• Title/Summary/Keyword: Y-Stent

Search Result 472, Processing Time 0.027 seconds

Analysis on the Determinants of Therapeutic Materials Expenditure in National Health Insurance (주요 치료재료 품목군의 건강보험청구액 결정요인분석)

  • Byeon, Jin Ok;Lee, Ju Hyang;Kim, Yu Ri;Lee, Hye Jae
    • Health Policy and Management
    • /
    • v.26 no.4
    • /
    • pp.333-342
    • /
    • 2016
  • Background: The use of therapeutic materials based on new health technology has increased in recent years in the field of medicine, raising concerns for medical practitioners regarding increased spending on the new therapeutic materials amid the rapid population ageing and increase of chronic diseases in Korea. While therapeutic materials have significant importance in the health care system, they have not been given appropriate attention in the academic world of Korea. The purpose of this study is to identify factors that affect the growth of expenditure on therapeutic materials and to derive implications for an effective management considering the diversity of therapeutic materials. Methods: Using the claims data of the National Health Insurance Services, specific utilization patterns of groups of therapeutic materials in the middle classification level of Health Insurance Review and Assessment Service from 2007 to 2014 were analyzed. Four categories (J5083: drug eluting coronary stent, D0302: nonmetallic anchor, K6014: gauze, K6023: gauze) that exhibit unique patterns with respect to price and volume were selected. Then, decomposition analysis was performed to identify the largest contributor to the spending growth by dividing the products into existing, new, and abandoned products for the period between 2010 and 2013. Results: The effect of new products had larger impact on spending growth than the effect of core items in drug eluting coronary stent (J5083) and nonmetallic anchor (D0302). In addition, existing products in general included items priced relatively lower when compared with another item manufactured by the same company. In the gauze category, however, existing products had the largest impact on expenditure and the effect of volume was greater than that in other categories. Conclusion: This study provides evidence that appropriate management measures classified by the characteristics of therapeutic materials are required for therapeutic materials pricing and reassessment in Korea.

A Case of Biphasic Flow-volume Loop in Left Mainstem Bronchial Stenosis (이상성 기류유량곡선(biphasic flow-volume loop)을 보인 결핵에 기인한 좌주기관지협착 1예)

  • Choi, Soo-Jeon;Jo, Moon-Suk;Lee, Hyuk-Pyo;Kim, Joo-In;Yum, Ho-Kkee
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.2
    • /
    • pp.416-420
    • /
    • 1998
  • Flow-volume loop is known to be useful in the diagnosis of upper airway obstruction. In cases of tracheal obstruction, characteristic features such as fixed or variable upper airway obstruction patterns give clue to the diagnosis. But the flow-volume loop of unilateral mainstem bronchial stenosis is not known well. There is controversy in patterns of flow-volume loop in unilateral mainstem bronchial stenosis (restrictive pattern or biphasic pattern). We report a case of biphasic flow-volume loop in left mainstem bronchial stenosis(4-5 mm in diameter) as a sequela of endobronchial tuberculosis, which recovered normal flow-volume loop after metallic stent insertion and 2 months later showed reappearance of biphasic pattern because of restenosis of left mainstem bronchus due to growth of granulation tissue at the stent site.

  • PDF

Flow Changes by Stent Insertion in Fusiform Aneurysm Models (스텐트 삽입에 의한 방추형 동맥류 내부 유동의 변화)

  • 이계한;서남현
    • Journal of Biomedical Engineering Research
    • /
    • v.22 no.6
    • /
    • pp.535-542
    • /
    • 2001
  • Endovascular embolization technique using a steno is currently used to treat the wide neck aneurysm. Since intraaneurysmal flow characteristics affect thrombus formation and embolisation process. flow visualization technique incorporating photochromic dye was used to elucidate hemodynamic changes by stenting Inside the fusiform aneurysm models. Qualitative observation of flow field and measurement of wall shear rates were Performed at five aneurysm wall locations under pulsatile flow. Intraaneurysmal flow motion was reduced and sluggish vortical motion was maintained during late deceleration phase by stenting. Also wall shear rates were reduced and OSI's were increased in the stented model. These flow characteristics Provide hemodynamic environment favorable for thrombus formation and intimal hyperplasia. The results of this study show hemodynamic changes by stenting Promote thrombus formation and aneurysm embolisation.

