• 제목/요약/키워드: abdominal muscles

검색결과 318건 처리시간 0.021초

외복사근과 다열근에 대한 초음파 영상과 표면 근전도 측정방법의 신뢰도와 타당도 (Reliability and Validity of Ultrasound Imaging and sEMG Measurement to External Abdominal Oblique and Lumbar Multifidus Muscles)

  • 김창용;최종덕;김선엽;오덕원;김진경
    • 한국전문물리치료학회지
    • /
    • 제18권1호
    • /
    • pp.37-46
    • /
    • 2011
  • The purpose of this study was to investigate intra-rater reliability and determine the validity of electromyography (EMG) measurements to represent muscle activity and ultrasonography (US) to represent muscle thickness during manual muscle testing (MMT) to external abdominal oblique (EO) and lumbar multifidus (MF). Twenty healthy subjects were recruited for this study and asked to perform MMT at differing levels. The subjects' muscle activity using EMG was measured by a ratio to maximum voluntary contraction (MVC) and root mean square (RMS) methods. The subjects' muscle thickness using US was measured by raw muscle thickness and change ratio of thickness to maximum (MVC) or resting condition. In three trials, measurements were performed on each subject by one examiner. The intra-rater reliability of measurements of EMG and US to EO and MF was calculated using intra-class coefficients. The intra-rater reliability of all measurements was excellent (ICC=.75~.98) in EMG and US. The conduct validity was calculated by one-way ANOVA with repeated measurements to compare whether the EMG and US measurements were different between MMT at different levels. There was only a significant difference between all grades at %MVC thickness measurement of US. These results suggest that a %MVC thickness measurement of US was a more sensitive and discriminate in all manual muscle testing grades. This information will be useful for the selection of US measurement and analysis methods in clinics.

혈관 수축성에 대한 phenylephrine, isoprenaline 및 prazosin의 융합성 조절 효과 (The convergence effect of phenylephrine, isoprenaline and prazosin on vascular contractility)

  • 제현동;민영실
    • 융합정보논문지
    • /
    • 제12권4호
    • /
    • pp.119-125
    • /
    • 2022
  • 심혈관계 활성이 예측되는 phenylephrine, isoprenaline, prazosin의 단독 및 병용 투여에서 혈관수축 억제능을 관찰하였고 아직 보고가 빈약한 수축성 조절 기전에 대해 조직 선택적 조절 가설을 세워서 조사하였다. 내피가 손상된 혈관을 수조내에 현수시켰고 혈관에 의한 기계적 신호가 등장력 변환기에서 전기적 신호로 변환되어 생리측정기에 표시되었다. 내피가 손상된 혈관에서 phenylephrine은 조직에 비선택적으로 지속적인 수축을 유지하였고 phenylephrine과 병용된 isoprenaline은 등척성 수축 실험에서 흉부, 복부 대동맥 등 조직에 비선택적으로 평활근에 대한 직접 작용으로 수축성을 일시적으로 감소시켰고 phenylephrine과 병용된 prazosin은 조직에 비선택적으로 평활근에 대한 직접 작용으로 수축성을 지속적으로 감소시켰다. 따라서 일부 조직에서 adrenergic beta receptor 밀도가 감소되거나 수용체 결합력이 감소되거나 수용체 결합 후 신호전달이 감소되거나 약물의 분포가 감소되어 isoprenaline이 phenylephrine의 지속적 작용에 대해 일시적으로 억제하고 prazosin이 지속적으로 억제하는 것으로 생각된다.

