• Title/Summary/Keyword: a chamber

Search Result 6,519, Processing Time 0.028 seconds

Implantation of dual chamber pacemaker: report of 2 cases (생리적 심박동조절이 가능한 Dual Chamber Pacemaker이식 치험 2)

  • 김은기
    • Journal of Chest Surgery
    • /
    • v.16 no.4
    • /
    • pp.547-554
    • /
    • 1983
  • Implantation of Dual Chamber Pacemakers Which sense in the Atrium and the Ventricle, and sequentially or synchronously trigger impulses in the both chambers, has led us to the near realization of the ideal "Physiologic Pacing". We have experienced two cases of implantation of Dual chamber pacemaker in September and October, 1983. One patient was a 21-year-old male who had postoperative complete heart block since he was taken Total correction of TOF in May, 1983 . We implanted transvenously a dual chamber pacemaker, VDD type, through the left subclavian vein. In the other patient who came to the emergency room for partial obstruction of small bowels with severe abdominal pain, nausea and vomiting, in whom heart block was found, we implanted a DDD type pacemaker through the left subclavian puncture. The pacemakers have been functioning well postoperatively for more than two months, and the conditions of patient were uneventful.

  • PDF

A STUDY ON THE ANATOMY OF THE PULP CHAMBER FLOOR OF THE PERMANENT MANDIBULAR SECOND MOLAR (하악(下顎) 제2대구치(第二大臼齒) 치수저(齒髓底)의 해부학적(解剖學的) 고찰(考察))

  • Kwon, Hyuk-Choon
    • Restorative Dentistry and Endodontics
    • /
    • v.12 no.1
    • /
    • pp.165-169
    • /
    • 1986
  • A total of 114 extracted human mandibular 2nd molars were used to study the configuration of the floor of the chamber. The specimens were ground and the pulp chamber was examined with a magnifier and explored with sharp explorer. The study showed the shape of the pulp chamber, number of root canals, and the type of canal orifice. The results were as follows, 1. In so far as observing the shape of the pulp chamber of the teeth, 47.4% of the teeth were square, 42.9% were triangle and 9.7% were ovoid shape. 2. 35% of the samples had 2 root canal orifices, 62% had 3 root canal orifices, 3% had 4 root canal orifices. 3. 3% of the specimens showed 'H' shape, 5% showed 'Square' shape, 51% showed 'T' shape, 1% showed 'reverse-T' shape, 35% showed 'I' shape and 5% showed the specific 'C' shape.

  • PDF

Optimization of the Material and Structure of Component Parts for Reducing the Number of Impurity Particles in CVD Process

  • Kim, Won Kyung;Woo, Ram;Roh, Jong Wook
    • Journal of the Korean Ceramic Society
    • /
    • v.56 no.3
    • /
    • pp.277-283
    • /
    • 2019
  • We have examined minimization of the number of impurity particles by replacing the load-lock chamber materials of the chemical vapor deposition equipment through optimization of the pumping method in the deposition chamber. In order to reduce the number of impurity particles in the chamber, the load-lock spacer material was changed from monomer casting nylon to Torlon. Furthermore, we controlled the pumping speed and number of pumping ports, which resulted in a reduction in the impurity particle generation from 2.67% to 0.52%. This study revealed that the selection of the material for the parts of a chemical vapor deposition chamber can minimize particle generation, thereby presenting a method of optimization method of the chemical vapor deposition chamber.

COMBUSTION CHARACTERISTICS AND HEAT FLUX DISTRIBUTION OF PREMIXED PROPANE MIXTURE IN A CONSTANT VOLUME COMBUSTION CHAMBER

  • PARK K. S.
    • International Journal of Automotive Technology
    • /
    • v.6 no.2
    • /
    • pp.79-85
    • /
    • 2005
  • This work is to investigate the surface heat flux and combustion characteristics of premixed propane mixture in a constant volume chamber. The experiment of heat flux and combustion characteristics of premixed propane mixture are performed with various equivalence ratio and initial pressure conditions. Based on the experimental results, it is found that the maximum instantaneous temperature is increased with the increase of initial pressure in the chamber. There are significant differences in the burning velocity of premixed propane mixture at different measuring points in the constant volume combustion chamber. A]so, the trends of temperature difference at each measuring points are similar to the burning velocity in the combustion chamber. It is concluded that the total heat loss during the combustion period is affected by the equivalence ratio and the initial condition of fuel-air mixture.

A Study on the Evaluation of Semi-Anechoic Chamber Characteristics (전파반무향실의 특성평가에 관한 연구)

  • 김민석;김동일
    • Journal of the Korean Institute of Navigation
    • /
    • v.21 no.4
    • /
    • pp.29-38
    • /
    • 1997
  • Because of the result of a large use of electronic equipments, the occupation density of microwave frequency band is highly increased, and electromagnetic environment is getting more seriously bad. It is sometimes reported that electronic machines are not normally operated on account of the influence of undesired electromagnetic wave, which often gives fatal blow to even human life and thus becomes serious social problems. OATS(Open Area Test Site) is principally used to measure EMI or examine elelctromagnetic emission. Because of various restrictions we often build semi-anechoic chamber which has the function of OATS to measure EMI or EMS other than OATS. If the difference of the site attenuation between semi-anechoic chamber and OATS is within ${\pm}3dB$, the semi-anechoic chamber is recognized as adequate facility to measure EMI or EMS. Accordingly authors evaluate and analyze site attenuation due to absorbent materials, polarization, mutual coupling effects, etc. The calculated and the measured site attenuation in semi-anechoic chamber are compared. As a result good agreement is obtained.

