• Title/Summary/Keyword: Zero crossing point

Search Result 79, Processing Time 0.026 seconds

Development of DC Circuit Breaker using Magnet Arc Extinguisher (자기적 아크소호 기법을 이용한 직류 차단기 개발)

  • Lee, Sung-Min;Kim, Hyo-Sung
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.17 no.1
    • /
    • pp.21-26
    • /
    • 2012
  • In recent years, DC distribution systems are becoming hot issue due to the increase in digital loads and DC generation systems according to the expansion of renewable energy technologies. However, removing the fault current in DC grids is comparably difficult since the current in DC grids has no zero-crossing point like in AC grids. Thus, developing dedicated DC circuit breakers for DC grids is necessary to get safety for people and electrical facilities. This paper proposes magnet arc extinguishing method to develop a 300[$V_{DC}$]/10[A] DC circuit breaker. The performance of the proposed DC circuit breaker was verified by an experimental circuit breaker test system built in this research.

A Controllable LCL-T Resonant AC/DC Converter for High Frequency Power Distribution Systems

  • Zeng, Jun;Li, Xuesheng;Liu, Junfeng
    • Journal of Power Electronics
    • /
    • v.15 no.4
    • /
    • pp.876-885
    • /
    • 2015
  • High frequency alternating current (HFAC) has been widely used in a wide range of power distribution systems (PDS) due to its superior performance. A high frequency AC/DC converter plays the role of converting HFAC voltage to DC voltage. In this paper, a new LCL-T resonant AC/DC converter has been proposed, and an easier control method based on input voltage comparison is presented, without the complicated calculation of the zero-crossing point. Both a low distortion and near-to-unity power factor can be achieved by the proposed resonant converter and control strategy. The operational principle and steady-state analysis are given for the proposed resonant converter. A simulation model and experimental prototype are implemented with an operation frequency of 25kHz and a rated power of 20W. The simulation and experimental results verify the accuracy of the analysis and the excellent performance of the proposed topology.

Research and Analysis of Difference Hybrid DC Circuit Breaker Topologies for MVDC Distribution System (MVDC 배전시스템에서 다양한 복합형 직류 차단기의 토폴로지 연구 및 분석)

  • Go, Yu-Ran;Min, Myung-Hwan;An, Tae-Pung
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.25 no.6
    • /
    • pp.503-510
    • /
    • 2020
  • The importance of DC breakers as key protection equipment is increasing in accordance with growing concerns on MVDC distribution network systems without DC/AC conversion. Different from the situation in AC systems, no natural zero-crossing point exists in DC systems. Thus, DC breaker technology is more difficult than AC breaker technology. The solutions for DC breakers can be divided into three types: mechanical, power electronics, and hybrid. In this study, the operating principles of several topologies of hybrid circuit breakers and that of the proposed DC breaker are analyzed and simulated by sorting two types. The breakers are compared in terms of the type and number of semiconductors, volume, power loss, auxiliary components, isolation, and other aspects. The advantages and disadvantages of the breakers are also analyzed.

An Integrated Single-Stage Zero Current Switched Quasi-Resonant Power Factor Correnction Converter with Active Clamp Circuit (능동 클램프 회로를 적용한 단상 ZCS 공진형 역률개선 컨버터)

  • 문건우;구관본;윤명중
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.4 no.6
    • /
    • pp.539-546
    • /
    • 1999
  • A new integrated single-stage zero current switched(ZCS) quasi resonant convertedQRC) for the IX)wer f factor correction(PFCl converter is introduced in this paper. The power factor correction can be achieved by t the discontinuous conduction mod$\varepsilon$(DCM) operation of an input current. The proposed converter has the c characteristics of the good IX)wer factor, 10씨 line current harmonics, and tight output regulation. Furthern10re, t the ringing effect due to the output capacitance of the main switch can be eliminated by use of‘ active clamp c circuit. Therefore, the proIX)sed converter is expecttc'(] to be suitable for a compact power converter with a t tightly regulated output voltage requiring a switching frequency of more than several hundrtc'(]s kHz.

