• Title/Summary/Keyword: Zemax

Search Result 30, Processing Time 0.025 seconds

Development of Ftheta Lens for Laser Scanning Unit (Laser Scanning Unit용 FΘ 렌즈 개발)

  • Jeong, In-Sook;Ban, Min-Sung;Son, Kwang-Eun;Lee, Byoung-Bag
    • Transactions of the KSME C: Technology and Education
    • /
    • v.1 no.1
    • /
    • pp.13-19
    • /
    • 2013
  • Ftheta Lens, whose image height is proportional to its field view angle, is one of the most important parts in Laser Scanning Unit(LSU). In this paper $f{\theta}$ lens design, mold production and modification method of lens design and mold are introduced. Lens design was carried out with Zemax and Special Toric surfaces were applied for lens surfaces to minimize distortion both in main and sub scanning directions. And a high precision machine with 1nm resolution was used to fabricate lens mold cores. After injection the lens was evaluated and the difference from design was examined. This difference was compensated by modifying lens design and new lens mold cores were made according to modified lens design to obtain the quality of original design.

Focal Reducer for McDonald Otto Struve Telescope

  • Lim, Ju-Hee;Kim, Young-Ju;Park, Won-Kee;Kim, Jin-Young;Chang, Seung-Hyuk;Pak, Soo-Jong;Im, Myung-Shin
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.35 no.1
    • /
    • pp.36.2-36.2
    • /
    • 2010
  • The CQUEAN (Camera for QUasars in EArly uNiverse) is an optical CCD camera optimized for observation of high redshift objects. It is going to be attached to the cassegrain focus of 2.1m telescope at McDonald Observatory, USA. We are making a focal reducer for CQUEAN to secure a larger field of view. The focal reducer is composed of four spherical lens, and it reduces the focal length of telescope by one third. We designed the lens configuration, performed tolerance analysis, and estimated the optical performance with ZEMAX. The differences in optical performace with/without filters were also investigated. The result from ZEMAX shows that the system has ample margin of errors for median seeing of 1.2" at McDonald observatory. Even with aberration and alignment tolerance, the performance is better than the original requirement. The lenses are now being made, and the lens barrel and an adapter for assembly of the Andor CCD camera and the filter wheel is now under designing process. We expect that the manufacturing of the focal reducer system as well as its optical test will be finished by April 2010.

  • PDF

Effect of Flow Field and Detection Volume in the Optical Particle Sensor on the Detection Efficiency (광학입자센서 내 유동장과 측정영역이 측정효율에 미치는 영향)

  • Kim, Young-Gil;Jeon, Ki-Soo;Kim, Tae-Sung
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.3162-3167
    • /
    • 2007
  • The OPS (Optical Particle Sensor) using light scattering from the particles (real-time measurement without physical contact to the particles) can be used for cleanroom or atmospheric environment monitoring. For particles smaller than 300 nm, the detection efficiency becomes lower as scattered light decreases with particle size. To obtain higher detection efficiency with small particles, the flow field in particle chamber and the detection volume should be designed optimally to achieve maximum scattered light from the particles. In this study, a commercial computational fluid dynamics software FLUENT was used to simulate the gas flow field and particle trajectories with various optical chamber designs for 300 nm PSL particle. For estimation of laser viewing volume, we used a commercial computational optical design program ZEMAX. The results will be a great help in the development of OPS which can measure small particles with higher detection efficiency.

  • PDF

Development of an Optical Payload Virtual Image Generator (광학 탑재체 가상영상 생성기 개발)

  • Lee, Jong-Hun;Lee, Jun-Ho;Kim, Hui-Seop
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2009.02a
    • /
    • pp.365-366
    • /
    • 2009
  • 본 논문에서 개발된 시뮬레이터는 광학 탑재체의 성능예측에 있어 지배적인 영향을 미치는 MTF인자 및 PSF인자들을 수치해석프로그램인 MATLAB 상에서 계산하였다. 또한 광학해석 프로그램인 ZEMAX를 연동하여 광학계의 가공, 제조 그리고 정렬할 때 발생할 수 있는 오차들을 적용 수 있다. 이를 통하여 광학탑재체의 운용상 발생하는 Jitter, Smear, Detector sampling, Detector diffusion등의 MTF를 쉽게 구할 수 있으며 여기에 광학계 제조상의 문제를 직접 적용할 수 있다. 그 결과 이를 영상에 넣어 가상영상을 생성하여 광학 탑재체 성능 예측을 효율적으로 수행할 수 있게 되었다.

  • PDF

Effect of the Liquid Density Difference on Interface Shape of Double-Liquid Lens

  • Kong, Meimei;Zhu, Lingfeng;Chen, Dan;Liang, Zhongcheng;Zhao, Rui;Xu, Enming
    • Journal of the Optical Society of Korea
    • /
    • v.20 no.3
    • /
    • pp.427-430
    • /
    • 2016
  • The effect of the liquid density difference on interface shape of a double-liquid lens is analyzed in detail. The expressions of interface shape of two liquids with liquid density difference are analyzed and fitted with “even asphere”. The imaging analysis of the aspheric interface shape of a double-liquid lens is presented. The results show that the density difference of two liquids can cause the interface to be an aspheric surface, which can improve the image quality of a double-liquid lens. The result provides a new selection for the related further research and a wider application field for liquid lenses.

