• Title/Summary/Keyword: Z-변환

Search Result 196, Processing Time 0.021 seconds

A 3D Terrain Reconstruction System using Navigation Information and Realtime-Updated Terrain Data (항법정보와 실시간 업데이트 지형 데이터를 사용한 3D 지형 재구축 시스템)

  • Baek, In-Sun;Um, Ky-Hyun;Cho, Kyung-Eun
    • Journal of Korea Game Society
    • /
    • v.10 no.6
    • /
    • pp.157-168
    • /
    • 2010
  • A terrain is an essential element for constructing a virtual world in which game characters and objects make various interactions with one another. Creating a terrain requires a great deal of time and repetitive editing processes. This paper presents a 3D terrain reconstruction system to create 3D terrain in virtual space based on real terrain data. In this system, it converts the coordinate system of the height maps which are generated from a stereo camera and a laser scanner from global GPS into 3D world using the x and z axis vectors of the global GPS coordinate system. It calculates the movement vectors and the rotation matrices frame by frame. Terrain meshes are dynamically generated and rendered in the virtual areas which are represented in an undirected graph. The rendering meshes are exactly created and updated by correcting terrain data errors. In our experiments, the FPS of the system was regularly checked until the terrain was reconstructed by our system, and the visualization quality of the terrain was reviewed. As a result, our system shows that it has 3 times higher FPS than other terrain management systems with Quadtree for small area, improves 40% than others for large area. The visualization of terrain data maintains the same shape as the contour of real terrain. This system could be used for the terrain system of realtime 3D games to generate terrain on real time, and for the terrain design work of CG Movies.

Surface Elevation Recovery Methods from Pressure Gage for Irregular Waves (불규칙파(不規則波에) 대한 압력식(壓力式) 파고계(波高計)의 적용성(適用性)에 관한 연구(研究))

  • Kwon, Jung Gon;Kang, Ju Bok
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.12 no.4_1
    • /
    • pp.129-136
    • /
    • 1992
  • A precedure for recovering surface displacement from a time series of pressure measured by a pressure gage in a shallow water (that is, FFTM, LCM. IWM) is investigated with respect to a proper cut-off-frequency of a frequency response function for the accurate recovery of wave height and period. The authors examined the applicability of above mentioned three transformation procedures through field observations and laboratory experiments and the following results are obtained. i) The cut-off-frequency of the frequency response function used in FFTM is deeply depend on both the frequency response of the pressure sensor and the water depth at the sensor. In this study, a relatively accurate surface displacement can be recovered when the frequency response function is cut off at the frequency corresponding to kh=3.0 where k is a wave number at the depth of h. The frequency response function in the region higher than the cut-off-frequency is set constant to be the value at the cut-off-frequency. ii) The transformed surface displacements by LCM are affected by the small waves of short periods included in the measured pressure. It is found that pressure variation whose local frequency is higher than kh=1.5 has to be neglected to recover surface displacement sufficiently. iii) In IWM, the linear pressure response function is usually utilized by multiplying a coefficient N which is a function of the frequency (or kh) and takes a value around unity. However, in this study, a constant value of N(=1.0) gives a relatively accurate recovery of surface displacements.

  • PDF

THE COMPARISON OF POLYMERIZATION OF COMPOSITE RESIN INFLUENCED BY CURING DEPTH AND SHADE (광중합 복합레진의 색상과 깊이에 따른 중합도의 비교)

  • Choi, Kung-Ho;Lee, Ju-Hyun;Park, Ho-Won
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.2
    • /
    • pp.280-289
    • /
    • 2004
  • Adequate polymerization is a crucial factor in obtaining optimal physical properties and clinical performance of resin composite restorative materials. The purpose of this study was to determine the effectiveness of shade and depth on dental composite resin polymerized with plasma arc curing unit employing FTIR and microhardness. From this experiment, the following results were obtained : 1. The light transmission and microhardness by mode 6 in plasma arc curing were similar to by 20 secs in halogen light curing. 2. The experimental groups of A1, A2, A3, A3.5 were not signifcant difference to light transmission and microhardness on surface and 2mm depth, but were significant difference on 3mm and 4mm depth. Especially light transmission and microhardness were small in darker shade and deeper thickness. 3. Compared with depth cure, uncured monomer amount increased at more than 2mm depth. 4. The light transmission by FTIR and polymerization by microhardness were significant corelation.