  • PDF

Output Characteristic Comparison of BLDC Motor for Water Circulation System According to Sensorless Control Methods (물 순환 시스템용 BLDCM의 센서리스 제어 방식에 따른 출력 특성 비교)

  • Kim, Sung-An;Cho, Yun-Hyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.9
    • /
    • pp.1325-1333
    • /
    • 2017
  • The sensorless control of blushless DC motor(BLDCM) is based on the $120^{\circ}$ control in which the back electromotive force(Back EMF) for estimating the position of the rotor can be detected. However, the $120^{\circ}$ control has a disadvantage that the torque constant is small as compared with $180^{\circ}$ control which can not detect the back EMF. The $150^{\circ}$ control which complements these problems makes it possible to detect the back EMF and improve the torque constant by 12.5% compared to the $120^{\circ}$ control. Therefore, this paper compares the output characteristics of BLDCM through finite element method analysis (FEA) by the conventional and proposed control methods of BLDCM for water circulation system and proposes design for downsizing and weight reduction of BLDCM according to secured torque constant. The validity of the proposed control and design proposal is proved through simulation and experimental results by comparing the output characteristics of $120^{\circ}$ control and $150^{\circ}$ control.

Integrated Boost-Flyback ZCS Quasi-Resonant Power Factor Preregulator (부스트-플라이백 결합형 ZCS Quasi-Resonant 역률개선 컨버터)

  • 이준영;문건우;김현수;윤명중
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.4 no.1
    • /
    • pp.91-98
    • /
    • 1999
  • An integrated ZCS quasi-resonant converter(QRC) for the power factor correction with a single switch is presented in this paper. The power factor correction can be achieved by the discontinuous conduction mode(DCM) operation of the input current. The proposed converter gives the good power factor, low line current harmonics, and tight output regulation. The input current waveform of the prototype designed using design equations shows about 15% of total harmonic distortion at rated condition. Also, the efficiency and power factor can be obtained about 86% and 0.985, respectively, at rated condition. The proposed converter is suitable for a low power level converter with a tightly regulated low output voltage and switching frequency of more than several hundreds kHz.

  • PDF

A Study on Isolated Words Speech Recognition in a Running Automobile (주행중인 자동차 환경에서의 고립단어 음성인식 연구)

  • 유봉근
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1998.06e
    • /
    • pp.381-384
    • /
    • 1998
  • 본 논문은 주행중인 자동차 환경에서 운전자의 안전성 및 편의성의 동시 확보를 위하여, 보조적인 스위치 조작없이 상시 음성의 입, 출력이 가능하도록 한다. 이때 잡음에 강인한 threshold 값을 구하기 위하여, 일정한 시간마다 기준 에너지와 영교차율(Zero Crossing Rate)을 변경하며, 밴드패스 필터(bandpass filter)를 이용하여 1차, 2차로 나누어 실시간 상태에서 자동으로, 정확하게 끝점검출(End Point Detection)을 처리한다. 기준패턴(reference pattern)은 DMS(Dynamic Multi-Section)을 사용하며, 화자의 변별력을 높이기 위하여 2개의 모델사용을 제안한다. 또한 주행중인 차량의 잡음환경에 강인하기 위하여 일반주행(80km/h 이내), 고속주행(80km/h 이상)등으로 나누며 차량의 가변잡음 크기에 따라 자동으로 선택하도록 한다. 음성의 특징 벡터와 인식 알고리즘은 PLP 13차와 One-Stage Dynamic Programming (OSDP)를 이용한다. 실험결과, 자주 사용되는 차량 편의장치 제어명령 33개에 대하여 중부, 영동 고속도로(시속 80Km/h 이상)에서 화자독립 89.75%, 화자종속 90.08%의 인식율을 구하였으며, 경부 고속도로에서는 화자독립 92.29%, 화자종속 92.42%의 인식율을 구하였다. 그리고 저속 주행중인 자동차 환경(80km/h 이내, 시멘트, 아스팔트 등의 서울시내 및 시외독립)에서는 화자독립 92.89%, 화자종속 94.44% 인식율을 구하였다.

