• Title/Summary/Keyword: YAG-Laser

Search Result 1,152, Processing Time 0.035 seconds

Spray Characteristics of the Injector for the APU Gas Tubine Engine at Airplane Operating Conditions (항공기 작동조건에 따른 APU 가스터빈엔진 연료노즐의 분무특성)

  • Choi, Chea-Hong;Choi, Seong-Man;Lim, Byeong-Jun
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.12 no.1
    • /
    • pp.29-36
    • /
    • 2008
  • Spray characteristics for APU gas turbine engine are investigated. In the test, four flight conditions such as sea level idle, sea level max power, 20,000 feet idle, 20,000 feet max power are used as spray experimental conditions. Spray visualization was performed by using ND-YAG laser bean PDPA(Phase Doppler Particle Analyzer) was used for measuring the particle diameter and velocity from 20 mm to 100 mm from discharge orifice. From the test result, SMD is $90{\sim}95\;{\mu}m$ 맛 20,000 ft idle condition and SMD is $60{\sim}75\;{\mu}m$ at sea level idle condition. Also SMD is $55{\sim}65\;{\mu}m$ at 20,000 ft max power condition and SMD is $30{\sim}70\;{\mu}m$ at sea level max power condition. In the case of 20,000 ft idle condition, combustion instability could be occurred due to the higher drop diameter. Therefore it is necessary to decrease the droplet diameter in the high altitude condition.

A study of the development of a simple driver for the Pockels cell Q-switch and Its characteristics (단순화된 Pockels cell Q-switch용 구동기 개발 및 특성에 관한 연구)

  • Park, K.R.;Joung, J.H.;Hong, J.H.;Kim, B.G.;Moon, D.S.;Kim, W.Y.;Kim, H.J.;Cho, J.S.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.2116-2118
    • /
    • 2000
  • In the technique of Q-switching, very fast electronically controlled optical shutters can be made by using the electro-optic effect in crystals or liquids. The driver for the Pockels cell must be a high-speed, high-voltage switch which also must deliver a sizeable current. Common switching techniques include the use of vacuum tubes, cold cathode tubes, thyratrons, SCRs, and avalanche transistors. Semiconductor devices such as SCRs, avalanche transistors, and MOSFETs have been successfully employed to drive Pockels cell Q-switch. In this study, a simple driver for the Pockels cell Q-switch was developed by using SCRs, pulse transformer and TTL ICs. The Pockels cell Q-switch which was operated by this driver was employed in pulsed Nd:YAG laser system to investigate the operating characteristics of this Q-switch. And we have investigated the output characteristics of this Q-switch as a function of the Q-switch delay time to Xe flashlamp current on.

  • PDF

레이저 유기 충격파를 이용한 나노 Trench 에서의 나노입자제거

  • Kim, Jin-Su;Lee, Seung-Ho;Park, Jin-Gu
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2009.05a
    • /
    • pp.25.1-25.1
    • /
    • 2009
  • Pattern 웨이퍼 상의 오염입자 제거는 반도체 산업의 주된 과제 중 하나이다. Pattern의 선폭이 좁아짐에 따라 Pattern에 손상을 가하지 않고 오염입자를 제거 하는 것은 더욱 어려워지고 있다. 그뿐만 아니라 기존 습식세정 공정에서의 화학액에 의한 환경오염 및 박막의 손실도 문제가 되기 시작했다. 이러한 문제를 해결하기 위해 기존 세정공정에서 화학액의 농도를 낮추고 Megasonic 등을 이용하여 세정력을 보완하는 방법들이 연구되고 있다. 하지만 습식세정의 경우 강한 화학작용으로 인한 표면 손상 및 물 반점의 문제는 여전히 이슈가 되고 있다. 이러한 단점을 극복하기 위하여 건식 세정법이 제시되고 있으며 이 중 레이저 충격파는 레이저를 집속시켜 발생된 충격파를 이용하여 입자를 제거하기 때문에 국부적인 세정이 가능하며 세정력 조절이 가능하여 손상이 세정을 할 수 있다. 그러나 Pattern의 구조에 의해 전되는 세정력의 차이가 발생하고 Trench 내부의 오염입자제거 문제점이 발생할 수 있다. 시편은 Si STI Pattern을 100 nm PSL Particle (Red Fluorescence, Duke Scientific, USA) 을 50ppm 농도로 희석시킨 IPA에 dipping 하여 오염시킨 후 N2 Gas를 이용하여 건조하여 준비하였다. 그리고 레이저 충격파 세정 시스템은 최대 에너지 1.8 J까지 가능한 레이저를 발생하는 1,064 nm Nd:YAG 레이저를 이용하여 실험하였다. 레이져 충격파 실험은 충격파와 시편사이의 거리, gap distance와 에너지를 변환하여 세정효율을 관찰하였다. 세정효율은 세정 전후의 입자 감소량을 현광현미경 (LV-150, Nikon, Japan)를 이용하여 측정하였다. 그 결과, Trench 내부의 오염입자의 경우 Trench 밖의 오염입자에 비해 세정효율이 떨어지는 것으로 나타났으나 시편과 레이저 초점과의 거리가 가까워짐에 따라 Trench 내부의 오염입자에 대한 세정 효율을 증가시킬 수 있었다.

