• Title/Summary/Keyword: YAG-Laser

Search Result 1,154, Processing Time 0.019 seconds

Development of an Industrial Nd:YAG Laser and its Applications (용접용 Nd:YAG 레이저의 개발과 응용)

  • 김광석
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 1989.02a
    • /
    • pp.32-35
    • /
    • 1989
  • A 150W industrial Nd:YAG laser was developed. The thermal lensing effect was examined and the radius and position of rear mirror were optimized for higher efficiency. The efficiency of 2.5% was achieved. Also, the performance of laser welding in fine thermocouples and between high-temperature-melting dissimilar metals were investigated.

  • PDF

The Weldability of Aluminum Ball in Electrolyte Injection Hole by Nd:YAG Laser (리튬이온전지의 전해액 주입구 볼에 대한 Nd:YAG 레이저 용접성)

  • Kim, Jong-Do;Yoo, Seung-Jo;Kim, Jang-Soo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.30 no.6
    • /
    • pp.740-745
    • /
    • 2006
  • This study suggested the occurrence source of weld-defects and its solution methods in a welding of Electrolyte injection hole by pulsed Nd:YAG laser. In experiment, the ramp down was used in order that solidification crack was removed. Furthermore. shrinkage stress and heat input were reduced by changing of weld trajectory and defocused distance. As a results of a experiment, a sound weld bead shape and crack-free weld bead can be obtained. In conclusion this show that the welding stability is greatly affected by modulation of laser pulse shape for the same laser energy and welding parameters.

Welding Characteristics of SCP1 on CW Nd:Yag Laser (CW Nd:YAG 레이저에 의한 SCP1의 용접특성)

  • Shin, Byung-Heon;Yoo, Young-Tae;Shin, Ho-Jun;Yun, Chul-Jung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.24 no.5
    • /
    • pp.35-43
    • /
    • 2007
  • Laser welding of metals has been widely used to improve a wear resistance and a corrosion resistance of the industrial parts. The objective of this research works is to investigate the influence of the process parameters, such as the welding for metals with CW Nd:YAG lasers. The bead-on-plate welding tests are carried out for several combinations of the experimental conditions. In order to quantitatively examine the characteristics of the butt welding, the welding quality of the cut section, stain-stress behavior and the hardness of the welded part are investigated. From the results of the investigation, it has been shown that the optimal welding condition without defects in the vicinity of the welded area and with a good welding quality is 1325W of the laser power, and 1.4m/min of laser welding speed.

Development of Nd-Yag Laser Marking System for Cylinderical Parts (Nd-Yag 레이저를 이용한 원통 형상 표면 마킹 시스템 개발)

  • Lee, Se-Han;Kang, Jae-Gwan
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.9 no.5
    • /
    • pp.70-75
    • /
    • 2010
  • In this paper, laser marking systems dedicated to cylinderical parts was developed. We first develop the marking device which consists of Nd-Yag laser, galvano scanner and additional rotational axis, then develop algorithm for supporting the digital image with bmp data format. Additional rotational axis is so attached as to rotate the cylinderical parts for marking its whole surface. The image is separated into line by line and the separated line image is sent to galvano scanner while rotating the additional axis simultaneously. CxImage library, famous open source code, is employed for the image processing. The developed method was tested with various images and shows that it reduces marking time significantly without reducing marking quality.

A Study on the Antibacterial Effects of Pulsed Nd: YAG Laser Irradiation to Streptococcus Mutans (Pulsed Nd : YAG Laser 조사의 Streptococcus mutans에 대한 효과)

  • Woo-Cheon Kee
    • Journal of Oral Medicine and Pain
    • /
    • v.22 no.1
    • /
    • pp.15-22
    • /
    • 1997
  • In order to investigate the antibacterial effects of pulsed Nd:YAG Laser concerning to Streptococcus mutans, Streptococcus mutans was cultured and standardized and plated in 96 well plates. After that, black dye and chlorhexidine were applied and pulsed Nd:YAG Laser was irradiated to plates. Experimental groups which was applied with black dye and chlorhexidine were divided into 5 groups by concentration. And experimental groups and control group were subdivided as unlased and lased of 20, 40, and 60J. After laser irradiation, All groups were plated in agar plates and incubated for 18 hours. Bacterial colonies were counted and analysed comparitively, and the temperature of culture medium was measured on every laser irradiation. The results were obtained as follows; 1. In case of laser irradiation only, there is no significant reduction in number of Streptococcus mutans by irradiated energy of laser. 2. In case of black dye application, there is no difference by concentration of black dye but there is decrease when applied Laser and black dye simultaneously. 3. When applied chlorhexidine, the number of Streptococcus mutans was decreased according to increase of concentration, but there is no difference by irradiated energy of laser. 4. The temperature of culture medium was increased according to increase of irradiated energy of Laser, and the number of Streptococcus mutans was reduced remarkably just above 50 centigrade and killed above 70 centigrade. As above results, pulsed Nd:YAG Laser has well-absorbing affinity to black dye. And antibacterial effect of pulsed Nd:YAG Laser against Streptococcus mutans is seemed to be due to increase of temperature.

