• 제목/요약/키워드: Xenon Gas

검색결과 65건 처리시간 0.023초

Effects of Neon Plasma Emission on Optical Properties of Phosphor Layers in Surface-Type Alternate Current Plasma Display Panel

  • Jang, Sang-Hun;Cho, Ki-Duck;Tae, Heung-Sik;Park, Lee-Soon
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2000년도 제1회 학술대회 논문집
    • /
    • pp.171-174
    • /
    • 2000
  • This study uses neon and xenon gas mixture discharges to determine the effects of the neon plasma emission on the characteristics of visible emission from the stimulation of the red, green, blue(RGB) phosphor layers in a surface-type alternate current plasma display panel(AC PDP). With a mixture of less than 2% xenon to neon, it is found that the luminance changes in the visible emission of the phosphor layers are similar to those of the neon plasma emission. In the range of xenon mix ratio from 2 to 5%, the luminance of the red, green, blue(RGB) phosphor layers decreases with a decrease in the neon plasma emission intensity. However, with a mixture of above 5% xenon to neon, the luminance of the red, green, blue(RGB) phosphor layers increases regardless of a decrease in the neon plasma emission intensity. Furthermore, the color purity of the red, green, blue(RGB) phosphor layers improve as the neon plasma emission intensity decreases. Accordingly, it is concluded that the optical properties of the phosphor layers, including color purity and luminance, depend on the neon plasma discharge emission as well as the visible emission from the stimulation of the phosphor layers.

  • PDF

제논 램프 구동용 트리거 및 지머 통합 회로 (Integrated High Voltage Trigger and Simmer power supply for Xenon Lamp)

  • 가재예;조찬기;송승호;정우철;박현일;류홍제
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2018년도 전력전자학술대회
    • /
    • pp.51-53
    • /
    • 2018
  • This paper describes the design and implementation of a circuit consisting of a simmer power supply unit and a series trigger unit that can be applicable to xenon lamp driving. An LCC resonant converter based on the continuous conduction mode (CCM) is applied to the simmer circuit and by using the current output control it is possible to maintain the ionization of the lamp which has the negative resistance load characteristic. At the same time, in order to generate a high voltage, a series trigger circuit which has a number of capacitors and diodes is designed. The generated high trigger output voltage could ionize the xenon gas. This paper explains the configuration and features of the integrated circuit system, and verifies the proposed design and stable operation of the xenon lamp. The experimental and simulation results show the not only rationality but also stability of the proposed circuit.

  • PDF

Measurement of the excited Xe atoms density of matastable state$(1S_5)$ under various binary gas mixtures(Ne-Xe) by Laser Absorption Spectroscopy.

  • Lee, Jun-Ho;OH, P.Y.;Moon, M.W.;Ko, B.D.;Jeong, J.M.;Lee, H.J.;Choi, E.H.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2005년도 International Meeting on Information Displayvol.II
    • /
    • pp.1218-1220
    • /
    • 2005
  • We have developed laser absorption spectroscopy system for the measurement of excited Xe atoms in micro-discharged AC-PDP plasma. In this study, we have measured the absorption signals for the $1S_5$ xenon metastable state in the PDP cell with the various gas mixtures of Ne-Xe(1%), Ne-Xe(4%) and Ne-Xe(10%) under fixed gas pressure of 350 Torr and the eletrode gap distance of 50um. It is found that the maximum excited xenon densities are $1.2^{\ast}10^{12}\;cm^{-3}$, $1.8^{\ast}10^{12}\;cm^{-3}$ and $2.7^{\ast}10^{12}cm^{-3}$ for gas mixtures of Ne-Xe(1%), Ne-Xe(4%) and Ne-Xe(10%) respectively, in this experiment.

  • PDF

우주추진용 홀방식의 전기추력기를 위한 제논연료공급장치 개발 (Development of Xenon Feed System for a Hall-Effect Thruster to Space-propulsion Applications)

  • 김연호;강성민;정연황;선종호;위정현;윤호성;최원호;이종섭;서미희
    • 한국항공우주학회지
    • /
    • 제39권1호
    • /
    • pp.84-89
    • /
    • 2011
  • 소형인공위성의 우주추진체로 사용될 홀방식 전기추력기의 서브시스템으로 제논연료공급장치가 개발되었다. 제논연료공급장치는 연료저장탱크에서 추력기의 양극과 음극에 낮은 압력으로 연료를 공급하게 된다. 추력기는 양극과 음극에서 독립적으로 정밀한 연료의 유량제어를 요구하고 있다. 연료의 유량은 양극과 음극에 각각 위치한 오리피스와 차단밸브를 통해 축압탱크의 압력을 변경함으로서 조절된다. 본 논문은 제논연료공급장치의 부품선정을 포함한 설계와 성능검증 및 기능시험에 대한 내용을 다루고 있다.

