• Title/Summary/Keyword: Z-value

Search Result 1,111, Processing Time 0.041 seconds

Quality Assurance Program of Electron Beams Using Thermoluminescence Dosimetry (열형광선량계를 이용한 전자선 품질보증 프로그램에 관한 연구)

  • Rah Jeong-Eun;Kim Gwe-Ya;Jeong Hee-Kyo;Shin Dong-Oh;Suh Tae-Suk
    • Progress in Medical Physics
    • /
    • v.16 no.2
    • /
    • pp.62-69
    • /
    • 2005
  • The purpose of this study has been performed to investigate the possibility of external audit program using thermoluminescence dosimetry for electron beam in korea. The TLD system consists of LiF powder, type TLD-700 read with a PCL 3 reader. In order to determine a calibration coefficient of the TLD system, the reference dosimeters are irradiated to 2 Gy in a $^{60}CO$ beam at the KFDA The irradiation is performed under reference conditions is water phantom using the IAEA standard holder for TLD of electron beam. The energy correction factor is determined for LiF powder irradiated of dose to water 2 Gy in electron beams of 6, 9, 12, 16 and 20 MeV (Varian CL 2100C). The dose is determined according to the IAEA TRS-398 and by measurement with a PTW Roos type plane-parallel chamber. The TLD for each electron energy are positioned in water at reference depth. In this study, to verify of the accuracy of dose determination by the TLD system are performed through a 'blind' TLD irradiation. The results of blind test are $2.98\%,\;3.39\%\;and\;0.01\%(1\sigma)$ at 9, 16, 20 MeV, respectively. The value generally agrees within the acceptance level of $5\%$ for electron beam. The results of this study prove the possibility of the TLD quality assurance program for electron beams. It has contributed to the improvement of clinical electron dosimetry in radiotherapy centers.

  • PDF

Accumulation of Heavy Metals(Cd, Cu, Zn, and Pb) in Five Tree Species in Relation to Contamination of Soil near Two Closed Zinc-Mining Sites (아연폐광산(亞鉛廢鑛山) 주변(周邊) 토양(土壤)의 중금속(重金屬) (Cd, Cu, Zn, Pb) 오염(汚染)에 따른 5개(個) 수종(樹種)의 부위별(部位別) 중금속(重金屬) 축적(蓄積))

  • Han, Sim Hee;Hyun, Jung Oh;Lee, Kyung Joon;Cho, Duck Hyun
    • Journal of Korean Society of Forest Science
    • /
    • v.87 no.3
    • /
    • pp.466-474
    • /
    • 1998
  • This study was conducted to evaluate heavy metal concentrations(Cd, Cu, Z, and Pb) in the soil of two zinc mines and to correlate heavy metal contents between the soils and trees growing near the mines. Soils and leaves, stems, and roots of five tree species(Corylus heterophylla, Pinus rigida. Populus alba${\times}$glandulosa, Rhododendron mucronulatum, and Robinia pseudoacacia) were collected from Sambo Zinc Mine located in Hwasung and Gahak Zinc Mine in Kwangmyung city in Kyonggido. Soils near two zinc mines were not seriously contaminated by heavy metals, but Zn and Pb concentrations were at toxic level. The heavy metal concentration in soils decreased in the order of Zn, Pb, Cu, and Cd, and decreased with increasing distance from zinc mining sites. Among the five tree species, Populus alba ${\times}$ glandulosa showed the highest heavy metal concentrations in the tissue except for Pb. Particulars, leaves of the species contained the high concentrations of heavy metals to reach the maximum of 91ppm Zn. The roots of Corylus heterophylla contained high concentrations of Cu and Pb. The order of heavy metal concentrations in the tree species was Zn, Cu, Pb and Cd. The concentration of heavy metals in the tree tissues showed a positive correlation with that in soil in which trees are growing. The ratio of heavy metal concentration of trees to that of soils(concentration factor : CF) was highest in Zn and lowest in Pb. Populus alba${\times}$glandulosa had the highest CF value among the five tree species. It was concluded that Populus alba${\times}$glandulosa, based on the high metal uptake ability, could be used for decontaminating of heavy metals from contaminated soils, and Pinus rigida could be used to reflect the level of contamination in soils.

