• Title/Summary/Keyword: ZnO Arrester

Search Result 100, Processing Time 0.026 seconds

A Study on the microstructure and Surge Characteristics of ZnO varistors for distribution Arrester (배전급 피뢰기용 ZnO 바리스터 소자의 미세구조 및 서지 특성에 관한 연구)

  • 김석수;조한구;박태곤;박춘현;정세영;김병규
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.15 no.2
    • /
    • pp.190-197
    • /
    • 2002
  • In this thesis, ZnO varistors with various formulation, such as A∼E, were fabricated according to ceramic fabrication method. The microstructure, electrical properties, and surge characteristics of ZnO varistors were investigated according to ZnO varistors with various formulation. In the microstructure, A∼E\`s ZnO varistor ceramics sintered at 1130$\^{C}$ was consisted of ZnO grain(ZnO), spinel phase (Zn$\_$2.33/Sb$\_$0.67/O$\_$4/), Bi-rich phase(Bi$_2$O$_3$) and intergranuler phase, wholly. Lightning impulse residual voltage of A, B, C and E\`s ZnO varistors suited standard characteristics, below 12kV at current of 5kA. On the contrary, D\`s ZnO varistor exhibited high residual voltage as high reference voltage. In the accelerated aging test, leakage current and watt loss of B, C and D\`s ZnO varistors increases abruptly with stress time under the first a.c. stress(115$\^{C}$/3.213kV/300h). Consequently, C varistor exhibited a thermal run away. On the contrary, leakage current and watt loss of A and C\`s ZnO varistors which show low initial leakage current exhibited constant characteristics. After high current impulse test, A\`s ZnO varistor has broken the side of varistor but impulse current flowed. On the contrary, E\`s ZnO Varistor exhibited good discharge characteristics which the appearance of varistor was not wrong such as puncture, flashover, creaking and other significant damage. After long duration impulse current test, E\`s ZnO varistor exhibited good discharge characteristics which the appearance of varistor was not wrong such as puncture, flashover, creaking and other significant damage. After high current impulse test and long duration impulse current test, E\`s ZnO varistor exhibited very good characteristics which variation rate of residual voltage is 1.4% before and after test.

A Development of ZnO Varistor for Railroad Vehicle d.c. Arrester (전철탑재형 직류피뢰기용 ZnO 바리스터의 개발)

  • Cho, I-Gon;Park, Choon-Hyun;Jung, Se-Young;Song, Tae-Kwon;Kim, Suk-Soo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.552-556
    • /
    • 2002
  • The microstructure and electrical characteristics of A~C's ZnO varistors fabricated according to variable sintering condition, which sintering temperature is $1130^{\circ}C$ and speeds of pusher are A: 2mm/min, B: 4mm/min, C: 6mm/min, respectively, were investigated. In the microstructure, A~C's ZnO varist-ors fabricated variable sintering condition was consisted of ZnO grain(ZnO), spinel phase$(Zn_{2.33}Sb_{0.67}O_4)$ Bi-rich $phase(Bi_{2}O_{3})$, wholly. Varistor voltage of A~C's ZnO varistors sintered at $1130^{\circ}C$ increased in order A < B < C's ZnO varistors. C's ZnO varistor exhibited good characteristics that nonlinear exponent is 31.70. Leakage current of A~C's ZnO varistors exhibited below 2mA at rated voltage. Lightning impulse residual voltage of A's ZnO varistor suited standard characteristics, which is 3.85kV at 2.5kA, 4.4kV at 5kA and 5.16kV at 10kA. After multi lightning impulse residual voltage test of A's ZnO varistor exhibited good discharge characteristics which ZnO varistor reveals no evidence of puncture, flashover, cracking in visual examination. After high current impulse test of A's ZnO varistor exhibited good discharge characteristics, which variation rate of residual voltage is 0.4% before and after test, and revealed no evidence.

