• Title/Summary/Keyword: Z-axis

Search Result 655, Processing Time 0.037 seconds

Improving the Three-Dimensional Printability of Potato Starch Loaded onto Food Ink

  • Yourim Oh;Seungmin Lee;Nam Keun Lee;Jin-Kyu Rhee
    • Journal of Microbiology and Biotechnology
    • /
    • v.34 no.4
    • /
    • pp.891-901
    • /
    • 2024
  • This study focuses on improving the 3D printability of pea protein with the help of food inks designed for jet-type 3D printers. Initially, the food ink base was formulated using nanocellulose-alginate with a gradient of native potato starch and its 3D printability was evaluated. The 3D-printed structures using only candidates for the food ink base formulated with or without potato starch exhibited dimensional accuracy exceeding 95% on both the X and Y axes. However, the accuracy of stacking on the Z-axis was significantly affected by the ink composition. Food ink with 1% potato starch closely matched the CAD design, with an accuracy of approximately 99% on the Z-axis. Potato starch enhanced the stacking of 3D-printed structures by improving the electrostatic repulsion, viscoelasticity, and thixotropic behavior of the food ink base. The 3D printability of pea protein was evaluated using the selected food ink base, showing a 46% improvement in dimensional accuracy on the Z-axis compared to the control group printed with a food ink base lacking potato starch. These findings suggest that starch can serve as an additive support for high-resolution 3D jet-type printing of food ink material.

Evaluation of Setup When Using C-Rad System in Radiotherapy (방사선치료 시 C-Rad system을 이용한 셋업의 평가)

  • Park, Eun-Tae;Ko, Seong-Jin;Choi, Seok-Yoon;Kim, Jung-Hoon;Kim, Chang-Soo;Kim, Dong-Hyun;Kang, Se-Sik
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.5
    • /
    • pp.303-310
    • /
    • 2012
  • In radiotherapy, accurate patient positioning and set up are important factor that treatment can influence success. In generally, the 3-laser system is used when the patient set up. But today the body surface scanning system(C-Rad system) is trying to use. Compare and evaluate the C-Rad system and the 3-laser system to check availability. Head and neck that are no movement of internal organs and easy to apply fixation device are limited. Alderson Rando anthropomorphic phantom and 10 patients who have lesions of head and neck are targeted. C-RAD system's setup error mean and standard deviation are the X axis($0.55{\pm}0.51mm$), Y axis($-0.2mm{\pm}0.523mm$), Z axis($-0.85{\pm}0.587mm$) in the phantom study, and in the patient study X axis($-0.05{\pm}0.621mm$), Y axis($0.075{\pm}0.755mm$) Z axis($-1.025{\pm}0.617mm$). So C-RAD system is better than 3-laser system mostly, but C-RAD system's error rate is a little worse than 3-laser system in the Z axis. When radiation treatment of head and neck, body surface contour scanning system contribute to correct positioning and minimize the set up error.

EFFECT OF THE SHAPE OF IMPINGEMENT PLATE ON THE VAPORIZATION AND FORMATION OF FUEL MIXTURE IN IMPINGING SPRAY

  • Kang, J.J.;Kim, D.W.;Choi, G.M.;Kim, D.J.
    • International Journal of Automotive Technology
    • /
    • v.7 no.5
    • /
    • pp.585-593
    • /
    • 2006
  • The effect of the shape of the side wall on vaporization and fuel mixture were investigated for the impinging spray of a direct injection(DI) gasoline engine under a variety of conditions using the LIEF technique. The characteristics of the impinging spray were investigated under various configurations of piston cavities. To simulate the effect of piston cavity configurations and injection timing in an actual DI gasoline engine, the parameters were horizontal distance from the spray axis to side wall and vertical distance from nozzle tip to impingement plate. Prior to investigating the side wall effect, experiments on free and impinging sprays for flat plates were conducted and these results were compared with those of the side wall impinging spray. For each condition, the impingement plate was located at three different vertical distances(Z=46.7, 58.4, and 70 mm) below the injector tip and the rectangular side wall was installed at three different radial distances(R=15, 20, and 25 mm) from the spray axis. Radial propagation velocity from spray axis along impinging plate became higher with increasing ambient temperature. When the ambient pressure was increased, propagation speed reduced. High ambient pressures tended to prevent the impinging spray from the propagating radially and kept the fuel concentration higher near the spray axis. Regardless of ambient pressure and temperature fully developed vortices were generated near the side wall with nearly identical distributions, however there were discrepancies in the early development process. A relationship between the impingement distance(Z) and the distance from the side wall to the spray axis(R) was demonstrated in this study when R=20 and 25 mm and Z=46.7 and 58.4 mm. Fuel recirculation was achieved by adequate side wall distance. Fuel mixture stratification, an adequate piston cavity with a shorter impingement distance from the injector tip to the piston head should be required in the central direct injection system.