Comparisons of Trunk Muscle Activity During Arm Lift in Prone and Standing Positions With and Without Abdominal Drawing-in Maneuver

  • Kim, Ki-Song;Lim, One-Bin;Yi, Chung-Hwi;Cynn, Heon-Seock
    • 한국전문물리치료학회지
    • /
    • 제19권4호
    • /
    • pp.38-45
    • /
    • 2012
  • The aim of this study is to compare the effect of abdominal drawing-in maneuver (ADIM) on lower trapezius (LT), serratus anterior (SA), and erector spinae (ES) muscle activity during arm lifts in prone and standing positions. Twenty healthy subjects were recruited, and NoraxonTeleMyo 2400T was used to collect electromyographic signals from the LT, SA, and ES muscles. A two-way repeated analysis of variance (ANOVA) used a significance level of .05. If a significant interaction was found, pairwise comparisons were performed with a Bonferroni adjustment (.05/4=.013). The results of the study were as follows: 1) In LT, no significant ADIM by position interaction was found ($F_{1,19}$=.356, p=.558). There was a significant main effect for ADIM. LT muscle activity with ADIM was significantly greater compared with muscle activity without ADIM ($F_{1,19}$=82.863, p<.001). There was also a significant main effect for position. LT muscle activity in the prone position was greater compared with muscle activity in the standing position ($F_{1,19}$=116.401, p<.001). 2) In SA, significant ADIM by position interaction was found ($F_{1,19}$=8.687, p=.008). There were significant differences in all pairwise comparisons. The greatest SA muscle activity was observed in the standing position with ADIM. 3) In ES, significant ADIM by position interaction was found ($F_{1,19}$=122.473, p<.001). The lowest ES muscle activity was elicited in the standing position with ADIM. Based on these results, ADIM is advocated in the prone position to increase LT muscle activity. In addition, it is concluded that arm lifts in the standing position with ADIM offer the most favorable combination for reducing ES muscle activity and increasing SA muscle activity.

지지면 차이에 따른 안정화 운동 시 몸통의 근활성도에 미치는 효과 (Effect of Different Supporting Surfaces on Trunk Muscle Activities during Core Stabilization Exercises)

  • 장정훈;양승훈;강경두;김중근;박혜영;민주리;박혁수;박형은;김현정;박소연;김하정;한상완
    • 대한임상전기생리학회지
    • /
    • 제9권2호
    • /
    • pp.31-38
    • /
    • 2011
  • Purpose : The purpose of this study was to compare the effects of different supporting surfaces on trunk muscle activities during core stabilization exercises. Methods : A total of 20 healthy college students participated in this study for 6 weeks. In this study, we divided participants into a stable surface exercise group and an unstable surface exercise group. Each group performed core stabilization exercises of Curl-ups, Bridges, and Quadrupedal position. Core stabilization exercises were performed 3 times a week for 30 minutes during 6 weeks. The stable surface exercise group used a yoga mat while the unstable surface exercise group used AERO step. This study was designed using pre-test and post-test measurements. We used Surface Electromyograpy (sEMG) to measure for the rectus abdominis, external abdominal oblique, and multifidus muscle of trunk muscle activities. Data was processed using a paired sample t-test on SPSS 18.0. Results : For the stable surface exercise group there was a meaningful improvement in left rectus abdominis, left external abdominal oblique, and right multifidus (p<0.05). For the unstable surface exercise group, a meaningful improvement was seen in the left external abdominal oblique and right multifidus. Conclusion : From the experiment, we concluded that differences in surface can make various degrees of improvement in muscles activities, which suggests patients can choose a better option under their own conditions when planning to have a core stability exercise.

교각운동시 이마면에서 엉덩관절 위치가 배근육 근활성도에 미치는 영향 (Effect of hip positions in frontal plane on abdominal muscle activities during bridging exercise)