  • PDF

Development of Target-Controlled Infusion System in Plasma Concentration. PART1 : Establishment of Pharmacokinetic Model and Verification (혈중 목표 농도 자동 조절기(TCI) 개발 PART1 : 약동학적 모델의 수립과 검증)

  • 안재목;길호영
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.5
    • /
    • pp.341-349
    • /
    • 2002
  • The target controlled infusion(TCI) pump system is a logical approach to the development of improved administration techniques of an intravenous anaesthetic agent. The principle of TCI system is based on an understanding of the pharmacokinetic properties, three or four compartment model. The TCI system is optimal and flexible control of the plasma drug concentration. But the clinical goal is always to achieve a therapeutic drug effect, not a therapeutic concentration. So we developed the algorithm to target the concentration at the site of drug effect rather than the concentration in the plasma. If impulse drug is inputted into body, the decline of plasma concentration with time is shown, resulting in the expression of the differential equation. Therefore, we must reformulate our three-compartment model as four-compartment model with the effect compartment. And we tested plasma targeting and effect targeting algorithm by computer simulation using four-compartment model. So we developed the TCI capable of applying all intravenous drugs by adjusting individual pharmacokinetic parameters independently.

Development of the Robot Manipulator for Kinematies (기구학적 분석을 이용한 로봇 매니퓰레이터 개발)

  • Min, Byeong-Ro;Lee, Dae-Weon
    • Journal of Bio-Environment Control
    • /
    • v.13 no.1
    • /
    • pp.1-7
    • /
    • 2004
  • This study is kinematics for the manipulator development of cucumber harvesting. A theory value was verified by repeated error measurement after the forward kinematics or inverse kinematics analysis of manipulator. Manipulator is consisted of one perpendicular link and two revolution link. The transformation of manipulator can be valued by kinematics using Denavit-Hartenberg parameter. The value of inverse kinematics which is solved by three angles faction shows two types. Repeated errors refered maximum 2.60 mm, 2.05mm and 1.55 mm according to X, Y, Z axis. In this study, the actual coordinates of maximum point and minimum point were agreement in the forward kinematics or inverse kinematics. The results of repeated error measurement were reflect to be smaller compared to a diameter of cucumber. measurement errors were determined by experimented errors during the test. For reducing errors of manipulator and improving work efficiency, the number of link should be reduced and breeding and cultural environment should be considered to reduce the weight and use the hard stuff. The velocity of motor for working should be considered, too.

Evaluation of Structural Robustness of External Fuel Tank and Pylon for Military Aircraft under Random Vibration (랜덤진동에서 군용 항공기 외부연료탱크 및 파일런 구조 강건성 평가)

  • Kim, Hyun-Gi;Kim, Sungchan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.3
    • /
    • pp.777-783
    • /
    • 2021
  • Aircraft are affected by various vibrations during maneuvering. These vibrations may have a fatal effect on the survival of aircraft in some cases, so the safety of components applied to the aircraft should be proven against various vibrations through random vibration analysis. In this study, the structural robustness of an external fuel tank and pylon for military aircraft was evaluated under random vibration conditions using commercial software, MSC Random. In the random vibration analysis, a frequency response analysis was performed by imposing a unit load on the boundary condition point, and then excitation was performed with a PSD profile. In this process, the required mode data was extracted through a modal analysis method. In addition, the random vibration profile specified in the US Defense Environment Standard was applied as random vibration conditions, and the PSD profile given in units of G's was converted into units of gravitational acceleration. As a result of the numerical analysis, we evaluated the structural robustness of the external fuel tank and pylon by identifying the safety margins of beam elements, shell elements, and solid elements in a numerical model for random vibration in the x, y, and z directions.