  • PDF

A Study on the Speech Recognition of Korean Phonemes Using Recurrent Neural Network Models (순환 신경망 모델을 이용한 한국어 음소의 음성인식에 대한 연구)

  • 김기석;황희영
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.40 no.8
    • /
    • pp.782-791
    • /
    • 1991
  • In the fields of pattern recognition such as speech recognition, several new techniques using Artifical Neural network Models have been proposed and implemented. In particular, the Multilayer Perception Model has been shown to be effective in static speech pattern recognition. But speech has dynamic or temporal characteristics and the most important point in implementing speech recognition systems using Artificial Neural Network Models for continuous speech is the learning of dynamic characteristics and the distributed cues and contextual effects that result from temporal characteristics. But Recurrent Multilayer Perceptron Model is known to be able to learn sequence of pattern. In this paper, the results of applying the Recurrent Model which has possibilities of learning tedmporal characteristics of speech to phoneme recognition is presented. The test data consist of 144 Vowel+ Consonant + Vowel speech chains made up of 4 Korean monothongs and 9 Korean plosive consonants. The input parameters of Artificial Neural Network model used are the FFT coefficients, residual error and zero crossing rates. The Baseline model showed a recognition rate of 91% for volwels and 71% for plosive consonants of one male speaker. We obtained better recognition rates from various other experiments compared to the existing multilayer perceptron model, thus showed the recurrent model to be better suited to speech recognition. And the possibility of using Recurrent Models for speech recognition was experimented by changing the configuration of this baseline model.

Sensorless Control of Brushless DC Motors Using a Frequency-Independent Phase Shifter (주파수불변 위상지연기를 사용한 BLDCM의 센서리스제어)

  • Jeong, Du-Hui;Ha, In-Jung
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.37 no.2
    • /
    • pp.85-95
    • /
    • 2000
  • This paper describes a sensorless control scheme for brushless dc motors(BLDCMs) using a phase shifter(FIPS) which can shift the zero-crossing point of the input signal with a specified amount of phase. The detection performance of the proposed FIPS is independent of the frequency of the input signal and quite robust with respect to the measurement noise. It is shown that the proposed sensorless control scheme using the FIPS is more effective in the respects of noise-robustness and cost than the previously known schemes. The generality and practicality of the proposed sensorless control scheme is demonstrated through performance analysis and experiments under various operating conditions.

  • PDF

Experiment on DC Circuit Breaker for Inductive Load by Improved Magnetic Arc-extinguisher and Arc-Attenuation Circuit (개선된 자기소호회로와 아크전압 억제회로를 사용한 유도성 부하의 직류차단 특성 실험)

  • Lee, Sung-Min;Kim, Hyo-Sung
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.17 no.6
    • /
    • pp.495-499
    • /
    • 2012
  • Recently, DC distribution systems become hot issues since DC type loads increase rapidly according to the expansion of IT equipment such as computers, servers, and digital devices; DC type loads will cover 50% for all electricity loads in 2020 which was mere 10% in 2000. DC distribution systems are also accelerated by the expansion of renewable power systems since they are easy to be interfaced with DC grids rather than AC grids. However, removing the fault current in DC grids is comparably difficult since the current in DC grids has non zero-crossing point like in AC grids. Thus, developing dedicated DC circuit breakers for DC grids is necessary to get safety for human and electrical facilities. Magnet arc extinguishing method is proper to small size DC circuit breakers. However, simple Magnet arc extinguishing method is not enough to break inductive fault currents. This paper proposed a novel DC circuit breaker against inductive fault current defined by IEEE C37.14-2004 Standard for Low-Voltage DC Power Circuit Breakers Used in Enclosures. The performance of the proposed DC circuit breaker was verified by an experimental circuit breaker test system built in this research.