• Title/Summary/Keyword: Young blood

Search Result 5,654, Processing Time 0.034 seconds

Dietary zinc intake is inversely associated with systolic blood pressure in young obese women

  • Kim, Jihye
    • Nutrition Research and Practice
    • /
    • v.7 no.5
    • /
    • pp.380-384
    • /
    • 2013
  • Zinc may participate in blood pressure regulation and in the pathogenesis of hypertension. The study examined the relationship between zinc status and blood pressure in obese Korean women. Forty obese women (body mass index (BMI) ${\geq}25kg/m^2$) aged 19-28 years participated in this study. Zinc intake was estimated from one 24 hour recall and 2-day diet records. Serum and urinary zinc concentrations were determined by atomic absorbance spectrophotometry. Systolic blood pressure (SBP) and diastolic blood pressure (DBP) were measured using an automatic sphygmometer. Metabolic variables, such as waist circumference, triglyceride, high density lipoprotein (HDL) cholesterol, fasting glucose, and fasting insulin, were also measured. Dietary zinc intake of obese women was averagely 7.5 mg/day. Serum zinc and urinary zinc concentrations were $13.4{\mu}mol/L$ and $378.7{\mu}g/day$, respectively. Averages of SBP and DBP were 119 mmHg and 78 mmHg. Dietary zinc intake was negatively correlated with SBP after adjusting for energy intake (P < 0.05), but serum and urinary zinc concentrations were not found to be correlated with SBP or DBP. Multivariate linear regression analysis showed that dietary zinc intake was inversely associated with SBP in obese women after adjusting for body weight, energy intake and sodium intake (P = 0.0145). The results show that dietary zinc intake may be an independent risk factor of elevated SBP in obese Korean women.

Studies on Changes of Blood Components and Body Composition in the Cadets (사관생도들의 혈액성분 및 신체조성 변화 연구)

  • Kim, Dong-Soo;Chung, Yeon-Soo;Kim, Keun-Su
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.14 no.1
    • /
    • pp.139-146
    • /
    • 2011
  • This study investigated physical and physiological changes of normal young adults, who are cadets of the Air Force Academy, have kept long-term physical activities and healthy behavior. The physical and physiological indices were the blood and body composition. Data were collected at the first year period, and then 4th year period from same group of cadets. The amounts of blood components were not changed, but variation among cadets was significantly reduced in the 4th grade period. The red blood cells(RBCs) were significantly reduced and the concentration of hemoglobin(HGB) were significantly increased. The body weight was significantly decreased in the 1st grade period since the body fat was rapidly decreased after the basic military drill, and then it was recovered with building up of the skeletal muscle in the 4th grade period. Asymmetry of the arms was decreased with the increased physical activities and usage of various equipments. The muscular endurance were significantly enhanced in the 4th grade period. The long-term physical activities and healthy behaviors may keep the physical strength through enhanced blood stream and oxygen supply by reduction of the RBCs and increased HGB concentration, and fat and muscle control.

Development of Reliability Demonstration Test for Personal Blood Glucose Meters (개인용 혈당측정기의 신뢰성 보증시험 개발)

  • Kim, Gi-Young;Park, Ho-Joon;Park, Chan-Soo;Ham, Jung-Keol;Jang, Joong Soon
    • Journal of Applied Reliability
    • /
    • v.13 no.4
    • /
    • pp.299-307
    • /
    • 2013
  • The value of blood sugar is measured by a personal blood glucose meter which consists of two parts: a glucose strip and a blood glucose meter. A personal blood glucose meter makes use of electric media which are composed of glucose oxidase and electron. This study is to propose a method of reliability demonstration test derived from field data analysis and FMEA(Failure Mode and Effect Analysis). Detailed Conditions for reliability demonstration test are selected from the comparison of various failure mechanisms. The most dominant failure mechanism is wear-out which is caused by strip insertion/extraction. The testing device that can reproduce the failure mechanism of strip insertion/extraction is made to conduct reliability demonstration test. Using the testing device, it is confirmed that target lifetime of selected devices is more than 2 years.