Development of an Optical Payload Simulator for KOMPSAT-3 (다목적실용위성3호의 광학 탑재체 시뮬레이터 개발)

  • Kim, Yeong-Geun;Lee, Jun-Ho;Lee, Chi-Won;Kim, Hui-Seop
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2008.02a
    • /
    • pp.69-70
    • /
    • 2008
  • 본 논문은 광학 탑재체 성능의 MTF 예측에 있어, 광학 해석 프로그램인 ZEMAX와 MATLAB으로 구현된 기본 광학계 성능 해석 모델을 하나의 통합적인 툴 체계로 구현하였다. 그 결과 광학 탑재체 성능 해석에 광학계 설계, 제작/조립 및 궤도 상에서의 오차를 직접 반영할 수 있게 되었고 광학 탑재체의 초기 설계 단계에서 주요 설계인자를 도출하고, 지배적인 영향을 미치는 입력변수와 설계 요소들을 활용하여 광학 탑재체의 성능 예측을 수행할 수 있는 효율적이고 체계적인 틀을 개발하였다.

  • PDF

Design and Experimental Demonstration of Coaxially Folded All-reflective Imaging System

  • Xiong, Yupeng;Dai, Yifan;Chen, Shanyong;Tie, Guipeng
    • Current Optics and Photonics
    • /
    • v.3 no.3
    • /
    • pp.227-235
    • /
    • 2019
  • With slimmer, lighter and all-reflective imaging systems in high demand for consumer and military applications, coaxially folded optical image systems are widely considered because they can extend focal length and reduce track length. Most of these systems consist of multiple surfaces, and these surfaces are machined on one element or grouping processing on two elements. In this paper, we report and first experimentally demonstrate an all-aluminum all-reflective optical system which consists of two optical elements, with two high order aspherical surfaces in each element. The coaxially folded system is designed with Seidel aberration theory and advanced optimization with Zemax. The system is made of all-aluminum material processing by single point diamond turning (SPDT). On this basis, we completed the system integration and performed an imaging experiment. The final system has the advantages of short track length and long focal length and broad application prospects in the micro-unmanned aerial vehicle field.

Development Process for High Power Diode Laser for Metal Surface Hardening (금속 표면경화용 고출력 다이오드 레이저 개발 프로세스)

  • Jang, Dong-Hwan
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.21 no.2
    • /
    • pp.11-22
    • /
    • 2022
  • This paper presents the development process for a high-power diode laser for metal surface hardening. To combine the emissions from several laser bars, it is necessary to collimate the emitted light using an optical lens. Thus, to achieve a suitable power density and uniform beam profile, several optical layouts were proposed. To estimate the laser beam for a flat-top distribution, a numerical analysis was performed using the ZEMAX software, and the results were compared with the experimental results. With a focal lens assembled in a serial diode stack source, the design can utilize the advantage of compacting the overall beam size. Experimental results for a robotic system demonstrated the processing ability of this diode laser module in industrial laser hardening.

Development of a MTF Measurement System for an Infrared Optical System (적외선 광학계용 MTF 측정장치 개발)

  • Son, Byoung-Ho;Lee, Hoi-Yoon;Song, Jae-Bong;Yang, Ho-Soon;Lee, Yun-Woo
    • Korean Journal of Optics and Photonics
    • /
    • v.26 no.3
    • /
    • pp.162-167
    • /
    • 2015
  • In this paper, we developed a MTF (Modulation Transfer Function) measurement system using a knife-edge scanning method for infrared optics. It consists of an objective part to generate the target image, a collimator to make the beam parallel, and a detector to analyze the image. We used a tungsten filament as the light source and MCT (Mercury Cadmium Telluride) to detect the mid-infrared(wavelength $3-5{\mu}m$) image. We measured the MTF of a standard lens (f=5, material ZnSe) to test this instrument and compared the result to the theoretical value calculated using the ZEMAX commercial software. It was found that the difference was within ${\pm}0.035$ at the cut-off frequency (50 1/mm). Also, we calculated the A-type measurement uncertainty to check the reliability of the measurement. The result showed only 0.002 at 20 1/mm in spatial frequency, which means very little variation in the MTF measurement under the same conditions.

Studies on Curved Diffractive Optical Elements in EUV (극자외선 영역에서 곡면 DOEs에 관한 연구)

  • Choi, Sung-Eul;Lee, Yong-Woo;Kwon, Myung-Hoi;Kim, Yong-Hoo
    • Korean Journal of Optics and Photonics
    • /
    • v.16 no.4
    • /
    • pp.304-312
    • /
    • 2005
  • Field performance of several different types of diffractive optical elements(DOEs) has been carried out. Using Zemax model, we have designed five different types of DOEs, such as transmissive flat-DOE, transmissive curved-DOE, reflective flat-DOE, reflective curved-DOE and parabolic mirror, We have applied two different wavelengths, i.e., 13 m(EUV) and 632.8 nm(visible) to above DOEs. Off_axis dominate aberrations and the diffraction limiting (Rayleigh limit) field angles have been investigated and compared at both wavelengths for each DOE. At diffraction limit, field angle of curved-DOEs was much greater than that of flat-DOEs for both transmission and reflective types. We also showed that dominated off_axis aberration of flat-DOEs was coma, but that of curved-DOEs was mixture of astigmatism and curvature of field. The measured field angle and expected OPD aberrations were well coincided with theoretical ones. Increasing the ratio of field angle with wavelength was more effective in curved-DOEs than flat-DOEs.