  • PDF

Development of Trimming Technology in High-fine Resistor Using U.V. Laser (자외선 레이저를 이용한 고정밀 저항체 가공기술 개발)

  • Noh, S.S.;Kim, D.H.;Chung, G.S.;Kim, H.P.;Kim, K.H.
    • Journal of Sensor Science and Technology
    • /
    • v.11 no.6
    • /
    • pp.358-364
    • /
    • 2002
  • In this paper, we used U.V.(wavelength, 355nm) laser for adjusting Pt thin films temperature sensor to $100{\Omega}$ at $0^{\circ}C$. Internationally, A-class tolerance of temperature sensor is $0.06{\Omega}$ at $0^{\circ}C$. This is under value of $0.15^{\circ}C$, actually, so high-fine trimming technology is essential to this process. The width of trimmed lines was about $10{\mu}m$ and the best trimming of Pt thin films of $1{\sim}1.5{\mu}m$ was carried out with power : 35mW, rep. rate frequency : 200Hz and bite size : $1.5{\mu}m$. And using photolithography process, 96 resistors were fabricated in $2"{\times}2"$ substrate as the proportion of $79{\sim}90{\Omega}$ and $91{\sim}102{\Omega}$ is 42.7% and 57.3%, respectively. As result of trimming resistors to the target value of $109.73{\Omega}$ at $25^{\circ}C$, 82.3% of resistors had the tolerance within ${\pm}0.30{\Omega}$ and the others(17.7%) were within ${\pm}0.06{\Omega}$ of A-class tolerance.

Direct Intratumoral Injection of Ethanol in the Patients with Obstruction of Major Bronchus (주기관지 폐색환자에서 종양내 ETHANOL 주입치료 효과)

  • Lee, Bong-Chun;Yum, Ho-Kee;Choi, Soo-Jeon;Kim, Dong-Soon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.40 no.5
    • /
    • pp.495-500
    • /
    • 1993
  • Background: For the relief of the occlusion of major bronchi, laser therapy, radiation therapy or combined therapy is generally used. But the effect of radiation therapy is very slow and not consistent and laser therapy requires expensive equipments and technical expertise with occasional serious side effects. Direct ethanol injection has been widely used for the control of bleeding in gastrointestinal lesion, esophageal varices or renal cell carcinoma with good results. So we tried direct injection of ethanol into the tumor to relieve the obstruction of major bronchus in 11 patients. Method: All procedures were done under the fiberoptic bronchoscopy with continuous oxygen supplement and aliquoted 0.5-1.0 ml of absolute ethanol directly into the tumor through the endobronchial aspiration needle. The tumor was endoscopically removed with a biopsy forceps immediately after ethanol injection. The whole procedure was repeated 3-4 days interval until the lumen opens. Usually after 2-3 trials of ethanol injection, the lumen opened up. Results: The immediate effect of ethanol injection was whitening of the mucosa and prompt cessation of bleeding. The late effect was necrosis of the tumor. The final results of this procedure were improvement of symptoms and reexpnasion of the lung in all patients. $FEV_{1.0}$ and FVC were improved and $PaO_2$ was increased from $68.1{\pm}9.2$ mmHg to $83.9{\pm}8.1$ mmHg, $SaO_2$: from $94{\pm}8.5%$ to $96.6{\pm}1.1%$, and $AaDO_2$ was reduced from $26.5{\pm}8.5$ mmHg to $10.9{\pm}9.1$ mmHg. Conclusion: Direct ethanol injection into the tumor tissue is a rapid, cheap and relatively safe method of relieving the complete occlusion of major bronchus.

