• Title/Summary/Keyword: Young Architecture

Search Result 4,246, Processing Time 0.033 seconds

Current State and Improvement of Safety Regulations of Working Platform and Working Passage in Construction Sites (건설현장 작업발판 및 가설통로의 안전기준 현황 및 개선점)

  • Jang, Jun Young;Ahn, Hongseob;Oh, Inhwan;Kim, Tae Wan
    • Journal of the Korea Institute of Construction Safety
    • /
    • v.2 no.1
    • /
    • pp.28-35
    • /
    • 2019
  • The average number of deaths in the construction industry reaches 500 per year, and in particular, it is confirmed that the type of accidents and deaths caused by disasters such as work platforms has occupied more than 60% of the total. In this study, we presented a structured and combined solution for technology, management, education, and cost that can solve systematically, politically, and external environmental factors as well as direct influence factors. In addition, we examined the safety and safety standards of domestic and international safety, and discussed implications. First, direct impact factors, organizational impact factors, policy influence factors, and external environmental impact factors were examined and classified into technical, education, and institutional dimensions. Second, in relation to the installation of the work scaffold, the standards (OSHA 1926.452), UK (The Work at Height Regulations 2005 No.735, BS5975), Japan (Labor Safety and Sanitation Regulations) and Germany (DIN 4420_4, DIN EN12810). In the case of domestic safety standards, similar to the foreign safety standards, safety measures such as materials and specifications are applied. However, details related to the installation, assembly and structure of the work platform are somewhat different from those in the United States and the United Kingdom excluding Japan. Using the results of this study, it is possible to understand the cause of the accident of foot pedestrian accident more systematically and comprehensively, and safety managers and researchers are expected to help in the accident investigation.

Connectivity Assessment Based on Circuit Theory for Suggestion of Ecological Corridor (생태축 제안을 위한 회로 이론 기초 연결성 평가)

  • Yoon, Eun-Joo;Kim, Eun-Young;Kim, Ji-Yeon;Lee, Dong Kun
    • Journal of Environmental Impact Assessment
    • /
    • v.28 no.3
    • /
    • pp.275-286
    • /
    • 2019
  • In order to prevent local extinction of organisms and to preserve biodiversity, it is important to ensure connectivity between habitats. Even if the habitat is exposed to various disturbance factors, it is possible to avoid or respond to disturbances if they are linked to other habitats. Habitat connectivity can be assessed from a variety of perspectives, but the importance of functional connectivity based on species movement has been emphasized in recent years due to the development of computational capabilities and related software. Among them, Circuitscape, which is a connectivity evaluation tool, has an advantage it can provide detailed reference data for the city planning because it maps ecological flows on individual grid based on circuit theory. Therefore, in this study, the functional connectivity of Suwon was evaluated by applying Circuitscape and then, the ecological corridor to be conserved and supplemented was suggested based on it. The results of this study are expected to effectively complement the methodology related ecological corridor/axis, which was previously provided only in the form of a diagram, and to be effective in management of development project and urban planning.

A Nonparametric Long-Term Trend Analysis Using Water Quality Monitoring Data in Nam-River (남강 수질측정망 자료를 이용한 비모수적 장기 수질 추세 분석)