Kinematic Analysis of T-Stop Motion by Inline Skate Rolling Speed (인라인 스케이트 활주속력에 따른 T-Stop의 운동학적 분석)

  • Han, Je-Hee;Woo, Byung-Hoon;Kim, Jeong-Goo;Kim, Tae-Whan;Kim, Sung-Sup;Kim, Eui-Hwan
    • Korean Journal of Applied Biomechanics
    • /
    • v.20 no.4
    • /
    • pp.355-364
    • /
    • 2010
  • The purpose of this study was to investigate the kinematical analysis of T-stop motion by inline skate rolling speed. Six subjects were participated in the experiment(age: $35.0{\pm}3.3$ yrs, weight: $72.70{\pm}5.1\;kg$, height: $176.30{\pm}3.1\;cm$, career: $10.00{\pm}2.5$ yrs). The study method adopted 3-dimensional analysis and 2 cameras for filming to analyze the required displacement of center of mass, displacement of right and left hip joint, displacement of right and left knee joint, displacement of trunk tilt using by APAS. The results were as follows; In anterior-posterior displacement of COM, the faster rolling speed, the longer displacement at phase 2. In vertical displacement of COM, the faster rolling speed, the lower displacement. In medial-lateral displacement of COM, there was no significant on rolling speed. In angular displacement of right thigh segment, the faster rolling speed, the bigger displacement in X and Z axis. In angular displacement of left thigh segment, the faster rolling speed, the lower displacement in X axis. In angular displacement of right shank segment, the faster rolling speed, the bigger displacement in Z axis. In angular displacement of left shank segment, the faster rolling speed, the bigger displacement in X and Y axis. In angular displacement of trunk segment, the faster rolling speed, the bigger displacement in Z axis.

An Optical Intense 2D Electric Field Sensor Using a Single LiNO3 Crystal

  • Zhang, Yuanying;Zhang, Jiahong;Li, Yingna;Lei, Hongyi
    • Current Optics and Photonics
    • /
    • v.6 no.2
    • /
    • pp.183-190
    • /
    • 2022
  • Based on the linear electro-optic (EO) effect of lithium niobite (LiNbO3, LN) crystal, an intense two-dimensional (2D) electric field sensor was analyzed, fabricated and experimentally demonstrated. The linear polarized light beam transmits along the optical axis (z-axis) of the LN crystal, and the polarization direction of the polarized light is 45° to the y-axis. The sensor can detect the intensity of a 2D electric field that is perpendicular to the z-axis. Experimental results demonstrated that the minimum detectable electric field of the sensor is 10.5 kV/m. The maximum detected electric field of the sensor is larger than 178.9 kV/m. The sensitivity of the sensor is 0.444 mV/(kV·m-1). The variation of the sensitivity is within ±0.16 dB when the sensor is rotated around a z-axis from 0° to 360°. The variation of the sensor output optical power is within ±1.4 dB during temperature change from 19 ℃ to 26 ℃ in a day (from 7:00 AM to 23:00 PM) and temperature change from 0 ℃ to 40 ℃ in a controllable temperature chamber. All theoretical and experimental results revealed that the fabricated sensor provides technology for the direct detection of intense 2D electric fields.

Studies on the growth of organic single crystals of urea and THAMP (Urea와 THAMP 유기 단결정의 육성에 관한 연구)

  • 임창성;황완인;김판채
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.5 no.3
    • /
    • pp.223-232
    • /
    • 1995
  • Abstract Urea($(NH_2)_2CO$) and THAMP (Tris(hydroxymethyl) aminomethane phosphate) are new organic nonlinear optical materials (NLO) for the device application such as the frequency conversion of laser radiation. The single crystals of urea and THAMP have been grown by the falling temperature method and the temperature difference method. The crystal growth parameters were presented associated with the molphology of the grown crystals. Based on the solubility measurements, methanol was a suitable solvent for the growth of urea. The solubilities of urea have a positive temperature coefficient and the heat of solution of urea was estimated to be -2.58 kcal/mol. The grown crystals of urea have the preferential growth habit in the z-axis. Additives such as $NH_4_H_2PO_4$, KCL, $H_3PO_4$, $CaCl_2{\cdot}2H_2O$, $C_2H_5OH$ were used for the favourable growth in the x - and y-axis and the preventive growth in the z-axis. The moleratio of THAM and H3P04 for the solution of THAMP was 1 : 1. The solubilities of THAMP have a positive temperature coefficient. The heat of solution was estimated to be - 1.70 kcal/ mol.

