• Title/Summary/Keyword: XY Stage

Search Result 61, Processing Time 0.024 seconds

A study on response analysis of 6-DOF pneumatic vibration isolation table loaded by transient movements of carriage on it (상판 위 질량의 순간적인 움직임에 의해 가진되는 6-자유도 공압제진대의 진동 응답에 대한 연구)

  • Sun, Jong-Oh;Shin, Yun-Ho;Kim, Kwang-Joon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.97-102
    • /
    • 2007
  • As environmental vibration requirements on precision equipments get more stringent, use of pneumatic vibration isolators becomes more crucial and, hence, their dynamic performance needs to be further improved. Dynamic behavior of those pneumatic vibration isolation tables is very important to both manufacturer and customer as performance specifications. Together with conventional transmissibility, transient response characteristics are another critical performance index especially when movements of components, e.g., x-y tables, of the precision equipments are very dynamic. In this paper, analysis on transient response of a pneumatic vibration isolation table loaded by a mass moving on it is presented. This is a conventional dynamics problem on a rigid body with 6 degree of freedom and a mass with another degree of freedom. How to obtain transient responses of the isolation table is described when the movements of the mass are prescribed relative to the table.

  • PDF

RECTIFICATION OF PURE TRANSLATION 2D CAMERA ARRAY

  • Ota, Makoto;Fukushima, Norishige;Yendo, Tomohiro;Tanimoto, Masayuki;Fujii, Toshiaki
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2009.01a
    • /
    • pp.659-663
    • /
    • 2009
  • In this paper, we propose a rectification method that can convert ray space data obtained by controlled camera array to ideal data. Here, Ideal data is obtained by getting longitudinal and transversal epipolar line between cameras vertical and horizontal. However it is actually difficult to arrange cameras strictly because we arrange cameras by hand. As conventional method, we have use camera-calibration method. But if we use this method there are some errors on the output image. When we generate arbitrary viewpoint images this error is critical problem. We focus attention on ideal trajectory of characteristic point. And to minimize the error directly we parallelize the real one. And we showed usefulness of proposed technique. Then using the proposed technique, we were successful reducing the error to less than 0.5 pixels.

  • PDF

Fabrication of waveguide using UV Ar-ion laser direct writing (Laser Direct Writing 방법을 이용한 광도파로 제작)

  • Kang H. S.;Suh J.;Lee J. H.;Kim J. O.
    • Laser Solutions
    • /
    • v.8 no.1
    • /
    • pp.9-18
    • /
    • 2005
  • The laser direct writing method using a UV Argon-ion laser is studied for fabrication of waveguide. The laser direct writing system is constructed with a vision camera, a xy-stage, a motion controller and the delivery components of a laser beam. The UV Argon-ion laser has wavelength range of $333.6\~363.8$ nm. A photo-active UV curable polymer for a planar light-wave circuit(PLC) of single mode is used. This polymer is irradiated by Argon-ion laser and developed by a solvent after a post-baking. The optimum laser direct writing condition is obtained experimentally by changing various process parameters such as laser power, writing speed and focal length. The propagation and coupling loss of a optical waveguide was measured as 1dB/cm and 0.6dB/cm, respectively. Also, the minimum width of waveguide of $100{\mu}m$(ZPLW-207) is obtained. Finally, the waveguides of line, bend and branch type are successfully fabricated.

  • PDF

Manufacturing of Ag Nano-particle Ink-jet Printer and the Application into Metal Interconnection Process of Si Solar Cells (Si 태양전지 금속배선 공정을 위한 나노 Ag 잉크젯 프린터 제작 및 응용)

  • Lee, Jung-Tack;Choi, Jae-Ho;Kim, Ki-Wan;Shin, Myoung-Sun;Kim, Keun-Joo
    • Journal of the Semiconductor & Display Technology
    • /
    • v.10 no.2
    • /
    • pp.73-81
    • /
    • 2011
  • We manufactured the inkjet printing system for the application into the nano Ag finger line interconnection process in Si solar cells. The home-made inkjet printer consists of motion part for XY motion stage with optical table, head part, power and control part in the rack box with pump, and ink supply part for the connection of pump-tube-sub ink tanknozzle. The ink jet printing system has been used to conduct the interconnection process of finger lines on Si solar cell. The nano ink includes the 50 nm-diameter. Ag nano particles and the viscosity is 14.4 cP at $22^{\circ}C$. After processing of inkjet printing on the finger lines of Si solar cell, the nano particles were measured by scanning electron microscope. After the heat treatment at $850^{\circ}C$, the finger lines showed the smooth surface morphology without micropores.