  • PDF

Measurement of Porcine Aortic and Pulmonary Valve Geometry and Design for Implantable Tissue Valve (돼지 대동맥, 폐동맥의 근위부 기하학적 구조 측정을 통한 판막 구조 수치의 계량화와 판막 도안에 관한 연구)

  • Park, Sung-Joon;Kim, Yong-Jin;Nam, Jin-Hae;Kim, Soo-Hwan;Lee, Chang-Ha;Lim, Hong-Gook
    • Journal of Chest Surgery
    • /
    • v.43 no.6
    • /
    • pp.602-613
    • /
    • 2010
  • Background: As life expectancy has been increased, the cardiac valve disease has been increased. In past, mechanical valve for valve replacement surgery was used widely, but it has many weaknesses, such as hemorrhage, teratogenic effect caused by warfarin, acute mechanical failure, taking warfarin during life, etc. So, the tissue valve is used widely and researches for durability of tissue valve are in progress. Tissue valves being used are all imported in Korea, and there is a lack of information on its geometry and design. So, we studied the geometry of porcine aortic and pulmonary valve, and tried to suggest theoretical basis for making the aortic and pulmonary valve. Material and Method: We harvested aortic and pulmonary valves of 25 pigs and measured the geometry of valve at fresh and glutaraldehyde (GA) fixed state. In each group, we measured the diameter of the base, diameter of commissure, valve height, commissural height, etc. Also, for making implantable porcine and bovine pericardial valve, we designed the valve stent form, thickness, height, and leaflet size, form, thickness by different size of valve. Result: The aortic and pulmonary valve geometry and ratio were measured in each group. The right coronary cusp of aortic valve and right facing cusp of pulmonary valve was bigger than other cusps and non coronary cusp was smaller than others (RCC: NCC : LCC=1 : 0.88 : 1). Valve height was correlated to the leaflet size. We designed the outer diameter of stented porcine aortic valve from 19 mm to 33 mm and designed stent height and width, using previous measured ratio of each structure, stent thickness, working thickness (for making valve). Also, we designed the size of stent and form for stented bovine pericardial valve, considering diameter of valve, leaflet length, height and leaflet minimum coaptation area. Conclusion: By measuring of 25 pig's aortic and pulmonary valve geometry and ratio, we can make theoretical basis for making implantable stented porcine valve and bovine pericardial valve in various size. After making implantable valve using these data, it is necessary to do in vivo and in vitro researches, furthermore.

The Effect of the Axial Plane on Measurement of Available Bone Height for Dental Implant in Computed Tomography of the Mandible (하악의 전산화 단층사진에서 횡단면이 임플랜트를 위한 가용골 높이의 결정에 미치는 영향)

  • Jhin, Min-Ju
    • Journal of Periodontal and Implant Science
    • /
    • v.32 no.2
    • /
    • pp.379-388
    • /
    • 2002
  • For the success of dental implant, accurate radiographic evaluation is prerequisite for planning the location of the osseointegrated implants and avoiding injury to vital structures. CT/MPR(computed tomography/multiplanar reformation) shows improved visualization of inferior alveolar canal. In order to obtain cross-sectional images parallel to the teeth, the occlusal plane is used to orientate for the axial plane. If the direction of axial plane is not parallel to the occlusal plane, the reformatted cross-sectional scans will be oblique to the planned fixture direction and will not show the actual dimension of the planned fixture's location. If the available bone height which measured in the cross-sectional view is much greater than the actual available bone height, penetration of canal may occur. The aim of this study is to assess the effect of the axial plane to measurement of available bone height for dental implant in computed tomography of the mandible. 40 patients who had made radiographic stents and had taken CT were selected. The sites that were included in the study were 45 molar regions. In the central panoramic scan, the length from alveolar crest to superior border of inferior alveolar canal(available bone height, ABH) was measured in direction of reformatted cross-sectional plane(uncorrected ABH). Then, length from alveolar crest to superior border of canal was measured in direction of stent(corrected ABH). The angle between uncorrected ABH and corrected ABH was measured. From each ABH, available fixture length was decided by $Br{{\aa}}nemark$ system. The results were following ; the difference between two ABHs was statistically significant in both first and second molar(p< 0.01). The percentage of difference more than 1 mm was 8.7% in first molar and 15.5% in second molar. The percentage of difference more than 2 mm was 2.0% in first molar and 6.6% in second molar. The maximum value of difference was 2.5 mm in first molar and 2.2 mm in second molar. The correlations between difference of 2 ABHs and angle was positive correlations in both first and second molar. The correlation coefficient was 0.534 in first molar and 0.728 in second molar. The second molar has a stronger positive correlation. The percentage of disagreement between 2 fixture lengths from two ABHs was 24.4% in first molar and 28.9% in second molar.