  • PDF

A Study on the Forest Vegetation and Soil-environmental Factors Affecting the Water Quality of Iwonch on Stream (이원천 수질에 미치는 삼림식생과 토양환경요인)

  • Bang, Je-Yong;Yang, Keum-Chul
    • Korean Journal of Environmental Biology
    • /
    • v.27 no.2
    • /
    • pp.183-190
    • /
    • 2009
  • Characterization of the analysis of forest vegetation, soil environmental conditions and water quality were performed from March 2003 to March 2007. The two basins were characterized by cultivated area (Kaesim reservoir) and mountain area (Jangchan reservoir), and divided into eleven small basins, where dynamics of pollutants, forest vegetation and soil environmental conditions were surveyed. The vegetation can be divided into 10 types by $Z\ddot{u}rich$-Montpellier school's method. Pearson coefficients between vegetation type and water quality were correlated with dissolved oxygen (DO) in the Quercus variabilis community at the 5% level and total phosphorus (TP) in the Larix leptolepis plantation at the 1% level. Especially total phosphorous and total nitrogen increased in small basins where the proportion of cultivated and residential area increased. The analysis of influences of pollutant discharge on water quality showed that pollutant charge was very low in forest land area ($Y_{T-P}$=-0.0017X+0.2215, r=0.16, $Y_{COD}$=- 0.0395X+8.5051 r=0.47). The soil types of western area were comparatively simple, but those of eastern area were complicated with regosols, red-yellow soils, lithosoles, etc. The pH, total solid (TS) and volatile substance (VS) of the forest and agricultural land soils collected in each site were 5.4~6.9, 75.8~80.2%, and 3.80%~5.80%, respectively. According to the analytical result of soil environmental conditions, heavy metal contents fell short to the mean value of natural conditions. Runoff amount (Y) and depth of topsoil (X) were negatively correlated, $Y_{ron}=-1.0088X_{top}+35.378$ (r=0.68). The correlation was much lower in up-stream but much higher in down-stream, because permeation into soil particle was larger on down-stream due to its more or less gentle slope. Pearson coefficients between soil pH and water pH were statistically significant at 1% level.

Community Structure of Forest Vegetation in Mt. Geumsusan belong to Woraksan National Park (월악산국립공원 금수산 산림식생의 군집구조)

  • Kim, Ho-Jin;Shin, Jae-Kwon;Lee, Cheol-Ho;Yun, Chung-Weon
    • Korean Journal of Environment and Ecology
    • /
    • v.31 no.2
    • /
    • pp.202-219
    • /
    • 2017
  • The purpose of this study was to analyze the community structure of forest vegetation in Mt. Geumsusan belong to Woraksan National Park for providing basic information of ecological management. Data were collected by 41 plots from June to November in 2016 using Z-M phytosociology method, which was analyzed with vegetation types, mean importance value and coincidence method. As the results, the forest vegetation was classified into Quercus mongolica community group including Cornus controversa community, Castanea crenata community(Vegetation unit 3), Quercus variabilis community(Vegetation unit 4) and Q. mongolica community(Vegetation unit 5). C. controversa community was divided into two groups such as Ulmus davidiana var. japonica group(Vegetation unit 1) and Parthenocissus tricuspidata group(Vegetation unit 2). Mean importance percentage of vegetation unit 1 was showing Fraxinus rhynchophylla 14.9%, Morus bombycis 8.7% and Acer pictum subsp. mono 8.3%, that of unit 2 was Larix kaempferi 23.2%, C. controversa 20.1% and P. tricuspidata 6.5%, that of unit 3 was Q. mongolica 15.8%, C. crenata 13.4% and F. rhynchophylla 9.8%, that of unit 4 was Q. mongolica 26.6%, Q. variabilis 20.8% and Pinus densiflora 16.7%, that of unit 5 was Q. mongolica 48.3%, Styrax obassia 7.5%, F. rhynchophylla 5.3% in the order, respectively. Each vegetation unit was classified with dependance on environmental factors as 700m of altitude, $20^{\circ}$ of slope degree, middle slope of topography, 20% of bare rock, 30 taxa of present species, 80% of tree layer coverage rate and 20m of tree layer height. In conclusion, it was preferentially considered that development of peculiar and specific management methods with vegetation unit classified above should be needed for ecological and sustainable forest vegetation management.

