Development of System and Measured Results for Measuring Insulation Resistance of High-Power Cables in Operation (활선 고전력 케이블의 절연저항을 측정하기 위한 시스템 설계 및 측정결과)

  • Um, Kee-Hong;Kim, Bo-Kyeong
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.16 no.4
    • /
    • pp.165-170
    • /
    • 2016
  • The XLPE(or CV) cables installed to deliver high electric power from generator at the power station have operating for the last 40 years in Korea. In 6-8 years from the time of initial operation, the cables in operation start a deteriorating process, depending on the installation and usage conditions. Some cables, even before 6-8 years from the installation, can cause accidents due to the faulty construction or other inadequate environments. In order to prevent cable accident in advance, the regular auditing of power cables are required. For a systematic realization of surveillance and prevention of accidents, we have invented a measuring device. In this paper, we present the device installed at Korean Western Power Co. Ltd., in order to detect the deterioration status of insulation resistances of dielectrics in the cables. We present that the measured results by the device we developed show the deteriorating processes in the cables in operation.

A Study on the DC Voltage Withstand test for the Ageing of XLPE Power Cable (직류내전압 시험이 전력케이블(CV) 절연체에 미치는 영향연구)

  • Lee, Jun;Lim, Yong-Bae;Kim, Jong-Seo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.613-616
    • /
    • 1999
  • Polyehtylene[PE] in polymer insulation materials of used power cable have carried out in abundance of experiment and study for electrical conduction, insulation breakdown, dielectric character and so on. when apply to field for power cable to make PE, application of DC withstand test to put in practice for inspection is get to effect accumulated space charge. In this paper, to make use of Pulsed Electro-Acoustic(PEA), It is analysis to take shape space charge under AC and DC, clear up the point at issue for DC withstand test impressing

  • PDF

Investigation on Electrical Tree Characteristics blended at weight of HDPE Mixed with EVA (HDPF/EVA혼합수지의 혼합 비율에 따른 전기트리특성 연구)

  • Jung, Eui-Hwan;Yoon, Jae-Hun;Lee, Seung-Su;Lim, Kee-Joe;Lee, Hung-Kyu
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.264-265
    • /
    • 2009
  • In this study, each specimen blended at weight proportions of 80% HDPE to 20% EVA, 70% HDPE to 30% EVA, 60% HDPE to 40% EVA, and 50% HDPE to 50% EVA was manufactured respectively. FE-SEM analysis were carried out as auxiliary analysis means. The insulation performances of the proposed insulator were compared with conventional XLPE, main insulating material of CV cable on the basis of the investigation results of AC insulation performances.

  • PDF

DEVELOPMENT OF ELECTRICAL TESTING FACISITY ABOUT U.H.V. CABLE AND ACCESSORY (극 초고압 케이블 및 접속함 전기 시험 단말의 개발)

  • Kim, J.H.;Oh, E.J.;Kim, H.J.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.2014-2016
    • /
    • 2000
  • In order to meet recent increasing demand for electric power in large cities, plans are being made to introduce 345kV lines into large urban areas. Up to now, OF cables have been used for 345kV fines, but nowadays XLPE insulated cables are preferred as they are easier to maintain due to phenomenal advances in plastic insulation technology, therefore cable manufacturing companies are trying to improve the performance and reliability of UHV CV cables and their accessories. For the purpose, our company has developed facilities for testing UHV cables. In this paper, we describes the methodology adopted for the design and development of a test termination, conducted the electrical test of UHV cables. Based on detailed analytical studies for electrical field distribution, the internal electrical design for the testing end has been carried out.

  • PDF

A study on Electrical Potential Characteristics of HDPE Mixed with EVA (HDPE/EVA혼합수지의 전기적 분포 특성에 관한 연구)

  • Jung, Eui-Hwan;Heo, Jun;Lee, Seung-Su;Lim, Kee-Joe;Lee, Hyung-Kyu
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1447_1448
    • /
    • 2009
  • In this paper, each specimen blended at weight proportions of 80% HDPE to 20% EVA, 70% HDPE to 30% EVA, 60% HDPE to 40% EVA, and 50% HDPE to 50% EVA was manufactured respectively. The insulation performances of the proposed insulator were compared with conventional XLPE, main insulating material of CV cable on the basis of the investigation results of DC insulation performances. From the space charge density, electric field and potential profiles with raising DC voltage and time variation in HE82, distortion of electric field distribution was improved. As EVA mixed into the bulks acts as nucleation in crystallization process of HDPE, the size of spherulites became decreased and finally formed continuous network structure. Ultimately it resulted from extinction of space charge in the interfacial region of spherulites.

  • PDF

A Study on Space Charge Distribution of HDPE Mixed with EVA (HDPE/EVA혼합수지의 공간 전하 분포에 관한 연구)

  • Jung, Eui-Hwan;Heo, Jun;Yoon, Jae-Hun;Lim, Kee-Joe;Lee, Hyung-Kyu
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.11
    • /
    • pp.2229-2235
    • /
    • 2009
  • In this paper, each specimen blended at weight proportions of 80% HDPE to 20% EVA, 70% HDPE to 30% EVA, 60% HDPE to 40% EVA, and 50% HDPE to 50% EVA was manufactured respectively. The insulation performances of the proposed insulator were compared with conventional XLPE, main insulating material of CV cable on the basis of the investigation results of DC insulation performances. From the space charge density, electric field and potential profiles with raising DC voltage and time variation in HE82, distortion of electric field distribution was improved. As EVA mixed into the bulks acts as nucleation in crystallization process of HDPE, the size of spherulites became decreased and finally formed continuous network structure. Ultimately, it resulted from extinction of space charge in the interfacial region of spherulites.