• Title/Summary/Keyword: Zone Control

Search Result 1,499, Processing Time 0.029 seconds

QLQG/LTR Control of the Nonlinear Timing-Belt Driving Systme Using DSP (DSP를 이용한 비선형 타이밍 벨트 구동시스템의 QLQG/LTR 제어)

  • 한성익;방두열
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.10 no.4
    • /
    • pp.40-47
    • /
    • 2001
  • In this pater, the QLQG/LTR control method is applied for the position control of the nonlinear timing belt driving sys-tem. Parameters fo the plant are identified by genetic algorithm and nonlinear elements, such as Coulomb friction and dead-zone, and quasi-linearized by RIDE method. Comparing with the LQG/LTR contro. the QLQG/LTR has similar structures of the LQG/LTR, but this method can consider nonlinear effects in designing the controller. Thus, the QLQG/LTR control system is robust to hard nonlinearities such as Coulomb friction, dead-zone, etc. Forma given hard non-linear system through experiments, it is shown that the tracking performance of the QLQG/LTR control system can be very improved that the LQF/LTR control system.

  • PDF

A Study on the Space Zoning and Area Composition of the Operation Department in Regional Public Hospitals - Focused on Net Floor Area (지방의료원 수술부 영역 및 면적 구성에 관한 조사·분석연구 - 순면적을 중심으로)

  • Yun, Woo Yong;Chai, Choul Gyun
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.25 no.3
    • /
    • pp.25-36
    • /
    • 2019
  • Purpose: To establish guidelines for local public hospitals, the survey was conducted primarily on the current status of local public hospitals, focusing on the zone configuration and the spatial area of the operating department. Methods: 3 Methods have been used in this paper. 1) Analyzing drawings to derive the net floor area of each room. 2) A literature survey about composition of the zone by infection control. 3) Observation survey for user circulation analysis. Results: The operation department consists of the major, secondary, support and connected zones according to the user's actions. The spatial area composition ratio for each zone is major zone: 41.79%, secondary zone: 10.87%, support zone: 23.10%, and connected zone: 24.24%. Implications: This study is a basic research for guideline for the operation department in local public hospitals. In this study, zones configuration of the operation departments are classified in terms of user actions and room functions. In the future, it is required to establish criteria considering infection control and copper connection aspects.

Process Design of Piston-Pin for Automobile by the Flow Control (유동제어를 통한 자동차용 피스톤-펀의 공정설계)

  • 김동진;김병민;이동주
    • Transactions of Materials Processing
    • /
    • v.10 no.2
    • /
    • pp.151-159
    • /
    • 2001
  • Flow defect of a piston-pin for automobile parts is investigated in this study. In combined cold extrusion of piston-pin, lapping defect, which is a kind of flow defect, appears by the dead metal zone. This appearance evidently happens in products with a thin thickness to be pierced for the dimensional accuracy and the decrease of material loss. The flow defect that occurs in piston-pin has bad effects on the strength and the fatigue life of piston-pin. Therefore, it is important to predict and prevent defects in the early stage of process design. The best method that can prevent flow defect is removing or reducing dead metal zone through material flow control. The finite element simulations are applied to analyze the flow defect. This study proposes processes for preventing flow defect by removing dead metal zone. Then the results are compared with the experimental ones for verification. These FE simulation results are in good agreement with the experimental ones.

  • PDF

Morphometric Study of the Irradiation Effect on the Cartilage Formation in the Rat Mandibular Condyle (방사선 조사가 백서 하악과두 연골 형성에 미치는 영향에 관한 형태계측학적 연구)