Analysis of Risk Factors in Coronary Artery Bypass Surgery (관동맥우회술의 위험인자 분석)

  • 정태은;한승세
    • Journal of Chest Surgery
    • /
    • v.31 no.11
    • /
    • pp.1049-1055
    • /
    • 1998
  • Background: Coronary artery bypass surgery is an important treatment for ischemic heart disease. Recently operative mortality and morbidity has decreased, however further improvement is necessary. Materials and methods: This study was designed to evaluate the risk of operative mortality and morbidity by retrospective method. From 1992 to 1997, eighty six patients underwent coronary artery bypass surgery. There were 61 males and 25 females aged 36~74 years(mean, 58.6). Fourteen patients(16%) had previous PTCA or stent insertion, 41 patients(48%) had unstable angina, and 45 patients(52%) had three vessel disease. Patients with low LV ejection fraction(<35%) were 7 cases and urgent or emergent operation were 10 cases. There were 6 cases of combined surgery which were mitral valve replacement(2 cases), aortic valve replacement(2 cases), ASD repair(1 case), and VSD repair(1 case). Average number of distal anastomosis was 3.5 per patient and average aortic cross clamp time was 115±38.3min. Preoperative risk factors were defined as follows: female, old age(>70 years), low body surface area(<1.5M2), PTCA or stent insertion history, hypercholesterolemia, smoking, hypertension, DM, COPD, urgent or emergent operation, left main disease, low LV ejection fraction(<35%), and combined surgery. Results: Operative mortality was 7cases(8%). As a postoperative morbidity, perioperative myocardial infarction was 6 cases, cerebrovascular accident 6 cases, reoperation for bleeding 5 cases, acute renal failure 4 cases, gastrointestinal complication 3 cases, and mediastinitis 3 cases. In the evaluation of operative risk factors, low body surface area, DM and low LV ejection fraction were found to be predictive risk factors of postoperative morbidity(p<0.05), and low ejection fraction was especially a risk factor of hospital mortality(p<0.05). Conclusions: In this study, low body surface area, DM and low LV ejection fraction were risk factors of postoperative morbidity and low ejection fraction was a risk factor of hospital mortality.

  • PDF

Application of Ultrasonic Nano Crystal Surface Modification into Nitinol Stent Wire to Improve Mechanical Characteristics (나이티놀 스텐트 와이어의 기계적 특성 향상을 위한 초음파 나노표면 개질 처리에 대한 연구)

  • Kim, Sang-Ho;Suh, Tae-Suk;Lee, Chang-Soon;Park, In-Gyu;Cho, In-Sik;Pyoun, Young-Shik;Kim, Seong-Hyeon
    • Progress in Medical Physics
    • /
    • v.20 no.2
    • /
    • pp.80-87
    • /
    • 2009
  • Phase transformation, superelastic characteristics and variation of surface residual stress were studied for Nitinol shape memory alloy through application of UNSM technology, and life extension methods of stent were also studied by using elastic resilience and corrosion resistance. Nitinol wire of ${\phi}1.778$ mm showed similar surface roughness before and after UNSM treatment, but drawing traces and micro defects were all removed by UNSM treatment. It also changed the surface residual stress from tensile to compressive values, and XRD result showed less intensive austenite peak and clear martensite and additional R-phase peaks after UNSM treatment. Fatigue resistance could be greatly improved through removal of surface defects and rearrangement of surface residual stress from tensile to compressive state, and development of surface modification system to improve not only bio-compatability but also resistance to corrosion and wear will make it possible to develop vascular stent which can be used for circulating system diseases which run first cause of death of recent Koreans.

