruited. Interventions were performed 6 times, and each session was for 30 seconds using the three tools. The range of motion, muscle tone, and pain threshold were measured. The order of the use of the three tools was randomly determined. The foam roller was made to move from the bottom of the hip crease to the upper part of the back of the hamstring. Additionally, velocity 5 vibration stimulation was performed on the hamstring using a massage gun. Moreover, vibration stimulation was performed on the hamstring with extracorporeal shock wave therapy 5 minutes, 5 Hz, and 1,500 strokes. The flexibility of the posterior thigh muscle was based on maintaining the knee and hip joints in a 90 ° bend in the supine position. The joint angle of the knee was measured, when the knee was actively extended, at the maximum point where the posterior thigh muscle was stretched. The elasticity of the posterior thigh muscle was measured while the subject was prone and in a relaxed state without any force. Measurements were made at the muscle abdominal area of the semitendinosus muscle of the posterior femur, and the area to be measured was marked with a pen. The measurement of the tenderness threshold of the posterior femur was measured using a tenderness meter(Commander Algometer, J-Tech, USA). The force value at the point at which the pressure sensation change to pain was measured after applying vertical pressure to the posterior femur muscle, which was the halfway point between the ischial tuberosity and the popliteal surface of the subject lying on their stomach. Results : The extracorporeal shock wave therapy increased stiffness and, muscle tone, and caused changes in the pain threshold, whereas the other two tools had no effect on these indices. Conclusion : Extracorporeal shock wave therapy has important effects on range of motion and muscle stiffness and can be used in warmup protocols.