  • Kim Jeong-Hwa;Heo Min-Suk;Lee Sam-Sun;Choi Soon-Chul
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.29 no.1
    • /
    • pp.87-103
    • /
    • 1999
  • Purpose: This study was undertaken to quantitatively estimate the degree of the damage and recovery of the irradiated rat condylar cartilage using the Image Analyzer. Materials and Methods: Experimental animals were 16 male rats of the Sprague-Dawley strain at the age of 20 day irradiated with the dose of 10 Gy in their head and neck region. Four rats were sacrificed at the each of the following time intervals - 1, 4, 7 and 14 days, respectively. The same number of control group animals were sacrificed at the each age of 21. 24, 27 and 34 days, respectively. The specimens were stained with 0.5% toluidine blue and examined with light microscope. The condylar cartilage was divided into 4 zones; fibrous zone, proliferating zone, upper hypertrophic zone, and lower hypertrophic zone. And then, the proliferating zone was subdivided into 2 layers - upper and lower layer, and upper and lower hypertrophic zone were subdivided into three layers, respectively - upper, middle and lower layer. With the aid of Image Analyzer, morphometric analysis was performed. The thickness, the numerical density of cells, the cell area density, the extracellular matrix area density, the mean area of single cell, the mean area of extracellular matrix per single cell were measured and analysed. Results: In the experimental group, the thickness of the fibrous zone was slightly increased and that of the proliferating zone and the upper and the lower hypertrophic zone was markedly decreased. With time, the thickness of the fibrous zone was gradually increased and that of the proliferating zone and the upper and the lower hypertrophic zone was steadily in the decreased state. The numerical density of cells of the proliferating zone was increased on post-irradiated 1 day, but decreased after post-irradiated 4 day, and that of the upper hypertrophic zone was decreased. The numerical density of cells of the lower hypertrophic zone was decreased in the early stage and then was decreased or not significantly different from that of the control group with time. In the experimental group, the cell area density of the fibrous zone and the proliferating zone was decreased in the early stage and then gradually increased or not significantly different from that of the control group with time. The cell area density of the upper and the lower hypertrophic zone was varied with time. The extracellular matrix area density value were totally opposite to the cell area density values: The mean area of single cell of the fibrous zone and the proliferating zone was .decreased on post-irradiated 1 day, and increased after post-irradiated 4 day. The mean area of single cell of the upper hypertrophic zone was varied with each layer and time. In the experimental group, the mean area of extracellular matrix per single cell of the fibrous zone was not significantly different with control group, and that of the proliferating zone was decreased on post-irradiated 1 day, and increased after post-irradiated 4 day. The mean area of extracellular matrix per single cell of the lower hypertrophic zone was increased in the early stage. and that of upper hypertrophic zone was varied with each layer and time. Conclusion: The condylar cartilages of rats were affected by irradiation, but the changes were vaned with each layer and time. By morphometric analysis. the changes of the cells of the condylar cartilage of irradiated rat could be calculated quantitatively.

  • PDF

A Study on the Control Standards and an Environmental Lighting Zone-Setting method for Making Light Pollution Management (빛공해 방지를 위한 관리기준 및 조명환경관리구역 설정 방안에 관한 연구)

  • Kim, Ki-Tae;Oh, Min-Seok;Kim, Hway-Suh
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.12
    • /
    • pp.27-33
    • /
    • 2011
  • This study aims to suggest some problems, which occur when environmental lighting zone is set by use-zone only, by comparing and analyzing the artificial illumination luminance. In addition, this study aims to review the control standards of light pollution and to suggest a practical environmental lighting zone-setting method. I checked out the standards of average surface luminance and luminance contrast as for light pollution management. In addition, I did some research on evaluation of light pollution on surroundings based on investigation of use-environment as for lighting environment setting method.

Effect of the root-zone temperature grown in the greenhouse on the growth of chives

  • Jung, Kwan-hui;Han, Sangjun
    • Proceedings of the Korean Society of Crop Science Conference
    • /
    • 2017.06a
    • /
    • pp.222-222
    • /
    • 2017
  • This study aimed to determine an optimal temperature of root zone for the chive cultivation in a greenhouse during the winter season that may raise the possibility of chive (Allium schoenoprasum L.) harvest any time year-round by reducing energy consumption. The maximum and minimum temperatures of root zone were 26.8 and $19.8^{\circ}C$ for the R-Z20, 28.3 and $23.6^{\circ}C$ for the R-Z25 and 22.4 and $14.3^{\circ}C$ for the control. The highest fresh weights of shoot and root, plant height, root length and stem diameter were observed in the R-Z20 treatment. There was no significant difference in the growth between the R-Z25 and control treatment. These results suggest that the optimal temperature of root zone is $20^{\circ}C$ for the chive cultivation in the greenhouse during winter season.