  • Jung, Kang-Young;Kim, Myojeong;Song, Kwang Duck;Seo, Kwon Ok;Hong, Seong Jo;Cho, Sohyun;Lee, Yeong Jae;Kim, Kyunghyun
    • Journal of Environmental Science International
    • /
    • v.27 no.11
    • /
    • pp.1029-1048
    • /
    • 2018
  • In this study, seasonal Mann - Kendall test method was applied to 12 stations of the water quality measurement network of Nam-River based on data of BOD, COD, TN and TP for 11 years from January 2005 to December 2015 The changes of water quality at each station were examined through linear trends and the tendency of water quality change during the study period was analyzed by applying the locally weighted scatter plot smoother (LOWESS) method. In addition, spatial trends of the whole Nam-River were examined by items. The flow-adjusted seasonal Kendall test was performed to remove the flow at the water quality measurement station. As a result, BOD, COD concentration showed "no trand" and TN and TP concentration showed "down trand" in regional Kendall test throughout the study period. BOD and TP concentration in "no trand", COD, and TN concentration showed an "up trand" tendency in Nam-River dam. LOWESS analysis showed no significant water quality change in most of the analysis items and stations, but water quality fluctuation characteristics were shown at some stations such as NR1 (Kyungho-River 1), NR2 (Kyungho-River 2), NR3 (Nam-River), NR6 (Nam-River 2A). In addition, the flow-adjusted seasonal Kendall results showed that the BOD concentration was "up trand" due to the flow at the NR3 (Nam-River) station. The COD concentration was "up trand" due to the flow at NR1 (Kyungho-River 1) and NR2 (Kyungho-River 2) located upstream of the Nam-River. The effect of influent flow on water quality varies according to each site and analysis item. Therefore, for the effective water quality management in the Nam-River, it is necessary to take measures to improve the water quality at the point where the water quality is continuously "up trand" during the study period.

Evaluation on In-plane Shear Strength of Lightweight Composite Panels (경량 복합패널의 면내 전단 성능 평가)

  • Hwang, Moon-Young;Kang, Su-Min;Lee, Byung-yun;Kim, Sung-Tae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.1
    • /
    • pp.9-20
    • /
    • 2019
  • The number of natural disasters in Korea, such as earthquakes, is increasing. As a result, there is growing need for temporary residences or shelters for disaster conditions. The aim of this study was to produce post-disaster refugees housing differentiated from existing shelters using lightweight composite panels. To accomplish this, the structural performance of lightweight composite panels was validated, and an in-plane shear strength test was conducted according to the ASTM E72 criteria among the performance test methods for panels. As a result of the experiment, the maximum load for each specimen under an in-plane shear load was determined. All the experiments ended with the tear of the panel's skin section. The initial stiffness of the specimens was consistent with that predicted by the calculations. On the other hand, local crushing and tearing, as well as the characteristics of the panel, resulted in a decrease in stiffness and final failure. Specimens with an opening showed a difference in stiffness and strength from the basic experiment. The maximum load and the effective area were found to be proportional. Through this process, the allowable shear stress of the specimens was calculated and the average allowable shear stress was determined. The average ultimate shear stress of the lightweight composite panels was found to be $0.047N/mm^2$, which provides a criterion of judgement that could be used to expect the allowable load of lightweight composite panels.

Effects of Shading Treatments on Growth and Physiological Characteristics of Aruncus dioicus var. kamtschaticus (Maxim.) H. Hara Seedling (차광처리가 눈개승마 유묘의 생장 및 생리적 특성에 미치는 영향)

  • Lee, Kyeong Cheol;Han, Sang Kyun;Kwon, Young Hyoo;Jeon, Seong Ryeol;Lee, Chang Woo;Seo, Dong Jin;Park, Wan Geun
    • Korean Journal of Medicinal Crop Science
    • /
    • v.27 no.1
    • /
    • pp.30-37
    • /
    • 2019
  • Background: This study was conducted to investigate the changes in the photosynthetic parameters, chlorophyll content, chlorophyll fluorescence, and growth characteristics of Aruncus dioicus var. kamtschaticus seedlings under different shading treatments. Methods and Results: The shading treatment was regulated with the shading level (non-shaded, 35%, 55%, and 75% shading). Photosynthetic activities, such as net photosynthetic rate, stomatal conductance, stomatal transpiration rate, and performance index on absorption basis ($PI_{ABS}$)were the highest under 35% shading ($4.36{\mu}mol\;CO_2{\cdot}m^{-2}{\cdot}s^{-1}$, $54.2mmol\;H_2O{\cdot}m^2{\cdot}s^{-1}$, $0.66mmol\;H_2O{\cdot}m^{-2}{\cdot}s^{-1}$, and 1.3, respectively), and the lowest under 75% shading. This implies that the decrease in net photosynthetic rate may be due to an inability to regulate water and $CO_2$ exchanged through the stomata. Thechlorophylla, b, and a + b contents were increased with elevating shading level and the chlorophyll a/b ratio showed non-significant differences. It was found that the dry weight (leaf, shoot, and whole) was the highest (1.14 g, 0.49 g, and 2.31 g, respectively) under 35% shading and the t/R ratio was the highest under 75% shading. Conclusions: It is concluded that 75% shading exhibited a strong reduction of photosynthetic activity, and 35% shading showed the best conditions for the early growth and cultivation of A. dioicus var. kamtschaticus.