A Structural Analysis on the Leaflet Motion Induced by the Blood Flow for Design of a Bileaflet Mechanical Heart Valve Prosthesis

  • Kwon, Young-Joo;Kim, Chang-Nyung;Lee, Jae-Won
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.9
    • /
    • pp.1316-1323
    • /
    • 2003
  • This paper presents a structural analysis on the rigid and deformed motion of the leaflet induced by the blood flow required in the design of a bileaflet mechanical heart valve (MHV) prosthesis. In the study on the design and the mechanical characteristics of a bileaflet mechanical heart valve, the fluid mechanics analysis on the blood flow passing through leaflets, the kinetodynamics analysis on the rigid body motion of the leaflet induced by the pulsatile blood flow, and the structural mechanics analysis on the deformed motion of the leaflet are required sequentially and simultaneously. Fluid forces computed in the previous hemodynamics analysis on the blood flow are used in the kinetodynamics analysis on the rigid body motion of the leaflet. Thereafter, the structural mechanics analysis on the deformed motion of the leaflet follows to predict the structural strength variation of the leaflet as the leaflet thickness changes. Analysis results show that structural deformations and stresses increase as the fluid pressure increases and the leaflet thickness decreases. Analysis results also show that the leaflet becomes structurally weaker and weaker as the leaflet thickness becomes smaller than 0.6 mm.

Experimental Study of Samul-tang Extract and Bambusae caulis in liquamen on the Regional Cerebral Blood Flow and Mean Arterial Blood Pressure in Normal Rats (사물탕합죽력(四物湯合竹瀝)이 국소 뇌혈류량과 평균 혈압에 미치는 실험적 연구)

  • Cho, Young-Lim;Jeong, Hyun-Woo
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.21 no.6
    • /
    • pp.1394-1400
    • /
    • 2007
  • This study was designed to investigate the effects of Samul-tang Extract and Bambusae caulis in liquamen(SEB) on the changes in regional cerebral blood flow (rCBF) and mean arterial blood pressure (MABP) in normal rats. The results were as follows ; SBE significantly increased rCBF in a dose-dependent manner, and increased MABP in a dose-dependent manner. This result suggests that SBE significantly increased rCBF by dilating pial arterial diameter. Increase of SBE-induced rCBF was significantly inhibited by pretreatment with indomethacin (1 mg/kg, i.p.), an inhibitor of cyclooxygenase and increase of SBE-induced rCBF was inhibited by pretreatment with methylene blue ($10\;{\mu}g/kg$, i.p.), an inhibitor of guanylate cyclase. Increase of SBE-induced MABP was significantly increased by pretreatment with methylene blue but increase of SBE-induced MABP was decreased by pretreatment with indomethacin. These results suggested that the action of SBE was mediated by cyclooxygenase.

The Development of a Cuff for the Accuracy Enhancement of the Sphygmomanometer

  • Kim, Won-Ki;Shin, Ki-Young;Mun, Joung-Hwan
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.7 no.2
    • /
    • pp.30-35
    • /
    • 2006
  • The purpose of this study is to develop a new cuff to improve the accuracy of blood pressure measurement, and to evaluate the performance of the developed system. We added a small bladder to the normal cuff, which we refer to as the double bladder system. The system that we developed for blood pressure measurement was based on the oscillometric method using a double bladder. This system was developed in order to reduce the oscillation noise and to amplify the signal of pure blood pressure. An oscillometric signal database based on the developed system was evaluated according to the ANSI/AAMI/SP10-1992 standard. The correlation coefficients between the cuff of the double bladder and the normal cuff were 0.98 for systolic pressure and 0.94 for diastolic pressure. The mean differences and the standard deviations between the average blood pressure obtained from a mercury manometer and that obtained from an automated sphygmomanometer were -0.7mmHg and 4.9mmHg for systolic, and -1.4mmHg and 5.4mmHg for diastolic pressure. We conclude that the proposed double bladder-based cuff system improves the accuracy of oscillometric blood pressure measurement. The developed system reduces the range of error by about $44{\sim}62%$ for systolic pressure and about $6{\sim}21%$ for diastolic pressure compared to the most recently developed, commercially available sphygmomanometers.