A Study on Response Analysis of 6-DOF Pneumatic Vibration Isolation Table Loaded by Transient Movements of Carriage on It (상판 위 질량의 순간적인 움직임에 의해 가진되는 6-자유도 공압제진대의 진동 응답에 대한 연구)

  • Sun, Jong-Oh;Shin, Yun-Ho;Kim, Kwang-Joon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.17 no.6 s.123
    • /
    • pp.515-523
    • /
    • 2007
  • As environmental vibration requirements on precision equipments get more stringent, use of pneumatic vibration isolators becomes more crucial and, hence, their dynamic performance needs to be further improved. Dynamic behavior of those pneumatic vibration Isolation tables is very important to both manufacturer and customer as performance specifications. Together with conventional transmissibility, transient response characteristics are another critical performance index especially when movements of components, e.g., x-y tables, of the precision equipments are very dynamic. In this paper, analysis on transient response of a pneumatic vibration isolation table loaded by a mass moving on it is presented. This is a conventional dynamics problem on a rigid body with 6 degree of freedom and a mass with another degree of freedom. How to obtain transient responses of the isolation table is described when the movements of the mass are prescribed relative to the table.

Design and Lithographic Fabrication of Elliptical Zone Plate Array with High Fill Factor

  • Anh, Nguyen Nu Hoang;Rhee, Hyug-Gyo;Ghim, Young-Sik
    • Current Optics and Photonics
    • /
    • v.5 no.1
    • /
    • pp.8-15
    • /
    • 2021
  • An elliptical zone plate (EZP) array is important in off-axis optical systems because it provides two advantages. First, the residual beam and the main source are not focused in the same direction and second, the light from the observation plane is not reflected back towards the beam source. However, the fill factor of the previous EZP array was about 76% which was a little low. Hence, this EZP array could not collect the maximum amount of illumination light, which affected the overall optical performance of the lens array. In this study, we propose a new EZP array design with a 97.5% fill factor used in off-axis imaging system for enhancement of brightness and contrast. Then, direct laser lithography was used to fabricate the high fill factor EZP array by moving the XY linear stage of the system in a zigzag motion. The imaging properties of the proposed EZP array were experimentally verified at the focal plane and compared with the previous model.

A case of Sotos syndrome presented with end-stage renal disease due to the posterior urethral valve

  • Cho, Won Im;Ko, Jung Min;Kang, Hee Gyung;Ha, Il-Soo;Cheong, Hae Il
    • Journal of Genetic Medicine
    • /
    • v.11 no.2
    • /
    • pp.74-78
    • /
    • 2014
  • Sotos syndrome (SS, OMIM 117550) is characterized by prenatal and postnatal overgrowth with multiple congenital anomalies. However, there have been few cases of growth retardation caused by renal failure from infancy. We report a case of dysplasia of the bilateral kidneys with renal failure and poor postnatal growth. A 2-month-old boy visited the emergency room owing to poor oral intake and abdominal distension. He was born at the gestational age of 38 weeks with a birth weight of 4,180 g. After birth, he had feeding difficulty and abdominal distension. Upon physical examination, his height and weight were in less than the 3rd percentile, while his head circumference was in the 50th percentile on the growth curve. He also showed a broad and protruding forehead and high hairline. Blood laboratory tests showed severe azotemia; emergent hemodialysis was needed. Abdominal ultrasonography revealed bilateral renal dysplasia with multiple cysts and diffuse bladder wall thickening. A posterior urethral valve was suggested based on vesicoureterography and abdominal magnetic resonance findings. Results of a colon study to rule out congenital megacolon did not reveal any specific findings. The conventional karyotype of the patient was 46, XY. Array comparative genomic hybridization study revealed a chromosome 5q35 microdeletion including the NSD1 gene, based on which SS was diagnosed. We describe a case of SS presenting with end stage renal disease due to posterior urethral valve. The typical somatic overgrowth of SS in the postnatal period was not observed due to chronic renal failure that started in the neonatal period.

Clinical Microscopy: Performance, Maintenance and Laser Safety (임상에서의 현미경: 작동, 유지보수 및 레이저 안전)

  • Lee, Tae Bok
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.51 no.2
    • /
    • pp.125-133
    • /
    • 2019
  • A microscope is the fundamental research and diagnostic apparatus for clinical investigation of signaling transduction, morphological changes and physiological tracking of cells and intact tissues from patients in the biomedical laboratory science. Proper use, care and maintenance of microscope with comprehensive understanding in mechanism are fully requested for reliable image data and accurate interpretation for diagnosis in the clinical laboratory. The standard operating procedure (SOP) for light microscopes includes performance procedure, brief information of all mechanical parts of microscopes with systematic troubleshooting mechanism depending on the laboratory capacity. Maintenance program encompasses cleaning objective, ocular lenses and inner optics; replacement and calibration of light source; XY sample stage management; point spread function (PSF) measurement for confocal laser scanning microscope (CLSM); quality control (QC) program in fluorescent microscopy; and systematic troubleshooting. Laser safety is one of the concern for medical technologists engaged in CLSM laboratory. Laser safety guideline based on the laser classification and risk level, and advisory lab wear for CLSM users are also expatiated in this overview. Since acquired image data presents a wide range of information at the moment of acquisition, well-maintained microscopes with proper microscopic maintenance program are impulsive for its interpretation and diagnosis in the clinical laboratory.

