• Title/Summary/Keyword: Xe ratio

Search Result 76, Processing Time 0.024 seconds

Influence of Sustain Voltage on Wall Charge and Wall Voltage Characteristics in AC-PDPs

  • Kim, T.Y.;Cho, T.S.;Kim, S.S.;Cho, D.S.;Kim, J.G.;Ahn, J.C.;Jung, Y.H.;Lim, J.Y.;Jung, J.M.;Ko, J.J.;Kim, D.I.;Lee, C.W.;Seo, Y.;Cho, G.S.;Choi, E.H.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2000.01a
    • /
    • pp.119-120
    • /
    • 2000
  • Influences of sustain voltage on wall charges and wall voltages are experimentally investigated in surface AC plasma display panels(AC-PDPs), in which electrode gap and width are $80\;{\mu}m$ and $270\;{\mu}m$, respectively. The filling gas is Ne-Xe gas mixture, and total pressures 300 Torr. Also it is found that the more amount of Xe mixing ratio makes the less wall charge and voltage for sustain voltage ranged from 140 V to 222 V. The response time has been delayed by adding a small amount of Xe to Ne in comparison with that without Xe. It is also found that the wall charge and voltage are reduced by adding a small amount of Xe to Ne in comparison with those without Xe.

  • PDF

Micro-discharged plasma density, electron temperature and excited xenon density for enhancement of vacuum ultraviolet luminous efficiency in alternating current plasma display panel

  • Choi, Eun-Ha;Oh, Phil-Yong;Seo, Yoon-Ho;Cho, Guang-Sup;Uhm, Han-S
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07a
    • /
    • pp.161-166
    • /
    • 2005
  • The plasma ion density in AC-PDP has shown to be increased from $5.6{\times}10^{11}cm^{-3}$ to $9.0{\times}10^{11)cm^{-3}$ as the Xe mixture ratio to neon increase from 1 % to 10 %, respectively, at fixed pressure of 400 Torr, by using the micro-Langmuir probe. It is noted that the plasma ion density is density increases as the gas pressure increases in this experiment. The electron temperature decreases from 2.3 to 1.2 eV as the Xe mole fraction increases from 1 % to 10 % at fixed pressure of 400 Torr, which is measured by the micro Langmuir probe and high-speed ICCD camera in this experiment. It is noted that the electron temperature decreases as the gas pressure increases from 150 to 400 Torr in this experiment. It is also observed that the exited Xe atom density and the plasma ion density are in strong correlation sharp between each other in this experiment. It is noted that $5.2{\times}10^{12}cm^{-3}$ in the $1s_5$ metastable state and $1.2{\times}10^{12}cm^{-3}$ in the $1s_4$ resonance state for the PDP cell with gap of 50 um distances under the fixed gas pressure of 400 Torr and Xe content ratio of 10 %.

  • PDF

Electrooptic Characteristics of Xe-type Flat Fluorescent Lamps Studied by a Q-V Lissajous Method (Q-V Lissajous 방법을 이용한 Xe형 평판형 형광램프의 전기광학 특성 평가)

  • Kim, Young-Youb;Yu, Mi-Yeon;Ko, Jae-Hyeon;Ryu, Si-Hong;Lee, Seong-Eui
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.165-168
    • /
    • 2007
  • Electrooptic characteristics of Xe-type flat fluorescent lamps (FFL) have been investigated by using a Q-V Lissajous method. It was found that the luminance of the Mgo-coated FFL became more than doubled compared to normal FFLs operated at the same driving voltage, indicating the possibility of the efficacy improvement in the MgO-coated FFLs. Change in the driving condition, in particular, the duty ratio had effects on the electrooptic properties, and it was found that the duty ratio of 50% was the optimum condition from the viewpoints of the efficacy and the lamp voltage.

  • PDF

Analysis of Electron Transport Coefficients in Binary Mixtures of TEOS Gas with Kr, Xe, He and Ne Gases for Using in Plasma Assisted Thin-film Deposition

  • Tuan, Do Anh
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.2
    • /
    • pp.455-462
    • /
    • 2016
  • The electron transport coefficients in not only pure atoms and molecules but also in the binary gas mixtures are necessary, especially on understanding quantitatively plasma phenomena and ionized gases. Electron transport coefficients (electron drift velocity, density-normalized longitudinal diffusion coefficient, and density-normalized effective ionization coefficient) in binary mixtures of TEOS gas with buffer gases such as Kr, Xe, He, and Ne gases, therefore, was analyzed and calculated by a two-term approximation of the Boltzmann equation in the E/N range (ratio of the electric field E to the neutral number density N) of 0.1 - 1000 Td (1 Td = 10−17 V.cm2). These binary gas mixtures can be considered to use as the silicon sources in many industrial applications depending on mixture ratio and particular application of gas, especially on plasma assisted thin-film deposition.