  • PDF

A STUDY ON THE RELATIONS OF VARIOUS PARTS OF THE PALATE FOR PRIMARY AND PERMANENT DENTITION (유치열과 영구치열의 구개 각부의 관계에 관한 연구)

  • Lee, Yong-Hoon;Yang, Yeon-Mi;Lee, Yong-Hee;Kim, Sang-Hoon;Kim, Jae-Gon;Baik, Byeong-Ju
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.4
    • /
    • pp.569-578
    • /
    • 2004
  • The purpose of this study was to clarify the palatal arch length, width and height in the primary and permanent dentition. Samples were consisted of normal occlusions both in the primary dentition(50 males and 50 females) and in the permanent dentition(50 males and 50 females). With their upper plaster casts were used and through 3-dimensional laser scanning(3D Scanner, DS4060, LDI, U.S.A.), cloud data, polygonization, section curve and loft surface, fit and horizontal plane were based to measure the palatal arch length, width and height(Surfacer 10.0, Imageware, U.S.A.). T-tests were applied for the statistical analyze of the data. The results were as follows : 1. In the measurement values, the values of the male were higher than those of the female except primary anterior palatal height. There were not only statistically significant differences in anterior palatal width(p<0.05) and posterior palatal width(p<0.01) in primary dentition but palatal width(p<0.05), anterior palatal length(p<0.01), middle and posterior palatal length(p<0.05) in permanent dentition between male and female. 2. In the indices of palate, there were statistically significant differences in height-length index(p<0.05) and width-length index(p<0.01) between male and female in primary dentition. In permanent dentition, there was statistically difference between male and female. 3. In the measurement values, posterior palatal width was increased most greatly. Posterior palatal height, anterior palatal width and anterior palatal length were followed by descending order. On the other hand, anterior palatal height and posterior palatal length were decreased. 4. In the indices of palate, the height-length index, the width-length index and posterior height-width index were increased, but the others were decreased.

  • PDF

Ambient CO2 Measurement Using Raman Lidar (라만 라이다를 이용한 대기 중 이산화탄소 혼합비 측정)

  • Kim, Daewon;Lee, Hanlim;Park, Junsung;Choi, Wonei;Yang, Jiwon;Kang, Hyeongwoo
    • Korean Journal of Remote Sensing
    • /
    • v.35 no.6_3
    • /
    • pp.1187-1195
    • /
    • 2019
  • We, for the first time, developed a Raman lidar system which can remotely detect surface CO2 volume mixing ratio (VMR). The Raman lidar system consists of the Nd: YAG laser of wavelength 355 nm with 80 mJ, an optical receiver, and detectors. Indoor CO2 cell measurements show that the accuracy of the Raman lidar system is calculated to be 99.89%. We carried out the field measurement using our Raman lidar at Pukyong National University over a seven-day period in October 2019. The results show good agreement between CO2 VMRs measured by the Raman lidar (CO2 Raman Lidar) and those measured by in situ instruments (CO2 In situ) which located 300 m and 350 m away from the Raman lidar system. The correlation coefficient (R), mean absolute error (MAE), and root mean square error (RMSE) between CO2 In situ and CO2 Raman Lidar are 0.67, 2.78 ppm, and 3.26 ppm, respectively.