  • PDF

A Study on the dose distribution produced by $^{32}$ P source form in treatment for inhibiting restenosis of coronary artery (관상동맥 재협착 방지를 위한 치료에서 $^{32}$ P 핵종의 선원 형태에 따른 선량분포에 관한 연구)

  • 김경화;김영미;박경배
    • Progress in Medical Physics
    • /
    • v.10 no.1
    • /
    • pp.1-7
    • /
    • 1999
  • In this study, the dose distributions of a $^{32}$ p uniform cylindrical volume source and a surface source, a pure $\beta$emitter, were calculated in order to obtain information relevant to the utilization of a balloon catheter and a radioactive stent. The dose distributions of $^{32}$ p were calculated by means of the EGS4 code system. The sources are considered to be distributed uniformly in the volume and on the surface in the form of a cylinder with a radius of 1.5 mm and length of 20 mm. The energy of $\beta$particles emitted is chosen at random in the $\beta$ energy spectrum evaluated by the solution of the Dirac equation for the Coulomb potential. Liquid water is used to simulate the particle transport in the human body. The dose rates in a target at a 0.5mm radial distance from the surface of cylindrical volume and surface source are 12.133 cGy/s per GBq (0.449 cGy/s per mCi, uncertainty: 1.51%) and 24.732 cGy/s per GBq (0.915 cGy/s per mCi, uncertainty: 1.01%), respectively. The dose rates in the two sources decrease with distance in both radial and axial direction. On the basis of the above results, the determined initial activities were 29.69 mCi and 1.2278 $\mu$Ci for the balloon catheter and the radioactive stent using $^{32}$ P isotope, respectively. The total absorbed dose for optimal therapeutic regimen is considered to be 20 Gy and the treatment time in the case of the balloon catheter is less than 3 min. Absorbed doses in targets placed in a radial direction for the two sources were also calculated when it expressed initial activity in a 1 mCi/ml volume activity density for the cylindrical volume source and a 0.1 mCi/cm$^2$ area activity density for the surface source. The absorbed dose distribution around the $^{32}$ P cylindrical source with different size can be easily calculated using our results when the volume activity density and area activity density for the source are known.

  • PDF

Usefulness of Pulsatile Flow Aortic Aneurysm Phantoms for Stent-graft Placement (스텐트그라프트 장치술을 위한 대동맥류 혈류 팬텀의 유용성)

  • Kim, Tae-Hyung;Ko, Gi-Young;Song, Ho-Young;Park, In-Kook;Shin, Ji-Hoon;Lim, Jin-Oh;Kim, Jin-Hyoung;Choi, Eu-Gene K.
    • Journal of radiological science and technology
    • /
    • v.30 no.3
    • /
    • pp.205-212
    • /
    • 2007
  • To evaluate the feasibility and efficacy of a pulsatile aortic aneurysm phantoms for in-vitro study. The phantoms consisted of a pulsating motor part(heart part) and an aortic aneurysm part, which mimicked true physiologic conditions. The heart part was created from a high-pressured water pump and a pulsatile flow solenoid valve for the simulation of aortic flow. The aortic aneurysm part was manufactured from paper clay, which was placed inside a acrylic plastic square box, where liquid silicone was poured. After the silicone was formed, the clay was removed, and a silicone tube was used to connect the heart and aneurysm part. We measured the change in pressure as related to the opening time(pulse rate, Kruskal-Wallis method) and pressure before and after the stent-graft implantation(n = 5, Wilcoxon's signed ranks test). The changes in blood pressures according to pulse rate were all statistically significant(p<0.05). The systolic/diastolic pressures at the proximal aorta, the aortic aneurysm, and the distal aorta of the model were $157.80{\pm}1.92/130.20{\pm}1.92$, $159.40{\pm}1.14/134.00{\pm}2.92$, and $147.20{\pm}1.480/129.60{\pm}2.70\;mmHg$, respectively, when the pulse rate was 0.5 beat/second. The pressures changed to $161.40{\pm}1.34/90.20{\pm}1.64$, $175.00{\pm}1.58/93.00{\pm}1.58$, and $176.80{\pm}1.48/90.80{\pm}1.92\;mmHg$, respectively, when the pulse rate was 1.0 beat/second, and $159.40{\pm}1.82/127.20{\pm}1.48$, $166.60{\pm}1.67/138.00{\pm}1.87$, and $161.00{\pm}1.22/135.40{\pm}1.67\;mmHg$, respectively, when it was 1.5 beat/second. When pulse rate was set at 1.0 beat/second, the pressures were $143.60{\pm}1.67/90.20{\pm}1.64$, $147.20{\pm}1.92/84.60{\pm}1.82$, and $137.40{\pm}1.52/88.80{\pm}1.64\;mmHg$ after stent-graft implantation. The changes of pressure before and after stent-graft implantation were statistically significant(p<0.05) except the diastolic pressures at the proximal(p =1.00) and distal aorta(p=0.157). The aortic aneurysm phantoms seems to be useful for the evaluation of the efficacy of stent-graft before animal or clinical studies because of its easy reproducibility and ability to display a wide range of pressures.