Treatment Results of Ovarian Dysgerminoma (난소 미분화세포종의 치료 결과)

  • Chung, Eun-Ji;Suh, Chang-Ok;Seong, Jin-Sil;Keum, Ki-Chang;Kim, Gwi-Eon
    • Radiation Oncology Journal
    • /
    • v.14 no.3
    • /
    • pp.221-228
    • /
    • 1996
  • Purpose : We tried to evaluate the clinical characteristics, the treatment methods, the results of treatments, and the Patterns of failure in ovarian dysgerminoma retrospectively According to the results we would like to suggest the proper management guideline of stage la ovarian dysgerminoma patients who want to maintain fertility. Materials and Methods : Between 1975 and 1990, 34 patients with ovarian dysgerminoma were treated at the Yonsei University Hospital. The case records of these patients have been reviewed for presenting symptoms, treatment methods, local control and survival following treatment. Excluded from analysis were five patients with mixed ovarian germ cell tumors and gonadoblastomas (46,XY) Treatment results of the twenty nine patients were analysed by each treatment modality. Twenty one patients were treated with surgery and postoperative adjuvant radiotherapy (group 2). The other eight patients were treated with operation alone (group 2). The median age of twenty-nine patients was 23 years with a range of 8 to 39 years. Presenting symptoms were abdominal mass (20) pelvic discomfort or pain (5) et al. Radiotherapy was performed by 10MV LINAC or Co-60 teletherapy unit. The total radiation dose of the whole abdomen was 20-25 Gy/3weeks, 1-1.5 Gy/fraction with a boost to the whole pelvis 10-15 Gy/l-2weeks 1.8-2.0 Gy/fraction. Advanced stage disease (stage II or stage III) patients received prophylactic mediastinal and supraclavicular irradiation to a dose of 16-26 Gy. Median duration of follow-up of living patients was 80 months (range 13-201 months). Results : All of the twenty one patients of group 1 were alive without disease ($100\%$). Among the eight patients who were not treated with radiotherapy (group 2), six patients developed local recurrence. Four Patients referred with recurrent disease were treated with salvage radiotherapy. Three of four patients were salvaged and one Patient who had recurrent intra-abdominal disease died of progressed carcinomatosis at 11 months after salvage radiotherapy. The other two patients with recurrence were salvaged with chemotherapy (1 patient) or re-operation (1 Patient). Twenty eight patients remained alive without disease at last follow up, so the 5 year local control rate and 5 year overall survival rate for all groups were $96.6\%$ (28/29), respectively. Among thirteen patients with stage la unilateral tumors seven patients were treated with postoperative radiotherapy and the other six patients were treated with unilateral salpingo-oophorectomy alone. Five patients who did not received radiotherapy developed local failure but all of the recurrent ovarian dysgerminomas were salvaged with radiotherapy, chemotherapy or re-operation. So all the 13 patients with stage la ovarian dysgerminoma were free of disease from 20-201 months (median 80 months). Conclusion : The authors consider external irradiation to be an effective treatment as a complement to surgery in ovarian dysgerminoma. For those patients with disease presenting in stage la tumors who wish to maintain fertility, unilateral salpingo-oophorectomy alone may be curative and spare ovarian function considering excellent salvage rate of recurrent ovarian dysgerminoma in present study.

  • PDF

Chromosomal Analysis of Hanwoo Embryos by In Vitro Culture Condition (한우 체외 수정란의 체외 배양 조건에 따른 염색체 분석)

  • Choi, S.H.;Cho, S.R.;Han, M.H.;Kim, H.J.;Choe, C.Y.;Son, D.S.;Chung, Y.G.;Kim, S.K.;Sohn, S.H.
    • Journal of Embryo Transfer
    • /
    • v.22 no.2
    • /
    • pp.137-141
    • /
    • 2007
  • Antioxidants were well known to be essential supplements in the complex media and serve as a reservoir of oxygen. In this study, Hanwoo COCs (cumulus oocytes complexes) were matured and developed in L-cysteine-TCM199 and analyzed metaphase chromosome. Maturation rate of Hanwoo COCs were 73.4%, 94.6% in 0.1% PVA, 0.1 mM L-cysteine, respectively and showed significantly different between the treatments (p<0.05). Blastocyst formation were revealed 20.3%, 10.0% in 5% FBS+TCM199, 0.1 mM L-cysteine+1% BSA, respectively. There were no significant difference among treatment groups. Metaphase chromosome were showed 18.3%, 12.0% in 5% FBS-TCM199, 0.1 mM L-cysteine, respectively and analyzable chromosome were 6.1%, 4.0% and had no differences between the treated groups. In the case of in vitro developmental stages, metaphase chromosome were showed 18.3%, 12.0% in $4{\sim}16$ cells stage, 43.1%, 13.0% in morulae stage and 94.8%, 100.0% in blastocyst stage. These results suggested L-cysteine has beneficial role for in virto maturation and development in Hanwoo COCs.