An ionization Chamber for a Steel Sheet Thickness Measurement

  • Kim, Han-Soo;Park, Se-Hwa;Kim, Yong-Kyun;Ha, Jang-Ho;Cho, Seung-Yeon
    • Journal of Radiation Protection and Research
    • /
    • 제31권3호
    • /
    • pp.149-153
    • /
    • 2006
  • An ionization chamber is still widely used in many fields by virtue of its' simple operational characteristics and the possibility of its' various shapes. A parallel type of an ionization chamber for a steel sheet thickness measurement was designed and fabricated. High pure xenon gas, which was pressurized up to 6 atm, was chosen as a filling gas to increase the current response and sensitivity for a radiation. A high pressure gas system was also constructed. The active volume and the incident window size of the fabricated ionization chamber were $30\;cm^3\;and\;12\;cm^2$, respectively. Preliminary tests with a 25 mCi $^{241}Am$ gamma-ray source and evaluation tests in a standard X-ray field were performed. The optimal operation voltage was set from the results of the collection efficiency calculation by using an experimental two-voltage method. Linearity for a variation of the steel sheet thickness, which is the most important factor for an application during a steel sheet thickness measurement, was 0.989 in this study.

크세논-129 핵자기 공명 분광법을 이용한 불균일계 촉매의 연구 (Xenon-129 NMR Method for the Study of Heterogeneous Catalysts)

  • 유룡
    • 공업화학
    • /
    • 제2권1호
    • /
    • pp.1-11
    • /
    • 1991
  • 1980년대 발전된 크세논-129 핵자기 공명분광법은 제올라이트나 활성탄 또는 알루미나와 같은 다공성 물질에 크세논 기체를 흡착시킨 후에 기 기체중에 존재하는 천연동위원소 $^{129}Xe$의 핵자기 공명신호의 화학적이동(chemical shift)이나 선폭(linewidth)으로 부터 그 물질의 물리화학적 특성을 분석하는 방법이다. 현재까지 이 방법은 주로 제올라이트 촉매를 제조하거나 반응시키는 경우에 있어서 담지된 금속 물질의 위치와 화학변화 및 담체 자체의 성질변화 등을 감지하는데 있어서 탁월한 것으로 알려져 있으며, 최근에는 이 방법이 활성탄과 실리카, 알루미나와 같은 비정형 물질에도 효과적으로 적용될 수 있다는 것이 발표되었다. 여기서는, 이 크세논-129 핵자기 공명 분광법의 원리와 실험방법 및 불균일계 촉매연구 분야에서 이 방법의 이용에 대한 최근의 연구결과들을 요약하여 소개한다.

  • PDF

LCC 컨버터 기반의 제논 플래시 램프 구동장치를 위한 시머회로 설계 (Design of a Simmer Circuit for Xenon Flash Lamp Driver Based on a LCC Converter)

  • 송승호;조찬기;박수미;박현일;배정수;장성록;류홍제
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2017년도 전력전자학술대회
    • /
    • pp.231-232
    • /
    • 2017
  • This paper describes the design and implementation of a 2.5kW (500V, 5A) simmer circuit that maintains the ionization of xenon gas inside the lamp. The design is based on a LCC resonant converter in continuous conduction mode (CCM) with above resonant frequency to take advantage of high power density from using parasitic elements such as the leakage inductance in a power transformer. In addition, since the converter has current source output characteristics, it is suitable for maintaining ionization of the lamp having the negative resistance load characteristic. To verify this converter design, PSpice modeling was performed. Finally, the developed simmer circuit is verified by a resistive load of rated performance and the Ionization maintenance operation of the xenon flash lamp.

  • PDF

Measurement of excited Xe($1s_4$) and Xe($1S_5$) atoms by laser absorption spectroscopy in coplanar AC-PDP

  • Oh, P.Y.;Lee, J.H.;Moon, H.S.;Hong, J.W.;Jeon, W.;Cho, G.S.;Choi, E.H.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2004년도 Asia Display / IMID 04
    • /
    • pp.515-517
    • /
    • 2004
  • The laser absorption spectroscopy has been used for measuresurement of the xenon atoms in the resonant $1S_4$ and metastable $1S_5$ states in coplanar AC PDP. For the purpose of improving VUV luminous efficiency and optimization of PDP cells, it is important to study behavior of excited Xe atoms in a micro-discharge cell of a coplanar AC-PDP. We measured the xenon excited density of $1S_5$ and $1S_4$ state under mixture gas of Ne-Xe(10%) with gas pressure of 350 Torr and sustaining gap distance of 150 um.

  • PDF

A gas display device with electron emitter

  • Son, Seung-Hyun;Nam, Mun-Ho;Kim, Jung-Min;Cho, Sung-Hee;Jang, Sang-Hun;Kim, Gi-Young;Han, In-Su;Kim, Dae-Hyun;Cho, Young-Mi;Kim, Chang-Wook;Park, Hyoung-Bin
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2007년도 7th International Meeting on Information Display 제7권2호
    • /
    • pp.1253-1256
    • /
    • 2007
  • A display device combining plasma display panel (PDP) and field emission display (FED) is proposed to achieve high luminous efficiency. The device can avoid the main energy loss channels of both PDP (ion loss) and FED (low CL efficiency). $2{\sim}6$”-diagonal test panels with carbon nano-tube (CNT) electron emitter and Xenon ambient gas showed the luminous efficiency of 4.14lm/W and brightness of $263cd/m^2$ at 35V (1kHz, 1% duty), indicating that it is a good candidate for the low voltage driven, highly efficient next generation display.

  • PDF