  • PDF

A study on the Microstructure and electrical characteristics of ZnO varistors for arrester (피뢰기용 ZnO 바리스터 소자의 미세구조 및 전기적 특성에 관한 연구)

  • 김석수;조한구;박태곤;박춘현
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.489-494
    • /
    • 2001
  • In this thesis, the microstructure and electrical properties of ZnO varistors were investigated according to ZnO varistors with various formulation. A∼E's ZnO varistor ceramics were exhibited good density, 95% of theory density and low porosity, 5%, wholly. The average grain size of A-E's ZnO varistor ceramics exhibited 11.89$\mu\textrm{m}$, 13.57$\mu\textrm{m}$, 15.44$\mu\textrm{m}$, 11.92$\mu\textrm{m}$, 12.47$\mu\textrm{m}$, respectively. Grain size of C's ZnO varistor is larger and grain size of A and D's are smaller than other varistors. In the microstructure, A∼E's ZnO varistor ceramics sintered at l130$^{\circ}C$ was consisted of ZnO grain(ZnO), spinel phase(Zn$\sub$2.33/Sb$\sub$0.67/O$_4$), Bi-rich Phase(Bi$_2$O$_3$) and inergranular phase, wholly. Reference voltage of A∼E's ZnO varistor sintered at 1130$^{\circ}C$ decreased in order D, E > A > B > C's ZnO varistors. Nonlinear exponent of varistors exhibited high characteristics, above 30, wholly. Consequently, C's ZnO varistor exhibited good nonlinear exponent, 68. Lightning impulse residual voltage of A, B, C and E's ZnO varistors suited standard characteristics, below 12kV at current of 5kA.

  • PDF

A New Approach to On-Line Monitoring Device for ZnO Surge Arresters

  • Lee Bok-Hee;Gil Hyoung-Jun;Kang Sung-Man
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.5C no.3
    • /
    • pp.131-137
    • /
    • 2005
  • This paper describes a new approach to the algorithm and fundamental characteristics of the device for monitoring the leakage currents flowing through zinc oxide (ZnO) surge arresters. In order to obtain a technique for a new on-line monitoring device that can be used in the deterioration diagnosis of ZnO surge arresters, the new algorithm and on-line leakage current detection device for extracting the resistive and capacitive currents using the phase shift addition method were proposed. The computer-based on-line monitoring device can sense accurately the power frequency leakage currents flowing through ZnO surge arresters. The on-line leakage current monitoring device of ZnO surge arresters proposed in this work has the high sensitivity compared to the third harmonic leakage current detection devices. As a consequence, it was found that the proposed leakage current monitoring device would be useful for forecasting the defects and degradation of ZnO surge arresters.

Electric Field Analysis of Polymeric ZnO Surge Arrester for loading in Electric Traction (전철 탑재형 ZnO 고분자 피뢰기의 전계해석)

  • Lee, U.Y.;Jang, D.U.;Kang, S.H.;Lim, K.J.;Han, S.W.;Cho, H.G.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2293-2295
    • /
    • 1999
  • Polymeric ZnO surge arresters are used to protect the electric traction to limit the overvoltage invading into its inner electrical circuits. We have developed polymeric ZnO surge arresters design and investigated electric field analysis of its by FEM(Finite Element Method).

  • PDF

Leakage Currents Flowing through Lightning Surge Arresters under Various Fault Conditions in Receiving and Distribution Power Systems (수배전계통의 여러 가지 고장조건에서 피뢰기에 흐르는 누설전류)

  • Lee, Bok-Hee;Kil, Hyeong-Joon;Kang, Sung-Man;Choi, Hwee-Sung
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.5
    • /
    • pp.132-139
    • /
    • 2004
  • Unsymmetrical faults are classified into single line-to-ground faults, line-to-line faults, or double line-to-ground faults in receiving and distribution power systems. Many of overhead distribution-line faults are single line-to-ground faults, and lightning surge arresters are stressed by system frequency overvoltages due to unsymmetrical faults. In this work, the unsymmetrical faults in receiving and distribution systems were experimentally simulated, and the characteristics of total leakage current flowing through lightning surge arresters due to various unsymmetrical faults were investigated. As a result, a little variations of the leakage current flowing through Zinc oxide (ZnO) surge arresters in the range of $\pm$10[%] voltage regulations were observed. It could be concluded that the unsymmetrical faults have no effect on the long-term life performance of ZnO surge arresters in effective grounding systems. On the other hand, the magnitude of the leakage current flowing through ZnO surge arrester elements under single line-to-ground faults was more than 140 times as compared with that under normal operating voltages in ineffective grounding systems. But abnormal voltages caused by line-to-line faults and double line-to-ground faults have a little effect on total leakage current of ZnO surge arrester elements.