Mechanical Properties and Impact Resistance Review of Carbon Fiber Reinforced Cement Composites with Different Fiber Contents and Fiber Lengths (섬유혼입률 및 섬유길이 변화에 따른 탄소섬유 보강시멘트 복합재료의 역학적 특성과 내충격성 검토)

  • Heo, Gwang-Hee;Song, Ki-Chang;Park, Jong-Gun;Han, Yoon-Jung;Lim, Cae-Young
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.4
    • /
    • pp.86-95
    • /
    • 2019
  • Recently, the applications of carbon fiber have been broader than ever when it comes to such industrials as automobiles, ships, aerospace, civil engineering and architecture because of their lightweight-ness and high mechanical properties. This study analyzed mechanical properties and flexural behavior of carbon fiber reinforced cement composites(CFRC) with different fiber contents and fiber lengths, and also impact resistance by natural drop test on mortar specimens was compared and examined. In addition, contents of carbon fiber(CF) were varied by 0.5%, 1.0%, 2.0% and 3.0%. Fiber lengths was used for 6 mm and 12 mm, respectively. As a result of the test, the flow value was very disadvantageous in terms of fluidity due to the carbon fiber ball phenomenon, and the unit weight was slightly reduced. In particular, the compressive strength was decreased with increasing carbon fiber contents. On the other hand, the flexural strength was the highest with 12 mm fiber length and 2% fiber content. As the results of the impact resistance test, the specimens of plain mortar takes about 2~3 times to final fracture, while the specimens of CFRC is somewhat different depending on the increase of the fiber contents. However, when the fiber length is 12 mm and the fiber content is 2%, the impact resistance was the highest.

A Study on the Usefulness of Photogrammetry through 3D Recording of the Rock-carved Standing Buddha in Singyeong-ri, Hongseong (홍성 신경리 마애여래입상의 3차원 기록화를 통한 포토그래메트리의 유용성 연구)

  • Oh, Jun-Young;Kim, Choong-Sik
    • Korean Journal of Heritage: History & Science
    • /
    • v.50 no.3
    • /
    • pp.30-43
    • /
    • 2017
  • The purpose of this study is to improve the usefulness of photogrammetry in the field of cultural heritage recording concentrated on laser scanning. Two measurement methods(laser scanning, photogrammetry) were compared in terms of accuracy and reality for the Rock-carved Standing Buddha in Singyeong-ri, Hongseong. With regard to accuracy, the distances of major points by both shape information and between the two shape information were compared. Only a deviation of about 1mm was found in the distance measurement of the major points by both shape information. In particular, the average distance between two shape information identified through aligning was only about 0.01mm. Also, the absolute deviation within about 2mm accounted for 70% of the total, and the absolute deviation within about 3.5mm was found to be 95.4% of the total. These values showed very high similarity between laser scanning and photogrammetry-based shape information. In respect of reality, the carved depth, texture, and patterns were compared. As a result of comparing four cross-sectional shapes, only slight differences were found in the shape information of both measurement techniques and similar shapes were identified. The overall texture of both shape information was also similar. However, the detailed shape based on the photogrammetry with decimation is realized with a smoother texture than the original and laser scanning. In particular, Photogrammetry also realistically expressed the various ornaments carved in the Rock-carved Buddha and the patterns with shallow depths were comparatively detailed.

