• Title/Summary/Keyword: Y-Stent

Search Result 472, Processing Time 0.031 seconds

A Study on Fatigue Characteristic of Stent Using Finite Element Analysis (나이티놀 와이어 스텐트의 피로도 특성에 대한 유한요소 해석)

  • Kim, Han-Ki;Shin, Il-Gyun;Kim, Dong-Gon;Kim, Seong-Hyeon;Lee, Ju-Ho;Ki, Byoyng-Yun;Suh, Tae-Suk;Kim, Sang-Ho
    • Progress in Medical Physics
    • /
    • v.20 no.3
    • /
    • pp.119-124
    • /
    • 2009
  • Stents are frequently used throughout the human body. They keep pathways open in vascular or nonvascular duct for a long time. Therefore its stability is very important factor. In recent years, aconsiderable amount of research has been carried out in order to estimate mechanical properties of the stent such as expansion pressure behavior, radial recoil and longitudinal recoil using FEM (Finite element analyses). However, published works on simulation of stent fatigue behavior using FEM are relatively rare. In this paper, a nonlinear finite-element methodwas employed to analyses the compression of a stent using external pressure and fatigue behavior. Finite element analyses for the stent system were performed using NASTRAN FX. In conclusion this paper shows how the stent is behaved in the body, and its fatigue behavior.

  • PDF

In-vitro study on the accuracy of a simple-design CT-guided stent for dental implants

  • Huh, Young-June;Choi, Bo-Ram;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Lee, Sam-Sun;Choi, Soon-Chul
    • Imaging Science in Dentistry
    • /
    • v.42 no.3
    • /
    • pp.139-146
    • /
    • 2012
  • Purpose: An individual surgical stent fabricated from computed tomography (CT) data, called a CT-guided stent, would be useful for accurate installation of implants. The purpose of the present study was to introduce a newly developed CT-guided stent with a simple design and evaluate the accuracy of the stent placement. Materials and Methods: A resin template was fabricated from a hog mandible and a specially designed plastic plate, with 4 metal balls inserted in it for radiographic recognition, was attached to the occlusal surface of the template. With the surgical stent applied, CT images were taken, and virtual implants were placed using software. The spatial positions of the virtually positioned implants were acquired and implant guiding holes were drilled into the surgical stent using a specially designed 5-axis drilling machine. The surgical stent was placed on the mandible and CT images were taken again. The discrepancy between the central axis of the drilled holes on the second CT images and the virtually installed implants on the first CT images was evaluated. Results: The deviation of the entry point and angulation of the central axis in the reference plane were $0.47{\pm}0.27$ mm, $0.57{\pm}0.23$ mm, and $0.64{\pm}0.16^{\circ}$, $0.57{\pm}0.15^{\circ}$, respectively. However, for the two different angulations in each group, the $20^{\circ}$ angulation showed a greater error in the deviation of the entry point than did the $10^{\circ}$ angulation. Conclusion: The CT-guided template proposed in this study was highly accurate. It could replace existing implant guide systems to reduce costs and effort.

Ex vivo Morphometric Analysis of Coronary Stent using Micro-Computed Tomography (미세단층촬영기법을 이용한 관상동맥 스텐트의 동물 모델 분석)

  • Bae, In-Ho;Koh, Jeong-Tae;Lim, Kyung-Seob;Park, Dae-Sung;Kim, Jong-Min;Jeong, Myung-Ho
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.2
    • /
    • pp.93-98
    • /
    • 2012
  • Micro-computed tomography (microCT) is an important tool for preclinical vascular imaging, with micron-level resolution. This non-destructive means of imaging allows for rapid collection of 2D and 3D reconstructions to visualize specimens prior to destructive analysis such as pathological analysis. Objectives. The aim of this study was to suggest a method for ex vivo, postmortem examination of stented arterial segments with microCT. And ex vivo evaluation of stents such as bare metal or drug eluting stents on in-stent restenosis (ISR) in rabbit model was performed. The bare metal stent (BMS) and drug eluting stent (DES, paclitaxel) were implanted in the left or right iliac arteries alternatively in eight New Zealand white rabbits. After 4 weeks of post-implantation, the part of iliac arteries surrounding the stent were removed carefully and processed for microCT. Prior to microCT analysis, a contrast medium was loaded to lumen of stents. All samples were subjected to an X-ray source operating at 50 kV and 200 ${\mu}A$ by using a 3D isotropic resolution. The region of interest was traced and measured by CTAN analytical software. Objects being exposed to radiation had different Hounsfield unit each other with values of approximately 1.2 at stent area, 0.12 ~ 0.17 at a contrast medium and 0 ~ 0.06 at outer area of stent. Based on above, further analyses were performed. As a result, the difference of lengths and volumes between expanded stents, which may relate to injury score in pathological analysis, was not different significantly. Moreover, ISR area of BMS was 1.6 times higher than that of DES, indicating that paclitaxel has inhibitory effect on cell proliferation and prevent infiltration of restenosis into lumen of stent. And ISR area of BMS was higher ($1.52{\pm}0.48mm^2$) than that of DES ($0.94{\pm}0.42mm^2$), indicating that paclitaxel has inhibitory effect on cell proliferation and prevent infiltration of restenosis into lumen of stent. Though it was not statistically significant, it showed that the extent of neointema of mid-region of stents was relatively higher than that of anterior and posterior region in parts of BMS as showing cross-sectional 2-D image. suggest that microCT can be utilized as an accessorial tool for pathological analysis.

