3상 전력케이블 크로스본딩 접속에서 부분방전 펄스 전파 특성 고찰 (Considerations on the Propagation of Partial Discharge Pulse in 3-Phase Power Cable Systems including Cross-Bonding Joints)

  • 김정태;김동욱;김지홍
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.1606-1607
    • /
    • 2011
  • In this study, the propagation characteristics of partial discharge(PD) pulses in the 3-phase cable systems including crossbonding joints were discussed. For the purpose, experiments for 22.9kV CNCV cables were performed using simulated PD pulses, and on-site partial discharge measurements were carried out for the 345kV XLPE cable system.

  • PDF

초고압 전력케이블 절연체의 Flow Pattern에 따른 절연성능 고찰 (Dielectric Strength According to Flow Pattern in EHV Power Cable Insulation)

  • 이승엽;김영호;이상진;김동욱;최명규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1539-1541
    • /
    • 2000
  • Insulation layers in XLPE power cables may have some patterns generated in the manufacturing process. They are called 'flow patterns' and show flow history of molten polyethylene between inner and outer semiconducting layers. Flow patterns are even seen with naked human eyes and suspected to be inhomogeniety of insulation, weakening insulation performance. Investigated in this paper is electrical treeing resistance and ac breakdown strength according to flow patterns. Experiments of electrical treeing and ac breakdown strength by means of ramp tests were conducted using newly developed electrode system with point-to-plane structure and sphere-to-sphere structure, respectively. All results were analyzed with the application of statistics, showing little differences.

  • PDF

XLPE 절연케이블의 열화진단 정확도 향상을 위한 VLF tanδ 판정기준 개선 (An Amendment of the VLF tanδ Criteria to Improve the Diagnostic Accuracy of the XLPE-insulated Power Cables)

  • 이재봉;정연하
    • 전기학회논문지
    • /
    • 제59권9호
    • /
    • pp.1644-1651
    • /
    • 2010
  • VLF $tan{\delta}$ diagnosis technology is introduced in IEEE Std 400 and proposed as evaluation criterion in an effective way of detecting water tree which mainly causes the failure of XLPE insulated cables. In order to inspect the accuracy of the VLF $tan{\delta}$ method for XLPE insulated power cables in Korean distribution system, diagnosis for 41 cables which were being serviced in the fields has been carried out and they were removed for AC breakdown voltage test after. Regarding the 41 cables, it was hard to confirm any relation between the VLF $tan{\delta}$ values and AC breakdown voltages and also water tree in the insulation was not detected. However, the other cables were failed several days after the diagnosis of the 41 cables. Water trees were found and their VLF $tan{\delta}$ values were also much higher than the criterion of IEEE standard. It has been ascertained that we need to change the IEEE criteria in order to improve the accuracy of detecting water trees by additional analyzing of field examples of failure and case studies from overseas countries and therefore amended VLF $tan{\delta}$ test voltage and evaluation criteria have been proposed.

열화된 XLPE 케이블의 열지급전류 (Thermally Stimulated Currents in Aged XLPE Cable Insulation)

  • 김상준;이남우;정동원;고인석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 하계학술대회 논문집
    • /
    • pp.221-223
    • /
    • 1991
  • In order to evaluate degradation of the aged power cables, thin slices(200m) cut from the aged cables were prepared for thermally stimulated current measurements. Throughout the temperature range, 140 to $280^{\circ}C$ the TSC is greater for the aged material, and sharp peak is observed at $158^{\circ}C$ and $210^{\circ}C$.

  • PDF

Laser 유기 압력 Pulse법에 의한 전력 케이블중의 공간전하 분포에 관한 연구 (A study on the space charge in power cable by laser-induced pressure pulse method)

  • 한상옥;김종석;이덕출
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제6권4호
    • /
    • pp.347-353
    • /
    • 1993
  • 레이저 유기 압력 펄스법을 이용하여 가교폴리에틸렌필름과 전력케이블의 공간전하의 성질을 정량적으로 연구하여 다음과 같은 결론을 얻었다. 잔류가교제를 갖는 XLPE에서는 음극으로부터 현저한 전자주입이 나타나고 시료전체에 걸쳐 부의 공간 전하가 형성되었으며 음극으로 부터의 전자 주입은 전계상승에 따라 증가 하였다. XLPE 전력 케이블에서는 잔류가교제가 이온화하여 생긴 정 및 부의 헤테로 공간 전하가 음극 및 양극 부근에 형성되었다.

  • PDF

전력용 XLPE 절연체의 부분방전진전에 따른 방사전자파 특성 (Characteristics of Radiated Electromagntic Wave Caused by Progress of Partial Discharge in Power XLPE(Crosslinkable Polyethylene) Dielectric)

  • 이현철;박광서;윤대희;이상훈;김종환;김기채;이광식
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 춘계학술대회 논문집
    • /
    • pp.304-307
    • /
    • 2004
  • This paper simulated partial discharge caused by 22.9[kV] power cable using XLPE(Peroxide Crosslinkable Polyethylene) insulation having the outside damage. As one of the insulation diagnostic method a radiated electromagnetic waves were measured by an UHF method using a BiconiLog antenna(EMCO-3142) and a spectrum analyzer used to measure EMI, EMC. From results of this study, It was confirmed that discharge progress were possible to be estimated by the proposed method.

