• Title/Summary/Keyword: Zn Corrosion

Search Result 342, Processing Time 0.025 seconds

Corrosion Protection of Steel by Applying a Zn-Sn Metal Spray System (Zn-Sn 합금을 이용한 강구조물의 금속용사공법 방식성능평가 연구)

  • Ryu, Hwa-Sung;Jeong, Dong-Geun;Lee, Han-Seung
    • Journal of the Korea Institute of Building Construction
    • /
    • v.14 no.6
    • /
    • pp.505-513
    • /
    • 2014
  • The purpose of this study is to evaluate the corrosion protective properties of a Zn-Sn metal spray method according to the contents of Zn and Sn by a CASS test and the electrochemical theory. In the experiment, the CASS test and the electrochemical test were conducted to investigate the corrosion protective property of the Zn-Sn Metal Spray system, the Zinc galvanizing system, and the heavy duty coating system. As a result, it was confirmed that the Zn-Sn (65:35) Metal Spray system had very high corrosion protective property through the electrochemical characteristic as comparison with the other anti-corrosion systems and was very effective to prevent steel products from corrosion.

Galvanic Corrosion of Zn/Steel Couple in Aqueous MgCl2

  • Tada, E.;Katakami, S.;Nishikata, A.
    • Corrosion Science and Technology
    • /
    • v.16 no.4
    • /
    • pp.183-186
    • /
    • 2017
  • Galvanic corrosion tests of Zn/steel couples were conducted in 1 M NaCl and $1M\;MgCl_2$ solutions to investigate the impact of magnesium ion on corrosion behavior of the couples. Two types of Zn/steel couples were used for measurements of open circuit potential (OCP) and galvanic current. From the results of OCP transient of Zn/steel couples, the corrosion potential in $1M\;MgCl_2$ was a more positive value than that in 1 M NaCl during the sacrificial dissolution of Zn. However, earlier increase of OCP of the couples in $1M\;MgCl_2$ solution indicates that the sacrificial dissolution rate of Zn in $1M\;MgCl_2$ was enhanced more than that in 1 M NaCl, agreeing with the results on transients of galvanic current. This result is due to that cathodic reaction on the steel surface of the Zn/steel couple was enhanced in $1M\;MgCl_2$ by the occurrence of hydrogen evolution reaction.

Investigation of Corrosion Characteristics with Zn, PTFE Hybrid Coating for SS400 in Sea Water (Zn, PTFE 복합 코팅에 의한 SS400 강의 해수 부식 특성 변화 연구)

  • Han, Min Su;Prak, Jae Cheul;Jang, Seok Ki;Kim, Seong Jong
    • Corrosion Science and Technology
    • /
    • v.10 no.6
    • /
    • pp.205-211
    • /
    • 2011
  • The severe corrosion environment makes the steel product lifecycle short while Cu-alloys with anti-corrosion characteristic used in sea water are too expensive. This study shows that the Cu-alloy(Cu-37.25% Zn-0.67%Al) used in sea water environment can be superseded by SS400 with various coating process, evaluating electrochemical characteristics. Three coating processes were applied to SS400 such as PTFE + Zn coaing, Zn + PTFE coating and only Zn electrogalvanizing coaing. Various electrochemical experiments such as open circuit potential measurments, potentiodynamic polarization tests and analyses of Tafel constants. Mechanical properties were also measured by tensile test and hardness tests. As a result, Zn + PTFE coating for SS400 steel presented the excellent anti-corrosion characteristic in sea water.

Effect of wet/dry transition on the atmospheric corrosion of Zn (아연의 대기부식에 미치는 주기적 침적/건조 효과)

  • Kim, Ki-Tae
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 1998.05a
    • /
    • pp.3-3
    • /
    • 1998
  • The atmospheric corrosIOn properties of Zinc (Zn) under wet/dry transition of $H_20$ film were investigated in this study. The atmospheric corrosion of metal is usually occurred as a result of repetitious thickness transition (so called wet/dry transition) of liquid phase which is covering the metal surface. Corrosion potential and the polarization behaviour of Zn during liquid film thickness transition were measured by Kelvin probe method which IS using vibrating reference electrode without touching the liquid film. The oxidized states of Zn as a result of successive wet/dry transition were also investigated by X-ray diffraction (XRD) and X-ray photoelectron spectroscopy (XPS). The results show that the corrosion potential and the corrosIOn rate of Zn both are increasing during drying. However, the corrOSIon rate is decreasing again when the Zn surface is completely dried while the corrosion potential still remains high. This behaviour can be explained by the polarization behaviour change of Zn according to the $H_20$ film thickness change. The completely dried surface is consisted mostly with Zn and ZnO phases. After a number of cycles of wet/dry transition, however, the oxidized Zn phase of ${\varepsilon}-Zn(OH)_2$, which has rather voluminous and defected structure, were found.

  • PDF

A Study on the Characteristics of Salt Spray Test of Roll Formed and Zn-Ni Electrodeposited Steel Bolts (전조 후 Zn-Ni 전기도금한 강 볼트의 염수분무 특성에 관한 연구)

  • Hamrakulov, B.;Son, Y.H.;Kim, I.
    • Transactions of Materials Processing
    • /
    • v.21 no.5
    • /
    • pp.330-335
    • /
    • 2012
  • Roll formed steel bolts are electrodeposited with Zn-Ni to protect themselves from corrosion. However, white storage stain or white rust(corrosion) is found on Zn-Ni electrodeposited surface of steel bolts when they are exposed to moisture. In this paper a new process is introduced to protect Zn-Ni electrodeposited steel bolt from white storage stain or white rust for a long time under the salt spray test and high humidity test conditions. The better corrosion resistance could be gotten by the additional process of Ni-P electroless deposition and heat treatment to conventional manufacturing method of Zn-Ni coated steel bolt. The corrosion resistance of Zn-Al powder slurry coated steel bolt showed better than that of Zn-Ni electrodeposited one.