A Case of Primary BALT Lymphoma Limited to the Trachea (기관에 국한되어 발생한 BALT 림프종 1예)

  • Oh, Hyun Jong;Kim, Hee Jeong;Hwang, Eun Mee;Kim, Do Young;Kim, Yang Hyun;Yoon, Hyoung Kyu;Moon, Hwa Sik;Park, Sung Hak;Song, Jeong Sup
    • Tuberculosis and Respiratory Diseases
    • /
    • v.55 no.2
    • /
    • pp.198-205
    • /
    • 2003
  • Primary pulmonary lymphoma is rare, especially lymphomas arising in and limited to the tracheal wall without pulmonary parenchymal involvement are extremely rare. Bronchus-associated lymphoid tissue (BALT) lymphoma accounts for the majority of tracheal lymphomas. BALT lymphoma reveals distinct clinicopathologic features and remains localized for prolonged periods. The diagnosis is made histopathologically. Optimal management of these rare lesions has not been established. But, chemotherapy and radiation therapy all have been tried with favorable short-time results. The prognosis of BALT lymphoma is relatively good. We present here a case of BALT lymphoma of the tracheal wall which had responded to bronchoscopic ND-YAG laser therapy and local radiation therapy.

Velocity Field Measurement of Flow Inside SNOUT of Zinc Plating Process ( I ) (용융아연 도금공정에서의 SNOUT 내부 유동장 해석 ( I ))

  • Shin, Dae Sig;Choi, Jayho;Lee, Sang-Joon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.10
    • /
    • pp.1265-1273
    • /
    • 1999
  • PIV(Particle Image Velocimetry) velocity field measurements inside the snout of a1/10 scale model of the Zn plating process were carried out at the strip speed $V_s=1.5m/s$. Aluminum powder particles ($1{\mu}m$) and atomized olive oil ($3{\mu}m$) were used as seeding particles to simulate the molten Zinc flow and deoxidization gas flow, respectively. A pulsed Nd:Yag laser and a $2K{\times}2K$ high-resolution CCD camera were synchronized for the PIV velocity field measurement. From flow visualization study, it is found that the liquid flow in the Zn pot is dominantly governed by the uprising flow caused by the rotating sink roll, with its effect on the steel strip inside the snout largely diminished by installing of the snout. The deoxidization gas flow in front of the strip inside the snout can be characterized by a large-scale vortex rotating clockwise direction formed by the moving strip. In the rear side of the strip, a counter-clockwise vortex is formed and some of the flow entrained by the moving strip impinges on the free surface of molten zinc. The liquid flow in front of the strip is governed by the flow entering the snout, caused by the spinning sink roll. Just below the free surface a counter-clockwise vortex is formed near the snout wall. The moving strip affects dominantly the flow behind the strip inside the snout, and large amount of the liquid flow follows the moving strip toward the sink roll. The thickness of the flow following the strip is very thin in the front side due to the uprising flow, however thick boundary layer is formed in the rear side of the strip. Its thickness is increased as moving downstream toward the sink roll. Inside the snout, the deoxidization gas flow above the free surface is much faster than the liquid flow in the zinc pot. Due to the larger influx of the flow following the moving strip in the rear side of the strip, higher percentage of imperfection can be anticipated on the rear surface of the strip.

Two Cases of Diagnosis and Removal of Endobronchial Hamartoma by Cryotherapy via Flexible Bronchoscopy

  • Sim, Jae Kyeom;Choi, Jong Hyun;Oh, Jee Youn;Cho, Jae Young;Moon, Eul Sun;Min, Hye Sook;Lee, Byung Hyun;Park, Min Seon;Hur, Gyu Young;Lee, Sung Yong;Shim, Jae Jeong;Kang, Kyung Ho;Min, Kyung Hoon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.76 no.3
    • /
    • pp.141-145
    • /
    • 2014
  • Although endobronchial hamartoma is a rare benign tumor, most patients with endobronchial hamartoma have respiratory symptoms such as obstructive pneumonia, hemoptysis, cough, or dyspnea due to bronchial obstruction. It can cause irreversible post-obstructive pulmonary destruction, thus early diagnosis and treatment is very important. Recently, there have been cases of neodymium-doped yttrium aluminum garnet (Nd:YAG) laser and electrocautery procedures for bronchoscopic treatment of malignant or benign central airway obstruction with comparable therapeutic efficacy and few complications. Bronchoscopic cryotherapy is a newly developed technique for management of central airway obstruction. Moreover, it provides diagnostic methods with improving diagnostic yield and safety. We report two cases of endobronchial hamartoma, each diagnosed and definitively treated with bronchoscopic techniques. Endobronchial biopsy and removal was successfully performed by cryotherapy via flexible bronchoscopy without notable complications. Follow-up bronchoscopic examinations excluded residual or recurrent disease.