Study on Influencing Factors of Adhesive Strength for Polymer Coating on Metal Adherend by Dolly Test (돌리테스트로 고분자 코팅층과 금속 피착재의 접착강도 측정시 영향인자에 대한 연구)

  • Baeg, Ju-Hwan;Park, Hyun;Lee, Sung In;Ha, Yungeun;Cho, Young-Rae
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.26 no.2
    • /
    • pp.1-8
    • /
    • 2019
  • The demand and importance of adhesives and paint coatings applied to solid surfaces such as metals, ceramics, and plastics are increasing. In this study, the influencing factors on the adhesive strength between the polymer coating and the metal adherend were investigated by Dolly test when the adhesive or the paint coating was applied on the metal adherend. Two-component epoxy adhesive was used as the adhesive, and EH2350, a two-component epoxy paint for anti-corrosion, was used as the paint. Especially, the effect of adherend metals(Al, Fe, STS, Cu, Zn), surface roughness and surface contamination(tap water, salt water) on adhesive strength was studied as influencing factors. The adhesive strength between adhesive and adherend was different when the type of metal adherend was different even when the same adhesive was used. It was found that spray water cleaning was necessary before the paint coating process on the surface of the oxide contaminated adherend with tap water or salt water. As a result of this study, it was confirmed that Dolly test can be widely used in the future to measure adhesive strength between paint coating and adherend.

Manufacture of 3D Textile Preform and Study on Mechanical Properties of Composites (3D Textile 프리폼 제조 및 복합재료 기계적 특성 연구)

  • Jo, Kwang-Hoon;Klapper, Vinzenz;Kim, Hyeon-Woo;Lee, Jeong-Woon;Han, Joong-Won;Byun, Joon-Hyung;Joe, Chee-Ryong
    • Composites Research
    • /
    • v.32 no.1
    • /
    • pp.65-70
    • /
    • 2019
  • The aircraft composites wing parts are usually integrated with adhesive or fastener. These laminated composites have weak interlaminar strength, which can lead to delamination. In order to compensate the disadvantages of laminated composites, it is possible to improve the strength, durability, shock and fatigue resistance by reinforcing the fiber in the thickness direction. In addition, using a single structure near-net-shape saves the manufacturing time and the number of fasteners, thus can reduce the overall cost of the composite parts. In this study, compression test, tensile test and open-hole tensile test are carried out for three structural architecture of 3D (three-dimensional) textile preforms: orthogonal(ORT), layer-to-layer(LTL) and through-the-thickness(TTT) patterns. Among these, the orthogonal textile composite shows the highest Young's modulus and strength in tensile and compression. The notch sensitivity of the orthogonal textile composite was the smallest as compared with UD (unidirectional) and 2D (two-dimensional) fabric laminates.

An Analysis on the Status of Barrier Free Design Certifications in Center for Elderly (경로당 건축물의 장애물 없는 생활환경 인증실태 분석)

  • Lee, Jeong-Soo;Oh, Young-Sook;Eun, Dong-Shin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.12
    • /
    • pp.313-320
    • /
    • 2018
  • The purposes of this study were to verify the status of Barrier Free Design Certification in the center for the elderly. To achieve these purposes, the architectural characteristics of the center for elderly and the status of Barrier Free Design Certification was analyzed. The results of this study were as follows. (1) The functional composition of centers for the elderly are similar regardless of the location, but the area and shape of the plot are very different according to the location. (2) According to an analysis on the status of Barrier Free Design Certification in centers for elderly, the sanitation and intermediate facilities are necessarily considerable adjustment. (3) For the accessability and conveniences of Barrier Free Design Certification in a small building, such as centers for the elderly, they are necessary to simplify the self-assessment documents, minimize the period for judging, and reducing the fees for certification.