  • 이원휘
    • 한국산학기술학회논문지
    • /
    • 제20권3호
    • /
    • pp.224-230
    • /
    • 2019
  • 본 연구의 목적은 이마면에서 엉덩관절 위치에 따라 배근육들의 근활성도를 측정하여 비교함으로 이마면에서 엉덩관절의 위치가 배근육들의 근활성도에 영향을 미치는지 알아보는 것이다. 연구방법은 20대의 건강한 남녀 26명을 대상으로 엉덩관절 중립, 모음, 그리고 벌림 자세에 따라 교각운동을 하였을 때 표면 근전도 장비를 이용하여 양쪽 배곧은근과 배바깥빗근, 배속빗근의 근활성도를 비교하였다. 통계 방법은 반복측정 일요인 분산분석을 실시하였고, 유의수준은 0.05로 하였다. 연구 결과 배바깥빗근과 배속빗근은 이마면에서 엉덩관절 위치에 따라 유의한 차이가 있었고, 배곧은근은 유의한 차이가 없었다. 양쪽 배바깥빗근과 왼쪽 배속빗근은 엉덩관절 중립자세보다 엉덩관절 모음 자세에서 근활성도가 유의하게 증가하였으며 오른쪽 배속빗근은 엉덩관절 벌림 자세보다 엉덩관절 모음 자세에서 근활성도가 유의하게 증가하였다. 본 연구를 통해 엉덩관절 모음 자세가 다른 자세들에 비해 안정화 운동에 더욱 효과적일 수 있다는 것을 알 수 있었고, 안정화 운동 프로그램을 고안할 때 운동의 강도를 조절하기 위해 이마면에서 엉덩관절의 위치에 대한 요소를 적용할 수 있을 것이다.

Development and Validation of a Deep Learning System for Segmentation of Abdominal Muscle and Fat on Computed Tomography

  • Hyo Jung Park;Yongbin Shin;Jisuk Park;Hyosang Kim;In Seob Lee;Dong-Woo Seo;Jimi Huh;Tae Young Lee;TaeYong Park;Jeongjin Lee;Kyung Won Kim
    • Korean Journal of Radiology
    • /
    • 제21권1호
    • /
    • pp.88-100
    • /
    • 2020
  • Objective: We aimed to develop and validate a deep learning system for fully automated segmentation of abdominal muscle and fat areas on computed tomography (CT) images. Materials and Methods: A fully convolutional network-based segmentation system was developed using a training dataset of 883 CT scans from 467 subjects. Axial CT images obtained at the inferior endplate level of the 3rd lumbar vertebra were used for the analysis. Manually drawn segmentation maps of the skeletal muscle, visceral fat, and subcutaneous fat were created to serve as ground truth data. The performance of the fully convolutional network-based segmentation system was evaluated using the Dice similarity coefficient and cross-sectional area error, for both a separate internal validation dataset (426 CT scans from 308 subjects) and an external validation dataset (171 CT scans from 171 subjects from two outside hospitals). Results: The mean Dice similarity coefficients for muscle, subcutaneous fat, and visceral fat were high for both the internal (0.96, 0.97, and 0.97, respectively) and external (0.97, 0.97, and 0.97, respectively) validation datasets, while the mean cross-sectional area errors for muscle, subcutaneous fat, and visceral fat were low for both internal (2.1%, 3.8%, and 1.8%, respectively) and external (2.7%, 4.6%, and 2.3%, respectively) validation datasets. Conclusion: The fully convolutional network-based segmentation system exhibited high performance and accuracy in the automatic segmentation of abdominal muscle and fat on CT images.

Activation and Onset Time of the Gluteus Maximus Muscle during Three Different Prone Table Hip Extension Exercises

  • Jeon, In-Cheol
    • The Journal of Korean Physical Therapy
    • /
    • 제32권5호
    • /
    • pp.295-301
    • /
    • 2020
  • Purpose: The purpose of this study was to compare the electromyographic activity and onset time of the gluteus maximus (GM) and hamstring (HAM), lumbopelvic kinematics during three different prone table hip extension exercises in healthy individuals. Methods: Twenty subjects were participated. Electromyography device was used to measure the muscle activities and onset time of the GM and HAM muscles. An electromagnetic tracking motion device was used to measure lumbopelvic compensations. The subjects were asked to perform three different prone table hip extension [Prone table hip extension with the abdominal drawing-in maneuver on a chair (PTHEA), PTHEA with the ipsilateral knee flexion (PTHEAF), PTHEAF with hip 30 abduction (PTHEAFA)]. One-way repeated measures analysis of the variance and a Bonferroni post hoc test were used. Results: The electromyographic activity and onset time were significantly different among three conditions (PTHEA vs. PTHEAF vs. PTHEAFA)(p<0.01). The GM muscle activity and onset time were significantly greater and reduced during the PTHEAFA compared to PTHEA and PTHEAF (p<0.01). However, The HAM muscle activity and onset time were significantly smaller and delayed during the PTHEAFA compared to PTHEA and PTHEAF (p<0.01). Conclusions: PTHEAFA exercise can be recommended to facilitate the muscle activity and efficient muscle firing time of GM without HAM dominance.