A Study on Rail Vibration and Its Reduction Plan in Central Daejeon Area (대전 도심지역의 철도진동의 영향과 대책)

  • Ryu, Myoung-Ik;Suh, Man-Cheol;Lee, Won-Kook
    • Journal of the Korean Geophysical Society
    • /
    • v.3 no.4
    • /
    • pp.269-280
    • /
    • 2000
  • Rail vibration in city zone is becoming a serious environmental problem. In order to make a reduction plan for rail vibration, the research was conducted in which many experiments to measure actual rail vibration along the railroad through the central Deajeon area. A digital vibration level meter was used to measure rail vibration. Vibration levels of Z-axis were measured at every second for the duration of the train passing. The measuring station was placed at every 5m for the distance of 55m. A total of 353 different sets of vibration level were obtained. The signals were processed to get $L_{10}$ value and analyzed in terms of distance, train velocity, and number of trains. As a result, it has been found that rail vibration exceed the allowable vibraton limit of 60 dB, at the point of 25 m far from the railroad center, which is regulated by the las of vibration and noise. Train velocity was found to affect a little for vibration level within the zone. It was also found that a trench installed along a railroad could reduce vibration level up to approximately 10 percent. A model test was conducted to investigate the influence of the location and size of trench, on the transfer of vibration. A heavy steel ball was used to generate vibrations. On the basis obtained from this study, it could be concluded that the application of distance-attenuation and the installment of a trench along railroad could be applied as a reduction plan for rail vibration. Because limitions might exist to depend on the effect of distance attenuation, trenchs excavated along a railroad might be suggested as the most efficient solution to reduce railroad vibration.

  • PDF

The Impact on Fish Assemblage by the River Connectivity Fragmentation: Case Study of the Danjang Stream, South Korea (하천 연속성 단절이 어류상에 미치는 영향: 밀양 단장천을 중심으로)

  • Seung-Been Heo;Kang-Hui Kim;Donghyun Hong;Hyeon-Sik Lee;Gu-Yeon Kim;Gea-Jae Joo;Hyunbin Jo
    • Korean Journal of Ecology and Environment
    • /
    • v.55 no.3
    • /
    • pp.231-243
    • /
    • 2022
  • Anthropogenic disturbances on freshwater ecosystem are known to degrade biodiversity, especially on fish assemblage. In this study, we have conducted fish surveys to identify impact of a bridge construction on fish assemblages. A total of eight study sites were surveyed in the Danjang and the Dong Stream in southern part of South Korea from June to November in 2021. The fish samplings were carried out five times, using cast-nets(10×10 mm mesh size), scoop-nets(4×4 mm, 5×5 mm mesh size), set-nets (10×10 mm mesh size), and fish traps (3×3 mm mesh size), along with the Stream/River Ecosystem Survey and Health Assessment by the Ministry of Environment of Korea and basic water quality measurement. Also, we applied the species diversity index and length-weight relationship regressions on certain species to identify interspecific growth rate differences in accordance with study sites. As a result, a total of 782 individuals, 23 species and 10 families were collected. The dominant species was Zacco Koreanus and relative abundance was 50.89%. When applying the length-weight relationship regressions on certain species, the 'b' value for Z. Koreanus was lower at the downstream points than at the upstream points of the construction site. In addition, when comparing to the results of the past survey, relative density of demersal fish at the upstream and downstream points decreased from 26% to 1.4%, and from 18% to 6.3%, respectively. In conclusion, it is considered that bridge construction negatively affects the habitat of fishes, especially on demersal fishes. Therefore, appropriate conservation efforts such as installation of silt protector and sand sedimentation pond are needed to alleviate the disturbance in habitat such as occurrence of turbidity and destruction of micro-habitats.

