• Title/Summary/Keyword: a optical sensor

Search Result 1,790, Processing Time 0.029 seconds

Development of optical dual-sensors for submersion monitoring using zigbee-based wireless sensor networks (지그비 기반 센서 네트워크를 이용한 침수감지용 광 이중센서 개발)

  • Key, Kwang-Hyun;Kim, Hyung-Pyo;Sohn, Kyung-Rak
    • Journal of Sensor Science and Technology
    • /
    • v.19 no.3
    • /
    • pp.184-190
    • /
    • 2010
  • In this paper, a remote submersion warning system based on multi-mode optical fiber(MMF) sensors and a wireless sensor network(WSN) are proposed. To improve the reliability and stability of the sensors, the dual optical fiber sensors combined to the optical coupler are demonstrated. A slave zigbee as a wireless sensor module was used as a platform to monitor and record the signal from the MMF sensors and then transmits these information to a master zigbee wirelessly. The monitoring system running the $LabVIEW^{(R)}$ software was connected to the internet to support the short message service(SMS) through extensible markup language(XML) web service. No matter where the managers are, they can always receive the real-time remote-monitoring data for safety check.

Online Strain Measurement at Multiple Points on a Rotating Blade with Fiber Bragg Grating Sensors and a Rotary Optical Coupler (광섬유 격자 센서와 회전 광학 커플러를 사용한 회전하는 블레이드 여러 지점에서의 온라인 변형률 측정)

  • Lee, Jong-Min;Hwang, Yo-Ha
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.32 no.1
    • /
    • pp.77-82
    • /
    • 2008
  • Strain-gauges have been dominantly used to measure strain at various points on a rotor, however, either a slip ring or telemetry has to be used to send sensor signals to data acquisition instruments at stationary side. Both slip ring and telemetry have numerous inherent problems which force severe limitations in real applications. This paper introduces a new rotor condition monitoring system using FBG(Fiber Bragg Grating) sensors and a rotary optical coupler. A single optical fiber with many FBG sensors is installed on the rotor and an optical dynamic interrogator is installed at stationary side. The sensor signal connection between rotating part and stationary part is made by the rotary optical coupling method which makes use of light's unique characteristic-light travels through space. Broad band light source from the interrogator travels to the optical fiber on the rotor and reflected FBG sensor signals travel back to the optical fiber on stationary side and are connected to the interrogator. Rotary optical coupler's insertion loss change due to rotation is compensated by using a reference sensor installed at the center of the rotor. The proposed system's performance has been successfully demonstrated by accurately measuring strains at 5 points on a blade rotating at high speed.

PLC Optical Sensor for Contamination Monitoring on the Flow-Cell in the Water Quality Measurement System (수질 측정용 플로우 셀의 오염 모니터링을 위한 평면광도파로 센서)

  • Han, Seung Heon;Kim, Tae Un;Jung, Haeng Yun;Ki, Hyun Chul;Kim, Doo Gun;Kim, Seon Hoon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.32 no.6
    • /
    • pp.472-476
    • /
    • 2019
  • We have proposed a novel planar lightwave circuit (PLC) optical sensor to monitor the contamination in a flow-cell where water is continuously supplied through a water quality measurement system. We designed a PLC chip with a V-shape waveguide and the simulated its function as a sensor for monitoring contamination in a flow-cell using a numerical the FDTD (finite-difference time-domain) analysis. A novel cross type of waveguide was introduced to make the PLC chip of the V-shaped waveguide. The fabricated PLC was cut into the cross waveguide. A change in the optical propagation loss of the PLC sensor was observed after immersing the PLC sensor into city water. It was determined that the propagation loss of the PLC sensor was 3 dB at a wavelength of $1.55{\mu}m$ in the city water for 15 days.

