• Title/Summary/Keyword: Zircaloy-4 cladding

Search Result 110, Processing Time 0.027 seconds

Development of the Automated Ultrasonic Flaw Detection System for HWR Nuclear Fuel Cladding Tubes (중수로형 핵연료 피복관의 자동초음파탐상장치 개발)

  • Choi, M.S.;Yang, M.S.;Suh, K.S.
    • Nuclear Engineering and Technology
    • /
    • v.20 no.3
    • /
    • pp.170-178
    • /
    • 1988
  • An automated ultrasonic flaw detection system was developed for thin-walled and short tubes such as Zircaloy-4 tubes used for cladding heavy-water reactor fuel. The system was based on the two channels immersion pulse-echo technique using 14 MHz shear wave and the specially developed helical scanning technique, in which the tube to be tested is only rotated and the small water tank with spherical focus ultrasonic transducers is translated along the tube length. The optimum angle of incidence of ultrasonic beam was 26 degrees, at which the inside and outside surface defects with the same size and direction could be detected with the same sensitivity. The maximum permissible defects in the Zircaloy-4 tubes, i.e., the longitudinal and circumferential v notches with the length of 0.76mm and 0.38mm, respectively and the depth of 0.04 mm on the inside and outside surface, could be easily detected by the system with the inspection speed of about 1 m/min and the very excellent reproducibility. The ratio of signal to noise was greater than 20 dB for the longitudinal defects and 12 dB for the circumferential defects.

  • PDF

Out-of-pile Characteristics of Advanced Fuel Cladding (HANA alloys)

  • Park, Jeong-Yong;Park, Sang-Yun;Lee, Myung-Ho;Choi, Byung-Kwon;Baek, Jong-Hyuk;Kim, Jun-Hwan;Kim, Hyun-Gil;Jeong, Yong-Hwan;Kim, Gyu-Tae;Jung, Youn-Ho
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 2005.05a
    • /
    • pp.423-424
    • /
    • 2005
  • The performance of HANA claddings was evaluated in out-of-pile conditions. All the performance test results revealed that HANA claddings were superior to the reference claddings such as Zircaloy-4 and A-cladding. Corrosion resistance was improved by 60 to 70% compared to the commercial claddings. Creep, burst, tensile, LOCA, wear and microstructural properties were shown to be as good as the commercial claddings.

  • PDF

Evaluation of Ductility During Reactivity Initiated Accident for Zirconium Cladding using Ring Tension Test (링 인장시험을 이용한 지르코늄 피복관의 반응도 사고(RIA) 시 연성 평가)

  • Kim Jun Hwan;Lee Myoung Ho;Choi Byoung Kwon;Bang Je Geon;Jeong Yong Hwan
    • Korean Journal of Materials Research
    • /
    • v.15 no.2
    • /
    • pp.126-133
    • /
    • 2005
  • Mechanical properties of zirconium cladding were evaluated by ring tension test to simulate Reactivity-Initiated Accident (RIA) at high burnup situation as an out-reactor test. Zircaloy-4 cladding was hydrided up to 1000 ppm as well as oxidized up to $100\;{\mu}m$ to simulate high-burnup situation. After simulated high-burnup treatment, ring tension test was carried out from 0.01 to 1/sec to correlate with actual RIA event. The results showed that ductility and circumferential toughness decreased with the hydrogen content and oxide thickness. Hydride generated inside cladding acted as brittle failure. Oxygen influenced cladding tube by the reduction of load bearing area, oxygen embrittlement, and thermal aging. Correlation between in-reactor RIA parameter like fuel enthalpy and out-reactor toughness was performed and showed a reasonable result.

Effect of a surface oxide-dispersion-strengthened layer on mechanical strength of zircaloy-4 tubes

  • Jung, Yang-Il;Park, Dong-Jun;Park, Jung-Hwan;Kim, Hyun-Gil;Yang, Jae-Ho;Koo, Yang-Hyun
    • Nuclear Engineering and Technology
    • /
    • v.50 no.2
    • /
    • pp.218-222
    • /
    • 2018
  • An oxide-dispersion-strengthened (ODS) layer was formed on Zircaloy-4 tubes by a laser beam scanning process to increase mechanical strength. Laser beam was used to scan the yttrium oxide ($Y_2O_3$)-coated Zircaloy-4 tube to induce the penetration of $Y_2O_3$ particles into Zircaloy-4. Laser surface treatment resulted in the formation of an ODS layer as well as microstructural phase transformation at the surface of the tube. The mechanical strength of Zircaloy-4 increased with the formation of the ODS layer. The ring-tensile strength of Zircaloy-4 increased from 790 to 870 MPa at room temperature, from 500 to 575 MPa at $380^{\circ}C$, and from 385 to 470 MPa at $500^{\circ}C$. Strengthening became more effective as the test temperature increased. It was noted that brittle fracture occurred at room temperature, which was not observed at elevated temperatures. Resistance to dynamic high-temperature bursting improved. The burst temperature increased from 760 to $830^{\circ}C$ at a heating rate of $5^{\circ}C/s$ and internal pressure of 8.3 MPa. The burst opening was also smaller than those in fresh Zircaloy-4 tubes. This method is expected to enhance the safety of Zr fuel cladding tubes owing to the improvement of their mechanical properties.