  • PDF

Growth of Nd:YAG single crystal by czochralski method and characteristics of laser generation (Czochralski 방법에 의한 Nd : YAG 단결정의 육성 및 레이저 출력특성)

  • 이상호;김한태;배소익;정수진
    • Korean Journal of Optics and Photonics
    • /
    • v.9 no.3
    • /
    • pp.175-180
    • /
    • 1998
  • Nd:YAG single crystal widely used as solid state laser was grown by Czochralski method. <111> single crystal with 0.9at% of $Nd^{3+}$ was grown from the Czochralski furnace with a automatic diameter control system. The vertical temperature gradient in the liquid was the major factor that influence the crystal quality, and the crystal diameter was controlled by the home made computer program. The crystal boule with $\phi$50mm$\times$ι100mm effective size was cut, polished, and antireflection coated. The optical evaluation such as absorption spectrum, fluorescence spectrum coincide with typical features of Nd:YAG single crystal. The laser rod was assembled into the CW laser generator with a Kr lamp. The maximum CW laser output was 70 W and the threshold power and efficiency was 1.3kW and 1.64% respectively.

  • PDF

A COMPARATIVE STUDY OF WOUND HEALING AFTER SKIN INCISION WITH SCALPEL, $CO_2$, AND Nd:YAG LASER IN RATS (수술칼, $CO_2$ 및 Nd:YAG 레이저에 의한 절개 창상의 치유에 관한 비교 연구)

  • Choi, Jae-Sun;Ryu, Sun-Youl
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.22 no.1
    • /
    • pp.33-42
    • /
    • 2000
  • The purpose of this study was to compare the wound healing process after skin incision using scalpel, $CO_2$ laser and pulsed Nd:YAG laser in rats. After skin on the back was incised 3 cm long, rats were sacrificed at 1, 3, 7, 14, 21 and 28 days. Macroscopic, histologic and immunohistochemical examinations using the collagen type IV and the CD34 antibodies which are necessary to the forming process of new capillary were performed. Results obtained were as follows ; Macroscopically the initial wound healing of the laser group was about $1{\sim}2$ weeks slower than that of the scalpel group. There weren't however any remarkable differences in all groups in 4 weeks after incision. By histologic finding, acute inflammatory cells were more prominent during the initial wound healing in the scalpel group than in the other groups. Epithelialization started in the order of scalpel, $CO_2$ and Nd:YAG laser group after skin incision. By the Masson's trichrome stain, collagen synthesis in the Nd:YAG laser group was more slowly initiated than in the other groups. But it was completed at the $3{\sim}4$ weeks in all groups. Immunohistochemically, collagen type IV and CD34 expression were markedly increased at 2 weeks in the scalpel and $CO_2$ laser group. Meanwhile, in the Nd:YAG laser group, these reactions were observed later tan the other groups. Collagen type IV and CD34 expression were decreased in all groups after 4 weeks. These results suggest that $CO_2$ and Nd:YAG laser showed similar healing process compared with scalpel and a potential substitute for scalpel in skin incision.

  • PDF

Effects of Acid-etching, CO2 and Nd:YAG Lasing on the Dentin Surface (산부식과 CO2 및 Nd:YAG 레이저 조사에 따른 상아질 표면의 변화)

  • Lee, Jae-Hak;Park, June-Sang;Ko, Myung-Yun
    • Journal of Oral Medicine and Pain
    • /
    • v.25 no.1
    • /
    • pp.129-144
    • /
    • 2000
  • The purpose of this study was to examine dentin surface changes of extracted sound third molar specimens which were etched with 10% maleic acid and irradiated at $7-140J/cm^2$ with $CO_2$ and at $156-280J/cm^2$ with Nd:YAG laser. The results were as follows. 1. Dentin surfaces etched with 10% maleic acid and then irradiated at below of $42J/cm^2$ with $CO_2$ laser showed the retentive morphology for resin restoration. 2. Dentin surfaces irradiated at below of $42J/cm^2$ with $CO_2$ laser showed the increased acid-resistance. 3. Dentin surfaces irradiated at $218-280J/cm^2$ with Nd:YAG laser showed the retentive morphology. 4. Dentin surfaces irradiated at $218-280J/cm^2$ with Nd:YAG laser and etched 10% maleic acid and then $218-280J/cm^2$ with Nd:YAG laser showed the increased acid-resistance.

  • PDF