  • PDF

The Study on the Independent Predictive Factor of Restenosis after Percutaneous Coronary Intervention used Drug-Eluting Stent : Case on MDCT Calcium-Scoring Implementation Patient (약물용출 스텐트를 이용한 관상동맥중재술 후 재협착의 독립적 예측인자에 관한 연구 : MDCT calcium-scoring 시행 환자 대상으로)

  • Kim, In-Soo;Han, Jae-Bok;Jang, Seong-Joo;Jang, Young-Ill
    • Journal of radiological science and technology
    • /
    • v.33 no.1
    • /
    • pp.37-44
    • /
    • 2010
  • We sought to confirm an independent factor about in-stent restenosis (ISR) in the patients who underwent drug-eluting stent (DES) and know a possibility as a predictor of measured coronary artery calcium score by MDCT. A total of 178 patients (159 men, $61.7{\pm}10.0$ years of age) with 190 coronary artery lesions were included in this study out of 1,131 patients who underwent percutaneous coronary intervention (PCI) with DES implantation for significant stenosis on MDCT at Chonnam National University Hospital between May 2006 and May 2009. All lesions were divided into two groups with the presence of ISR : group I (re ISR, N = 57) and group II (no ISR, N = 133). Compared to group II, group I was more likely to be older ($65.8{\pm}9.0$ vs. $60.2{\pm}9.9$ years, p = 0.0001), diabetic (21.8% vs. 52.6%, p = 0.0001), have old myocardial infarction (8.8% vs. 2.3%, p = 0.040), left main stem disease (5.3% vs. 0.8%, p = 0.047), and smaller stent size ($3.1{\pm}0.3\;mm$ vs. $3.3{\pm}0.4\;mm$, p = 0.004). Group II was more likely to be smokers (19.3% vs. 42.1%, p = 0.003), have dyslipidemia (8.8% vs. 23.3%, p = 0.019). Left ventricular ejection fraction, lesion complexity, and stent length were not different between the two groups. Total CAC score was $389.3{\pm}458.3$ in group I and $371.2{\pm}500.8$ in group II (p = 0.185). No statistical difference was observed between the groups in CAC score in the culprit vessel, left main stem, left anterior descending artery, left circumflex artery, and right coronary artery. On multivariate logistic regression analysis, left main stem disease (OR = 168.0, 95% CI = 7.83-3,604.3, p = 0.001), male sex (OR = 36.5, 95% CI = 5.89-2,226.9, p = 0.0001), and the presence of diabetes (OR = 2.62, 95% CI = 1.071-6.450, p = 0.035) were independent predictors of ISR after DES implantation. In patients who underwent DES implantation for significant coronary stenosis on MDCT, ISR was associated with left main stem disease, male sex, and the presence of diabetes. However, CAC score by MDCT was not a predictor of ISR in this study population.