The Study on Optical Properties of Xenon ICP Lamp Dependently on Gas Pressure and Input Power (ICP 제논 램프의 가스 압력과 공급 전력에 따른 광학적 특성연구)

  • Choi, Gi-Seung;Lee, Seong-Jin;Lee, Jung-Chan;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1659-1660
    • /
    • 2006
  • After end of the 20th environmental problem was became issue. So about mercury free lighting sources are being studied very much. In this paper, a mercury and electrode free bulb was designed. in this bulb was injected mixed of Xe, Ne and Kr Gases. and then the bulb was discharged by 13.56MHz RF Power after spectrum, color coordinates and brightness were measured by spectrum meter CS-1000. Measured results were compared and analyzed, also analysis was able to do a characteristic of a gas defensive fight in proportion to a mixing ratio. Therefore the most of high brightness which was 4500cd/m2 was gained in 1:1 ratio of Xe:Ne at 60W input power.

  • PDF

Influence of gas mixture ratio on the secondary electron emission coefficient (${\gamma}$) of MgO single crystals and MgO protective layer in surface discharge AC-PDPs

  • Lim, J.Y.;Jung, J.M.;Kim, Y.G.;Ahn, J.C.;Cho, T.S.;Cho, D.S.;Kim, J.G.;Kim, T.Y.;Kim, S.S.;Jung, M.W.;Choi, S.H.;Ko, J.J.;Kim, D.I.;Lee, C.W.;Seo, Y.;Cho, G.S.;Kang, S.O.;Choi, E.H.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2000.01a
    • /
    • pp.117-118
    • /
    • 2000
  • The secondary electron emission coefficient ${\gamma}$ of MgO single crystals according to the gas mixture ratio of Xe to Ne have been investigated by ${\gamma}-focused$ ion beam system. It is found that the MgO single crystals of (111) crystallinity has the highest ${\gamma}$ from 0.09(0.03) up to 0.16(0.04), while from 0.07(0.02) to 0.15(0.03) for (200) and from 0.06(0.01) to 0.13(0.02) for (220) crystallinity for operating Ne (Xe) ions ranging from 50eV to 200eV throughout this experiment. And it is found that the ${\gamma}$ ranged from 0.03 up to 0.06 for Ne-Xe mixtures are much smaller than those of 0.09 up to 0.16 for pure Ne ions under accelerating voltage ranged from 50V to 200V.

  • PDF

The electrical and optical properties of Xe plasma in flat lamp (평판형 광원에서 제논(Xe) 플라즈마의 전기적 광학적 특성 연구)

  • Pack, Gwang-Hyeon;Yang, Jong-Kyung;Lee, Jong-Chan;Chio, Yong-Sung;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.05b
    • /
    • pp.60-64
    • /
    • 2005
  • Discharge of the flat lamp lighting source research are requested very much. For improving brightness, life time, efficiency of flat lamp, plasma diagnosis of the flat lamp lighting source to understand property of lighting source is very important, distance of discharge electrode is 5.5mm and width is 16.5mm, we measured electron temperature and electron density measured with single langmuir probe in flat lamp, we tested the discharge from 100 Torr to 300 Torr pressure, the Pulse is rectangular pulse with frequency 20kHz and Duty ratio 20%. Resultly, electron temperature decreases and electron density increase as increase the gas pressure and electron temperature decreases and electron density increase as increase the voltage.

  • PDF

Xe Plasma Property with Flat Lamp by Langmuir Probe (단일탐침법을 사용한 평판형 광원의 제논 (Xe) 플라즈마 특성 연구)

  • Pack Gwang-Hyeon;Lee Jong-Chan;Hwang Myung-Keun;Choi Yong-Sung;Park Dae-Hee
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.1
    • /
    • pp.50-54
    • /
    • 2006
  • The study on discharge of the flat lamp lighting source has been requested increasingly. To improve the brightness, life time and efficiency of flat lamp, the plasma diagnosis of flat lamp lighting source is very important. When a distance of discharge electrode is 5.5mm and width is 16.5mm, we measured electron temperature and electron density with single Langmuir probe in flat lamp. Pressure conditions to test the plasma discharge from 100 Torr to 300 Torr. The power supply was PDS-4000 with frequency 20kHz and duty ratio $20\%.$ Form these experimental results, electron temperature was decreased according to increase the gas pressure and the voltage while electron density was increased.