Morphologic Changes of the Pulmonary Arteries after Stent Implantation on Branch Pulmonary Artery Stenosis - Impact of Pulmonary Insufficiency - (폐동맥 분지협착에 스텐트 삽입 후 유발되는 폐동맥의 형태변화 - 폐동맥 폐쇄 부전의 역할 -)

  • Kim, Me Jin;Kang, Du Cheol;Choi, Jae Young;Lee, Jong Kyun;Sul, Jun Hee;Lee, Sung Kyu
    • Clinical and Experimental Pediatrics
    • /
    • v.46 no.1
    • /
    • pp.67-75
    • /
    • 2003
  • Purpose : Intravascular stent implantation for the treatment of postoperative branch pulmonary artery(PA) stenosis has been used successfully. However, the cross sectional area of contralateral branch PA does not regress in spite of the successful dilation of the stenotic branch PA after stent implantation. We analyzed the morphologic and hemodynamic factors on the size of branch PA after successful stent implantation. Methods : The subjects in our study were 23 children who had undergone stent implantaion from Jan. 1995 to Jul. 2002 in the Division of Yonsei Pediatric Cardiology. We evaluated the cross sectional area index(CSAI) of branch PA before and after stent implantation at follow-up catheterization. We also investigated factors such as residual pulmonary stenosis, pulmonary regurgitation(PR), systolic pressure of right ventricle, and lung perfusion scan. Results : The CSAI of the RPA without stenosis changed from mean $238{\pm}17mm^2/BSA$ to mean $249{\pm}20mm^2/BSA$(P=0.47), but didn't regress. The CSAI of the LPA with stenosis was increased effectively by stent implantation from the mean $102{\pm}12mm^2/BSA$ to mean $125{\pm}11mm^2/BSA$(P< 0.05). At follow up after stent implantation, the CSAI of PA is correlated with the residual PR fraction after stent implantation. Conclusion : In a group with increased residual PR, CSAI of RPA was found to be significantly increased between the pre- and post-stages of stent implantation. So, we suspect that the pulmonary regurgitation remaining after right ventricle outlet tract(RVOT) dilatation surgery is correlated with the increase in CSAI of RPA.

Management for the Newly-Onset Aneurysmal Dilation of the Distal Aorta after an Endovascular Stent Graft Procedure for the Patient with Acute Aortic Dissection Type IIIb (급성 하행대동맥 박리증에서 스텐트-그라프트 삽입 후 새로이 발생한 원위부 대동맥류에 대한 인조혈관 대치술 치험 1예)

  • 이길수;방정희;조광조;성시찬;우종수
    • Journal of Chest Surgery
    • /
    • v.36 no.6
    • /
    • pp.427-430
    • /
    • 2003
  • The surgical managements for the complicated aortic disease is still one of most challenging fields for the cardiac surgeons. The endovascular stent graft procedure has been tried recently to avoid serious complications caused by traditional graft replacement technique. However, indications for the procedures or management methods for the complications have not been clearly elucidated so far. We report a case of successful management for the newly-onset aneurysmal dilation of the distal aorta after an endovascular stent graft procedure in a patient with acute aortic dissection type IIIB.

Nationwide Mortality Data after Flow-Diverting Stent Implantation in Korea

  • Kim, Tackeun;Kwon, O-Ki;Lee, Heeyoung;Cho, Min Jai;Jeong, Hyun Jean;Ban, Seung Pil
    • Journal of Korean Neurosurgical Society
    • /
    • v.61 no.2
    • /
    • pp.219-223
    • /
    • 2018
  • Objective : To investigate nationwide statistics on flow-diverting stent usage for cerebral aneurysm treatment and related mortality data. Methods : We requested data extraction from the National Health Insurance Service claims database using electronic data interchange codes (J3207064, J3207073). Patient and hospital information as well as death statistics were collected from the database. Results : A total of 169 procedures were performed using flow-diverting stents for cerebral aneurysm treatment from November 2014 to December 2016 in Korea. The majority of primary diagnosis was unruptured intracranial aneurysm. During the study period, nine subjects died, including one patient initially diagnosed with subarachnoid hemorrhage. The crude mortality rate was 5.3%. Five patients died within one month after the procedure; therefore, the estimated periprocedural mortality rate was $3.0{\pm}1.3%$. The mortality rate as of the last day of 2016 was $6.3{\pm}2.1%$. Conclusion : In a 171 person-year follow-up in a Korean series, nine deaths occurred after flow-diverting stent treatment. The crude mortality rate in Korea (5.3%) was higher than that reported in a previous meta-analysis (3.8%).

Endovascular Graft-Stent Placement for Treatment of Traumatic Carotid Cavernous Fistulas

  • Choi, Beom-Jin;Lee, Tae-Hong;Kim, Chang-Won;Choi, Chang-Hwa
    • Journal of Korean Neurosurgical Society
    • /
    • v.46 no.6
    • /
    • pp.572-576
    • /
    • 2009
  • Detachable balloon-based endovascular fistula occlusion is a widely accepted treatment for traumatic carotid cavernous fistulas (CCF). However, more recently coils have been used to obliterate the lesion, especially in case detachable balloon is not available. We failed balloon-assisted coil embolization for CCF because of large fistulas and herniation of coil loops into the parent artery. The authors describe our experiences of balloon-expandable graft-stents to treat CCF, and place emphasis on arterial wall reconstruction. Three traumatic CCF patients were treated using a graft-stent with/without coils, and underwent angiographic follow-up to evaluate the patency of the internal carotid artery (ICA). In all cases, symptoms related to CCF regressed after stent deployment and did not recur during follow-up. Follow-up angiography revealed good patency of the ICA in all patients. Graft-stents should be considered as an alternative means of treating CCF and preserving the parent artery by arterial wall reconstruction especially in patients with a fistula that cannot be successfully occluded with detachable balloons or coils.