A new interleaved high step up converter with low voltage stress on the main switches

  • Tohidi, Babak;Delshad, Majid;Saghafi, Hadi
    • Smart Structures and Systems
    • /
    • 제26권4호
    • /
    • pp.521-531
    • /
    • 2020
  • In this paper, a new interleaved high step-up converter with low voltage stress on the switches is proposed. In the proposed converter, soft switching is provided for all switches by just one auxiliary switch, which decreases the conduction loss of auxiliary circuit. Also, the auxiliary circuit is expanded on the converter with more input branches. In the converter all main switches operate under zero voltage switching condition and auxiliary switch operate under zero current switching condition. Because of the interleaved structure, the reliability of converter increases and input current ripples decreases. The clamp capacitor in the converter not only absorb the voltage spikes across the switch due to leakage inductance, but also improve voltage gain. The proposed converter is fully analyzed and to verify the theoretical analysis, a 100 W prototype was implemented. Also, to show the effectiveness of auxiliary circuit on conduction EMI, EMI of the proposed converter comprised with hard switching counterpart.

단일 보조 스위치를 이용한 새로운 ZVZCS PWM DC-DC 컨버터 (New ZVZCS PWM DC-DC Converters with One Auxiliary Swithch)

  • 류승희;이동윤;유상봉;현동석
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제49권3호
    • /
    • pp.188-194
    • /
    • 2000
  • This paper presents new Zero-Voltage-/Zero-Current-Switching (ZVZCS) PWM DC-DC converters. The proposed soft-switching technique achieves ZVS and ZCS simultaneously at both turn-on and turn-off of the main switch and diode by using only one auxiliary switch. Also, the proposed soft-switching technique is suitable for not only minority but also majority carrier semiconductor devices. The auxiliary circuit of the proposed topology is placed out the main power path and therefore, there are no voltage/current stresses on the main switch and diode. The operating principle of the proposed topology is illustrated by a detailed study with a boost converter as an example. Theoretical analysis, simulation and experimental results are presented to explain the proposed schemes.

  • PDF

새로운 영전류영전압 스위칭 승압 DC-DC 컨버터의 성능 해석 (A NOVEL SOFT-SWITCHING BOOST-TYPE PWM CONVERTER TOPOLOGY)

  • 한병문;백승택;김재홍;김현우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부A
    • /
    • pp.153-155
    • /
    • 1998
  • A novel soft-switching pulse-width modulated boost-type DC-DC converter topology is presented in this paper. The conventional boost switch is replaced by a switching cell that is comprised of two switch-diode pairs being linked by an inductor for zero-current switching turn-on. The diodes commutate the current that is flowing through the soft-switching inductor when the two switch turn-off. The capacitor is placed in parallel with the two switches during turn-off, thus providing zero-voltage switching turn-off. Simulation results are presented to support the theoretical considerations.

  • PDF

Active CDS-Clamped L-Type Current-Fed Isolated DC-DC Converter

  • Nguyen, Minh-Khai;Duong, Truong-Duy;Lim, Young-Cheol;Choi, Joon-Ho
    • Journal of Power Electronics
    • /
    • 제18권4호
    • /
    • pp.955-964
    • /
    • 2018
  • In this paper, an active capacitor-diode-switch (CDS) snubber is proposed for L-type current-fed isolated DC-DC converters. The proposed CDS-clamped converter has a number of advantages. It can achieve wide range zero-voltage switching (ZVS) on two switches, a continuous input current with a low ripple, a reduction of one active switch and high efficiency. The operating principles, analysis and parameter design guideline are presented. A 300 W prototype is built to test the proposed converter. Simulation and experimental results are shown at 30 V input voltage and 400 V output voltage.

간이 스위칭법에 의한 단상 역률개선형 컨버터 (The Single Phase Converter of Power Factor Collection Type with Simple Switching Method)

  • 문경희;고강훈;김은수;곽동걸;조판제;이현우
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1999년도 전력전자학술대회 논문집
    • /
    • pp.323-326
    • /
    • 1999
  • For decrease the harmonic current components of the power source, a first method is insert the choke coil that used the choke input type rectifier, the booster chopper circuit and buck chopper circuit. And the several method are studying like as the PWM(Pulse Width Modulation) converter and the active filter type which is used the high frequency switching and the sinusoidal wave formed input current. In this type, there are many problem as a low efficiency, increased the noise, the high leakage current and cost up by the high frequency switching. For improve this problems, the partial resonan method is used on the booster inducter and lossles snubber condenser. This method decreased the distortion factor has lower harmonic components than the hard switching and there is no switching loss by the ZCS(Zero Current Switching) at switch turn-on and the ZVS(Zero Voltage Swithcing) at switch turn-off