Evaluation of the effect of a Position Error of a Customized Si-Bolus Produced using a 3D-Printer: Cervical Cancer Radiation Treatment (3D 프린터를 이용하여 제작한 맞춤형 Si-Bolus의 위치 오차 효과 평가: 자궁경부암 방사선 치료)

  • Seong Pyo Hong;Ji Oh Jeong;Seung Jae Lee;Byung Jin Choi;Chung Mo Kim;Soo Il Jung;Yun Sung Shin
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.35
    • /
    • pp.7-13
    • /
    • 2023
  • Purpose: In this study, we evaluated the effect of using a customized bolus on dose delivery in the treatment plan when cervical cancer protruded out of the body along with the uterus and evaluated reproducibility in patient set-up. Materials & Methods: The treatment plan used the Eclipse Treatment Planning System (Version 15.5.0, Varian, USA) and the treatment machine was VitalBeam (Varian Medical Systems, USA). The radiotherapy technique used 6 MV energy in the AP/PA direction with 3D-CRT. The prescribed dose is 1.8 Gy/fx and the total dose is 50.4 Gy/28 fx. Semiflex TM31010 (PTW, Germany) was used as the ion chamber, and the dose distribution was analyzed and evaluated by comparing the planned and measured dose according to each position movement and the tumor center dose. The first measurement was performed at the center by applying a customized bolus to the phantom, and the measurement was performed while moving in the range of -2 cm to +2 cm in the X, Y, and Z directions from the center assuming a positional error. It was measured at intervals of 0.5 cm, the Y-axis direction was measured up to ±3 cm, and the situation in which Bolus was set-up incorrectly was also measured. The measured doses were compared based on doses corrected to CT Hounsfield Unit (HU) 240 of silicon instead of the phantom's air cavity. Result: The treatment dose distribution was uniform when the customized bolus was used, and there was no significant difference between the prescribed dose and the actual measured value even when positional errors occurred. It was confirmed that the existing sheet-type bolus is difficult to compensate for irregularly shaped tumors protruding outside the body, but customized Bolus is found to be useful in delivering treatment doses uniformly.

  • PDF

Packing effects on the intracavitary radiation Therapy 3-Dimension plan of the uterine cervix cancer (자궁경부암 강내조사 3차원 치료계획 시 Packing의 유용성 분석)