  • PDF

A STUDY ON THE ANATOMY OF THE PULP CHAMBER FLOOR OF THE PERMANENT MAXILLARY SECOND MOLAR (상악(上顎) 제이대구치(第二大臼齒) 치수저(齒髓底)의 해부학적(解剖學的) 고찰(考察))

  • Kwon, Hyuk-Choon
    • Restorative Dentistry and Endodontics
    • /
    • v.7 no.1
    • /
    • pp.53-57
    • /
    • 1981
  • A total of 130 extracted human maxillary second molars were used to study the configuration of the floor of the pulp chamber. The specimens were ground and the pulp chamber was examined with a magnifier and explored with sharp explorer. The study showed the shape of the pulp chamber, number of root canals, and the type of canal orifice. The results were as follows; 1. In so far as observing the shape of the pulp chamber of the teeth, 16.9% of the teeth were quadrilateral, 70.0% were triangle and 13.1% were ovoid shape. 2. 13.1% of the specimens have 4 root canal orifices. 73.9% have 3 root canal orifices, 11.5% have 2 root canal orifices and 1.5% have single orifice. 3. 13.1% of the specimens have 2 mesio-buccal canal orifices and among the teeth those have 3 canals, 20.8% show 'Y' shape, 29.1% show straight line and 23.8% show obtuse triangle shape.

  • PDF

Study on flow characteristics of the grit chamber using VOF multi-phase flow simulations (VOF 다상유동 해석을 이용한 침사지 유동특성 연구)

  • Yoon, Jong-Hwan
    • Journal of the Korean Society of Visualization
    • /
    • v.19 no.2
    • /
    • pp.63-73
    • /
    • 2021
  • It is essential to accurately predict the change in water level, velocity, and flow rate for each passage of the grit chamber according to the operating conditions of the pump. In this study, VOF multiphase flow analysis was performed, and the flow characteristics of the grit chamber were predicted. As a result of simulations, the sedimentation phenomenon after the entrance of the grit chamber channel is expected to occur on the side walls. When 6 channels are used, the average speed of the channels is about 52% of the design standard, and when 4 channels are used, the value increases to 74% of the design standard. The average water level in the channels tends to decrease as the flow velocity increases, and the water level in the absorption well with a larger flow rate is maintained lower than that in the absorption well with a smaller flow rate.

Status Change Monitoring of Semiconductor Plasma Process Equipment (주파수 도메인 반사파 측정법을 이용한 플라즈마 공정장비 상태변화 연구)

  • Yunsang Lee;Sang Jeen Hong
    • Journal of the Semiconductor & Display Technology
    • /
    • v.23 no.1
    • /
    • pp.52-55
    • /
    • 2024
  • In this paper, a state change study was conducted through Frequency Domain Reflectometry (FDR) technology for the process chamber of plasma equipment for semiconductor manufacturing. In the experiment, by direct connecting the network analyzer to the RF matcher input of the 300 mm plasma enhanced chemical vapor deposition (PECVD) chamber, S11 was measured in a situation where plasma was not applied, and the frequency domain reacting to the chamber state change was searched. Response factors to changes in the status, such as temperature, spacing of the heating chuck, internal pressure difference, and process gas supply state were confirmed. Through this, the frequency domain in which a change in the reflection value was detected through repeated experiments. The reliability of the measured micro-displacement was verified through reproducibility experiments.

  • PDF

STUDY ON THE THERMAL-FLUID ANALYSIS OF CRYOGENIC CHAMBER FOR COLD CLIMATE TEST OF LARGE WIND TURBINE PARTS (대형 풍력발전기 부품의 극한 환경 시험을 위한 극저온 챔버의 열유동 해석에 대한 연구)

  • Kim, M.K.;Kang, Y.H.;Park, W.G.
    • Journal of computational fluids engineering
    • /
    • v.20 no.3
    • /
    • pp.8-14
    • /
    • 2015
  • More and more, spaces are decreasing which satisfy multiple requirements for wind power plants. However, areas which have excellent wind resources and are free to civil complaints occupy a large space, although they are exposed to the cryogenic environment. This study conducted a thermal-fluid analysis of a cryogenic chamber for testing large wind turbine parts exposed to the cryogenic environment. The position of supply air is placed to the upper area to compare each cooling performance for each location of various outlets in mixing ventilated conditions. The study carried out CFD analysis for the chamber both with and without a test object. For the cases without the test object, the air temperature of the upper supply and down extract type chamber was cooled faster by 5-100% than the others. However, for the cases with the test object, the object temperature of upper supply and center extract on the opposite side type chamber was cooled faster by 33-132% than the others. The cooling performance by the air inside the chamber and the test object did not show the same pattern, which implicates the need to consider the cooling performance by not only the air but also the test object in the large cryogenic chamber design for testing large parts.

Modeling and Simulation of Combustion Chamber Test Facility Oxidizer Supply System (연소기 연소시험설비 산화제 공급시스템 해석)

  • Chun, Yonggahp;Cho, Namkyung;Han, Yeoung-Min
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.16 no.6
    • /
    • pp.92-97
    • /
    • 2012
  • The propulsion system of space launch vehicle generates thrust by supplying oxidizer and fuel to combustion chamber. KSLV-II 2nd stage engine, currently under development by KARI, is to use liquid oxygen as a oxidizer and JET-A1 as a fuel. The 2nd stage pump-fed engine is mainly composed of combustion chamber, turbo-pump and engine supply system. To develop liquid propulsion engine, the development of combustion chamber must be preceded. For performance validation of the combustion chamber, the designed and manufactured combustion chamber should be tested in combustion chamber test facility (CCTF). The detailed design for the planned CCTF in Naro Space Center was conducted. The oxidizer supply system modeling using AMESim was performed based on the results of the detailed design, and the oxidizer supply characteristics was analyzed in this paper.