Blood Pressure Simulation using an Arterial Pressure-volume Model

  • Yoon, Sang-Hwa;Kim, Jae-Hyung;Ye, Soo-Young;Kim, Cheol-Han;Jeon, Gye-Rok
    • Transactions on Electrical and Electronic Materials
    • /
    • v.9 no.1
    • /
    • pp.38-43
    • /
    • 2008
  • Using an arterial pressure-volume (APV) model, we performed an analysis of the conventional blood pressure estimation method using an oscillometric sphygmomanometer with computer simulation. Traditionally, the maximum amplitude algorithm (MAA) has been applied to the oscillation waveforms of the APV model to obtain the mean arterial pressure and the characteristic ratio. The estimation of mean arterial pressure and characteristic ratio was significantly affected by the shape of the blood pressure waveforms and the cutoff frequency of high-pass filter (HPF) circuitry. Experimental errors result from these effects when estimating blood pressure. To determine an algorithm independent of the influence of waveform shapes and parameters of HPF, the volume oscillation of the APV model and the phase shift of the oscillation with fast Fourier transform (FFT) were tested while increasing the cuff pressure from 1 mmHg to 200 mmHg (1 mmHg/s). The phase shift between ranges of volume oscillation was then only observed between the systolic and the diastolic blood pressures. The same results were obtained from simulations performed on two different arterial blood pressure waveforms and one hyperthermia waveform.

A Study of Relation Between Symptoms and Low Blood Pressure (저혈압의 관련 증상에 관한 연구)

  • Kim, Soo-Young;Jung, Seung-Pil
    • Journal of Yeungnam Medical Science
    • /
    • v.11 no.1
    • /
    • pp.94-100
    • /
    • 1994
  • To establish whether an association exists between low blood pressure and common symptoms such as fatigue, dizziness, headache, and palpitation, we analysed the data of health center in Yeungnam medical college from January 1993 to June 1993. Total 1,133 subjects were taken and results were analysed by combined stratification and logistic regression. The results were as followed : 1. True confounders were sex, age, and body mass index. 2. No association was found between low blood pressure and all symptoms. 3. Positive associations were found between high blood pressure and self reported palpitation and headache, which persisted after adjusted for confounders. The results suggest that low blood pressure and all neurasthenic symptoms such as fatigue, palpitation, headache and dizziness have no association, but the validity is limited.

  • PDF

The Effect of Stair Exercise with Restriction Blood Flow on Knee Extensor Muscle (하지혈류제한과 병행한 계단운동이 무릎 폄근에 미치는 영향)

  • Jun, Je-Yoon;Park, Min-Chull
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.10 no.4
    • /
    • pp.9-14
    • /
    • 2015
  • PURPOSE: Low-intensity exercise with restriction of blood flow has been proposed as an alternative exercise to secure the disadvantage of a high-intensity resistance exercise. However, studies of how affects the muscle using functional exercise are lacking. Thus, the purpose of this study was to investigate knee extensor muscle strength during stair exercise of functional exercise with leg blood flow restriction. METHODS: Twenty two healthy young adults with no history of musculoskeletal or neurogical disorder were participated in this study. participant were randomized into either non-restriction group(11 subject) or restriction group (11 subject). The restriction blood cuff attached to the proximal end of the leg. Measurement of knee extensor strength was used by cybex dynamometer. Data analyzed in independent t-test and paired t-test. RESULTS: Knee extensor muscle strength was significantly different between groups. Also, there were significant differences in the strength of knee extensor within the group. CONCLUSION: This study found that stair exercise with restriction of blood flow did influence to knee extensor muscle strength. These results will also be able to promote the effect of increasing the muscle power applied to functional exercise. Henceforth, studies will be made in the intervention method that can be applied to health vulnerable person.

Portal blood flow measurement by doppler ultrasonography in dogs (도플러 초음파를 이용한 개의 간혈액량의 측정)

  • Sung, Jai-ki;Lee, Young-won;Lee, Hee-chon;An, Yong-ju;Choi, Ho-jung;Yoon, Jung-hee
    • Korean Journal of Veterinary Research
    • /
    • v.37 no.3
    • /
    • pp.661-668
    • /
    • 1997
  • Portal blood flow was measured with pulsed doppler ultrasound in thirty normal dogs. In normal dogs, the average portal blood flow velocity was $17.03{\pm}1.75cm/sec$ and the average portal blood flow was $41.59{\pm}10.10ml/min/kg$. The incident angle between the doppler beam and the portal vein averaged $65^{\circ}$. The average portal vein sectional area was $0.41{\pm}0.14cm^2$. The Congestion index was $0.0245{\pm}0.0081cm{\cdot}sec$. Conclusively, the spectral doppler ultrasonography was quick, non-invasive and simple diagnostic method in circulatory disorders of liver.

  • PDF