Fiber-Optic Distributed Overheating Detection Sensor Using an Optical Time Domain Refrectometry (광시간영역 반사계를 이용한 분포형 광섬유 과열 감지 센서)

  • Kim, Dae Hyun;Kim, Kwang Taek
    • Journal of Sensor Science and Technology
    • /
    • v.22 no.4
    • /
    • pp.297-301
    • /
    • 2013
  • We proposed and demonstrated a distributed fiber-optic overheating detection sensor using optical time domain refrectometry. With increased of temperature the optical fiber is bended by a bi-metal and it result in optical leaky loss of the fiber. The sensor structure is designed in such a way that the signal of overheating is happen when the temperature exceeding a threshold temperature and the optical fiber is protected from excess bending.

A Study on the Parameter Analysis for High Precision Optical Current Sensor Implementation (고정도 광 전류센서 구현을 위한 파라미터 분석 연구)

  • Kim, Young-Soo;Lim, Young-Hoon;Hyun, Duck-Hwa
    • Proceedings of the KIEE Conference
    • /
    • 2001.11a
    • /
    • pp.265-267
    • /
    • 2001
  • In this paper, some optical parameters which have effects on the measuring precision and sensitivity of optical current sensor are analyzed. Each parameter occurs changes of specific characteristics of optical sensor system. The influences of performance and characteristics variation of optical current sensor are described in accordance with the changes of optical output power, optical bias point which is called phase difference, and a specific constant related to sensor material and wavelength of light source.

  • PDF

Smart Optical Fingerprint Sensor for Robust Fake Fingerprint Detection

  • Baek, Young-Hyun
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.6 no.2
    • /
    • pp.71-75
    • /
    • 2017
  • In this paper, a smart optical fingerprint sensor technology that is robust against faked fingerprints. A new lens and prism accurately detect fingerprint ridges and valleys that are needed to express a fingerprint's intrinsic characteristics well. The proposed technology includes light path configuration and an optical fingerprint sensor that can effectively identify faked fingerprint features. Results of simulation show the smart optical fingerprint sensor classifies the characteristics of faked fingerprints made from silicone, gelatin, paper, and rubber, and show that the proposed technology has superior detection performance with faked fingerprints, compared to the existing infrared discrimination method.

Continuous deformation measurement for track based on distributed optical fiber sensor

  • He, Jianping;Li, Peigang;Zhang, Shihai
    • Structural Monitoring and Maintenance
    • /
    • v.7 no.1
    • /
    • pp.1-12
    • /
    • 2020
  • Railway tracks are the direct supporting structures of the trains, which are vulnerable to produce large deformation under the temperature stress or subgrade settlement. The health status of track is critical, and the track should be routinely monitored to improve safety, lower the risk of excess deformation and provide reliable maintenance strategy. In this paper, the distributed optical fiber sensor was proposed to monitor the continuous deformation of the track. In order to validate the feasibility of the monitoring method, two deformation monitoring tests on one steel rail model in laboratory and on one real railway tack in outdoor were conducted respectively. In the model test, the working conditions of simply supported beam and continuous beam in the rail model under several concentrated loads were set to simulate different stress conditions of the real rail, respectively. In order to evaluate the monitoring accuracy, one distributed optical fiber sensor and one fiber Bragg grating (FBG) sensor were installed on the lower surface of the rail model, the strain measured by FBG sensor and the strain calculated from FEA were taken as measurement references. The model test results show that the strain measured by distributed optical fiber sensor has a good agreement with those measured by FBG sensor and FEA. In the outdoor test, the real track suffered from displacement and temperature loads. The distributed optical fiber sensor installed on the rail can monitor the corresponding strain and temperature with a good accuracy.