  • Si, Chang-Keun;Jo, Jung-Kun;Lee, Du-Hyun;Kim, Sun-Yeung;Kim, Tae-Yoon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.17 no.1
    • /
    • pp.1-8
    • /
    • 2005
  • Purpose : An effect of a packing to uterine treatment of a cervical cancer using a dose-volume histogram for a point dose and a volume dose of the bladder and the rectum was analyzed by establishing a three-dimensional treatment plan using a CT image. Materials and methods : Reference points of the bladder and the rectum were marked, respectively at a treatment plan device (plato brachytherapy V14.2.4) by photographing CT(marconi, USA) when the packing was used and removed under the same condition and a treatment plan was performed to Apoint depending on ICRU38. However, in case of the rectum, a maximum point was looked up and compared with the above point because the point presented from the ICRU is not proper as a representative value of a rectum point dose. Further, the volume dose depending on volume of $50\%,\;80\%,\;and\;100\%$ point doses of the rectum and the bladder was measured. The measured values were used to analyze the effect of the packing through a Wilcoxon Signed Rank Test (a SAS statistical analysis process program). Result : The reference points at the bladder and rectum doses when the packing was removed were $116.94\;35.42\%$ and $117.59\;21.08\%$, respectively. The points when the packing was used were $107.08\;38.12\%$ and $95.19\;21.32\%$, respectively. After the packing was used, the reference points at the bladder and the rectum were decreased by $9.86\%$ and $22.4\%$, respectively. When the packing was removed, the maximum points at the bladder and the rectum were $164.51\;50.89\%,\;128.81\;33.05\%$, respectively. When the packing was used, the maximum points at the bladder and the rectum were $142.31\;44.79,\;110.08\;37.03\%$, respectively. After the packing was used, the maximum points at the bladder and the rectum were decreased by $22.2\%$ and $18.73\%$, respectively. When the packing was removed, the bladder volume at $50\%,\;80\%,\;and\;100\%$ point doses of the rectum and the bladder were $48.62{\pm}18.09\%,\;16.12{\pm}11.15\%,\;and\;7.51{\pm}6.63\%$, respectively and its rectum volume were $23.41{\pm}14.44\%,\;6.27{\pm}4.28\%,\;2.79{\pm}2.27\%$, respectively. When the packing was used, the bladder volume at $50\%,\;80\%,\;and\;100\%$ point doses of the rectum and the bladder were $40.33{\pm}16.72,\;11.63{\pm}8.72,\;and\;4.87{\pm}4.75\%$, respectively and its rectum volume were $18.96{\pm}8.37\%,\;4.75{\pm}2.58\%,\;and\;1.58{\pm}1.06\%$, respectively. After the packing was used, the bladder volume at $50\%,\;80\%,\;and\;100\%$ point doses of the rectum and the bladder were decreased by $8.29\%,\;4.49\%,\;and\;2.64\%$, respectively and its bladder volume were decreased by $4.45\%,\;1.52\%,\;and\;1.21\%$, respectively. Conclusion : Values at Reference point doses of the bladder and the rectum recommended from the ICRU 38 were 0.0781 and 0.0781, respectively and values of their maximum point doses were 0.0156 and 0.0156, respectively, as a result of which an effect of the packing using at the uterine intracavitary treatment of an uterine cervical cancer through the three-dimensional treatment plan used CT were measured. That is, the values at reference point doses and the values at maximum point doses show similar difference. However, P value was 0.15 at over $50\%,\;80\%,\;and\;100\%$ volume doses and the value shows no similar difference. In other words, the effect of the packing looks like having a difference at the point dose, but actually shows no difference at the volume dose. The reason is that the volume of the bladder and the rectum are wide but the volume of the packing is only a portion. Therefore, the effect of decreasing the point dose was not great. Further, the farer the distance is, the more weak the intensity of radiation is because the intensity of radiation is proportional to inverse square of a distance. Therefore, the effort to minimize an obstacle of the bladder and the rectum by using the packing should be made.

  • PDF

Surgical Treatment of Anomalous Origin of Coronary Artery from the Pulmonary Artery: Postoperative Changes of Ventricular Dimensions and Mitral Regurgitation (관상동맥-폐동맥 이상기시증(Anomalous Origin of Coronary Artery from Pulmonary Artery)의 수술적 치료: 중기 성적과 좌심실 및 승모판 기능의 변화 양상에 대한 연구)

  • Kang, Chang-Hyun;Kim, Woong-Han;Seo, Hong-Joo;Kim, Jae-Hyun;Lee, Cheul;Chang, Yoon-Hee;Hwang, Seong-Wook;Back, Man-Jong;Oh, Sam-Se;Na, Chan-Young;Han, Jae-Jin;Lee, Young-Tak;Kim, Chong-Whan
    • Journal of Chest Surgery
    • /
    • v.37 no.1
    • /
    • pp.19-26
    • /
    • 2004
  • Background: The aims of this study are to verify the result of the surgical treatment of ALCAPA and to identify the postoperative changes of left ventricular dimensions and mitral regurgitation (MR), Material and Method: Fifteen patients operated on since 1985 were included in the study. The patients operated on before 1998 (n=9) showed heterogeneous properties with various surgical strategies and cardiopulmonary bypass techniques. However, six patients were operated on with the established surgical strategy since 1998; 1) Dual perfusion and dual cardioplegic solution delivery through ascending aorta and main pulmonary artery, 2) Coronary transfer by rolled-conduit made of pulmonary artery wall flap, and 3) Additional mitral valvular procedure was not peformed. Result: Median age of the study group was 6 months (1 month to 34 years). The operative methods were left subclavian artery to left coronary artery anastomosis in 1, simple ligation in 2, Takeuchi operation in 2, and coronary reimplantation in 10 patients. The mean follow up period was 5.5<5.8 years (2 months 14 years), There were one early death (6.7%) and one late death. Overall 5-year survival rate was 85.6$\pm$9.6%. The Z-value of left ventricular end-diastolic and end-systolic dimensions were 6.4$\pm$3.0 and 5.1 $\pm$3.6 preoperatively, and decreased to 1.7$\pm$ 1.9 and 0.8$\pm$ 1.6 in 3 months (p<0.05). Significant preoperative MR was identified in 6 patients (40%) and all the patients showed immediate improvement of MR within f month postoperatively. There were 3 cases of reoperation due to coronary anastomosis site stenosis and recurrence of MR. However, there was no mortality nor late reoperation in the patients operated on after 1998. Conclusion: The surgical treatment of ALCAPA showed favorable survival and early recovery of ventricular dimensions and mitral valvular function. Although long-term reintervention was required in some cases of earlier period, all the cases after 1998 showed excellent surgical outcome without long-term problem.