  • PDF

Verification of Tool Collision for 3-Axis Milling (3축 밀링 가공의 공구 충돌 검증)

  • Chung, Yun-C.;Park, Jung-W.
    • Proceedings of the KSME Conference
    • /
    • 2001.06c
    • /
    • pp.116-121
    • /
    • 2001
  • Verification of tool collision is an important issue in die and mold machining. In this paper three functions of verification are schematically explained based on Z-Map model. The first function is getting a collision-free region when a tool assembly and a part surface model are given. The second function estimates the shortest length of cutter shank with that the tool cuts all of a region without collision. The last one is cutting simulation considering all parts of tool assembly as well as cutter blade. Those functions can be easily implemented by using several basic operators of Z-Map model which are explained also. Proposed approaches have enough accuracy to verify collision in reasonable computing time.

  • PDF

The error analysis of field size variation in pelvis region by using immobilization device (고정기구의 사용이 골반부위 방사선조사영역의 변화에 미치는 오차분석)

  • Kim, Ki-Hwan;Kang, No-Hyun;Bim, Dong-Wuk;Kim, Jun-Sang;Jang, Ji-Young;Kim, Yong-Eun;Kim, Jae-Sung;Cho, Moon-June
    • Journal of Radiation Protection and Research
    • /
    • v.25 no.1
    • /
    • pp.31-36
    • /
    • 2000
  • In radiotherapy, it may happen to radiate surrounding normal tissue because of inconsistent field size by changing patient position during treatment. We are going to analyze errors reduced by using immobilization device with Electonic portal imaging device(EPID) in this study. We had treated the twenty-one patients in pelvic region with 10 MV X-ray from Aug. 1998 to Aug. 1999 at Chungnam National University Hospital. All patients were treated at supine position during treatment. They were separated to two groups, 11 patients without device and 10 patients with immobilization device. We used styrofoam for immobilization device and measured the errors of anterior direction for x, y axis and lateral direction for z, y axis from simulation film to EPID image using matching technique. For no immobilization device group, the mean deviation values of x axis and y axis are 0.19 mm. 0.48 mm, respectively and the standard deviations of systematic deviation are 2.38 mm, 2.19 mm, respectively and of random deviation for x axis and y axis are 1.92 mm. 1.29 mm, respectively. The mean deviation values of z axis and y axis are -3.61 mm. 2.07 mm, respectively and the standard deviations of systematic deviation are 3.20 mm, 2.29 mm, respectively and of random deviation for z axis and y axis are 2.73 mm. 1.62 mm, respectively. For immobilization device group, the mean deviation values of x axis and y axis are 0.71 mm. -1.07 mm, respectively and the standard deviations of systematic deviation are 1.80 mm, 2.26 mm, respectively and of random deviation for x axis and y axis are 1.56 mm. 1.27 mm, respectively. The mean deviation values of z axis and y axis are -1.76 mm. 1.08 mm, respectively and the standard deviations of systematic deviation are 1.87 mm, 2.83 mm, respectively and of random deviation for x axis and y axis are 1.68 mm, 1.65 mm, respectively. Because of reducing random and systematic error using immobilization device, we had obtained good reproducibility of patient setup during treatment so that we recommend the use of immobilization device in pelvic region of radiation treatment.

  • PDF

Cutting force prediction in the ball-end milling process of barious cutting area using Z-map (Z map을 이용한 임의의 절삭영역에서 볼엔드밀의 절삭력예측)

  • 김규만;조필주;김병희;주종남
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.14 no.3
    • /
    • pp.57-65
    • /
    • 1997
  • In this study, a cutting force in the Ball-end milling process is calculated using Z-map. Z-map can describe any type of cutting area resulting from the previous cutting geometry and cutting condition. Cutting edge of a ball-end mill is divided into infinitesimal cutting edge elements and the position of the ele- ment is projected to the cutter plane normal to the Z axis. Also the cutting area in the cutter plane is obtained by using the Z-map. Comparing this projected position with cutting area, it can be determined whether it engages in the cutting. The cutting force can be calculated by numerical integration of cutting force acting on the engaged cutting edge elements. A series of experiments such as contouring and upward/downward ramp cutting was performed to verify the calculated cutting force.

  • PDF

A survey and research of a noise & a vibration level of bridges on the Han river (한강상 교량의 소음.진동레벨 조사.연구)

  • Seo, Kwang-Suk;Lee, Yoen-Soo;Park, Young-Man;Lee, Sang-Soo;Jeon, Jae-Sik
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.278-280
    • /
    • 2007
  • This survey was carried out to provide a sound and a vibration level of bridges on the Han river. A sound and a vibration level of 6 bridges(Ban po, Cheon ho, Olympic, Jam soo, Young dong, Dong ho) were measured. The X-axis vibration level($L_{10}$) was $42{\sim}60$ dB(H), Y-axis vibration level was $41{\sim}52$ dB(H) and Z-axis vibration level was $44{\sim}77$ dB(V). The Z-axis vibration level($L_{10}$) on the midpoint of bridges was 68 dB(V), and on the joint point was 56 dB(V). The sound level was $77{\sim}84$ dB(A). The sound level of Jam soo bridge was higher than any other bridges.

  • PDF