Fabrication of Planar Type Optical Waveguide for the Application of Biosensor and Detection Characteristics of Staphylococcus Aureus (바이오센서용 평판형 광도파로 센서 제작 및 황색포도상구균 검출 특성)

  • Kim, Jun-Hyong;Yang, Hoe-Young;Yu, Chong-Hee;Lee, Hyun-Yong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.223-223
    • /
    • 2009
  • In this paper, designed and simulated Power Splitter (PS) integrated Mach-Zehnder interferometer (MZI) based planar type optical waveguide devices (which is called here a PS-MZI). The PS-MZI optical waveguide sensor was preceded by a Y-junction, which splits the input power between the sensor, and a reference branch, to minimize the effect of optical power variations. The PS-MZI optical waveguide sensor induced changing phases of the incident beam, which had fallen upon the waveguide through computer simulation, according to the small changes in the index of refraction, thus beam intensity was changed. The waveguide were optimized at a wavelength of 1550 nm and fabricated according to the design rule of 0.45 delta%, which is the difference of refractive index between the core and clad. The fabrication of PS-MZI optical waveguide sensor was performed by a conventional planar lightwave circuit (PLC) fabrication process. The PS-MZI optical waveguide that was fabricated to be applied as a biosensor revealed a low insertion loss and a low polarization-dependent loss. After having etched the over-clad at the sensor part in the MZI optical waveguide that was fabricated, Ti deposition was made on the adhesion layer, and then Au thin-film deposition was carried out thereon. In addition, its optical properties were measured by having changed the index of refraction oil at the sensing part of the MZI. To apply the planar type PS-MZI optical waveguide as a biosensor, a detection test for Staphylococcus aureus was conducted according to changes in concentration, having adopted Ti-alkoxide as ligand. The detection result of the S. aureus by the PS-MZI optical waveguide sensor was possible to the level of $10^1$ CFU/ml.

  • PDF

Quantitative Monitoring of Body Pressure Distribution Using Built-in Optical Sensors

  • Lee, Kang-Ho;Kwon, Yeong-Eun;Seo, Jihyeon;Lee, Byunghun;Lee, Dongkyu;Kwon, Ohwon
    • Journal of Sensor Science and Technology
    • /
    • v.29 no.5
    • /
    • pp.279-282
    • /
    • 2020
  • In this study, body pressure was quantitatively detected using built-in optical sensors, inside an air cushion seat. The proposed system visualizes the effect of the body pressure distribution on the air cushion seat. The built-in sensor is based on the time-of-flight (ToF) optical method, instead of the conventional electrical sensor. A ToF optical sensors is attached to the bottom surface of the air-filled cells in the air cushion. Therefore, ToF sensors are durable, as they do not come in physical contact with the body even after repeated use. A ToF sensor indirectly expresses the body pressure by measuring the change in the height of the air-filled cell, after being subjected to the weight of the body. An array of such sensors can measure the body pressure distribution when the user sits on the air cushion seat. We implemented a prototype of the air cushion seat equipped with 7 ToF optical sensors and investigated its characteristics. In this experiment, the ToF optical pressure sensor successfully identified the pressure distribution corresponding to a sitting position. The data were accessed through a mobile device.

Damage Detection of Fiber-Metal Laminates Using Optical Fiber Sensors (광섬유 센서를 이용한 섬유-금속 적층판의 손상 감지)

  • 양유창;한경섭
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2002.10a
    • /
    • pp.161-164
    • /
    • 2002
  • Optical fiber vibrations sensors (OFVSs) and extrinsic Fabry-Perot interferometer (EFPI) were used in damage monitoring of fiber-metal laminates(FML). The optical fiber vibration sensor and EFPI were applied in order to detect and evaluate the strain, damage and failure of FML. Damages in composites, such as matrix cracks, delamination and fiber breakage may occur as a result of excessive load, fatigue and low-velocity impacts. Tensile test was performed with the measurement of optical signal and acoustic emission (AE). The signals of the optical fiber vibration sensor due to damages were quantitatively evaluated by wavelet transform. EFPI was less sensible to the damage signals compared with the optical fiber vibration sensor. It was found that damage information of comparable in quality to acoustic emission data could be obtained from the optical fiber vibration sensor signals.

  • PDF