A Deep Learning Based Approach to Recognizing Accompanying Status of Smartphone Users Using Multimodal Data (스마트폰 다종 데이터를 활용한 딥러닝 기반의 사용자 동행 상태 인식)

  • Kim, Kilho;Choi, Sangwoo;Chae, Moon-jung;Park, Heewoong;Lee, Jaehong;Park, Jonghun
    • Journal of Intelligence and Information Systems
    • /
    • v.25 no.1
    • /
    • pp.163-177
    • /
    • 2019
  • As smartphones are getting widely used, human activity recognition (HAR) tasks for recognizing personal activities of smartphone users with multimodal data have been actively studied recently. The research area is expanding from the recognition of the simple body movement of an individual user to the recognition of low-level behavior and high-level behavior. However, HAR tasks for recognizing interaction behavior with other people, such as whether the user is accompanying or communicating with someone else, have gotten less attention so far. And previous research for recognizing interaction behavior has usually depended on audio, Bluetooth, and Wi-Fi sensors, which are vulnerable to privacy issues and require much time to collect enough data. Whereas physical sensors including accelerometer, magnetic field and gyroscope sensors are less vulnerable to privacy issues and can collect a large amount of data within a short time. In this paper, a method for detecting accompanying status based on deep learning model by only using multimodal physical sensor data, such as an accelerometer, magnetic field and gyroscope, was proposed. The accompanying status was defined as a redefinition of a part of the user interaction behavior, including whether the user is accompanying with an acquaintance at a close distance and the user is actively communicating with the acquaintance. A framework based on convolutional neural networks (CNN) and long short-term memory (LSTM) recurrent networks for classifying accompanying and conversation was proposed. First, a data preprocessing method which consists of time synchronization of multimodal data from different physical sensors, data normalization and sequence data generation was introduced. We applied the nearest interpolation to synchronize the time of collected data from different sensors. Normalization was performed for each x, y, z axis value of the sensor data, and the sequence data was generated according to the sliding window method. Then, the sequence data became the input for CNN, where feature maps representing local dependencies of the original sequence are extracted. The CNN consisted of 3 convolutional layers and did not have a pooling layer to maintain the temporal information of the sequence data. Next, LSTM recurrent networks received the feature maps, learned long-term dependencies from them and extracted features. The LSTM recurrent networks consisted of two layers, each with 128 cells. Finally, the extracted features were used for classification by softmax classifier. The loss function of the model was cross entropy function and the weights of the model were randomly initialized on a normal distribution with an average of 0 and a standard deviation of 0.1. The model was trained using adaptive moment estimation (ADAM) optimization algorithm and the mini batch size was set to 128. We applied dropout to input values of the LSTM recurrent networks to prevent overfitting. The initial learning rate was set to 0.001, and it decreased exponentially by 0.99 at the end of each epoch training. An Android smartphone application was developed and released to collect data. We collected smartphone data for a total of 18 subjects. Using the data, the model classified accompanying and conversation by 98.74% and 98.83% accuracy each. Both the F1 score and accuracy of the model were higher than the F1 score and accuracy of the majority vote classifier, support vector machine, and deep recurrent neural network. In the future research, we will focus on more rigorous multimodal sensor data synchronization methods that minimize the time stamp differences. In addition, we will further study transfer learning method that enables transfer of trained models tailored to the training data to the evaluation data that follows a different distribution. It is expected that a model capable of exhibiting robust recognition performance against changes in data that is not considered in the model learning stage will be obtained.