A channel parameter-based weighting method for performance improvement of underwater acoustic communication system using single vector sensor (단일 벡터센서의 수중음향 통신 시스템 성능 향상을 위한 채널 파라미터 기반 가중 방법)

  • Kang-Hoon, Choi;Jee Woong, Choi
    • The Journal of the Acoustical Society of Korea
    • /
    • v.41 no.6
    • /
    • pp.610-620
    • /
    • 2022
  • An acoustic vector sensor can simultaneously receive vector quantities, such as particle velocity and acceleration, as well as acoustic pressure at one location, and thus it can be used as a single input multiple output receiver in underwater acoustic communication systems. On the other hand, vector signals received by a single vector sensor have different channel characteristics due to the azimuth angle between the source and receiver and the difference in propagation angle of multipath in each component, producing different communication performances. In this paper, we propose a channel parameter-based weighting method to improve the performance of an acoustic communication system using a single vector sensor. To verify the proposed method, we used communication data collected from the experiment conducted during the KOREX-17 (Korea Reverberation Experiment). For communication demodulation, block-based time reversal technique which is robust against time-varying channels were utilized. Finally, the communication results showed that the effectiveness of the channel parameter-based weighting method for the underwater communication system using a single vector sensor was verified.

Research on Local and Global Infrared Image Pre-Processing Methods for Deep Learning Based Guided Weapon Target Detection

  • Jae-Yong Baek;Dae-Hyeon Park;Hyuk-Jin Shin;Yong-Sang Yoo;Deok-Woong Kim;Du-Hwan Hur;SeungHwan Bae;Jun-Ho Cheon;Seung-Hwan Bae
    • Journal of the Korea Society of Computer and Information
    • /
    • v.29 no.7
    • /
    • pp.41-51
    • /
    • 2024
  • In this paper, we explore the enhancement of target detection accuracy in the guided weapon using deep learning object detection on infrared (IR) images. Due to the characteristics of IR images being influenced by factors such as time and temperature, it's crucial to ensure a consistent representation of object features in various environments when training the model. A simple way to address this is by emphasizing the features of target objects and reducing noise within the infrared images through appropriate pre-processing techniques. However, in previous studies, there has not been sufficient discussion on pre-processing methods in learning deep learning models based on infrared images. In this paper, we aim to investigate the impact of image pre-processing techniques on infrared image-based training for object detection. To achieve this, we analyze the pre-processing results on infrared images that utilized global or local information from the video and the image. In addition, in order to confirm the impact of images converted by each pre-processing technique on object detector training, we learn the YOLOX target detector for images processed by various pre-processing methods and analyze them. In particular, the results of the experiments using the CLAHE (Contrast Limited Adaptive Histogram Equalization) shows the highest detection accuracy with a mean average precision (mAP) of 81.9%.

Synthesis of ${\alpha}$-Alumina Nanoparticles Through Partial Hydrolysis of Aluminum Chloride Vapor (염화알미늄 증기의 부분가수분해를 통한 알파 알루미나 나노입자 제조)