Extraintestinal Migration of Centrorhynchus sp. (Acanthocephala: Centrorhynchidae) in Experimentally Infected Rats

  • Choi, Chang-Jin;Lee, Hye-Jung;Go, Jai-Hyang;Park, Yun-Kyu;Chai, Jong-Yil;Seo, Min
    • Parasites, Hosts and Diseases
    • /
    • 제48권2호
    • /
    • pp.139-143
    • /
    • 2010
  • Reptiles were known to serve as paratenic hosts for Centrorhynchus (Acanthocephala: Centrorhynchidae) in Korea, but the infection course in experimental animals was not elucidated yet. In this study, the tiger keelback snakes (Rhabdophis tigrinus) were collected and digested with artificial pepsin solution, and the larvae of Centrorhynchus were recovered from them. Then, the collected larvae were orally infected to rats for developmental observations. In rats, all the larvae were observed outside the intestine on day 3 post-infection (PI), including the mesentery and abdominal muscles. As for the development in rats, the ovary of Centrorhynchus sp. was observed at day 15 PI, and the cement glands were 3 in number. Based on the morphological characteristics, including the arrangement of proboscis hooks, these larvae proved to be a species of Centrorhynchus, and more studies were needed for species identification.

A Case of Coenurosis in a Wild Rabbit (Lepus sinensis) Caused by Taenia serialis Metacestode in Qinghai Tibetan Plateau Area, China

  • Zhang, Xue-Yong;Jian, Ying-Na;Ma, Li-Qing;Li, Xiu-Ping;Karanis, Panagiotis
    • Parasites, Hosts and Diseases
    • /
    • 제56권2호
    • /
    • pp.195-198
    • /
    • 2018
  • Six cystic metacestodes were found in the abdominal muscles of a wild rabbit, Lepus sinensis, in China. The coenurus contained one or more scolices armed with hooklets. Mitochondrial cox1 (1,623 bp) confirmed 98% homology with cox1 of Taenia serialis. This is the first report of T. serialis infection in an intermediate host in the Qinghai Tibetan Plateau Area, China.

개흉술 후 발생한 종격동염의 대흉근-복직근 양경근피판을 이용한 치료 (Pectoralis Major-Rectus Abdominis Bipedicle Muscle Flap in Treatment of Postoperative Mediastinitis)

  • 김범진;이원재;탁관철
    • Archives of Plastic Surgery
    • /
    • 제32권4호
    • /
    • pp.421-427
    • /
    • 2005
  • Although the incidence of mediastinal wound infection in patient undergoing median sternotomy for cardiovascular surgery is relatively low(less than 1%), it is not only a devastating and potentially life-threatening complication but also associated morbidity, mortality and cost are unacceptably high. During the past few decades various methods had been applied for the treatment of postoperative mediastinitis. Currently, chest wall reconstruction by using muscle flaps-especially pectoralis major muscle and rectus abdominis muscle are commonly selected for the reconstruction after wide debridement has become widely accepted. We performed bilateral pectoralis major-rectus abdominis muscles in-continuity bipedicle flap to overcome the limit of each flap for reconstruction of sternal defects in 17 patients. We analyzed the results of the surgery. Recurrent infection developed in 17.6% of cases and abdominal herniation was observed in one patient. There was no postoperative hematoma or death. We conclude that this flap is very valuable in reconstruction of the anterior chest wall defect caused by post-sternotomy infection because it provides sufficient volume to fill the entire mediastinum, and the complication rate compares favorably to that of other methods.