  • PDF

Design and control of quiet zone (principle and example) (조용한 공간 만들기 (방법론과 예))

  • Kim, Yang-Han;Yun, Du-Byeong;Nam, Gyeong-Uk
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.565-570
    • /
    • 2000
  • In order to make a quiet zone, one can consider methods to generate a secondary sound field that cancels a primary sound field. Active noise control (ANC) is one of the kinds. This paper mainly deals with the issues on determining the optimal positions of control sources and sensors for making a desired quiet zone. The issues address the reason why the positions are important, how the positions are optimized, and what the measure on the optimal positions is in an uncertain sound field. It is also shown that a power control is applicable to a specific uncertain sound field. In addition, this paper shows that a control material method, which passively changes a boundary condition, is essentially found to be on the same road of ANC.

  • PDF

A Comparative Analysis of Domestic and Foreign Standards to Improve the Performance of Zone Smoke Control System (거실 제연설비 성능 개선을 위한 국내·외 기준 비교 분석에 관한 연구)

  • Huh, Ye-Rim;Kim, Yoon-Seong;Kim, Hye-won;Jin, Seung-Hyeon;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.04a
    • /
    • pp.83-84
    • /
    • 2022
  • In Korea, smoke control measures through NFSC 501 are proposed to reduce human casualties caused by smoke in the event of a fire. However, as a result of investigating and analyzing domestic and foreign standards, it was found that domestic regulations do not set fire source, but simply set smoke emissions by floor area or height of smoke boundary. Foreign regulations set fire source. Therefore, it is judged that it is necessary to review whether the current domestic regulations can be applied in the event of an actual building fire. So, this paper aims to identify the differences in domestic and foreign standards through investigation and analysis of related standards for fire zone smoke control system in each country and use them as basic data to improve the performance of zone smoke control system.

  • PDF

A Study on the Controller of Integration Smoke Control System (통합 제연시스템의 컨트롤러 개발에 관한 연구)

  • Lee, Dong-Myung
    • Fire Science and Engineering
    • /
    • v.20 no.1 s.61
    • /
    • pp.77-82
    • /
    • 2006
  • This study defined engineering mechanism and compensation method to establish reference pressure of smoke control zone with atmospheric pressure that is compensated for temperature. The reliable controller of integration smoke control was developed by establishing the specifications, algorithms and constructing engineering data. The development of controller for integration smoke control can cut down number of processes, manufacturing and installation cost by removing pressure measurement pipe established separately for non smoke control zone, and improve the accuracy of pressure differential by embedding pressure measurement ports for non smoke control zone. More correct and reliable pressure differentials can be obtained by the central control from controller of integration smoke control rather than the existent individual control. This will provide the basics and the flexibility to the integral smoke control system and accordingly improve the performance of disaster prevention.

Blast Furnace Modeling for Predicting Cohesive Zone Shape (융착대 예측을 위한 고로공정 모델링)

  • Yang, Kwang-Heok;Choi, Sang-Min;Jung, Jin-Kyung
    • 한국연소학회:학술대회논문집
    • /
    • 2006.04a
    • /
    • pp.39-45
    • /
    • 2006
  • Analysis of the internal state of the blast furnace is needed to predict and control the operating condition. Especially, it is important to develop modeling of blast furnace for predicting cohesive zone because shape of cohesive zone influences overall operating condition of blast furnace such as gas flow, chemical reactions and temperature. because many previous blast furnace models assumed cohesive zone to be fixed, they can't evaluate change of cohesive zone shape by operation condition such as PCR, blast condition, and production rate. In this study, an axi-symmetric 2-dimensional steady state model is proposed to simulate blast furnace process. In this model, cohesive zone is changed by solid temperature range, FVM is used for numerical simulation. To find location of cohesive zone whole calculation procedure is iterated Until cohesive zone is converged. Through this approach, shape of cohesive zone, velocity, composition and temperature within the furnace are predicted by model.

  • PDF