  • Park, Hoey Kyung;Yoo, Youn Sug;Park, Kyun Young;Jung, Kyeong Youl
    • Korean Chemical Engineering Research
    • /
    • v.49 no.5
    • /
    • pp.664-668
    • /
    • 2011
  • Spherical alumina precursors represented by $AlO_xCl_y(OH)_z$, 30~200 nm in particle diameter, were prepared by partial hydrolysis of $AlCl_3$ vapor in a 500 ml reactor. Investigated on the particle morphology and size were the effects of the reaction time, the stirring speed and the reaction temperature. The particle morphology and size was insensitive to the reaction time in the range 20 to 300 s. The variation of the stirring speed from 0 to 300 and 800 rpm showed that the particle size was the largest at 0 rpm. As the temperature was varied from 180 to 190, 200, $140^{\circ}C$, the particle size showed a maximum at $190^{\circ}C$. By calcination of the as-produced particles at $1,200^{\circ}C$ for 6h with a heating rate of $10^{\circ}C$/min, ${\alpha}$-alumina particles 45 nm in surface area equivalent diameter were obtained. The particle shape after calcination turned wormlike due to sintering between neighboring particles. A rapid calcination at $1400^{\circ}C$ for 0.5 h with a higher heating rate of $50^{\circ}C$/min reduced the sintering considerably. An addition of $SiCl_4$ or TMCTS(2,4,6,8-tetramethylcyclosiloxane) to the $AlCl_3$ reduced the sintering effectively in the calcination step; however, peaks of ${\gamma}$ or mullite phase appeared. An addition of $AlF_3$ to the particles obtained from the hydrolysis resulted in a hexagonal disc shaped alumina particles.

Evaluation of difference in respiratory phase between amplitude- and phase-based four-dimensional computed tomography (위상 기반 사차원전산화단층촬영과 진폭 기반 사차원전산화단층촬영 영상에서의 위상차 평가)

  • Lee, So Hyang;Park, Soo Yeon;Kim, Jong Sik;Choi, Byung Ki;Park, Hee Chul;Jung, Sang Hoon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.1
    • /
    • pp.73-78
    • /
    • 2015
  • Purpose : Under the assumption of change to the amplitude based sorting, the study will use four dimensional computed tomography imaging (4DCT) arrayed using the phase based sorting to analyze the respiratory phase difference. Materials and Methods : The study analyzed the 4DCT (4-dimensional computed tomography) images of 10 liver cancer patients that were treated with respiratory gated radiotherapy from 2015 February to March. Using RPM respiratory gating (RPM 1.7.5, Varian, USA) equipment, imaging according to respiratory cycle of phase based sorting was acquired and using a treatment planning system (Pinnacle 9.2, Philips, USA) the acquired imaging according to respiratory cycle was used to measure the abdominal movement value by respiratory cycle. The measuring point was the point where the center point of the Marker Block and the body surface met in the 50% phase image and here the coordinate values Lateral, Vertical, Longitudinal (X, Y, Z) were set as reference points, and on the X, Z plane identical to the reference point, using the identical method the Y axis coordinate value of each 0%, 30%, 40%, 50%, 60%, 80% phase images were acquired to quantitatively measure the variation of distance to the Y axis. The abdominal movement value according to respiration was applied to the theoretical model that the value decreases linearly from maximum inhalation to maximum exhalation to divide the variation of my value to predict as amplitude value by respiratory cycle and conversely the variation in amplitude was recalculated with the phase variation deviation value to analyze. Results : The deviation value between expected value and actual location was the largest in the 30% phase with 0.24 cm, and standard deviation was also the largest in 30% phase with 0.13 cm. The effective value of the deviation value derived from the average of the deviation squared value of each patient appeared as minimum 0.7 cm, maximum 0.18 cm, average 0.12 cm, and standard deviation 0.4 cm. Also by dividing the actual movement distance value with the peak expiration value then converting it into %Phase, the deviation value with actual phase 16.5% in 30% phase, 10.0% and 40% phase, 10.0% and 60% phase, 15.4% and 80% phase, and overall average about 13%, and arraying based on amplitude, phase shift occurred and further it was from peak expiration the chance of deviation occurrence was increasingly measured. Conclusion : Based on the results of the study there were differences between value acquired based on theoretical model and actual value. Therefore in respiratory gated radiotherapy using external surrogates, there needs to be establishment of respiration gated radiation system that avoids the combination of two Sorting methods considering that there will be occurrence of treatment and corresponding clinical differences due to the phase difference that occur due to the Amplitude based Phase Sorting.

  • PDF