The Accelerated and Suppressed corrosion of Zircaloy-4 Fuel Cladding in $LiOH-H_{3}BO_{3}$ Solutions ($LiOH-H_{3}BO_{3}$ 용액중 Zircaloy-4 핵연료 피복관의 부식가속과 억제)

  • Han, Jeong-Ho
    • Korean Journal of Materials Research
    • /
    • v.5 no.3
    • /
    • pp.379-386
    • /
    • 1995
  • LiOH-$H_{3}$BO_{3}$ 용액중에서의 Zircaloy-4 핵연료 피복관의 부식가속과 억제현상을 조사하고 이러한 부식특성에 미치는 Li 및 B의 영향을 해석하기 위하여, 여러 조건의 LiOH-$H_{3}$BO_{3}$ 용액을 사용하여 35$0^{\circ}C$, 165bar의 고온, 고압 조건에서 Zircaloy-4 피복관의 노외 부식시험을 수행하였다. 원전 수화학 모의조건에 대응되는 용액 중에서의 부식속도의 천이는 물 분위기에서 보다 빨리 발생되고 천이후 물 분위기와 거의 유사한 부식속도를 나타내는 천이적 후의 부식거동을 보였다. 한편 pH의 변화는 부식특성에 큰 영향을 미치지 않았다. 부식가속과 억제 모의실험으로부터, 산화막내로 침투하는 Li의 양이 용액중 Li 농도에 크게 의존하며, Li 농도가 일정하게 정해진 용액의 경우 B 첨가에 관계없이 산화막내에 일정량의 Li이 농축될수 있다는 가정을 제시하였다. 또한 B 첨가에 의한 부식억제가 B 또는 B-(OH) 화합물의 산화막내 Li 침투 억제에 의한 것이 아니라 일들에 의해 산화막내로 산화성 성분의 이동이 억제되는데 기인할 수 있음을 제시하였다. 부식가속 개시점에 대응되는 산화막 두께측정 결과와 용액내 Li 농도간의 관계로부터, 용액중 Li 농도가 높을수록 부식가속이 얇은 산화막 두께에서 시작됨을 알았다. 특히 노내조건에서의 핵연료 피복관의 부식가속이 산화막내 Li 농축에 의해 일어나는 부식특성으로 해석될 수 있음을 보였다.

  • PDF

A Study on the Iodine-induced Stress Corrosion Cracking of Zircaloy-4 Cladding (I) (지르칼로이-4 피복재의 요드응력 부식 균열에 대한 연구)

  • Ryu, W.S.;Hong, S.I.;Choi, Y.;Kang, Y.H.;Rim, C.S.
    • Nuclear Engineering and Technology
    • /
    • v.17 no.3
    • /
    • pp.193-199
    • /
    • 1985
  • Iodine-induced stress corrosion cracking tests of Zircaloy-4 cladding were undertaken using the modified infernal pressurization method. The effects of iodine concentration and applied stress were studied. The critical iodine concentration for SCC was found to be about 0.2 mg/$\textrm{cm}^2$ at 603$^{\circ}$K. The threshold stress was dependent on the test temperature and the mechanical properties of the specimen. The fracture surface showed that the crack propagated stepwise iron one grain to others until the material was unstable and then ruptured mechanically. The initial region showed the transgranular feature and the wedge-shaped cracks. As the crack proceeded, the transgranular and ductile-tearing mired feature appeared in the middle region.

  • PDF

Development of Cr cold spray-coated fuel cladding with enhanced accident tolerance

  • Sevecek, Martin;Gurgen, Anil;Seshadri, Arunkumar;Che, Yifeng;Wagih, Malik;Phillips, Bren;Champagne, Victor;Shirvan, Koroush
    • Nuclear Engineering and Technology
    • /
    • v.50 no.2
    • /
    • pp.229-236
    • /
    • 2018
  • Accident-tolerant fuels (ATFs) are currently of high interest to researchers in the nuclear industry and in governmental and international organizations. One widely studied accident-tolerant fuel concept is multilayer cladding (also known as coated cladding). This concept is based on a traditional Zr-based alloy (Zircaloy-4, M5, E110, ZIRLO etc.) serving as a substrate. Different protective materials are applied to the substrate surface by various techniques, thus enhancing the accident tolerance of the fuel. This study focuses on the results of testing of Zircaloy-4 coated with pure chromium metal using the cold spray (CS) technique. In comparison with other deposition methods, e.g., Physical vapor deposition (PVD), laser coating, or Chemical vapor deposition techniques (CVD), the CS technique is more cost efficient due to lower energy consumption and high deposition rates, making it more suitable for industry-scale production. The Cr-coated samples were tested at different conditions ($500^{\circ}C$ steam, $1200^{\circ}C$ steam, and Pressurized water reactor (PWR) pressurization test) and were precharacterized and postcharacterized by various techniques, such as scanning electron microscopy, Energy-dispersive X-ray spectroscopy (EDX), or nanoindentation; results are discussed. Results of the steady-state fuel performance simulations using the Bison code predicted the concept's feasibility. It is concluded that CS Cr coating has high potential benefits but requires further optimization and out-of-pile and in-pile testing.