The Electrical Characteristics of ZnO varistor for d.c. Arrester (직류 피뢰기용 ZnO 소자의 전기적 특성)

  • Kim, Seok-Sou;Choi, Ike-Sun;Cho, Han-Gu
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07b
    • /
    • pp.1106-1110
    • /
    • 2003
  • The electrical characteristics of $A{\sim}C's$ ZnO varistors fabricated according to variable sintering condition, which sintering temperature is $l130^{\circ}C$ and speeds of pusher are A: 2mm/min, B: 4mm/min, C: 6 mm/min, respectively, were investigated. The varistor voltage of $A{\sim}C's$ ZnO varistors sintered at $1130^{\circ}C$ increased in order A < B $A{\sim}C's$ ZnO varistors exhibited below 2mA at rated voltage. Lightning impulse residual voltage of A's ZnO varistor suited standard characteristics, which is 3.85kV at 2.5kA, 4.4kV at 5kA and 5.16kV at 10kA. After multi lightning impulse residual voltage test of A's ZnO varistor exhibited good discharge characteristics which ZnO varistor reveals no evidence of puncture, flashover, cracking in visual examination. After high current impulse test of A's ZnO varistor exhibited good discharge characteristics, which variation rate of residual voltage is 0.4% before and after test, and revealed no evidence.

  • PDF

Effect of Multiple Lightning Impulse Currents on Zinc Oxide Arrester Blocks (산화아연 피뢰기 소자의 다중 뇌 임펄스 특성)

  • Lee, Bok-Hee;Kang, Sung-Man;Pak, Keon-Young;Choi, Hwee-Sung
    • Proceedings of the KIEE Conference
    • /
    • 2003.10a
    • /
    • pp.22-24
    • /
    • 2003
  • In this work, in order to investigate the effect of multiple lightning impulse currents on zinc oxide arrester blocks. We have been designed and fabricated a multi-impulse generator which can produce quintuple voltages with $1.2/50{\mu}s$ to 100kV and quintuple currents with $8/20{\mu}s$ to 12kA and we have evaluated the characteristics of zinc oxide arrester block using several electrical and physical methods after the multi-impulse test. It was found that the multi-impulse failures of ZnO arrester blocks were mainly caused by surface flashover and the multi-impulse currents test would be more suitable than single impulse current test in evaluation of the characteristics of zinc oxide arrester blocks corresponding to actual situations.

  • PDF

Temperature and Leakage Current Characteristics with Structure of Polymeric Surge Arresters (폴리머 피뢰기의 구조에 따른 온도와 누설전류 특성)

  • Cho, Han-Goo;Lee, Un-Yong;Kim, Ha-Na
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.513-514
    • /
    • 2006
  • This paper presents the temperature characteristics with the structure of 18 kV surge arresters for distribution system. Three types of polymer arrester were fabricated and a ceramic arrester was also prepared to investigate. Below $100^{\circ}C$, three types of polymeric arresters exhibited almost the same leakage current value, but above $100^{\circ}C$, the polymeric arresters whose module was injected into polymeric housing with the grease exhibited the highest leakage current. In contrary, the arresters being manufactured by directly injecting silicone rubber onto arrester module exhibited the lowest leakage current. The rapid rising of leakage current of the polymeric arresters with the grease at $120^{\circ}C$ was because of the deterioration of the insulation characteristics of the grease between the FRP module and the silicone housing. All polymeric arresters exhibited the same surface temperature characteristics but the ceramic arresters was slower than the polymer arrester in heat emission despite the lowest leakage current. It was thought that the air layer between ZnO varistor blocks and the ceramic housing prevented the heat emission.

  • PDF

Changes of Electrical Characteristics of Arrester Blocks by a Multiple-lightning Impulse Current (다중 뇌충격전류에 의한 피뢰기 소자의 전기적 특성 변화)

  • Lee, J.H.;Cheon, S.G..;Kim, I.K.;Han, J.S.;Kil, G.S.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.2035-2037
    • /
    • 2000
  • This paper describes the effect of lightning impulse current on deterioration of ZnO blocks for distribution arrester. In this study. a multiple-lightning impulse current generator which can produce quadruple 8/20 ${\mu}s$ 5 kA is designed and fabricated, and total energy applied to the arrester block at each pulse is about 1,217 J. The experimental results indicate that the type of arresters are more vulnerable to deteriorate or damage at multiple-lightning impulse current.

  • PDF