Corrosion Resistance of Zn and Cu Coated Steel Pipes as a Substitute for Cu Pipe in an Air Conditioner System

  • Shin, Jae-Gyeong;Park, Chan-Jin;Hong, Sung-Kil
    • Corrosion Science and Technology
    • /
    • v.8 no.1
    • /
    • pp.40-43
    • /
    • 2009
  • We investigated the corrosion resistance of Zn and Cu coated steel pipes as a substitute for Cu pipe in an air-conditioner system. In addition, the galvanic corrosion tendency between two dissimilar metal parts was studied. The corrosion resistance of the Cu electroplated steel was similar to that of Cu, while the corrosion rate of the Zn electro- galvanized and the galvalume (Zn-55 % Al) coated steels was much higher and not suitable for Cu substitute in artificial sea water and acidic rain environments. Furthermore, the galvanic difference between Cu electroplated steel and Cu was so small that the Cu coated steel pipe can be used as a substitute for Cu pipe in an air-conditioner system.

Corrosion Resistance of the Roll Formed Steel Bolts with the Various Types of Coating Methods (2) (다양한 코팅 방법에 따른 전조한 강 볼트의 내부식성 (2))

  • Mamatov, S.;Hamrakulov, B.;Son, Y.H.;Kim, I.
    • Transactions of Materials Processing
    • /
    • v.28 no.2
    • /
    • pp.77-82
    • /
    • 2019
  • Corrosion occurs well on surface of roll formed and Zn alloy subsequently electro-deposited on steel bolt under wet condition. In this study, variations in corrosion resistance were investigated through the measurement of polarization curves on steel bolts which were roll formed and subsequently coated with various types of coating methods. According to the measured polarization curve, Ni-P electroless deposits on roll formed steel increased the resistance to corrosion. The corrosion resistance of Zn alloy powder coated steel bolt was found to be better than that of Zn-Ni electro-deposited sample.

CORROSION BEHAVIOR OF Al-Zn ALLOY AS A SACRIFICIAL ANODE OF ORV TUBES

  • Jin, Huh;Lee, Ho-Kyun;Lee, Jae-Ho
    • Journal of the Korean institute of surface engineering
    • /
    • v.32 no.3
    • /
    • pp.452-455
    • /
    • 1999
  • ORV which vaporizes LNG to NG is consisted of tube and header whose substrate is aluminum alloy. The corrosion of the tube is very severe because of sea water being used as the heating source. In this research to protect ORV substrate material, the corrosion behavior of aluminum alloys was investigated for the sacrificial role of Al-Zn alloy for ORV tubes. The electrochemical behavior of aluminum alloys in sea water was investigated. The corrosion behavior of thermally-sprayed and cladded samples were compared through salt spray tests. Al-Zn alloy can act as a sacrificial anode and cladded Al-Zn alloy has a better corrosion resistance than that of thermally sprayed one. The galvanic effect of Al-Zn to substrate material was conformed from scratched sample tests.

  • PDF

Innovative Development of Al-Zn-Si Coated Sheet Steels for Automotive Applications

  • Jong-Sang Kim;Suk-Kyu Lee;Doo-Jin Paik
    • Corrosion Science and Technology
    • /
    • v.23 no.4
    • /
    • pp.296-301
    • /
    • 2024
  • Steels have excellent mechanical properties and weldability. They are also economically producible. Thus, they are widely applied in various industries. However, they have a disadvantage in that rust can occur after a certain period of time. To compensate for this, Zn, which has excellent sacrificial corrosion resistance, can be coated on steels. With global zinc consumption increasing at the current rate, depletion is expected in the near future. Recently, POSCO has developed innovative Al-Zn-Si alloy coated steel sheets with better corrosion resistance than Zn coating. In this study, corrosion resistance, weldability, friction characteristics, and so on were evaluated compared to GI steel sheets to evaluate their applicability to automotive steel sheets. It showed excellent corrosion resistance even at a lower coating weight compared to GI steel sheet. It was also excellent in terms of galling and welding LME. Its spot welding life, electrodeposition coating, and bendability were equally excellent. This is presumed to be related to the formation of the Al-Zn-Si alloy phase at the interface of the coating layer.

Corrosion Performance of Al and Zn Coatings Deposited by Arc Thermal Spray Process in 3.5 wt.% NaCl-Contaminated Concrete Pore Solution (3.5wt.% NaCl로 오염된 콘크리트 기공 용액에서 아크 용사 공정에 의해 부착된 Al 및 Zn 코팅의 부식 성능)

  • Singh, Jitendra Kumar;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.05a
    • /
    • pp.59-60
    • /
    • 2023
  • The corrosion of steel rebar embedded in the coastal areas is corroding once the chloride ions ingress through the pores of the concrete. Therefore, in the present study, a 100 ㎛ thick Al and Zn coating was deposited by an arc thermal spray process onto the steel. The corrosion studies of these deposited coatings were assessed in 3.5 wt.% NaCl contaminated concrete pore (CP) solution with immersion periods. The results show that the Al coating is more corrosion resistance compared to the Zn coating attributed to the formation of gibbsite (γ-Al(OH)3) whereas Zn coating exhibits Zn(OH)2 onto the coating surface as passive layer. The Zn(OH)2 is readily soluble in an alkaline solution. Alternatively, γ-Al(OH)3 on the Al coating surface is less solubility in the alkaline pH, which further provides barrier protection against corrosion.

  • PDF