  • PDF

345kV급 가공송전선로와 GIL이 연계된 혼합송전계통에서 개폐과전압 해석 및 검토 (Switching Surge Analysis and Evaluation in Combined Transmission System with 345kV GIL)

  • 장화윤;이종범;김용갑;장태인
    • 전기학회논문지
    • /
    • 제60권10호
    • /
    • pp.1811-1816
    • /
    • 2011
  • This paper describes switching surge analysis for reclosing decision in 345kV combined transmission line with GIL. Reclosing operation should be decided based on the detailed technical analysis in combined transmission line because this line includes power cable section which is week on insulation. Insulation of power cable can be breakdown at the week point in case of reclosing moment. Therefore the detailed analysis has to be carried out by considering several conditions such as charging rate, inserting resistance, arrester, length ratio of power cable section, grounding resistance, etc. Analysis is performed by EMTP/ATP.

전력케이블 절연층용 원재료의 특성비교 (Characteristic Comparison of Raw Materials Used for Power Cable Insulation)

  • 오우정;고정우;김종은;서광석;이건주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 추계학술대회 논문집 학회본부
    • /
    • pp.302-304
    • /
    • 1997
  • Chemical structure and electrical properties such as water treeing and space charge accumulation of various raw materials(XLPE) used for power cable insulation were investigated. It was found that chemical structure was changed after crosslinking reaction and every materials have different amounts of DCP and antioxidant. Electrical properties were also changed after extraction using $CHCl_3$ and xylene. Water tree length was smaller with additives such as DCP and antioxidant and bigger with low molecular weight components of polyethylene than that of extracted samples. Heterocharge was changed into homocharge after extraction. This shows that additives and low molecular weight components of polyethylene cause the heterocharge.

  • PDF

친환경 비가교 폴리에틸렌의 전기적 특성과 워터트리 가속열화에 관한 연구 (A Study on Electric Properties and Accelerated Water Tree Degradation of Environmental-friendly Non-crosslinked Polyethylene)

  • 이준호;공태식;김성중;권기형;이재순;구광회;조규철
    • 전기학회논문지
    • /
    • 제61권6호
    • /
    • pp.827-832
    • /
    • 2012
  • The crosslinked polyethylene (XLPE) is the most widely used insulating material for power cable. Due to its thermosetting characteristics, the XLPE can not be recycled, while the needs for the environmental friendly and recyclable insulator is rapidly increasing. In this paper, some important and basic electrical properties of non-crosslinked polyethylene such as conduction current characteristics, water the tree characteristics, AC breakdown test were experimentally investigated. It was shown that some of the tested samples had better performances from the application point of view for replacing current XLPE.

발전소에서 운전 중인 활선 6 kV CV 단심 cable의 도체온도에 따른 피복 표면온도 및 부하전류 특성 분석 (Analysis of Sheath Temperatures and Load Currents Dependent on Conductor Temperatures in Live 6kV CV Cables Operating at a Power Station)

  • 엄기홍
    • 한국인터넷방송통신학회논문지
    • /
    • 제17권3호
    • /
    • pp.189-195
    • /
    • 2017
  • 발전소의 발전기에서 생산된 전기를 외부 단자로 공급하기 위하여 유일하게 사용되는 수단은 6 kV CV 단심 cable이다. 발전소에서 발생하는 여러 종류의 사고들 중에서 cable의 열화로 인한 화재 사고는 막대한 사회 경제적 손실을 초래한다. 설계부터 시공 및 관리를 더욱 철저히 해야 한다. 설치환경 및 사용 조건 부하량 등에 따라 차이가 있겠지만, 증설과정, 부적절한 설계 등으로 인하여 cable의 단면적이 부족할 경우가 발생하며, 운전 전류에 의하여 초과된 허용온도는 cable의 열화 상태를 초래한다. 우리는 cable의 사고를 체계적으로 감시 및 예방하기 위한 측정 장비를 개발, 한국서부발전 주식회사(Korea Western Power Co., Ltd.)에 설치하여 활선 cable을 진단하였다. 이 논문에서 우리는 cable이 설치되어 있는 주위환경 특히, 주위 온도에 따라 변동하는 cable의 피복표면의 온도를 측정하고 이에 따른 부하 전류를 검토한 결과를 제시한다. 실제 예로서 주위 온도가 $40^{\circ}C{\sim}10^{\circ}C$의 경우에 피복의 표면 온도와 부하전류의 특성을 연구한 결과를 제시한다.