  • PDF

능동 클램프 회로를 적용한 단상 ZCS 공진형 역률개선 컨버터 (An Integrated Single-Stage Zero Current Switched Quasi-Resonant Power Factor Correction Converter with Active Clamp Circuit)

  • 이준영;문건우;고관본;윤명중
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1999년도 전력전자학술대회 논문집
    • /
    • pp.626-630
    • /
    • 1999
  • A new integrated single-stage zero current switched(ZCS) quasi-resonant converter (QRC) for the power factor correction(PFC) converter is introduced in this paper. The power factor correction can be achieved by the discontinuous conduction mode(DCM) operation of an input current. The proposed converter has the characteristics of the good power factor, low line current harmonics, and tight output regulation. Furthermore, the ringing effect due to the output capacitance of the main switch can be eliminated by use of active clamp circuit.

  • PDF

Optimal Soft-Switching Scheme for Bidirectional DC-DC Converters with Auxiliary Circuit

  • Lee, Han Rim;Park, Jin-Hyuk;Lee, Kyo-Beum
    • Journal of Power Electronics
    • /
    • 제18권3호
    • /
    • pp.681-693
    • /
    • 2018
  • This paper proposes a soft-switching bidirectional dc-dc converter (BDC) with an auxiliary circuit. The proposed BDC can achieve the zero-voltage switching (ZVS) using an auxiliary circuit in the buck and boost operations. The auxiliary circuit supplies optimal energy for the ZVS operation of the main switches. The auxiliary circuit consists of a resonant inductor, a back-to-back switch and two capacitors. A small-sized resonant inductor and an auxiliary switch with a low-rated voltage can be used in the auxiliary circuit. Zero-current switching (ZCS) turn-on and turn-off of the auxiliary switches are possible. The proposed soft-switching scheme has a look-up table for optimal switching of the auxiliary switches. The proposed strategy properly adjusts the turn-on time of the auxiliary switch according to the load current. The proposed BDC is verified by the results of PSIM simulations and experiments on a 3-kW ZVS BDC system.

동기 스위치 제어를 통한 영전압 동작 고효율 능동 클램프 포워드 컨버터 (High Efficiency Active Clamp Forward Converter with Synchronous Switch Controlled ZVS Operation)

  • 이성세;최성욱;문건우
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2005년도 전력전자학술대회 논문집
    • /
    • pp.266-268
    • /
    • 2005
  • A new synchronous switch controlled transient current build-up zero voltage switching (TCB-ZVS) forward converter is proposed. The proposed converter is suitable for the low-voltage and high-current applications. The features of the proposed converter are low conduction loss of magnetizing current, no additional circuit for the ZVS operation, high efficiency, high power density and low EMI noise throughout all load conditions.

  • PDF

ZCS 보조회로를 이용한 ZVT Boost 컨버터에 관한 연구 (A Study on ZVT Boost Converter Using a ZCS Auxiliary Circuit)

  • 류동균;이우석;최태영;서민성;원충연;김영렬
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 추계학술대회 논문집
    • /
    • pp.129-132
    • /
    • 2001
  • Recently, a ZVT boost converter is embedded in a power factor correction system. The control circuit of the converter assures soft-switching for all the MOSFETs and load regulation. The PFC system contains additional control circuits which assure the input voltage in a sinusoidal form and feed-forward line voltage regulation. In this paper, a soft switching boost converter with zero-voltage transition(ZVT) main switch using zero-current switching(ZCS) auxiliary switch is proposed. Operating intervals of the converter are persented and analyzed. The proposed results show that the main switch maintains UT while auxiliary switch retains ZCS for the complete specified line and load conditions.

  • PDF

소프트 스위칭 방식의 보조 회로를 갖는 영전류 및 영전압 스위칭 양방향 DC-DC 컨버터 (A Family of Zero Current and Zero Voltage Switching Bidirectional DC-DC Converter with Soft Switched Auxiliary Circuit)

  • 이일호;김준구;김재형;원충연;정용채
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2011년도 전력전자학술대회
    • /
    • pp.438-439
    • /
    • 2011
  • In this paper, soft switching bidirectional DC-DC converter is proposed. The proposed topology is added two auxiliary switches, two resonant capacitors and one resonant inductor to convectional bidirectional DC-DC converter. Therefore, this proposed topology can reduce switching loss of each power switch by ZVS (Zero Voltage Switching) and ZCS (Zero Current Switching). We have performed mode analysis, simulation and experiment for the proposed topology.

  • PDF